SERIES R - MD MOR & GOR

Similar documents
SINGLE STAGE TWO STAGES

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

VALIADIS S.A. HELLENIC MOTORS

EXPLOSION-PROOF ELECTRIC WIRE ROPE HOIST BWX

Motors and drives for applications in explosive atmospheres

Small centrifugal fans made of plastic

List Price. Mult. Sym. C Dim. Single Phase

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase

Modular Explosion Proof Brakes. IECLine rev 0

Circulation pumps BFP-ATEX-T3/T4

Explosion and flame-proof cast iron electric motors

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Oil/air cooler BLK ATEX-3GD

BROCHURE. Low voltage motors and drives for applications in explosive atmospheres

AXIAL FLOW CABINET FAN CGT Series

Explosion and flame-proof single phase electric motors

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Centrifugal fan with highly efficient EC drive motor

Service unit combinations MSB, MS series

Explosion proof electric motor For Fuel dispensing application. Main characteristic

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Solenoid valves VUVS/valve manifold VTUS, NPT

Centrifugal medium-pressure fans fitted with multi-blade

Solenoid coils VACF Type codes

ROOFMASTER STEF-ATEX ROOF FAN

Position Qty. Description Single Price 1 SEV B

Explosion Proof Equipment General Overview*

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

ATEX LABELLING FOR MOTORS AND GEAR UNITS

CYLINDRICAL CASED AXIAL FLOW FANS

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Function. Orifice (mm) NBR (Perbunan) 0 EPDM 1 FKM (Viton) 2 FFKM (Kalrez) / O-ring FKM 4

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Powerful centrifugal fans for universal use: The product ranges TEM and REM

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES

Modular Flameproof Brakes

Surface thermocouple Model TC50

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

HCH/ATEX: Robust wall-mounted axial fans with ATEX certification HCT/ATEX: Robust long-cased axial fans with ATEX certification

-V- New. Valve series VOFC. 2009/08 Subject to change Internet:

TRIVAC. Rotary Vane Vacuum Pumps, Oil-Sealed; 1.5 to 65 m 3 /h (0.7 to 38.3 cfm) S 1,5, Single-Stage. TRIVAC E, Two-Stage. TRIVAC NT, Two-Stage

Flameproof Enclosures

Flame arresters 4301A/4319A ATEX Approved

Load disconnect switch Series 8146/5-V11

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

Hermetical Standard Chemical Pump of PTFE / PFA with permanent magnet synchronous motor ISO 2858 / DIN EN 22858

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Floodlight Series 6521/4

MegaBox Product-specific information

Spring loaded resistance thermometer

Pneumatic valves VUWS/valve manifold VTUS

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Motor driven diaphragm metering pump P D S V N PUMP HEAD MATERIAL. O RING V FKM B D Dutral LUBRICANT TYPE

Table of contents. Technical informations > ATEX Page Technical informations Page Mechanically operated valves Page 13-06

Pneumatic valves VUWS/valve manifold VTUS

xplosion Proof Motors hoyermotors.com Explosion Proof

BFG range BFGC range BFN range

2BV SERIES VACUUM PUMP

M-0. M-0... series control, monitoring and signalling devices. Ex e

Type Z & Ex pz purge and pressurization system

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

FLSD (E) Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information

Zone 1 Linear Range - Installation Guide

Unused flameproof threads for cable glands have to be closed with certified plugs.

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

CGT Series Adjustable Pitch Fans

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

Direct-acting 3/2 way plunger valve

High voltage flameproof induction motors The simplest solution for hazardous environments

Side Channel Blowers & Turboblowers

Sample gas pumps P2.x ATEX

ACCESSORIES FOR BLOWERS

Linear actuators DFPI

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

CGT Series Adjustable Pitch Fans

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

COMPACT Series type HCFB / HCFT (Plastic impellers)

BFG range BFGC range BFN range

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

Flameproof brake motors. Technical data subject to change without notice. BARTEC VARNOST 1

The safety you rely on.

