FM FIRE-SAFE VALVE ASSEMBLIES & ACTUATORS. Meets API 607 Edition 3 and 4, Factory Mutual FM 7440

Similar documents
Valves and Valve Assemblies

Size: 1/4 to 3. Material: 316 Stainless Steel, Carbon Steel,

EMERGENCY SHUTOFF AND FIRESAFE VALVES FIGURE 1075

ID & IP SERIES IN-LINE DISC AND PISTON VALVES

FEATURES FLP SERIES COMPLETE ASSEMBLIES FL SERIES PRODUCT CONFIGURATOR ONE VALVE DOES IT ALL

Specification for FLP-series Fusible Link Packages

Manual & Automated Ball Valves

A Bray High Performance Company A Subsidiary of BRAY INTERNATIONAL, Inc. Ball Valve Selection Guide

Quality, Safety and Environment

Ball and Stem Materials: 316 Stainless Steel Alloy 20 Monel Hastelloy C. Service Applications: Hydraulics Chemical

FEATURES ONE VALVE DOES IT ALL IDEAL FOR YOUR VALVE... OR OURS SURE STOP MOUNTING PLATE BALL OR BUTTERFLY VALVES

earth safe Fuel Systems for Critical Power

FROM SIMPLE TO COMPLEX DESIGNS. Flo-Tite Offers A Complete Line of High Quality Engineered Ball Valves For Your Most Demanding Applications

ALC-3 BUTTERFLY VALVES NOMINAL PRESSURE NOMINAL SIZE MATERIALS CONNECTIONS DESIGN. ANSI Class PN DN

METSO NELES HIGH PERFORMANCE VALVE, METAL SEATED SERIES BW

YARWAY HANCOCK Y-PATTERN FORGED STEEL GLOBE STOP VALVES SERIES 4000

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC&R VALVES

SHARPE HIGH PERFORMANCE VALVES STANDARD FEATURES ADVANTAGES

Item 501M. 3-Way Metal Seated Ball Valve. ASME 150/ 300 & 800 psi SIZE: 1/2"-2"

KOSO HAMMEL DAHL. Specifications. Body Size: Globe - 1/2" through 6" ( mm). Angle - 1/2" through 2" (15-50 mm).

Pig Valves. Complete Solutions for Industrial Valves NEWAY VALVE

Delivering Peak Performance. High-pressure liquid and gas flow control solutions for the oil and gas industry s harshest environments

SVF FLOW CONTROLS. Series # Flanged Standard Port Fire Safe / API th Edition. Performance Engineered I N C O R P O R A T E D

15100 VALVES. E. Section Building Automation and Control System Guidelines

DM9900 Series Segmented V-Ball Control Valve

Condensed Valve Guide Gate Globe Check Ball Strainer. Warren Valve - Quality Since 1963

GO WITH THE FLOW! PRODUCT GUIDE TITAN FLOW CONTROL, INC. TITAN TELEPHONE: YOUR PIPELINE TO THE FUTURE!

North American Automatic Manual Reset and Motorized Valves

A Bray High Performance Company A Subsidiary of BRAY INTERNATIONAL, Inc. Ball Valve Selection Guide

FPS Safety Shut-Off Valves. CSA and FM Approved

Bushing Viton O-ring (Other material available) Anti-Static Device

VALVES. A. Section HVAC Basic Materials and Methods. E. Section Building Automation and Control System Guidelines

Mars Series 88 Stainless Steel Reduced Bore Or Full Bore Ball Valve, Lever Operated, BSP Or Socket Weld Ends

Valtek Valdisk 150. Valtek Valdisk 150. Control Valves. Flowserve Corporation, Valtek Control Products, Tel. USA

Manual & Automated Ball Valves

IN-LINE DISC & PISTON VALVES

VD SERIES VESSEL & REACTOR VALVES DISC VALVES

British Standard institute-bs Valve Standards

* Contact your sales representative for compliance to NACE MR or later requirements.

POWER-SEAL Series P1S / P1F / P1M / P1H Manual and Automated High Performance Butterfly Valves ANSI/ASME Class 150 and 300

Ball Valves & Accessories

W SERIES 3-PIECE BALL VALVES

Sempell High Pressure Stop Valves Model VA510 (DIN)

USER S MANUAL. Installation, Operation, & Maintenance

BULLETIN August 2009 PERMASEAL PLUG VALVE. ISO 9001:2008 Certified QMS. SMG Valves A Unit of Southern Manufacturing Group, Inc.

