NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Similar documents
INSTALLATION AND OPERATION MANUAL

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES,

BMRX Series ROTARY LEVEL CONTROL

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

LED STRIP LIGHTING KIT EUKT04 WW30

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL

10 S e r i e s PRESSURE SWITCH. features

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

EStrong-series Emergency Stop

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

INSTALLATION INSTRUCTIONS

Benchmark HD Series Heavy Duty Bench Scale. Installation Manual

SETRA Operating Instructions Series DPT 230 Pressure Transducers

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

AUTOMATION. Operator s Manual. NLS Series. Pneumatic Level Sensors. Rev. A1, 4/07

INSTALLATION & OPERATION MANUAL

Installation and Service Instructions for EX Series Explosion-proof Switches

Air Curtain. Installation, Operating and Maintenance Instructions

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Easytork Solenoid Valve IOM

SPC-PANEL Simplex, Single Phase Pump Control Panel

Heavy Duty Industrial Foot Switches

80PK-2A Type K Immersion Probe

Operating and Installation Instructions

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

INSTALLATION INSTRUCTION & OWNER S MANUAL

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Warner Electric UNIBRAKE Motor Brakes

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

J 6 Se r i e s. Pressure and Vacuum switches. features

STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way

Installation and Maintenance Instructions 44TA Liquid Level Float Switch

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180

SERIES 9000 Double Offset HP Butterfly Valves

Safety Sentry Electronic Breakaway Switch

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Preassembled Clutch/Electrically Released Brake Module

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Installation Manual DIAPHRAGM WELL TANK

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

SOLAR DASH CHARGING SYSTEM USER GUIDE

Preassembled Clutch/Brake Module

Straight-Bore Clutch LSCC-32, 44, 54

Electric Actuator Installation, Operation & Maintenance Manual

SUNC3000 / Item #40885

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

SFP-250 and SFP-400. Installation Instructions. An Altra Industrial Motion Company P-231-WE

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

Installation & Operation Manual. Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models

Compressor Clutch Replacement Procedure

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

Electromagnetic Particle Brakes Model: PRB-H

Model Combustible Gas Sample Draw Detector Head Operator s Manual

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

Mechanical Physician Scale Installation & Operation Instructions PN

Pump Installation and Service Manual HRS Hydromatic Retractable System

SERIES 1000 ELECTRIC ACTUATORS

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

MODEL DX Pneumatic Diaphragm Actuator


MODEL L-8 HARWIL CORPORATION 541 KINETIC DRIVE, OXNARD, CA TEL: (805) FAX: (805)

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

StormPro BA Series Sump Pump

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

Owner s Manual Nitrate Series Salt Based Filter System

SERIES 740 VALVES PNEUMATIC DIRECTIONAL CONTROL

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier

Installation Instructions for Eaton Surge Protective

MODEL TC400 TIRE CART. Installation, Operation & Repair Parts Information REV P/N:

Switch-Pak. AU13, AV13 & AZ13 Series Owner s Manual. w/ Compact Relay Controller

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids.

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

TB Series Brakes Tension Control System

Model Combustible Gas Sample Draw Detector Head Operator s Manual

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

2SHE Series Direct-Drive Shutter Fans

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Utility Controller Hand Air Operated

Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL Manual Part No

Installation and Operating Manual

Transcription:

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH INSTALLATION AND OPERATION MANUAL PN 610-0006 Rev E

