E-200 Module Service Kit

Similar documents
E-200 O-rings Service Kit

Installing an H-200 Integral Right-Angle Module

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet

Series 3900/M Pump Retrofit Kit

Maintenance. Part A, Section 5. This section covers the following unit configurations.

Installation Instructions for Series 3100V Low Level Indicator

Series AD-31 Handgun Swivel Connector Replacement Kit P/N and P/N

Converting an FP-200 Extrusion Gun to an FP-200 Swirl Gun

Preventive Maintenance for Pail Melters

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter.

Introduction. Pressed Shaft Flowmeter. Flowmeter Service Kits. Disassembly. Idler Shaft Removal

5000 Gerotor Pump Service Instructions

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a Universal in-out filter.

Standard and Conical AN Series Air Spray Nozzles

Solenoid Valve Installation Kit

Paint/Solvent/Dump Valve and Flow-Through Valve

Normally Open H200 and 90_ CF200 Module Seal Rebuild Kit

Series 3000V Low Level Indicator

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V

Miniature Soft Seat Fluid Pressure Regulator

Blow Off Valve Retrofit Kit

OPERATOR S CARD. Select Series H-440 Hot Melt Dispensing Guns. Safety. Description. Nordson Corporation P/N D

AN-8 Plus Air Spray Gun Solvent-Based to Waterborne Conversion Kit

Installing the Integral Platen Blow Off Valve

Inverted High Pressure Fluid Filters

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a threaded filter.

Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3400V 3500V 3700V

TCU Static Mixer Installation

Sure Coat 90 Degree Spray Extension

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

Two Component Meter Cylinder Assembly Replacement

Auto-Flo Air-Assist Automatic Dispensing Valve

TCU Flushing Manifold and RTD Installation

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

Auto-Flo Panel Reinforcement Automatic Dispensing Valve

Low Level Indicator. Part E, Section 1. This section covers the following unit configurations. 3500V 3700V 3800V 3900V E2EN 03 [3V LLI] 4

Spray Pressure Control Manifold

Hard Seat Fluid Pressure Regulator

Sure Coat Modular Gun Control System Part D: Gun Purge Module. Customer Product Manual Part B

Spray Pressure Control Manifold

Module. Section 9. NOTE: This section applies to applicators with CC200 modules B Issued 6/01. Manual 42-CF200-CM-01

OPERATOR S CARD. Select Series H-400 Hot Melt Dispensing Guns. Safety. Description/Intended Use. Nordson Corporation P/N E

SP30 10:1 Piston Pump

E-350 Electric Gun. Customer Product Manual Part A NORDSON CORPORATION D AMHERST, OHIO D USA

Rhino SD2/XD2 Electric Container Level Sensors for 125-mm Frames

Optional Nozzles for Versa-Spray and Versa-Spray II Guns

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

0-800 psi Carbide Seat Fluid Pressure Regulator

0 900 psi Pressure-Reducing Diaphragm Regulator

Installing the Low Level Indicator (P/N or P/N )

EP-2 Three-Piston Pump

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A

Iso-Flo Coupling Repair

EP-2 Si Three-Piston Pump

Circulation Kits for CP Pumps

Series H-400 Guns. Customer Product Manual Part D. NORDSON CORPORATION D Duluth, Georgia

Back Pressure Regulator

Upgrading the Sure Coat Modular Gun Control System

0-500 PSI Soft Seat Fluid Pressure Regulator

OBSOLETE. RA-16 Rotary Atomizer Upgrade Kit. Instruction Sheet P/N A. 1. Introduction. 2. Disassembly

Soft Seat Fluid Pressure Regulator

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with MB200 modules.

NRPS-100 Rotary Sieve

Pro-Swirl Manifold Air Heater

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with CF200PAD right-angle modules.

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with bead or slot modules.

One-Gun Add-On Kit For Smart-Coat Controllers

Prodigy HDLV Manual System Installation Instructions

SP30 6:1 Piston Pump. Installation and Maintenance Instructions. Part D NORDSON CORPORATION AMHERST, OHIO USA

PREVIOUS GENERATION. Encore Manual Powder Spray Gun Trigger Switch Replacement. Introduction. Preparation. Gun Disassembly

Description. Repair. Rhinor XD2 Type-H Low Level Drum Proximity Sensor. Replacing the Proximity Sensor