505F. Multi-Port Ball Valve. Full Port ISO 5211 Mounting Pad. For Automated & Manual Service. General Chemical. Industrial

FILTERS, STRAINERS AND VALVES PRODUCT GUIDE

Products for the Oil & Gas Industry

Sampling Valves. Probenahmeventile. SchuF. Fetterolf

Actuated Valves PRICING

Condensed Valve Guide Gate Globe Check Ball Strainer. Warren Valve - Quality Since 1963

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Butterfly Control Valve

FORGED HIGH PRESSURE BONNETLESS. ASME CLASSES: Sizes: 1 2 4" ( mm) U.S. Patent # Patented Easy Maintenance!

Valve Selection. 1. Function and service considerations

Series Direct contact and metal-to-metal seating makes the T-pattern globe stop valve ideal for most shut-off applications.

Tufline XP Sleeved Plug Valves

Electronic Ball Valve Guide Specifications

Forbes Marshall Control Valve. Operational Economy with Optimum Control

MANUAL & AUTOMATED BALL VALVES

Valves. Fittings. Actuators

Please note this is a condensed catalog. For a complete version, contact Velan directly.

IMO-517 (7027) ISSUE 3/97 ERA12, 25, 50, 83, 125, 167, 208 AND 250 ELECTRIC ACTUATORS INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS

Op-GL - Globe Control Valve

BRASS BALL VALVES. CSA, UL, cul CGA 9.1 and FM Approved. Female NPT, Male NPT and Flare ends in various configurations from 3/8 to 1.0.

LOWER MACUNGIE TOWNSHIP COMMUNITY CENTER ADDITIONS AND RENOVATIONS

Standard-Low Emission Valves to 100 PPM. A-Series Brass Appliance Valves CSA Approved; 1 & 2 piece Body Designs; Threaded & Flare End connections

Series 44 Ball Valves 3-piece ball valves designed to meet all requirements of ANSI B Worcester Controls PB

V-Notch Control Valve. Diameter Type Nominal Pressures Plug Materials Seat Materials Actuators. ANSI Class Flanged and Flangeless

Gate Valve (Model 1000)

PRODUCT NEWS CAT.NO.-70 KPC CORPORATION FLOW CONTROL DIVISION

Thermal Shut-Off I. OVERVIEW OF THERMAL SHUT-OFF VALVES

International Standard Valve, Inc Perimeter Park Drive, Bldg 320, Houston, Texas Ball Valve Product Summary

Spring loaded Thermal Relief Safety Valves, manufacturers standard Medium and high pressure

GVI Series Industrial Globe Valves for Flow Control

Customized ELECTRO-HYDRAULIC CONTROL SYSTEM

RHINO VALVES WORLDWIDE. Series 44 ISO. Design of three pieces with plate disposition ISO 5211 for their automation.

* Contact your sales representative for compliance to NACE MR or later requirements.

CRYOGENIC. Italian Manufactured, Italian Quality

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

Worcester 18/19 Series. Modular Multi-Way Ball Valves

RESILIENT SEATED BUTTERFLY VALVES. Howell Valve & Automation. Toll Free: Howellvalve.com

Series 8000 Air Actuated Valves

Control Valves for General Applications

Sempell High Pressure Stop Valves Model VA500 (ASME)

AUMA. Boehmer. Conval. Conval. Dragon

Pressure Reducing, Differential and Back Pressure Regulating Valves Spring Loaded Dome Loaded Pilot Actuated

Bushing Viton O-ring (Other material available) Anti-Static Device

708MV Series Motor Valve

Pressure Reducing, Differential and Back Pressure Regulating Valves Spring Loaded Dome Loaded Pilot Actuated

Worcester Controls Directional Ball Valves

SchuF FETTEROLF SchuF / Fetterolf standard Type 32 sampling valves custom-built solutions

Design CP Control Valve with ENVIRO-SEAL Bellows Seal Bonnet

Instrumentation. Visit Us Online WE DO MORE THAN INDUSTRIAL. WE DELIVER TOTAL SOLUTIONS For Panel Fabricators

Test units for all types of: Shut-off Valves Safety (relief) Valves Control Valves