WARNING CAUTION SPECIAL CONDITIONS FOR SAFE USE NOTE Manual No. 610-0006 Rev E Neo-Dyn 28150 Industry Drive Valencia, CA 91355 Tel: (661) 295-4000 Fax: (661) 294-1750 World Wide Web: www.neodyn.com Copyright 2002 ITT Important Information The product warranty applicable to this ITT Neo-Dyn instrument is as stated on page 17 of this manual. Should any after-delivery problems arise, please contact ITT Neo-Dyn s Customer Service using the information above. Our normal business hours are weekdays, 7:00 am to 3:30 pm, Pacific Time. Before installing this Adjustable Pressure Switch, become familiar with the installation and adjustment instructions in Chapters 2 and 3. Indicates a hazard, which can cause severe personal injury, death, or substantial property damage if the warning is ignored. Indicates a hazard, which will or can cause minor personal injury or property damage if the caution is ignored. The electrical wiring must be connected to the switch by means of conduit or flameproof cable gland certified to EN 50018. The electrical wiring must be 105 C rated minimum copper conductors only. If replacement of the setscrew that secures the threaded cover of the electronics housing is necessary, it must be replaced with a 0.138-32 UNC-2A (6-32) Hex Socket Head Cap Screw, 300 series CRES or CAD Plated Grade 5 Steel. Indicates additional information about a particular item necessary to the operation of the unit. This document contains proprietary information, which is the property of Neo-Dyn, a unit of ITT Industries. This document may not be reproduced, either in part or in full, without the consent of ITT Industries. 100P Enclosure 7 Adjustable Pressure Switch Page i

TABLE OF CONTENTS PAGE CHAPTER 1 INTRODUCTION... 2 CUSTOMER SERVICE... 3 CHAPTER 2 INSTALLATION... 4 MOUNTING... 4 PRESSURE CONNECTION... 4 ELECTRICAL CONNECTIONS... 5 CHAPTER 3 ADJUSTMENTS AFTER INSTALLATION... 8 ADJUSTMENTS... 8 CHAPTER 4 TROUBLESHOOTING... 10 CHAPTER 5 SPECIFICATIONS... 12 STANDARD... 12 OPTIONS... 16 WARRANTY INFORMATION... 17 100P Enclosure 7 Adjustable Pressure Switch Page ii

100P Enclosure 7 Adjustable Pressure Switch Page 1

CHAPTER 1 INTRODUCTION The Neo-Dyn Model 100P Enclosure 7 Adjustable Pressure Switch is an explosion-proof, electromechanical pressure switch designed for a wide range of applications in pneumatic and hydraulic systems up to 3,000 psig. The most common wetted materials include a polyimide (Kapton) sensing diaphragm, nitrile O-ring, and aluminum alloy or corrosion resistant steel (CRES) pressure port. CRES diaphragms and all-welded construction are also available for corrosive pressure media. Setpoint adjustments are easily made through the adjustable range of the Pressure Switch using either the increasing or decreasing handles. These handles are accessed by removing the unit s front cover. Model 100P Enclosure 7 may be ordered to switch 125 to 600 VAC, or 28 to 125 VDC, with currents from microamperes to 15 amperes. 100P Enclosure 7 Adjustable Pressure Switch Page 2

ADJUSTMENT HANDLES PLUGGED CONDUIT FITTING TERMINAL BLOCK GROUND 600 PRESSURE PORT 500 600 400 CONDUIT FITTING GROUND RANGE SCALE 080-0876P Figure 1. Model 100P Enclosure 7 Adjustable Pressure Switch for Hazardous Locations The standard electrical conduit connections are ¾ - 14 NPT female. The standard pressure connection is either a ¼ - 18 or ½ -14 NPT female port; see Chapter 2. Chapter 4 on page 12 contains complete specifications for the 100P Enclosure 7 Adjustable Pressure Switch. CUSTOMER SERVICE If you have any questions about the 100P Adjustable Pressure Switch that are not covered in this manual, you can contact Neo- Dyn in several ways. The customer service phone number is (661) 295-4000. Our customer service department is open from 7:00 am to 3:30 p.m. Pacific Time. Our Internet site is www.neodyn.com. 100P Enclosure 7 Adjustable Pressure Switch Page 3

CHAPTER 2 INSTALLATION WARNING WARNING WARNING WARNING Installation of Model 100P Enclosure 7 is straightforward. However, this Adjustable Pressure Switch must be installed by a qualified electrician, in compliance with all local and national electrical codes. Electrical Hazard Do not make electrical connections while power is on. Always check for multiple circuits. Always make sure grounding is adequate. MOUNTING The Adjustable Pressure Switch can be mounted directly to the pressure connection if there is no significant vibration and the pressure lines are capable of supporting the weight, or it can also be attached to a flat surface, such as a wall. Space the Range 1 unit at least.375 inch (0.95 cm) from the mounting surface, or allow the pressure fitting to overhang an edge of the mounting surface. PRESSURE CONNECTION The standard pressure inlet for model 100P Pressure Switches is either a ¼ - 18 NPT female pipe thread for Wetted Material 1 (aluminum alloy port), or ½ - 14 NPT female pipe thread for Wetted Materials 4, 5, 7 and 9 (CRES port). When installing the 100P Adjustable Pressure Switch always: 100P Enclosure 7 Adjustable Pressure Switch Page 4

