Power Mod. Standard Tapboxes.

Similar documents
Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

Power Mod. Introduction.

Selection & Application Guide. BFT Main Feed Thru Modules. Power Mod. usa.siemens.com/powermod

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module

Selection and application guide

fastfax Rock Solid TM Load Centers General Information

Power Mod. Meter Stacks: WMM Residential Stacks. Residential Meter Stacks

Product Specification Sheet #3LD2.1

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

Power Mod. Type WMM Residential Meter Stacks. Revised 06/01/13. Residential Meter Stacks

New York City Apartment Metering Meter Sockets / Load Centers

Group Meter Main - Without Bypass

Selection and application guide

Product guide. Enclosed NEMA starters. Answers for industry.

Multiple Metering, Horizontal Gang - Non Lever Bypass

Save time and money, plus increase home value!

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

CT Metering. CT Metering. Meter Mounting Equipment

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

Modular Metering. Canadian Version

and legacy Motor Control Center Aftermarket Renewal Parts Catalog

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

Multiple Metering, Vertical Gang

type P1 Lighting and Power Distribution Panelboards Overview P1 Panelboards

Eylander Electric Inc

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Selection and Application Guide For use in New England EQUIPMENT

CON EDISON EQUIPMENT

Meter Centers Meter Mounting Devices

TECHNICAL CATALOG. ReliaGear SafeT interiors OEM power distribution interiors for panelboards and switchboards

5.2. Power Pedestals. Contents Description

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

General purpose cast iron frame motors. The right choice for optimal durability, efficiency and performance. SIMOTICS NEMA Low Voltage Motors

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

6.2. Power Pedestals. Contents

Design Guide for Integration of Fixed-Mount Circuit Breakers

Enclosed Rotary Switch Product Specification Sheets Table of Contents

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

Introduction. Upon completion of Basics of Meter Mounting Equipment

Instruction sheet WARNING. October, 2014

Application guide. Tmax Link OEM UL 891 Switchboard Program

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

Selection and Application Guide. busway system. Cost-effective Power Distribution Compact Design

Selection and application guide. For use in Ohio. Meter Mounting Equipment.

SECTION PANELBOARDS

Instruction and Installation Guide

Accessories. Accessories. Meter Mounting Equipment

Motor Control Centers (MCC) Identification Guide. Answers for industry.

MEG Approval Meter Equipment Group

General purpose aluminum frame motors. The right choice for efficiency and performance. SIMOTICS NEMA Low Voltage Motors.

The Perfect Fit. Introducing the Next Generation of SINAMICS PERFECT HARMONY GH180 Air-Cooled Drive. usa.siemens.

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection

Excellence in testing. Comprehensive test bay solutions from a single source. siemens.com/test-stands

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R

Product Guide. enclosed NEMA STARTERS

Raising the bar on end-to-end conveyor solutions. SIMOGEAR High-efficiency Geared Motors.

Equipment. Metering. Metering Equipment 1. Contents

RMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities

PANELBOARDS SECTION 1

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Reliable.

Contents. Volume 1 Residential and Light Commercial CA E December

Severe duty cast iron frame motors

Meter Mains - Without Bypass

MP Meter-Pak Meter Centers

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

A. Submit manufacturer's literature and technical data before starting work.

Equipment. Metering. Metering Equipment 1. Contents

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

Laser Service Factory-assembled Panelboards

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

ROBICON W120 enclosed drive

Selection and application guide. For use in Texas. Meter Mounting Equipment.

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

Engine Generator Circuit Breakers

PANELBOARDS C1/C2 SECTION 6

Meter Mounting Equipment Wisconsin Area

Selection and Application Guide For use in New Jersey and New York EQUIPMENT

GHN424NW HHN426N HUN361AW

Specialty Service Entrance Switchboards. Selection and Application Guide

Flange Mounted Disconnect Switch. Installation Instructions. Item: I.L. No A00 1 / 12 VBFS364F VBNFS361F VBNFS362F VBNFS363F VBNFS364F

Loadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

Compact, flexible, highest availability. H-compact PLUS

Panelboards Circuit Breaker / Lighting and Distribution

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Selection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting

Service Entrance Methods

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Revised P1 Panelboards

133 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

General Specifications for Lighthouse Power Pedestal

20A-125V DPLX RCPT. Features amperage rating 20. Material, Color, and Finish. Dimensions and Weight. Long Description

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

Transcription:

Power Mod Standard tapbox modules (type WTB) are designed for versatility, space savings, and flexibility. Features include: J QuickSystem features J Standard compression lug capability J Invertibility: devices can be rotated to accommodate the desired incoming feed direction J 750 kcmil AL wire options for most models J 100K AIC standard for all models J Broad ampacity ratings from 400 to 1600 Amps J Line and load capability- service entrance and sub feed rated Standard Tapbox quick reference J 400-1600A J 1200A thru-bus rating J UL Standard # UL67 J UL file # E27100 J AIC rating (100K AIC) J Voltage - Single phase 120/240V AC max - Three phase 240V AC max J All swing latches and rivets are stainless steel. J NEMA 3R rated J G90 galvanized steel J ANSI 61 paint Standard Tapboxes www.sea.siemens.com/powermod