Worcester 18/19 Series. Modular Multi-Way Ball Valves

High Pressure Solenoid Valves

High Performance Butterfly Valves

GATE/GLOBE/CHECK VALVE, BALL VALVES, BUTTERFLY VALVES, KNIFE GATE VALVES, CONTROL VALVES and ACTUATION

Full Port ANSI Class 150 (2PC Body) Flanged End

Transcription:

FM FIRE-SAFE VALVE ASSEMBLIES & 90 ACTUATORS "F" "G" Meets API 607 Edition 3 and 4, Factory Mutual FM 7440 "F" "G" Assured Automation 19 Walnut Avenue Clark, NJ 07066 Tel: 800-899-0553 assuredautomation.com

Order Your Fire-Safe Thermal and Electro-Thermal Shutoff Valves Online! Assured Automation Makes it Easy to Configure, Price, and Buy at www.fmfiresafe.com 1 Select Ball Valve, Flanged Ball Valve or Butterfly Valve Body 2 Select Size and Material: Carbon Steel or Stainless Steel 3 Select Thermal Link and Fire Actuation Options 4 Save, Print, Email Quote and Checkout It s that easy. Get your quote today. FM Fire-Safe Thermal and Electro-Thermal Shutoff Valves: Fire-Safe Thermal Shutoff Valves provide automatic emergency shutdown to stop the flow of flammable or hazardous media during a fire or emergency. The complete ball valve and butterfly valve assemblies are Factory Mutual (FM) approved. Heat actuated, UL listed thermal links automatically shut off or open the valve at predetermined temperatures. A unique, removable handle allows the valve to be manually operated without affecting the fusible links. The Fire-Safe Shutoff Valve is completely self-contained and uses a spring return so no external electrical power or pneumatic pressure is required for operation. Two FM/UL-listed links are offered: a thermal and EA electrothermal to connect with a fire alarm panel for remote operation. Typical Safety Installation Sites: 1. Installed where fuel supply enters a building from an outside storage tank. The Fire-Safe can be alarm activated to stop the flow of fuel into the building whenever a fire occurs within the building. 2. Installed inside a firewall and alarm activated to pressurize water into sprinkler pipes to extinguish fire when the fire occurs outside a building.

TABLE OF CONTENTS Fire-Safe Ball Valve Assemblies Thermal...1 Fire-Safe Ball Valve Assemblies Electro-thermal...2 Fire-Safe Butterfly Valve Assemblies Thermal...3 Fire-Safe Butterfly Valve Assemblies Electro-thermal...4 Multi-Port Ball Valve Assemblies 3-Way...5 Spring-Return Handles...6 Custom Fire-Safe Valve Actuators...7 Fire-Safe Valves Equipment Uses...8 FM Fire-Safe valve assemblies and actuators in this catalogue are manufactured by Essex Industries

FIRE-SAFE BALL VALVE ASSEMBLIES THERMAL Thermal Link Assemblies Flanged A B C D E F G ½ 6.9 1.1 4.3 3.4 7.8 3.3 4.8 ¾ 7.0 1.3 4.3 3.9 7.8 3.3 4.8 1 7.4 1.7 5.0 4.3 7.8 3.3 4.8 1 ½ 10.0 2.1 6.6 5.0 10.0 4.3 5.3 2 10.2 2.3 7.0 6.0 10.0 4.3 5.3 3 12.1 3.5 8.0 7.5 10.0 4.3 5.3 4 12.6 4.0 9.0 9.0 18.0 4.3 5.3 Threaded / Socket & Butt-Weld A B C-TS C-BW D E F G ½ 6.9 1.1 2.6 2.4 2.1 7.8 3.3 4.8 ¾ 7.1 1.3 3.3 3.4 2.3 7.8 3.3 4.8 1 7.5 1.7 3.7 4.0 2.6 7.8 3.3 4.8 1 ¼ 9.7 1.8 4.3 4.6 2.9 10.0 4.3 5.3 1 ½ 10.0 2.1 4.6 5.5 3.4 10.0 4.3 5.3 2 10.2 2.3 5.2 6.0 3.7 10.0 4.3 5.3 Thermal Fire-Safe Ball Valve Assemblies are Factory Mutual (FM) approved and combine the characteristics of a manual ball valve with the added safety of an automatic shut-off. Heat actuated, U.L. listed thermal links automatically shut off or open the valve at predetermined temperatures. A unique, removable handle allows the valve to be manually operated without affecting the fusible links. The thermal fire-safe ball valve assembly, ranging in size from 1/4 to 4, is available in a variety of metals, including stainless steel, carbon steel, monel, Inconel, hastelloy B & C, alloy 20, copper and brass. All thermal links are U.L. listed and are available in the following temperatures: 165 F (74º C), 212 F (100º C), 286 F (141º C), 360 F (182º C) and 500 F (260º C). Fire-Safe Ball Valve Assemblies are available with the following connection configurations: threaded; socket-weld; butt-weld; and flanged. 90 "F" "G" Drawing Shown: Jamesbury 4000 Series 2 Threaded Thermal Link 1

