REFERENCE CP_TSSPEC_138 0 DATE: JUNE 2006 PAGE: 1 OF 17 TITLE SPECIFICATION FOR POLE- MOUNTED AUTO-RECLOSERS TABLE OF CONTENTS

Similar documents
TABLE OF CONTENTS FOREWORD... 2 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3

TABLE OF CONTENTS FOREWORD...3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

REFERENCE REV CP_TSSPEC_016 1 TITLE SPECIFICATION FOR DATE: NOVEMBER 2010 LIGHTING TABLE OF CONTENTS Page FOREWORD INTRODUCTION

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

34-SDMS-01 SPECIFICATIONS FOR

شركة كهرباء محافظة القدس المساهمة المحدودة

34-SDMS-02 SPECIFICATIONS FOR

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA

045 : 2000 CEB STANDARD

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA

37-SDMS-04 SPECIFICATIONS FOR INTERFACE LOW VOLTAGE MAIN CIRCUIT BREAKERS

43-SDMS-01 SPECIFICATIONS FOR

AS/NZS AS/NZS

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

INTERPLANT STANDARD - STEEL INDUSTRY

Collection of standards in electronic format (PDF) 1. Copyright

STR-1415 SPECIFICATION FOR BATTERY CHARGERS 220V, 30A FOR SUBSTATIONS ANNEXURES B

Menu. Home About this portal Latest updates. Print Save Resource detail Citations. Table of Contents

Technical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear (In Air)

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear (In Oil)

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

INTERNATIONAL STANDARD

Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders

SF6 LOAD BREAK SWITCH. Remote Controlled OCR TELE_1_2013.EN

Outdoor vacuum breaker for railway applications - FSK II

CP Automatic capacitor bank

TEKNISK RIKTLINJE TR05-10E

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

SOUTH AFRICAN NATIONAL STANDARD

INTERNATIONAL STANDARD

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

Technical Specification

INTER PLANT STANDARD - STEEL INDUSTRY THYRISTOR CONVERTORS FOR ARMATURE AND FIELD OF MAIN DRIVE MOTORS. Corresponding IS does not exist

Technical Specification for 12kV and 24kV Current Limiting Fuse- Links for Overhead Applications

Technical Specification of GECOL. Packaged Transformers

NPS/001/017 Technical Specification for Low Voltage and High Voltage Current Limiting Fuse Links

INTERNATIONAL STANDARD

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS

Net +Plus Connection Code

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Equipotential Bonding of Rail Vehicles to Running Rail Potential

E-15 Uninterruptible Power Systems (UPS)

32-SDMS-03 SPECIFICATIONS FOR

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

EE 741 Over-voltage and Overcurrent. Spring 2014

UP TO 17,5 kv LSC 2B PM (METAL-CLAD) WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

AP/UP, AP/MIL Series Magnetic Circuit Protectors

CPG.0 Single busbar gas-insulated cubicles

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

GB/T / IEC :2007

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Solid Dielectric, Single Phase Recloser

Unified requirements for systems with voltages above 1 kv up to 15 kv

University of Houston Master Construction Specifications Insert Project Name

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Zinc Oxide Surge Arrester EXLIM R

SPECIFICATIONS FOR 220KV OUT DOOR CIRCUIT BREAKERS. The networks are mainly of outdoor type. The basic parameters are set out below:

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Combined Current and Voltage Instrument Transformer CVS-P-24-O Technical Specifications

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Reference Number PDS 18 - (RIC Standard: EP SP)

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

33 KV STATIC SHUNT CAPACITOR WITH ALLIED EQUIPMENT

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

CHAPTER 4 PROTECTION REQUIREMENTS

32-SDMS-01 REV. 02 SPECIFICATIONS FOR

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT

(Under Two Part Bid System) Tender No: NFV/ PUR/ BEC K for VCB

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

APPLICATION FOR INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION

Power IT MV Live Tank Vacuum Circuit Breaker Model VBF

NPS/003/002 Technical Specification for 30V Distribution Tripping Battery and Charger Systems

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

43-SDMS-04 REV. 00 SPECIFICATIONS FOR

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

Solid Dielectric, Three Phase Reclosers CATALOG VS11

High Voltage Surge Arresters Buyer s Guide Section Transmission Line Arrester PEXLINK

NPS/003/016 Technical Specification for 48V and 110V Battery and Charger Systems

Net Metering Interconnection Requirements

32-SDMS-02 SPECIFICATIONS FOR

E-15 Uninterruptible Power Systems (UPS)