Lighting series JLZ Lighting series JELZ

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Panelboards & Motor Starters

INSTRUCTION MANUAL (ATEX / IECEx)

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

PAB Atex-certified centrifugal pumps

Junction boxes for control, monitoring and control panel Ex tb

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

Compact pressure switch Model PCS

Wolflite XT Rechargeable LED Handlamp

INSTRUCTION MANUAL (ATEX / IECEx)

TRIVAC NT 16 and NT 25

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Transcription:

SERIES R - MD MOR & GOR CHARACTERISTICS OPTIONS Aluminium alloy construction Surface protection treatment (anodising, only for ATEX 2 versions) Available in monoblock execution (MOR) and with coupling (GOR) Condensate drain (only for GOR execution) Blower with increased seal (vacuum sealing of components) Electric motors equipped with thermal protection Painted Surface protection treatment (anodising for ATEX 3 versions only - already included for ATEX 2) Explosion-proof motors Unpainted (for ATEX 3 versions only) Page 1

SPECIFICATIONS 12 Model R20-MD R30-MD R40-MD 2 [kw] Frequency [Hz] Product Code in STD Configuration [mbar] Leq¹ Temperature [db(a)] Class (ATEX) Suction Compression [m³/h] 3GD (MOR) 2G (GOR) 0.75 50 250 325 60 66.0 0.9 60 300 275 70 68.0 1.1 50 300 400 60 66.5 1.3 60 350 450 70 68.5 1.1 50 250 325 91 69.2 1.3 60 275 300 110 72.2 1.5 50 350 425 91 69.7 1.7 60 375 425 110 72.8 2.2 50 275 375 117 70.8 2.6 60 300 350 137 72.8 3.0 50 350 500 117 71.3 3.5 60 375 500 137 73.3 T4 T3 T4 T3 T4 T3 SR20MD00+0023 SR20MD00+0021 SR20MD00+0024 SR20MD00+0022 SR30MD00+0021 SR30MD00+0019 SR30MD00+0022 SR30MD00+0020 SR40MD00+0004 SR40MD00+0002 SR40MD00+0005 SR40MD00+0003 Table 1. Fluid dynamic performance of the blowers with relative installed powers, temperature classes and STD product codes. BLOWER CONFIGURATIONS ATEX environment Model R20-MD R30-MD R40-MD Execution ATEX category 3GD 2G 3/2G 2/3G IP rating (Motor) Electric Motor PTO Thermal Protection MOR STD - - - 65 STD Optional GOR Optional STD Optional Optional 66 - STD MOR STD - - - 65 STD Optional GOR Optional STD Optional Optional 66 - STD MOR STD - - - 65 STD Optional GOR Optional STD Optional Optional 66 - STD Table 2. Blower.configurations with reference to the electric motor and ATEX category. PTC 1 Noise level measured at a distance of 1 m with ducted intake and delivery, in accordance with Standard ISO 3744. 2 Power supply voltage: 230/400 V @ 50 Hz 265/460 V @ 60 Hz. Tolerance on fixed voltage value ± 10%, Motors with class F insulation, suitable for operation with inverter* refer to FPZ (all motors for ATEX environments are equipped with probes or thermal protection). Page 2

ATEX MARKING The final marking of the blower (complete with electric motor) is determined by the chosen options (summarised in the columns of Table 3): for the selected blower model choose the category - as in Table 2 - and the motor power - as in table 1. The abbreviation ATEX is a si Example of Marking By choosing blower Model "R20-MD", in monoblock execution (MOR) ATEX 3GD category (STD for this blower execution), equipped with 0.75 kw motor, the complete marking is ATEX II 3GD c T4 ("II" indicates: machine suitable to operate in a different environment from a mine); if the 1.1 kw motor is chosen instead of the 0.75 kw motor, the marking would differ only for the temperature class, i.e. ATEX II 3GD c T3 Category & Environment (see table 2 - "BLOWER CONFIGURATIONS") Protection Method (the same for all blowers) Temperature Class (see table 1 - "SPECIFICATIONS") 3GD 2G 3/2G 2/3G Table 3. ATEX marking options for the blower unit and electric motor. T3 T4 ATEX MARKING NOTES: Unless specifically indicated, the ATEX marking refers to the "internal" and "external" environment. In the case of double indication separated by a "/", the first number indicates the "internal" category (inner surfaces of the blower), and the second indicated the "external" category (outer surfaces of the blower, including electric motor). Configurations "2G" and "3 / 2G" are all with explosion-proof motors (EX d protection method). c The electric motors have different types of protection depending on the category and the environment for which they are designed and meet the requirements of the gas groups (IIA/B/C) and dust (IIIA/B/C), as indicated in Table 4 Electric Motor Protection Methods Zone Category Environment Protection Method (Ex) MOR execution Sub-groups GOR execution 2 3 G na IIB IIC 22 3 D tc IIIC IIIB 1 2 G d - IIC Table 4. Protection methods for electric motors by category and environment. INSTALLATION For proper operation of the machine, it must be provided with a suction FILTER and a vacuum/pressure limiting device. ATEX certified accessories are available on request: o Analogue pressure gauges and thermometers o Temperature and pressure transducers Filters for Gas available on request - o Condensate drain valves (optional for the other GOR versions - not available on MOR execution) o anodised impeller, cover and body Permissible ambient and fluid temperature in suction from -15 C to +40 C. Read the instruction manual carefully before installing the machine. FPZ, as a manufacturer of ATEX blowers, shall provide advice regarding the appropriate blower. However, the correct classification of the ATEX environment and the corresponding choice of appropriate blower configuration is the purchaser's responsibility. Page 3