FIRE-SAFE BALL VALVE ASSEMBLIES ELECTRO-THERMAL Electro-thermal Link Assemblies Flanged A B C D E F G ½ 6.9 1.1 4.3 3.4 7.8 3.3 4.8 ¾ 7.0 1.3 4.3 3.9 7.8 3.3 4.8 1 7.4 1.7 5.0 4.3 7.8 3.3 4.8 1 ½ 10.0 2.1 6.6 5.0 10.0 4.3 5.3 2 10.2 2.3 7.0 6.0 10.0 4.3 5.3 3 12.1 3.5 8.0 7.5 10.0 4.3 5.3 4 12.6 4.0 9.0 9.0 18.0 4.3 5.3 Threaded / Socket & Butt-Weld A B C-TS C-BW D E F G ½ 6.9 1.1 2.6 2.4 2.1 7.8 3.3 4.8 ¾ 7.1 1.3 3.3 3.4 2.3 7.8 3.3 4.8 1 7.5 1.7 3.7 4.0 2.6 7.8 3.3 4.8 1 ¼ 9.7 1.8 4.3 4.6 2.9 10.0 4.3 5.3 1 ½ 10.0 2.1 4.6 5.5 3.4 10.0 4.3 5.3 2 10.2 2.3 5.2 6.0 3.7 10.0 4.3 5.3 Electro-thermal Fire-Safe Ball Valve Assemblies are Factory Mutual (FM) approved at 165 F (74º C) and are equipped with an electro-thermal link that reacts when subjected to heat or to a lowpower electrical impulse. Sizes range from 1/4 to 4, and are available in a variety of metals, including stainless steel, carbon steel, monel, Inconel, hastelloy B & C, alloy 20, copper and brass. The operating range is 6-30 VDC or VAC. Requiring less than 0.2 amps of power,.5 ms at 24 V, the unit may be used with similar circuitry such as electrical signaling systems which are activated by heat, smoke, gas, flame-energy, maximum temperature or rate of temperature rise. Units are also available at 212 F (100º C) or 255 F (124º C) that are not U.L. listed. Fire-Safe Ball Valve Assemblies are available with the following connection configurations: threaded; socket-weld; butt-weld; and flanged. "F" "G" Drawing Shown: Jamesbury 7000 Series 3 & 4 Flanged Electro-thermal Link assuredautomation.com 2

FIRE-SAFE BUTTERFLY VALVE ASSEMBLIES THERMAL Approximate Dimensions (inches) A B C D E 3 14.6 7.5 1.9 2.9 13.0 4 15.1 9.0 2.1 3.8 13.0 Thermal Fire-Safe Shut-off Butterfly Valve Assemblies include an FM approved actuator on a fire-safe butterfly valve. They are designed to meet the requirements for plant applications where flammable fluids are piped and controlled, such as in the petroleum or process industries. When used in conjunction with high performance butterfly valves having a resilient/metallic seating arrangement, the patented Thermal Actuator (TA Series) has the ability to shut-off in the event of fire or a hazardous situation. Note: Butterfly Valves cannot be manually operated without removing the spring-loaded canister Valve Construction Materials: Cv Values (gpm) Valve Positions 22-½ 45 67-½ 90 3 13.2 36.3 82.5 165 4 32 88 200 400 Body: Carbon Steel or 316 Stainless Steel Disc: 316 Stainless Steel Shaft: 17.4 PH or 316 Stainless Steel Seal: TFE/316 Stainless Steel Shaft Seal: Graphite *Other body, disc shaft and seat materials are available. Drawing Shown: Jamesbury 8 F815L Butterfly Valve Thermal Link 3