CAUTION WARNING Make sure that the unit and your system have matching threads. Use the wrench flats provided. Seal all joints with pipe joint sealing compound. Avoid excessive torque on all threaded connections. Do not exceed the marked Maximum Operating Pressure in normal operation. The marked Proof Pressure is provided to give the maximum allowable pressure without causing permanent damage to the pressure switch in the event of an over-pressure condition. Set pressure relief/safety valves below this setting. ELECTRICAL CONNECTIONS One terminal block is located on the inside of the unit. Electrical connections are made through either of the two ¾ -14 NPT conduit openings. Model 100P Enclosure 7 is shipped from the factory with a threaded plug in one of these conduit openings. This plug is suitable for use in hazardous locations. All field wiring for Model 100P must comply with requirements of the NEC or applicable local electrical codes, including wire gauges and insulation temperature ratings. Conduit seals may be required. With no power to the wires, remove the unit s cover, move the insulator flap to the side (exposing the terminal block), and connect the wires to the terminal block. (See Figure 1.) There are three ways of wiring model 100P Enclosure 7, depending on which Electrical Form the unit is; Figure 2 shows the electrical schematics for Forms CC, C, and Z. NOTE On forms C and CC, it is not mandatory to connect both NC and NO wires to the switch. Return the the insulator flap to its position over the terminal block. If the setpoints are not to be adjusted at this time, reinstall the unit s cover, making sure that it is bottomed and compressing its O-ring. 100P Enclosure 7 Adjustable Pressure Switch Page 5

INC P INC P INC P NC1 NC1 C1 NO1 NC2 C2 NO2 C1 NO1 NC NC NO NO GREEN SCREW GREEN SCREW GREEN SCREW FORM CC (DPDT) FORM C (SPDT) FORM Z 080-0875P Figure 2. Schematics Shown at Zero PSIG 100P Enclosure 7 Adjustable Pressure Switch Page 6

100P Enclosure 7 Adjustable Pressure Switch Page 7

CHAPTER 3 ADJUSTMENTS AFTER INSTALLATION WARNING This section describes the adjustments needed after the Adjustable Pressure Switch has been properly installed. Pressure settings are internally adjustable using the adjustment handles. Never remove the cover in a hazardous environment with the power on. ADJUSTMENTS 1. It is recommended that the unit be in a non-hazardous location during adjustment. 2. Disconnect the electrical power. Check for multiple circuits. 3. Remove the access cover. Lift the insulator flap that contains the adjustment diagram, exposing the adjustment handles. 4. To change the setpoint, the adjustment spring handles can be manipulated by hand or with a small-shafted screw driver or similar tool inserted into the end of the desired handle. The handle for decreasing the setpoints is next to the housing wall adjacent to the pressure port; the other handle, closer to the center of the housing, increases the setpoints. See Figure 1. 100P Enclosure 7 Adjustable Pressure Switch Page 8

CAUTION 5. Rock the appropriate handle back and forth, to rotate the adjustment nut to increase or decrease load on the internal adjustment spring. The silver-colored range scale, visible past the end of the adjustment nut, gives an approximate value of the increasing setpoint. For precise adjustment of the increasing or decreasing setpoint, check the setpoints with a calibrated pressure gauge. 6. To check the setpoint, connect a pressure source (and a calibrated pressure gauge if desired) to the pressure port and slowly apply increasing pressure until the switch actuates. Actuation can be noted by listening to the audible snap of the Belleville spring, or with an ohmmeter across the appropriate terminals of the terminal block. 7. If you want to check the decreasing setpoint, slowly decrease the pressure after the switch has actuated and note the pressure at which the audible snap or ohmmeter indicates deactuation. Deadband may be calculated if desired by subtracting the decreasing setpoint pressure from the increasing setpoint pressure. Replace the cover onto the unit and tighten it until it is snug against the O-ring. Do not overtighten the cover, as this can make it difficult to remove later. 8. Tighten the setscrew. 100P Enclosure 7 Adjustable Pressure Switch Page 9