Features Standard compression lug capability 750 kcmil AL wire options. Neutral lug with removable disconnect link Remove for subfeed use. 4 hub openings Siemens/Landis & Gyr HD type hubs 7-2

Features Invertibility Devices can be rotated to accommodate the desired incoming feed direction Connecting cross bus rated 1200 Amps Siemens exclusive feature QuickConnect QuickConnect reduces bussing connections from many to one- ensuring a single reliable connection instead of multiple connections. Mounting ear Pivot factory installed mounting ears to minimum or maximum position to provide additional stability when mounting equipment onto wall. QuickTorque Eliminates the need for time consuming torque readings, this breakaway nut provides the correct indication of torque of the QuickConnect. When tightened, the outer head twists off at the proper torque for connection, leaving a single nut for future maintenance. Siemens exclusive feature QuickBolt QuickBolt eliminates the requirement to line up mechanical connectionsinstead bolts remain retracted until the openings lineup - allowing the bolts to protrude through automatically. Springs push the bolts through and provide positive pressure to keep bolts in place while wingnuts are attached and tightened. Siemens exclusive feature QuickRoll QuickRoll eliminates the typical metal brackets for mounting modules to the wall. Instead of metal scraping metal QuickRoll allows the module to glide down the mounting rail via a durable nylon wheel inside mounting bracket. 7-3

Catalog numbers Tap box modules: 1-phase, 3-wire WN, 120/240V AC, 100k AIC c Catalog number Ampere rating Service feed b Dimensions (inches) a Height Width Depth Line side connections e (lugs not included) KO drawing no. WTB1400CU 400 OH/UG 40.13 12.22 13.19 1 set of 2 studs T-1 WTB1800CU 800 OH/UG 40.13 12.22 13.19 WTB11200CU 1200 OH/UG 47.13 15.22 13.31 2 sets of 2 studs T-2 T-3 WTB11600CU d 1600 OH/UG 49.09 25.09 13.81 3 sets of 2 studs T-4 Tap box modules: 3-phase, 4-wire SN, 240V AC Max., 100k AIC c Catalog number Ampere rating Service feed b Dimensions (inches) a Height Width Depth Line side connections e (lugs not included) KO drawing no. WTB3400CU 400 OH/UG 40.13 12.22 13.19 1 set of 2 studs T-1 WTB3800CU 800 OH/UG 40.13 12.22 13.19 T-2 2 sets of 2 studs WTB31200CU 1200 OH/UG 47.13 15.22 13.31 T-3 WTB31600CU d 1600 OH/UG 49.09 25.09 13.81 3 sets of 2 studs T-4 a Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, hubs, or hardware protrusions. b Module is invertible- rotate device to point hub openings to appropriate feed direction. c QuickConnect not included. If used for load side application an additional coupler must be ordered. d 1200 Amp maximum feed per side- must be used as a center fed main. e Lugs not included. Refer to page 7-5 for lug size options. 7-4

Lug selector catalog numbers Tap box lug kits Wire Size 500 kcmil 600 kcmil 750 kcmil 1 Phase Amperage # Conductors 400 1 n/a LK11600N2 n/a 2 LK12500N2 n/a n/a 800 2 n/a LK12600N2 LK12750N2 3 LK13500N2 n/a n/a 1200 3 n/a n/a LK13750N2 4 LK14500N2 n/a n/a 1600 5 n/a LK15600N2 LK15750N2 3 Phase 400 1 n/a LK31600N2 n/a 2 LK32500N2 n/a n/a 800 2 n/a LK32600N2 LK32750N2 3 LK33500N2 n/a n/a 1200 3 n/a n/a LK33750N2 4 LK34500N2 n/a n/a 1600 5 n/a LK35600N2 LK35750N2 7-5

Knockout diagrams T-1 WTB1400CU WTB3400CU T-2 WTB1800CU WTB3800CU 7-6

Knockout diagrams T-3 WTB11200CU WTB31200CU T-4 WTB11600CU WTB31600CU 7-7

Catalog number logic example W TB 3 4 0 0 C U Enclosure Incoming feed W = Outdoor Amperage U = 100K AIC rated unit Device 400 TB = Tap Box Phase 1 = Single Phase 3 = Three Phase 800 1200 1600 Incoming feed C = Top and bottom feed construction Siemens Energy & Automation, Inc. Industry Sector 3333 Old Milton Parkway Alpharetta, GA 30005 1-800-964-4114 info.sea@siemens.com www.sea.siemens.com/powermod Subject to change without prior notice Order No.: RPFL-STAPB-0409 Printed in USA 2009 Siemens Energy & Automation, Inc. The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.