FIRE-SAFE BUTTERFLY VALVE ASSEMBLIES ELECTRO-THERMAL Approximate Dimensions (inches) A B C D E 3 14.6 7.5 1.9 2.9 13.0 4 15.1 9.0 2.1 3.8 13.0 Electro-thermal Fire-Safe Shut-off Butterfly Valve Assemblies include an FM approved actuator with an electrothermal link added to the list of features of the thermal version. The electro-thermal link provides for a means of remote actuation typically achieved using a gas or smoke detector. Spare actuators can be purchased separately. Assembly and disassembly manuals are available upon request. Note: Butterfly Valves cannot be manually operated without removing the spring-loaded canister Valve Construction Materials: Body: Carbon Steel or 316 Stainless Steel Disc: 316 Stainless Steel Shaft: 17.4 PH or 316 Stainless Steel Seal: TFE/316 Stainless Steel Shaft Seal: Graphite Cv Values (gpm) Valve Positions 22-½ 45 67-½ 90 3 13.2 36.3 82.5 165 4 32 88 200 400 *Other body, disc shaft and seat materials are available. Drawing Shown: Jamesbury 8 F815L Butterfly Valve Thermal Link assuredautomation.com 4

MULTI-PORT BALL VALVE ASSEMBLIES 3-WAY 3-Way Multi-port Ball Valve Assemblies are fusible link actuators designed for use on 3-way multi-port ball valves. Capable of reacting to heat, smoke or gas leaks, this system will shut off and vent the air supply to a pneumatic spring return actuator allowing it to close larger fire-safe valves. L-Port 90, FLOW PLAN A POSITION 1 POSITION 2 (OPEN) (FAIL) Choose from one of the flow plans below or call for alternative patterns to meet specific application needs. Available valve sizes: 1/4, 3/8, 1/2, 3/4, 1, 1 1/4, 1 1/2 and 2. T-Port 90, FLOW PLAN B POSITION 1 POSITION 2 (OPEN) (FAIL) Features All stainless steel valve construction 800 WOG rating Threaded ends Standard port Closing temperatures - 165 F (74 C), 212 F (100 C) and 286 F (141 C) T-Port 90, FLOW PLAN C POSITION 1 POSITION 2 (OPEN) (FAIL) 5

SPRING-RETURN HANDLES Spring-Return Handles provides reliable automatic closing/opening of manual ball valves. The handles may be held in the operating position and the spring will automatically return the valve to the fail position upon release. They can be mounted for either spring-toclose or spring-to-open operation. The spring is housed in a steel enclosure and provides quick cycling of the valve to the fail position upon release of the handle. Sizes range from ¼ to 4 and are available in Threaded, Socket-Weld, Butt-Weld, and Flanged. Available Valve Sizes SA0001X SA0002 SA0003X ¼ -1 1¼ -2 2½ -4 * * 4 Valve not available in Full Port configurations. assuredautomation.com 6

CUSTOM FIRE-SAFE VALVE ACTUATORS Custom Fire-Safe Valve Actuators are available using customer supplied fire-safe valves*. The actuators retain FM approval and can be purchased as an accessory to the fire-safe valve. This maintains equipment consistency throughout the application. Thermal Electro-thermal Applications Ball TA0001X EA0001X ¼ -1 ** Ball TA0002X EA0002X 1¼ -2 ** Ball TA0003X EA0003X 2½ -4 ** Butterfly TA0003XBF EA0003XBF 2-4 *** * Valve must be soft seated and either API607 or FM fire rated. **Actuator sizing and price determined by valve torque. ***Butterfly valves priced by torque. Call for more information. Examples shown are for informational purposes only. 7

FIRE-SAFE VALVES EQUIPMENT USES Fire-safe valves and emergency breathing equipment prove useful throughout industrial applications. From process to production, this equipment protects people and products during emergency situations. Boiler valve/utility room. For prevention of fuel flow from boiler to furnace during an emergency. Structure Entry. Valve used in two positions to stop flammables from entering structure during emergency. Interim Storage Tanks. Can be dumped to another location to prevent an explosion. Off-load Truck. Prevent flammables from being dumped from process lines to the environment. Plant. Use on process lines to help prevent local damage and loss of equipment. assuredautomation.com 8

90 "F" "G" "F" "G" Assured Automation 19 Walnut Avenue Clark, NJ 07066 Tel: 800-899-0553 assuredautomation.com