SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION

Similar documents
Hydraulic Pumping System

INSTALLATION DATA 712 Series Pilot

Shark R MODEL 925A/925SS OPERATING INSTRUCTIONS AND PARTS MANUAL SPECIFICATIONS SHARK PRESSURE WASHERS ENGLEWOOD, CO

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

Shark R MODEL 1020A/1020SS OPERATING INSTRUCTIONS AND PARTS MANUAL SPECIFICATIONS SHARK PRESSURE WASHERS ENGLEWOOD, CO

Troubleshooting Manual

HVF110, 210, 310, 410HD

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting

VAL6 KBE5S. Service Manual


HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

G 2500 PH English... 2 Español Français (05/05)

Trouble Shooting Guide EWA, 3-phase (D2422)

HD 2.5 / 24 P English... 2 Español Français (04/05)

HD 3.1 / 31 P (03/15)

Signature Series. Duplex Softener Service Manual

Commercial and Industrial Hot Water Gas and Diesel Driven, Oil Fired OWNER S MANUAL. Website:

Modulating Furnace Information. Warning on Meter Setting - Read First!

Routine Burner Service

MANUFACTURER OF HIGH PRESSURE SPRAYING EQUIPMENT. Equipment Preventative Maintenance

OPERATING INSTRUCTIONS AND PARTS MANUAL. serial number: date purchased: for sales and service, please contact:

Heater Troubleshooting Guides

23200 Navigator Dilution Control System 4 Button Model (NAV 4)

Service Manual. Contents. Names of components. 3. Specifications Wiring Diagam Sequence Time Chart

BLOWER VACUUM SWITCH FAILED OPEN

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 13 HP DIRECT DRIVE PRESSURE WASHER CATALOG NO

Commercial and Industrial Cold Water Gas OWNER S MANUAL. Website:

3000 PSI GASOLINE HIGH PRESSURE WASHER

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

7 Maintenance Do not allow the sludge accumulation in the tank to exceed a 1 depth. Otherwise, the sludge build-up could damage the heating element(s)

Commercial and Industrial Cold Water Electric OWNER S MANUAL. Website:

FUEL SYSTEM. Table of Contents. Specifications. Section 3A Fuel Delivery System. Models 6/8/9.9/10/15 CARBURETOR SPECIFICATIONS

Express Service Manual Central Systems

ATD-6810 SPRAY GUN W/CUP INSTRUCTION MANUAL

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Troubleshooting 3Z8 038 Rev B

Shark R MODEL B2535H/1 OPERATING INSTRUCTIONS AND PARTS MANUAL SPECIFICATIONS SHARK PRESSURE WASHERS ENGLEWOOD, CO

1600 PSI ELECTRIC PRESSURE WASHER

Power Flame Incorporated

HVF110, 210, 310, 410HD

VAL6 Infrared Heater KBE5S & KBE5L. (2-step) Maintenance Manual

Where to Find Us. Pressure Washer. Model Number Revision Serial Number. Date Purchased

OPERATORS MANUAL for Electric Pressure Washers

Owner's Manual. Buffalo Series Industrial Hot Water Electric Driven Natural Gas and Propane Fired

Owner's Manual. Commercial and Industrial Hot Water Electric Driven, Oil Fired

Antifreeze Type SYC1025 (Long life coolant) Mixing ratio (water:antifreeze) Cooling fan module Type Electric Capacity

WEBER CARBURETOR TROUBLESHOOTING GUIDE

Section 7 - Troubleshooting Guide

OPERATING MANUAL AND PARTS LIST

Troubleshooting Electronic Ignition

MK Rittenhouse & Sons Ltd. 115 Litre/30 US Gallon Greenhouse Sprayer Manual

2000 PSI. Pressure Washer. SP-WG200. Owner s Manual

SHORTENING FILTER. Operating Instructions INSPECT CARTON SPECIFICATIONS PARTS. MODEL NO'S 102 & 107 CE Series

HEG HIGH VOLUME SERIES HOT WATER PRESSURE WASHERS

Heavy Duty Sprayer Owners Manual Model MS-O

Troubleshooting Guide

Operator s Manual. Model PSI GPM CS CS

This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified.

Service Handbook. High-Pressure Washer Pump

Service Handbook HD /97

WAC Air Curtains Technical Guide

Fuel System Diagnosis

Specifications PERFORMANCE SELLER. 2 Specifications. Discharge Volume. 2.0 gal/m / 7.6 L/m. Pump Head Pressure psi / 111 bar.

Fuel System Diagnosis

FABER BURNER ROUTINE MAINTENANCE

Mobile Diesel Heaters TOR / MIR Technical Training Course

T1-Titanium Non-HVLP Spray Gun

Trouble Shooting Guide for WS1 - WS2 Control Valves

!" # "$""%" & ' ( ) % ""% * "$"% + ,) "! "" -. /$" 0 3 #!4 & $! 5 "! ( 6$ *3-5$ 0. 7, #) "8"$" ",& o #, o 33 ## o 9 #& o. 9 #+ o /1" & o :: &.

