HC FLOW METER. Quick Start Guide. hunterindustries.com. Hydrawise Ready

Similar documents
HC FLOW METER. Quick Start Guide. hunterindustries.com. Hydrawise Ready

Smart Wi-Fi Sprinkler Timer and Flow Meters

SOIL-CLIK. Soil Moisture System. Owner s Manual and Installation Instructions

NEW NEW PRODUCTS DIAMOND QUICK FITTINGS BRASS MANIFOLD CROSS THREADED TAP CONNECTOR HOSE TO BAYONETT CONNECTOR 2 WAY MANIFOLD HOSE TO HOSE CONNECTOR

DIG Corporation Irrigation product Specifications

CONSTANT PRESSURE CONTROLLERS

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

ELD DRIVER GUIDE June 21, 2018

Contents Getting Started with PrePass ELD...4 Starting a Trip...7 During a Trip Co-Driver Features... 14

AUTOMATIC SPRINKLER TIMER

RailPro DCC User Manual

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

WVC. Wireless Valve Controller. Multiple Station Battery Powered Irrigation Controller. Owner s Manual and Installation Instructions

FLOW METER TROUBLESHOOTING

PRO series programmer

FLOW METERS FOR MINING

M40/50RF System - Installers Guide

Model 1000 Vortex Meter

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

IrriGreen Installation Guide With Diagnostic / Troubleshooting Screens

12 STATION MANUAL CONTROLLER INSTALLATION AND OPERATING GUIDE MODEL HRM-12

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Sentinel Field Satellite Controller

Innovations in Remote Controls

MP Rotator : High Efficiency Multi-Stream Rotating Nozzle

Hydro-Flow Model 2200 Installation and Operation Guide B

RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

Method. Remote solenoids. QuickInstall Guide

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

Safe, comfortable and eco-friendly, Smart Connected Society

Model: K0072. Smart Bluetooth Robot Car Kit User Guide

AG2000 IRRIGATION MAGMETER INSTRUCTIONS

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

UltraPrecise Auto Top Off Liquid Level Controller (LLC-UPLC-ATO)

NC State University Design and Construction Guidelines Division 23 Energy Management

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

E-Coder)R900i Quick Install Guide. E-CODER)R900i QUICK INSTALL GUIDE

Pre-plumbed Blowdown Assembly ½ Model

RAM Rail Mount Kit RAM 201UD 5 Arm RAM 2461U Base RAM 235U Base, Double U-Bolt

Hydro-Flow Model 3100

THERMAL CONTROL SYSTEM OPERATION AND MAINTENANCE MANUAL

Hydraulic Calculations

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

WMX-series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

IS0306 rev. B ecn /2013. MG Tachometer (NMEA2000 and J-1939) TACH 1760 RPM FUEL. Installation / User Manual.

FUEL FLOW SENSOR INSTALLATION GUIDE

Product Instructions. Diverting Valve. Valve Cross Section. Features. Specifications. Operations

Using the Electronic Logging Device (ELD)

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

HEAVY-CAPACITY LOAD CELL WEIGHING SYSTEMS

EPAS Desktop Pro Software User Manual

There is a Certification menu option that indicates that the mobile APP, mobile device used were self-certified according to federal requirement.

Hydro-Flow Model 2300 Installation and Operation Guide B

LCD Annunciator Installation Instructions

200 Series - Plastic Hydraulic/Electric Control Valves. Water Control Solutions

RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer.

Turbine Flow Meter Series Turbine Meter USER MANUAL

Electrical Safety Slide Show Presenter s Notes

Presenter s Notes SLIDE 1. Before darkening the room, offer a welcome and overview. Begin by introducing the program and its topic:

SEN and SEN Outdoor Air Temperature Sensors

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

MP ROTATOR. Design Guide High-Efficiency Multi-Stream Nozzle PILOT SYSTEM DESIGN GUIDE. hunterindustries.com

- Wiring Brochure Zone Manager 336

Operation and Maintenance Manual

Liquid Turbine Flowmeter

MODEL 1100 TURBINE FLOW METER

COMMERCIAL DC VEHICULAR SWING GATE OPERATOR

CONSTANT PRESSURE CONTROLLERS

Devices installed in a race car should be divided into two categories: power devices and control devices.

SERIES TBS INSERTION TURBINE TBS-0XX TBS-1XX

INSTALLATION AND OPERATING

Tracer VMA with AutoReg

Issue 2.0 December EPAS Midi User Manual EPAS35

WiFi Tank Level Monitor Installation Instructions

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

1 of 9 5/29/2014 6:01 AM

Propeller Meters. Flow measurement solutions for water and wastewater

Digiflo. Digital Fuel Management System. OPERATING MANUAL Single and Twin Engine Indicators. Shadin. For P/N: 91052XP

www. hydrofuse.com Installation Manual Fertilizer Machine V1.3

PLEASE READ THOROUGHLY PRIOR TO USING VILO Vinyl Liner Leak Locator

SERIES FLMG MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

EX100/200-Series INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX110 EX210 EX150 EX :2008 ISO CERTIFIED COMPANY

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Air Cylinders Drive System Full Stroke Time & Stroke End Velocity. How to Read the Graph

CONTROLLERS & SPECIAL VALVES

PULSE-8: MASTER PULSATION CONTROL

SyncUP FLEET. Implementation Guide

Instruction Manual IZMS 0. - ENTER ACCURATE IZMS

Prism PI Intelligent features offer advanced performance

HYDROMETERS OPERATION, INSTALLATION & MAINTENANCE GUIDE

Valve Lash and Valve Bridge Adjustment

ASV Valves V E S A S V. Electric valve with Atmospheric Backflow Prevention For Residential Systems

Accu-Guard Compact + Ideal for Industrial / Manufacturing Applications or Shop Environments. Take complete CONTROL of your fluid inventory.