Encore and Spectrum (Global) Powder Feed Center Clamping Cylinder

Mobile Powder Spray System Dolly with Hopper for Cable-Fed Systems

Part A, Section 1. Operation A4EN [3V - A - AAXV] V Issued 5/00. E 2000 Nordson Corporation All rights reserved

Colormax Powder Coating System Color Change Process

Mobile Powder Spray System Dolly with Hopper

Rhino SD/XD Depressurization Modules for Electric Changeover Controls

Sure Coat Modular Gun Control System Part B: Pneumatic Modules. Customer Product Manual Part B

SPRAY RUN-UP CONTROL KIT ( 4-20 ma Version)

Nylon Fluid Regulators

Spectrum VT Inline Powder Feed Pump

Encore Manual Powder Spray Gun Trigger Switch Replacement

Section 5. Maintenance. Risk of Burns. Relieving Pressure. Important when Using Cleaning Agents. Maintenance 5-1

CoolWave 2 Phase Control Board and Cable Replacement Kit

T1-Titanium Non-HVLP Spray Gun

Electrostatic System Checks

Prodigy HDLV System Troubleshooting - Generation III

D Instructions/Parts. Siphon Feed Detail Spray Gun D

TANK LID REPIACtiMENT

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Electric Vibratory Box Feeder Retrofit Kit

Repair. Description. Rhino SD2/XD2 Drum/Pail Level Indicators

A CAUTION: The kit should not be fitted on Series 3800 or 3900

High Flow and 100 PLUS FB Powder Pumps

Retrofitting Kit Filter Cleaning for Cable Coater ECC 700

B Manifold L or P Assembly Parts List. Parts

Transcription:

Instruction Sheet E-200 Module Service Kit 1. Introduction These instructions describe how to remove and replace the E-200 module. The instructions include the following: S S S S Safety Unit Preparation Module Removal and Replacement Alternate Module Removal and Replacement 2. Safety WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. 3. Unit Preparation Perform the following steps to relieve hydraulic pressure before disassembling and replacing any gun component. WARNING: Risk of burns. Failure to relieve system pressure can result in hot material spraying from a connecting point, possibly causing serious burns. 1. Heat the system to operating temperature. 2. Turn the applicator pumps off.

2 E-200 Module Service Kit 3. Unit Preparation (contd.) 3. Place a drain pan under the applicator s filter drain valve. NOTE: Figure 1 shows a typical drain pan placement. Details may vary depending on the applicator model. 4. Follow instructions provided in your applicator s technical manual for relieving system hydraulic pressure. 5. Properly dispose of the drained adhesive. Fig. 1 Typical Drain Pan Placement 4110089 WARNING: Risk of burns. Shield the area and operator. Failure to perform the next step can result in hot material spraying from a connecting point downstream of the applicator pump. 6. Trigger the gun module(s) from the gun driver to relieve pressure downstream of the pump. 7. Turn off the electric gun driver. 8. Wipe off any adhesive on the gun fittings.

E-200 Module Service Kit 3 4. Module Removal and Replacement NOTE: To remove the coil and module assembly with the gun installed at the station, you need a minimum of 3 inches above the coil in order to completely remove the coil from the adapter/pole assembly. If you do not have this minimum clearance or the gun module and coil are badly charred, perform the alternate method of removing or installing the module described in 5. Alternate Module Removal and Replacement Procedure in this document. The alternate procedure requires only 1 inch of clearance above the coil because the coil and module are removed as an assembled unit. 1. Relieve hydraulic pressure as described in 3. Unit Preparation in this document. WARNING: Hot! Risk of burns. Hot applicator parts, splashed adhesive, and hot gun surfaces can cause severe burns. Wear long-sleeved, heat-protective clothing, safety goggles, and heat-protective gloves. WARNING: Risk of electrical shock. Failure to observe may result in personal injury or death. 2. Set the applicator circuit breaker to the OFF position. Fig. 2 Turning Off Applicator Circuit Breaker 4103272 3. Disconnect and lock out the input power line to the applicator main circuit breaker. 4. Disconnect and lockout power to the driver. 4110132 Fig. 3 Locking Out Input Power

4 E-200 Module Service Kit 4. Module Removal and Replacement (contd.) 5. Remove the coil retaining screw from the top of the coil. Fig. 4 Removing the Coil Retaining Screw 4204141 1 6. Unplug and remove the coil from the gun manifold by lifting it straight off of the coil connector and module. CAUTION: During coil removal, do not rock the coil from side to side or front to back. This can result in damage to the plastic coil connector. 2 3 7. Use a hex head wrench and loosen the two module retaining screws by turning them three full turns. 8. Insert a flat screw driver blade between the base of the module and the manifold. Pry the module forward approximately 1.57 mm (.06 in.) to break the seal. 9. Remove the two module retaining screws. 10. Remove the module from the gun manifold. 4204074 Fig. 5 Removing the Gun Module and Coil from the Manifold 1. Coil 2. Coil connector 3. Module retaining screws