CHAPTER 4 TROUBLESHOOTING In-service problems are unlikely, but the following paragraphs suggest ways to verify any problems that might arise: 1. Leaks If a leak is suspected, connect the pressure switch and a calibrated pressure gauge downstream from a pressure source and shutoff valve. Apply normal system pressure, isolate the gauge and Pressure Switch from the pressure source with the shutoff valve for at least one minute, and check for leaks as evidenced by a drop in the gauge reading. Leaks may be repaired by replacing the sensing diaphragm and O-ring (wetted materials 1 and 4 only). Contact ITT for replacement parts and instructions, or return the unit to ITT for this repair. 2. Failure to Switch If application of pressure 10% greater than the adjusted setpoint fails to produce actuation, first check for contamination in the pressure line, and verify that pressure is reaching the sensing diaphragm. If the Belleville spring can be heard to audibly snap, but an ohmmeter indicates no electrical switching, the cause is probably stuck or burned switch contacts, and the switch element needs to be replaced. Return the unit to ITT for this repair. 100P Enclosure 7 Adjustable Pressure Switch Page 10

If application of pressure 10% greater than the adjusted setpoint fails to produce an audible snap of the Belleville spring, there is probably a mechanical failure or binding due to contamination. Return the unit to ITT for repair. 3. Calibration Shifts If it is suspected that the setpoints have shifted, recheck them per paragraphs 6 and 7 of Chapter 3. If you verify unstable or drifting setpoints, return the unit to ITT for repair. 100P Enclosure 7 Adjustable Pressure Switch Page 11

CHAPTER 5 SPECIFICATIONS This section shows the standard specifications and available options for the 100P Adjustable Pressure Switch. STANDARD Interface The Model 100P Enclosure 7 weighs approximately 4 pounds (1.8 kg). ¾ - 14 NPT Conduit Connections ¼ 18 or ½ - 14 NPT Female Pressure Port Temperature Range Ambient: -40 F (-40 C) to +167 F (+75 C) Media: -40 F (-40 C) to +300 F (+149 C) Listing Agency Approvals UL CSA ATEX CE Mark 100P Enclosure 7 Adjustable Pressure Switch Page 12

Part Number The part number contains information about which configurations and options are included in your Adjustable Pressure Switch. To determine the pressure range, electrical rating, and options, compare the part number of your unit with the information below in Figure 3. 100P 1 2 CC 7 BM Model Series Wetted Material Range Number Electrical Form Explosion Proof Housing Options Figure 3. Part Number Breakdown Pressure Ratings Part No Range No Table 1 Max Operating Pressure, psig (bar) Proof Pressure PSIG (bar) 100P*1*7* 1 600 (41.37) 1000 (68.95) 100P*2*7* 2 3000 (206.85) 5000 (344.8) 100P*4*7* 4 3000 (206.85) 5000 (344.8) 100P*5*7* 5 3000 (206.85) 5000 (344.8) 100P*7*7* 7 3000 (206.85) 5000 (344.8) 100P*8*7* 8 3000 (206.85) 5000 (344.8) * See Figure 3 above for part number breakdown 100P Enclosure 7 Adjustable Pressure Switch Page 13

Actuation Points Range No Table 2 Adjustable Set Point Range PSIG (KPAG) Increasing, psig (bar) 1 5 to 75 (0.35 to 5.2) 2 15 to 150 (1.0 to 10.3) 4 50 to 300 (3.4 to 20.7) 5 125 to 600 (8.6 to 41.4) 7 500 to 1500 (34.4 to 103.4) 8 800 to 2800 (55.2 to 193.1) Wetted Materials Decreasing, psig (bar) 2.3 to 73.3 (0.15 to 5.0) 9 to 144 (0.6 to 9.9) 36 to 286 (2.5 to 19.7) 100 to 575 (6.9 to 39.6) 440 to 1440 (30.3 to 99.3) 675 to 2675 (46.5 to 184.4) Deadband Approx., psi (bar) 2.7 (0.2) 6 (0.4) 14 (1) 25 (2) 60 (4) 125 (9) No Table 3 Description 1 Aluminum alloy port, teflon coated polyimide (Kapton) diaphragm and nitrile O-ring 4 UNS S31600 CRES port, teflon coated polyimide diaphragm and nitrile O-ring. 5 UNS S31600 CRES port and diaphragm, heliarc welded. 9 Monel port and inconel diaphragm, heliarc welded; not offered in range 1 100P Enclosure 7 Adjustable Pressure Switch Page 14