MODEL CJ-95 CoilJet Portable HVAC Coil Cleaning System

Page 1 of 12. Part# /30/2016

Circuit Board Diagnostics

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07

Cooling system Type Water cooling, forced circulation Coolant Capacity Approx. 8.0 ~ 8.5 L

ETP-5G & ETP-10G ECO-TECH PLUS GAS CONVECTION STEAMER PARTS AND SERVICE MANUAL

HSS OPERATOR'S MANUAL

INSTALLATION OPERATION/ MAINTENANCE INSTRUCTIONS AND PARTS LIST

1998 ENGINE PERFORMANCE. General Motors Corp. - Basic Diagnostic Procedures - 5.7L

Q35 Series Automatic Vent Damper System

SERVICE MANUAL MODEL # ORDER # XPERT-HD 3.8/35 P PD DA DD

G600 Series Replacement Intermittent Pilot Ignition Controls

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

OH SERIES. Easy-Kleen Pressure Systems LTD. 41 Earnhardt Road Sussex Corner, NB E4E 6A MAGGOLD MAGPLUS MAGELE MAG4000

Hose Heat Control Kit

DEMA Model 294D Spray Foam INSTALLATION INSTRUCTIONS

AIR CLEANERS. Model MX 6000 OWNER S MANUAL CAUTION. Read complete instructions before operating. Please file for future reference.

C.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

HOT WATER PRESSURE WASHER

Operator s Manual. Table of Contents

2400 PSI Pressure Washer

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

BG1600M Intermittent Pilot Ignition Control

Fuel Metering System Component Description

WS2H/ WS3 Error Codes

INSTRUCTIONS. Fc. -1,<" SERIES ST-261 REGULATING UNLOADER VALVE

1200W INVERTER GENERATOR

Largo Cleaning Systems. Wash Bay Solutions. Largo Cleaning Systems. 40 Sevier Lane, Decaturville, TN Phone:

or OWNER S MANUAL MODEL R

ROBERT H. PETERSON CO. AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT REMOTE FOR NATURAL OR PROPANE GAS. Model APK-17(M)(P)

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

Transcription:

Troubleshooting SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION WILL NOT RUN RUNS BUT WON'T SPRAY LOW SPRAY AT NOZZLE UNEVEN SPRAY PATTERN WILL NOT PRODUCE HOT WATER Pump switch in OFF position Place switch in ON position. Power supply disconnected Connect power supply. Fuse blown or circuit breaker tripped Replace fuse or reset circuit breaker. in electrical supply line Use only circuits of adequate capacity. Motor circuit overload tripped Trigger of trigger gun released Water supply not turned on Clogged pressure nozzle Inlet water screen clogged Pump sucking air Inadequate water supply Partially clogged or damaged pressure nozzle Air being drawn through detergent inlet line Partially clogged or damaged pressure nozzle Burner switch in OFF position Gas valve switch in OFF position Inadequate fuel supply Pump switch turned off Allow sufficient time for motor to cool down. Place pump switch in ON position. Squeeze trigger. Open water supply valve. Clean pressure nozzle opening. Check screen and clean if necessary. Fill the detergent container and check for loose hose clamps or fittings. Fully open faucet. Check for kinked or damaged hose. Use 5/8" minimum hose. Check for debris clogging inlet screen. Clean or replace. Refill detergent container. Ensure that pick-up screen is fully immersed. Clean or replace. Place switch in ON position. Place switch in ON position. Check fuel supply. Pump must be running before burner will light. 22

SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION WILL NOT PRODUCE HOT WATER (CONTINUED) POOR OR NO DETERGENT FLOW POOR CLEANING Inadequate water supply Trigger of trigger gun released Thermostat set too low, or defective Manual gas valve not open Defective gas valve Inadequate detergent supply Detergent screen or hose clogged Clogged detergent injector check valve Improper detergent concentration or mixing Wrong detergent for the application Rinsing with hot water Detergent valve not opening Fully open faucet. Check for kinked or damaged hose. Use 5/8" minimum hose. Check for debris clogging inlet screen. Squeeze trigger. Water must be spraying for burner to light. Raise thermostat setting. Replace if defective. Turn ON gas valve. Replace gas valve. Refill detergent container. Ensure that pick-up screen is fully immersed. Clean. Always start with a clean detergent container. Clean check valve at detergent injector. Mix detergent per manufacturer's instructions. Ensure that powdered detergents are fully dissolved. Select appropriate detergent. A final rinse with cold water will reduce water spotting. Check that handle or knob is not slipping on shaft. UNLOADER CYCLES WHEN TRIGGER GUN IS OPENED OR CLOSED BURNER SMOKES OR HAS OBNOXIOUS ODOR RELIEF VALVE LEAKING Air in system Unloader defective Water leak between unloader valve and trigger gun Stack restriction Excessive pressure due to defective unloader valve Defective relief valve Dirty relief valve Open and close trigger gun several times. Replace if defective. Check fittings, hose and trigger gun for leaks. Repair or replace. See Venting under Installation. Replace unloader valve. Replace relief valve. Clean relief valve seat 23