Title Electrical Technical Maintenance Coding System. Reference Number PMP 01 (RIC Standard: EP SP)

Cobra-S. Catalog Cobra-S

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

Transcription:

TITLE SPECIFICATION FOR POLE- MOUNTED DATE: JUNE 2006 PAGE: 1 OF 17 TABLE OF CONTENTS Page FOREWORD...2 INTRODUCTION...3 1 SCOPE...3 2 NORMATIVE S...3 3 DEFINITIONS AND ABBIATIONS...3 4 REQUIREMENTS...3 5 TESTS...4 5.1 Type tests... 4 5.2 Routine tests... 4 6 PACKAGING...4 7 DOCUMENTATION...5 8 TRAINING...5 9 QUALITY ASSURANCE...5 10 ENVIRONMENTAL MANAGEMENT...5 Drawing 1 Surge arrester dimensions...6 Annex A Bibliography...7 Annex B Revision information...8 Annex C Technical schedules A and B...9 Annex D Stock Items...17

PAGE 2 OF 17 FOREWORD Recommendations for corrections, additions or deletions should be addressed to the: Technology Services Manager City Power Johannesburg (Pty) Ltd P O Box 38766 Booysens 2016

PAGE 3 OF 17 INTRODUCTION Pole-mounted auto-reclosers are widely used throughout electricity distribution industry on medium voltage overhead reticulation infrastructure to interconnect, isolate and protect different sections and equipments. The pole-mounted auto-reclosers are critical to the technical soundness and overall performance of the medium voltage overhead electrical infrastructure. These pole-mounted autoreclosers therefore have to meet the specified technical requirements to sustain the life expectancy of the installation. 1 SCOPE The purpose of this specification is to specify the technical requirements to be met when acquiring pole-mounted auto-reclosers for use on City Power s medium voltage overhead reticulation infrastructure. 2 NORMATIVE S The following documents contain provisions that, through reference in the text, constitute requirements of this specification. All standards and specifications are subject to revision, and parties to agreements based on this specification are encouraged to investigate the possibility of applying the most recent editions of the documents listed below. NRS 036-1, Auto-reclosers and sectionalizers pole mounted types Part 1: Auto-reclosers with local and remote control capabilities for nominal A.C. voltages up to 33 kv 3 DEFINITIONS AND ABBIATIONS The definitions and abbreviations in the above document shall apply to this specification. 4 REQUIREMENTS 4.1 Nothing in this specification shall lessen the obligations of the supplier. The supplier shall be fully responsible for the design and its satisfactory performance in service. Approval by City Power shall not relieve the supplier of the responsibility for the adequacy of the design. 4.2 Only pole-mounted auto-reclosers that comply with the technical requirements of NRS 036-1 shall be supplied. 4.3 The auto-reclosers shall be rated for operation on a 24 kv (U m ) maximum system voltage and be linearly suitable for operation on other lower rating voltage levels i.e. 7.2 kv and 12 kv. 4.4 The auto-reclosers shall not contain/utilise oil for fault interruptions or insulation purposes.

PAGE 4 OF 17 5 TESTS 5.1 Type tests 5.1.1 The auto-reclosers shall have been type tested in accordance with, and found to comply with, the requirements of NRS 036-1 for the following, and the appropriate values and test certificate numbers shall be stated in schedule B: a. Interrupting performance (automatic operation); b. Interrupting performance (manual operation); c. Operating duty; d. Making current; e. Minimum actuating (tripping)current; f. Insulation (dielectric tests); g. Radio interference voltage; h. Temperature rise; i. Mechanical operations; and j. Control equipment surge withstand capability. 5.1.2 Test records of tests performed on identical equipment in the form of copies of test certificates, issued by a recognised testing authority, shall be submitted with the tender in the quantity specified in schedule A 5.2 Routine tests 5.2.1 Routine tests as required in NRS 036-1 shall be carried out as a normal requirement of the contract and, if so required, shall be witnessed by the purchaser or by his appointed representative. No additional charge shall be levied for such tests, or for the production or presentation of documentation related to routine tests. 5.2.2 Duplicate copies of routine tests shall be supplied together with the equipment when the latter is delivered to each of the final destinations stated in the order. 6 PACKAGING All equipment shall be carefully packed to prevent damage or deformation during normal transportation, handling and storage. Each container shall bear the following information on the outside of the container: a. A description of the contents and the type of auto-reclosers; b. The address of the destination; c. The gross mass of the container in kilograms; d. The name of the manufacturer; and e. The purchaser s order number and, if applicable, the port of destination.