E-200 Module Service Kit 5 4. Module Removal and Replacement (contd.) 11. Wipe off any adhesive left on the manifold, especially around the adhesive passage. 12. Coat the new o-ring with lubricant. 13. Install the o-ring in the groove in the back of the new module body. 4204075 Fig. 6 Installing the O-ring 1 4 14. Apply PTFE paste to the two module retaining screws. 15. Position the module on the gun manifold. Then replace and finger-tighten the two module retaining screws. 16. Install the coil on top of the module, carefully connecting its plug to the coil connector on the manifold. CAUTION: Do not overtighten the screws. Overtightening can cause the head of the screw to break off. 2 3 4204139 Fig. 7 Aligning the Module with Gun Manifold 1. Coil 2. Module 3. Module retaining screw 4. Coil retaining screw 17. Tighten the two module retaining screws on the front of the module. Make sure the module is straight and its base is flush with the gun manifold. NOTE: For best results, tighten the screws again after the applicator reaches operating temperature. 18. Reinstall the coil retaining screw on top of the coil. 19. Restore the system to normal operation according to instructions in the applicator service manual.

6 E-200 Module Service Kit 5. Alternate Module Removal and Replacement Procedure NOTE: If there is insufficient clearance above the gun s coil for removal from the module at the station or if the gun module and coil are badly charred, use the following alternate method of removing and installing the module and coil as an assembled unit. 1. Relieve hydraulic pressure as described in 3. Unit Preparation in this document. WARNING: Hot! Risk of burns. Hot applicator parts, splashed adhesive, and hot gun surfaces can cause severe burns. Wear long-sleeved, heat-protective clothing, safety goggles, and heat-protective gloves. WARNING: Risk of electrical shock. Failure to observe may result in personal injury or death. 2. Set the applicator circuit breaker to the OFF position. Fig. 8 Turning Off Applicator Circuit Breaker 4103272 3. Disconnect and lock out the input power line to the applicator main circuit breaker. 4. Disconnect and lockout power to the driver. 4110132 Fig. 9 Locking Out Input Power

E-200 Module Service Kit 7 5. Alternate Module Removal and Replacement Procedure (contd.) 2 5. Use a hex head wrench and loosen the two module retaining screws by turning them three full turns. The coil must still be securely attached to the module by the coil retaining screw. CAUTION: During module/coil removal, do not rock the module from side to side or front to back. This can result in damage to the plastic coil connector. 3 1 4204142 6. Insert a flat screw driver blade between the base of the module and the manifold. Pry the module forward approximately 1.57 mm (.06 in.) to break the seal. 7. Remove the two module retaining screws. Fig. 10 Removing the Module/Coil Assembly 1. Module retaining screws 2. Module/coil Assembly 3. Coil connector 8. Unplug and remove the module/coil as an assembled unit from the manifold by lifting it straight off of the coil connector. 9. Remove the coil retaining screw from the top of the coil. 10. Remove the coil from the top of the module. Be sure to pull the coil straight off of the adapter/pole assembly. 11. Install the coil on top of the replacement module. Be sure the coil is aligned with the back of the module body. 12. Install the coil retaining screw on top of the coil to secure it to the module.

8 E-200 Module Service Kit 5. Alternate Module Removal and Replacement Procedure (contd.) 13. Install the o-ring in the grove in the back of the new module body. Fig. 11 Installing the O-ring 4204143 CAUTION: During module/coil installation, do not rock the module from side to side or front to back. This can result in damage to the plastic coil connector. 14. Install the module/coil assembly onto the manifold by carefully plugging it into the coil connector. Make sure the module/coil assembly is straight and the module base is flush with the gun manifold. 1 15. Apply PTFE paste to the two module retaining screws that secure the module to the manifold. Install and tighten them. 16. Restore the system to normal operation according to instructions in the applicator service manual. 2 Fig. 12 Aligning the Module/Coil Assembly with Gun Manifold 1. Module/coil assembly 2. Module retaining screws 4204140 Original copyright date 1995. Nordson and the Nordson logo registered trademarks of Nordson Corporation.