AQUIS Foam System. Installation, Operation, and Maintenance Instructions AQUIS 1.5, AQUIS 3.0, and AQUIS 6.0

Version 1.0 Copyright DC-RPM-iBox User Manual

Congratulations. You ve just purchased the most advanced flasher available on the market today. This

Transcription:

HC FLOW METER Hydrawise Ready Quick Start Guide hunterindustries.com

TABLE OF CONTENTS Contents 4 Planning 5 Installing 6 Configuring 7 HC SUPPORT Thank you for purchasing the Hunter HC Flow Meter. In this Quick Start Guide, you will learn how to install and configure the HC Flow Meter. For support of Hydrawise cloud software or help with your Hydrawise account, please visit hunter.direct/hchelp. For specification information, refer to hunter.direct/hcflow.

SENSOR 1 SENSOR 2 COMMON ZONE 1 ZONE 2 Min. of 10 times pipe diameter Min. of 5 times pipe diameter Note the flow meter s flow direction arrow if present 3

HC Flow Meters The flow meter consists of two parts: 1. Flow meter body: The flow meter body contains an analog dial for manual readings as follows. Your flow meter will have three wires protruding from the flow meter s body. The wires need to be connected to the sensor inputs on the controller for remote measurement. In all models, only two wires (blue and white) are used. 2. Adapter: Each flow meter has an adapter to allow connection to your irrigation system. Note: The flow meter will read in U.S on the dial. You can change the units in the app to gallons (gal) or liters. Dial Marking Measurement Unit X0.01 0.01 gallon X0.1 0.1 gallon X1 1 gallon X10 10 gallons X100 100 gallons 4

PLANNING Planning is an important step in the successful installation of your Hunter flow meter and the reliable operation of your irrigation system. 3. Flow meter entry location: Flow meters are installed between the master valve and zone valves. To avoid false alerts, there should be no water taps or other uncontrolled water use on the downstream side of the flow meter. If all solenoids connected to the controller are not grouped together, it may be necessary to install more than one flow meter. The flow meter should be installed with 10 times the pipe diameter before and five times the pipe diameter after the flow meter of straight pipe. 4. Cable: Two-wire cable is required. The cable gauge is determined by the total length of cable between the controller and the flow meter. For cable lengths greater than 100, lightning-prone areas, or cable running near buildings, use shielded cable. The cable should consist of two dedicated wires and must not be in the same conduit or cable bunch as the solenoid wires. Do not share the common wire of the solenoids with the common of the sensors. Flow Meter Cable Length Chart Wire Size Max Length Gauge Feet 20 240 18 1,000 5

INSTALLING The following instructions assume you have already installed your Hydrawise controller. 1. Flow meter body: The flow meter has a marking on the body indicating the direction of water flow. Installation of the flow meter must be in the correct orientation with water flowing in the direction of the arrow on the flow meter body. All HC flow meters must be installed horizontally with the dial facing upwards. 2. Connect flow meter wire: Two-wire cable is required. The cable required to connect your flow meter must be dedicated to the flow meter and not shared with the common wire of the valves or other sensors. The cable gauge is determined by the total length of cable between the controller and the flow meter. The general rule is that 0.5 mm (20GA) wire is good for a run of up to 240 feet. Connect the wires to your Hydrawise controller. Note: All wire connections should be done using waterproof connectors. Wire Color White Blue Red Sensor Terminal Block Common SEN1 or SEN2 Not used: Wire should be capped with waterproof splice. 6

CONFIGURING Configuration of your flow meter is completed using your Hydrawise account. 1. Log in to your account: Enter your log-in information. 2. Create a flow sensor: It is important that you select the correct flow meter when configuring your Hydrawise app. Choosing the wrong model may cause the Hydrawise controller to measure the wrong water flow. HC FLOW METER SELECTION CHART FOR THE HYDRAWISE APP METER SIZE DESCRIPTION U.S. GALLON PULSE RATE 3/4" 3/4" flow meter 1 pulse per 0.1 U.S. gal. 1 1" flow meter 1 pulse per 1 U.S. gal. 11/ 2" 11/2" flow meter 1 pulse per 1 U.S. gal. 2" 2" flow meter 1 pulse per 1 U.S. gal. 3. Assign zones to the flow sensor: Refer to hunter.direct/hchelp for app/software setup information. 7

TROUBLESHOOTING Need more helpful information on your product? Find tips on installation, controller programming, and more. hunter.direct/hchelp RESIDENTIAL & COMMERCIAL IRRIGATION Built on Innovation Learn more. Visit hunterindustries.com LIT-694-QS-US 07/17