PAGE 5 OF 17 7 DOCUMENTATION General information regarding handling, transportation, storage, installation, protection settings, operation and maintenance shall be provided. 8 TRAINING 8.1 A certified training course shall be offered to relevant City Power staff. The training shall include, inter alia, the handling, storage, installation, protection setting, operation and maintenance of the auto-reclosers. 8.2 The associated costs for the certified training course in 8.1 shall be given per person and shall be fixed for the period of the contract. 9 QUALITY ASSURANCE A quality management system shall be set up in order to assure the quality of the auto-reclosers during design, development, production, installation and servicing. Guidance on the requirements for a quality management system may be found in the following standards: SANS 9000, SANS 9001, and SANS 9004. The details shall be subject to agreement between the purchaser and supplier. 10 ENVIRONMENTAL MANAGEMENT The environmental management system shall be set up in order to assure the environmental compliance of the auto-reclosers throughout its entire life cycle (i.e. during design, development, production, installation, operation and maintenance, decommissioning and disposal phases). Guidance on the requirements for an environmental management system may be found in SANS 14001. The details shall be subject to agreement between the purchaser and supplier.

PAGE 6 OF 17 Drawing 1 Surge arrester dimensions

PAGE 7 OF 17 Annex A Bibliography Eskom Specification: SCSSCAAQ1 Specification for pole-mounted auto-reclosers with integrated telecontrol RTU capabilities

PAGE 8 OF 17 Annex B Revision information DATE. NO. NOTES Jun 2006 0 First issue

PAGE 9 OF 17 Annex C Technical schedules A and B for 24 kv pole-mounted auto-reclosers Schedule A: Purchaser's specific requirements Schedule B: Guarantees and technical particulars of equipment offered Item Sub-clause Description Schedule A Schedule B 1 a) nominal systems r.m.s. voltage (Un) kv 22 b) maximum system r.m.s. voltage (U m ) kv 24 c) maximum load current A 630 d) short-circuit breaking capacity rated shorttime withstand current 3 s ka 20 2 e) ambient temperature 1. minimum C -15 2. maximum C 50 3. maximum diurnal variation C 35 f) pollution level Very heavy 3 g) lightning activity High h) Altitude m Up to 1 800 Minimum lightning impulse wave (1.2/50) withstand voltage to earth at sea level Power-frequency (50 Hz) wet withstand voltage to earth at sea level kv 150 kv 50 Creepage distances to earth mm 744 Between phases Between phase and earth 4 Mounting on one pole? Yes/No Yes Critical mounting dimensions in accordance with drawing 1 A: mm 240 400 B: mm 100 (max) C: mm 130 (min) D: mm 200 (min) E: mm 320 (min) Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

PAGE 10 OF 17 Item Sub-clause Description Schedule A Schedule B Detailed drawings required for ARC mounting arrangement with surge arresters fitted? Yes/No Yes Mass of: ARC including the dielectric Kg Mounting hardware (if separate item) Kg Control cabinet and cable Kg Conductor type: Copper Yes/No Yes Aluminium Yes/No Yes Alternative, if not as specified in NRS 036-1 but subject to written approval Details of bushing material type and creepage, if bushing material is of the non-ceramic type Stainless steel 304 or 316 Proposed alternative, subject to written approval Primer (description) Undercoat (description) Final coat (description) Colour of final coat No. G29 light grey Length of interconnecting cable m 5 Description of cable disconnection connector Solar radiation withstand of equipment in the control cabinet Description of door status switch Description of ARC closure prevention when battery has insufficient energy to perform a trip Description of harmonic current inrush restraint protection Specification for SEF function and its filter Are user definable curves available? Yes/No Yes OC, EF and SEF tripping characteristics independently programmable IDTML protection details Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

PAGE 11 OF 17 Item Sub-clause Description Schedule A Schedule B Time-current characteristics of fast curves (if applicable) Maximum operating time of overcurrent definite time delay selectable range High-set instantaneous element setting range Time delay selectable range Description of cold load pick-up function and arrangement and characteristics CLP active duration CLP modification factor setting range EF delayed protection operation Time-current characteristics of fast curves (if applicable) High-set instantaneous element setting range Time delay selectable range s Hot line tag functionalities Yes/No Yes Accessibility of local controls/indications Yes/No Yes ARC status Method of indicating low SF6 pressure Value of d.c. pulse V 0 to +48 Clock accuracy Minimum number of records of local and remote changes to operation settings available 50 Type of record a) Closure b) Trip c) Lock-out d) Waveform capture Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