SUCTION Operation @ 50 Hz 345 COMPRESSION Curves referring to air at a temperature of 20 C and atmospheric pressure of 1013 mbar (abs.). Tolerance on indicated values ± 10%. Data subject to change without notice. Page 4

SUCTION Operation @ 60 Hz 678 COMPRESSION Curves referring to air at a temperature of 20 C and atmospheric pressure of 1013 mbar (abs.). Tolerance on indicated values ± 10%. Data subject to change without notice. Page 5

DIMENSIONS (MOR EXECUTION: VERSION ATEX II CATEGORY 3) 9 Sizes in mm - NOT BINDING Model a b c d e f g H* i m n o p1 q r s t u R20-MD 283 309 167 47 235 210 G 1"¼ 340 90 10 150 200 345 18 45 22 M6 150 21 R30-MD 319 346 187 47 235 210 G 1"¼ 390 90 10 150 200 354 18 45 22 M6 180 25 R40-MD 350 372 197 47 235 210 G 1"¼ 440 90 10 150 200 364 18 45 22 M8 225 40 Max weight [kg] * The value indicated refers to the machine with motor of maximum length. Page 6

DIMENSIONS (GOR EXECUTION: VERSION ATEX II CATEGORY 3) 10 Sizes in mm - NOT BINDING Model M.E. a a1 b b1 b2 c e f g H* i k k1 n o p1 q r s t u y z Max weight 1 [kg] R20-MD GR. 80 B3 283 169 352 305 56 185 239 170 G 1"¼ 577 90 100 M8 445 475 345 19 234 21.5 19 6 100 125 23 R30-MD R40-MD GR. 80 B3 169 G 583 100 125 319 372 325 38 185 239 170 90 M8 445 475 354 19 237 21.5 19 6 100 GR. 90S B3 174 1"¼ 606 110 140 26 GR. 90L B3 174 G 711 111 M8 125 140 350 402 355 41 205 259 190 90 560 590 364 19 233 31 28 8 GR. 100 B3 185 1"¼ 742 128 M10 140 160 34 POSITION OF TERMINAL BOX Standard version Available on request * The value indicated refers to the machine with motor of maximum length. ** Condensate drain kit available on request. 1 The value indicated refers to the weight of the machine without electric motor. Page 7

DIMENSIONS (GOR EXECUTION: VERSION ATEX II CATEGORY 2) 11 Sizes in mm - NOT BINDING Model M.E. a a1 b b1 b2 c d d1 e f H* k k1 n o p1 r s t u y z Max weight 1 [kg] R20-MD GR. 80 B3 283 119 380 305 56 185 41 56 239 170 577 100 M8 445 475 185 74 21.5 19 6 100 125 23 R30-MD GR. 80 B3 583 100 125 GR. 90S B3 319 119 400 325 38 185 52 55 239 170 606 110 M8 445 475 194 77 21.5 19 6 100 140 26 GR. 90L B3 711 111 M8 125 140 R40-MD GR. 100 B3 350 119 430 355 41 205 13 55 259 190 742 128 M10 560 590 205 74 31 28 8 140 160 34 POSITION OF TERMINAL BOX Available on request Standard version Available on request * The value indicated refers to the machine with motor of maximum length. 1 The value indicated refers to the weight of the machine without electric motor. Page 8