Explosion Proof/ Weather Proof Ratings: Class I, Div 1, Groups C and D Class II, Div 1, Groups E, F and G Class III, Div 1 Ex d II B T6 Gb Ex tb IIIC T85 C Db, IP65 Enclosure type 4X, 13 (NEMA) Electrical Ratings Form C (SPDT) 15 amp at 125, 250, or 480 VAC, 2 amp at 600VAC, 1/8 hp at 125 VAC, ¼ hp at 250 VAC,.5 amp resistive,.04 amp inductive at 125 VDC. Form CC (DPDT): 11 amp and ¼ hp at 125 or 250 VAC, 5 amp resistive, 3 amp inductive at 28 VDC,.5 amp resistive at 125 VDC. Form Z (Double Break): 15 amp at 125, 250, or 480 VAC, ¼ hp at 125 VAC, 1/2 hp at 250 VAC, 1 amp resistive,.5 amp inductive at 125 VDC. Form C or CC with M option 1 amp at 125 VAC 100P Enclosure 7 Adjustable Pressure Switch Page 15

OPTIONS The available options are listed below. You can combine these options, but every option ordered should be indicated in the part number of the unit. Option B C E F M S W Table 4 Description Viton O-Ring Refer to Wetted Materials EPR O-Ring Refer to Wetted Materials 7/16 20 SAE Port (Wetted Material 1 Only) Fire Fuse For Fire Tested Equipment (Wetted Materials 4 and 5 only) Gold Electrical Contacts For Extremely Low Current Applications Corrosion-Resistant Steel Diaphragm (Wetted Material 4 Only) Corrosion-Resistant Steel Screws Exterior (Standard on Wetted Materials 4, 5 and 9) 100P Enclosure 7 Adjustable Pressure Switch Page 16

WARRANTY INFORMATION A. Warranty: ITT Industries (ITT) warrants that at the time of shipment, the products manufactured by ITT Neo-Dyn and sold hereunder, will be free from defects in material and workmanship and will conform to the specifications furnished or approved by ITT. B. Warranty Adjustment: If any defect within this warranty appears, the Buyer shall notify ITT immediately. ITT agrees to repair or furnish a replacement for, but not install, any product which, within one (1) year from the date of shipment by ITT shall, upon test and examination by ITT, prove defective within the above warranty. No product will be accepted for return or replacement without the written authorization of ITT. Upon such authorization, and in accordance with instructions by ITT, the product will be returned with shipping charges prepaid by the Buyer. Replacements made under this warranty will be shipped prepaid. C. Exclusion from Warranty: THE FOREGOING WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER EXPRESSED OR IMPLIED WARRANTIES OF MERCHANTABILITY, OR FITNESS, OR OTHERWISE. Components manufactured by any supplier other than ITT shall bear only the warranty made by the manufacturer of that product, and ITT assumes no responsibility for the performance or reliability of the unit as a whole. In no event shall ITT be liable for indirect, incidental or consequential damages nor shall the liability of ITT arising in connection with any products sold hereunder (whether such liability arises from a claim based on contract, warranty, tort or otherwise) exceed the actual amount paid by Buyer to ITT for the products delivered hereunder. The warranty does not extend to any product manufactured by ITT, which has been subject to misuse, neglect, accident, improper installation, or to use in violation of instructions furnished by ITT. The warranty does not extend to or apply to any unit, which has been repaired or altered at any place other than at ITT s factory or service locations, by persons not expressly approved by ITT. 100P Enclosure 7 Adjustable Pressure Switch Page 17