PAGE 12 OF 17 Item Sub-clause Description Schedule A Schedule B Number of past protection events that are recorded: Overcurrent phase affected and fault current magnitude Earth fault phase affected and fault current magnitude Sensitive earth fault phase affected and fault current magnitude Method of preserving trip counter information 30 day load profile record Yes/No Yes Description of: the computer the computer software the connecting hardware RS232 communication port speed Complete communication protocol Remote configuration Yes/No Yes Version (minimum functionality) V.24 Modem output level between 0dBm and - 30dBm Specification of radio supplied Protocol required DNP3 Level 3 Protocol supplied Details of repeating functionality Remote communication facilities and interface details Method of protocol implementation(full details) If primary supply from an internal battery: Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

PAGE 13 OF 17 Item Sub-clause Description Schedule A Schedule B guaranteed life expectancy of battery number of breaker closure operations available without battery recharging source of the battery energy number of trip operations available Details of power supply Power consumed for operation of ARC to open: a) VA rating VA b) opening coil voltage rating V Power consumed for operation of ARC to close: a) VA rating VA b) closing coil voltage rating V Details of the battery and charger monitoring facility Number of ARC operations and duty cycle Minimum operating voltage? Guaranteed life expectancy of battery Battery charger rate A Measurement method Maximum demand manufacturer type designation place of manufacture insulation medium Air or SF 6 arc extinguishing medium short circuit breaking capacity 3s (ka) 12,5 1s (ka) asymmetrical breaking current ka peak momentary making current ka critical current (maximum instantaneous peak) ka Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

PAGE 14 OF 17 Item Sub-clause Description Schedule A Schedule B schematic wiring diagram general-arrangement drawing Details of maintenance and operating equipment needed required Yes/No Yes Detailed parts list required Yes/No Yes Description of ARC operation: Maintenance intervals expressed as number of operations versus percentage of interrupting rating Details of protection characteristics and application of settings Are instruction manuals and maintenance manuals required? Details of calibration and diagnostic test set Is a list of recommended spares and tools, complete with price and availability required? Method of changing protection settings Details of components and their prices Details of technical back-up facilities available Yes/No Yes/No Yes Yes Protection current transformer (if applicable) Class Ratio Burden VA Protection voltage transformer (if applicable) Class Ratio Burden VA Measurement current transformer details Details of low gas pressure alarm/lockout philosophy (if applicable) A description of the service history, etc. for this type of ARC Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

PAGE 15 OF 17 Item Sub-clause Description Schedule A Schedule B Details of LV trip/ close coil operation Power requirements for a close operation Primary and back-up power supply requirements for testing purposes Maximum separation between control cabinet and ARC Average operating times (in accordance with IEC 62271 for auto reclosing circuit breakers): Time from close coil signal to primary contact make Time from trip coil signal to contact separation at rated fault current ms ms Minimum arcing time at rated fault current ms Maximum arcing time at rated fault current ms Total break time critical current (less than 10 % of the fault current) Make-break time at rated fault current Applicable standards: ANS/IEEE C37.60 and IEC 62271(Part 100) Type test values and certificate numbers for: interrupting performance (automatic) interrupting performance (manual) operating duty making current minimum tripping current insulation (dielectric tests) radio interference voltage temperature rise mechanical operations control equipment surge withstand capability Number of copies of type test certificates required 2 Number of copies of documentation required 2 Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

PAGE 16 OF 17 Technical schedules A and B for 24 kv pole-mounted auto-reclosers Deviation schedule Any deviations offered to this specification shall be listed below with reasons for deviation. In addition, evidence shall be provided that the proposed deviation will at least be more costeffective than that specified by City Power. Item Sub-clause Proposed deviation Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

PAGE 17 OF 17 Material Group: SWG-MV-OH Annex D Stock Items Item SAP No. SAP Short Description SAP Long Description 1 1563 POLE-MOUNTED ARC 24KV 630A 12,5KA POLE-MOUNTED AUTO-RECLOSER, RATED FOR OPERATION ON A 24 KV (MAXIMUM VOLTAGE) SYSTEM AND LINEARLY SUITABLE FOR OPERATION ON OTHER LOWER RATING VOLTAGE LEVELS i.e. 7.2 KV AND 12 KV, 150 KV BASIC INSULATION LEVEL, 630 A LOAD CURRENT RATING, 12,5 KA FAULT CURRENT RATING, 31 MM/KV CREEPAGE DISTANCE, MANUFACTURED IN ACCORDANCE WITH NRS 036-1, ITEM SPECIFICATION NO. CP_TSSPEC_138