Burner Troubleshooting PROBLEM POSSIBLE CAUSE SOLUTION HAVE PILOT FLAME, MAIN BURNER WILL NOT TURN ON SHORT-CYCLING OF MAIN BURNER. MAIN BURNER TURNS OFF BEFORE THE BURNER SWITCH OR FLOW SWITCH IS TURNED OFF Faulty main valve coil in the gas valve Faulty ignitor/sensor and/or its wiring Ground wire not attached to machine chassis Faulty ignition control unit Draft condition pulls flame from ignitor/sensor rod. Faulty thermostat or water temperature is too high Set test meter to 24 volt scale. With pilot flame on ignitor/sensor, probe terminals MV and MV/PV on the ignition control unit. If you read 24 volts here, but not at the gas valve, there is a loose wiring connection. Repair or replace as needed. If you do read 24 volts at MV and MV/PV and the pilot flame is impinging on the ignitor/sensor rod, the problems may be: a. Faulty ignitor/sensor and/or its wiring. b. Faulty ignition control unit. Set test meter to the ohm scale. Turn burner switch off. Check continuity through the green ground wire and its connections. Reconnect the ignitor/sensor wire and the ground wire. Turn burner switch on. With the pilot burning and the flame on the ignitor/sensor rod, the main burner should turn on. If it does not, replace the ignition control unit. Check the thermostat by bypassing at terminals P1 & 1. Set thermostat high. With main burner on, observe the pilot flame impingement on the ignitor/sensor. If pilot flame is small and draft condition pulls flame from ignitor sensor rod, the burner will turn off and then on again. a. Adjust pilot flame higher or clean pilot oriface. b. Bend ignitor/sensor rod closer to pilot flame. If flame impingement on the ignitor/sensor is stable and the system short-cycles, check the limit switch. Set test meter to 110 volt scale; a. When the system cycles off, probe the switch terminals of the limit switch. b. If you read 24V accross the switch terminals the limit switch is open. Replace the limit switch. A pilot flame set too high will also cause burner to short cycle. Pilot flame lifts over ignitor/sensor. 24

PROBLEM POSSIBLE CAUSE SOLUTION FLOW & BURNER SWITCH ON; NO SPARK, NO PILOT GAS HAVE SPARK, NO PILOT GAS FLOW HAVE PILOT GAS, NO SPARK A. No main power B. Faulty transformer C. Faulty burner & flow switch D. Faulty ignition control unit Main gas supply turned off A. Defective ignitor/ sensor and or its wiring B. Faulty ignition control unit With power switch on, open trigger on spray gun and set your test meter to the 24 volt scale. Probe terminals 24V and 24V(GND). If you do not read 24 volts, the problem is not the ignition system. Perform normal system checks of main power, transformer, thermostat and the limit control. If you do read 24 volts at TH and GND, the problem is in the ignition system. Check for loose or defective wiring. If wiring is good, replace the ignition control unit. Set test meter to 24 volt scale. 1. Be sure main gas valve (gas cock or selector arm) is turned on. 2. With gas on and system sparking, probe terminals PV and 24V(GND). If pilot gas does not flow with 24 volts at these terminals, replace gas valve. 3. Probe terminals PV and MV/PV. If 24 volts not present, replace ignition control box. Set test meter to ohm scale. 1. Disconnect the wire from the IGN terminal on the ignition control unit. 2. Touch one meter probe to the tip of the ignitor/ sensor rod in the pilot. Touch the other probe to the quick connect at the other end of ignitor/sensor wire. 3. If you have continuity from the tip of the ignitor/ sensor rod to the connector and no spark, replace the ignition control unit. 4. If you do not have continuity through wire and the ignitor/sensor, check for a loose wire connection in the wire. Repair as needed. 5. Check to see if spark shorts to burner ring through a cut in the ignitor wire. 25

IMPORTANT If the pressure washer demonstrates other symptoms or the corrective actions listed do not correct the problem, contact the local authorized Hotsy Service Center. The Hotsy Service Center can be identified by visiting www.hotsy.com. When ordering from your dealer, please provide the following: Model Number: Release: Machine Serial Number: Component Part Number: Description: GAS-FIRED SERIES OPTIONAL EQUIPMENT 835526 Draft Diverter, 8" 26