Utility Vehicle Flamethrower Apparatus

Similar documents
Project Number 56b January Hard Cab Design for HMMWV

EVALUATION OF THE AQUA-DUK PUMP

Comparison of 1½- and 2-Inch Suction Hose When Used With Portable Pumps. David V. Haston, P.E., Mechanical Engineer

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 12 Wildland Back Fire Burn Out Revised

Utilization of Associated Gas to Power Drilling Rigs A Demonstration in the Bakken

North Lyon County Fire Protection District. Seasonal Firefighter Job Description

Voluntary Specification for Determining Forced Entry Resistance of Side-Hinged Door Systems

Distillation. How you can benefit from the future of biodiesel

Merv Eriksson Project Leader. Sharon Kosmalski Project Assistant. July 2006

MEMORANDUM. Proposed Town of Chapel Hill Green Fleets Policy

Electric Vehicle Cost-Benefit Analyses

The Realities of Consumer-Owned Wind Power For Rural Electric Co-operatives

CUCAMONGA VALLEY WATER DISTRICT FLEET AND EQUIPMENT MECHANIC I/II

FAST EISA Section 246 Infrastructure Reporting FAQ

Vehicle Disabling Systems

Scale Manufacturers Association. Standard. Vehicle Scale Characterization (SMA VCS-1102)

(2) An engine subject to this rule or specifically exempt by Subsection (b)(1) of this rule shall not be subject to Rule 68.

Choctaw Nation of Oklahoma Fleet Safety Program

Municipality Generator Interconnection Application Single Meter Application Part I

BIODIESEL END-USER SURVEY: IMPLICATIONS FOR INDUSTRY GROWTH FINAL REPORT OUT

Hurricane Andrew Photovoltaic Traffic Control Relief Preliminary Report

Georgia Department of Revenue Policy Bulletin - MVD HB 170 Transportation Funding Act of 2015

Program of Instruction Course Syllabus

UNITED STATES DEPARTMENT OF AGRICULTURE FOREST SERVICE STANDARD FOR SPARK ARRESTERS FOR INTERNAL COMBUSTION ENGINES

INVITATION TO BID. Should you need clarification on any item, please contact Berley Mears, Public Works Director at

April 24, Docket No. CPSC

Emergency Services Guidance for Competition Electric Vehicles

MISSING PARTS??? call Extang at

Voluntary Specification for Determining Forced Entry Resistance of Side-Hinged Door Systems

MANUAL: Foam Attachments for TFT Nozzles

A Study of LUCAS* Semi- Synthetic 2-Cycle Oil in ECHO* String Trimmers

5.1 Design and Install Dispenser Transfer Systems Performance Based Skill Assessments 2019

ETA-TP008 Revision 2 Effective March 1, Battery Charging

MMP Investigation of Arthur Kill 2 and 3

2011 NDIA GROUND VEHICLE SYSTEMS ENGINEERING AND TECHNOLOGY SYMPOSIUM POWER AND MOBILITY (P&M) MINI-SYMPOSIUM AUGUST 9-11 DEARBORN, MICHIGAN

Frequently Asked Questions

This document is a preview generated by EVS

Rapid Shrink 100. Owner s Manual

Electronic On-Board Recorders and Hours of Service Supporting Documents. AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT.

MANUAL: Foam Attachments for TFT Nozzles

Small generators frequently are used in remote sites and

Voltmaster Centrifugal Trash Pumps

PLANNING TO START OR EXPAND A BUSINESS?

Motor Pool Vehicle Use Policy

Roscommon Equipment Center Northeast Forest Fire Supervisors in Cooperation with Michigan s Forest Fire Experiment Station

PowerMax. Power Distribution System. Operation Manual Version 1.0 Copyright 2003 Professional Sound Corporation Printed in the U.S.A.

Photo credit: Vanessa Bauman

A leading engineering & scientific consulting firm dedicated to helping our clients solve their technical problems.

New Ultra Low Sulfur Diesel fuel and new engines and vehicles with advanced emissions control systems offer significant air quality improvement.

GROUP WORKING WORKING PAPER. International FIRST MEETING. related tests SUMMARY. 1.1 independent. The DGP also may 1.2. The report, strategies. 1.

Carbon management in the Norwegian defence sector: Measures to meet national and defence environmental goals

Utilizing Crash Data Performance Metrics to Drive Improvement

Tax and Revenue Administration (TRA)

Insights on the statistical variability of experimental fire behavior data using airborne-infrared. infrared

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA

Hiab XS 435 K Capacity 280,200 ft-lbs

The Director, Purchasing and Materials Management recommends that:

Vehicle Extrication. by Dave Dalrymple

TANK RISER SUSPENSION SYSTEM CONCEPTUAL DESIGN (U)

SGS North America, Inc.: Grant of Expansion of Recognition. AGENCY: Occupational Safety and Health Administration (OSHA), Labor.

Airtanker. Drop Guides. Ground Pattern Performance of the Erickson Air Crane Paul Solarz, Program Leader, and Cammie Jordan, Project Assistant

June Safety Measurement System Changes

DEFENSE AGENCIES Fleet Alternative Fuel Vehicle Acquisition Report Compliance with EPAct and E.O in Fiscal Year 2008

Gaining Independence on the Road

Evaluation of Visibility From Powered Industrial Trucks

FIRE ATTACK STRATEGIES

System Integration of an Electronic Monitoring System in All-Terrain Vehicles

Sacramento Municipal Utility District s EV Innovators Pilot

1/2 Socket Wrench 3/16 Allen Wrench

Fixed Ladder: A ladder that cannot be readily moved or carried because it is an integral part of a building or structure

North Central Texas Wildland Fire Working Group. Regional Response Guidelines

SFI SPECIFICATION 3.2A EFFECTIVE: APRIL 20, 2018 *

Requesting a Fire Hydrant PROCEDURE FM M 0003

OUTLINE: MVR PSP WHAT IS IT? WHAT INFORMATION IS ON IT? WHY DO WE NEED THIS INFORMATION? HOW CAN I GET IT? HOW MUCH DOES IT COST?

S&S. Installation Instructions: S&S Billet Air Cleaner Kit PN for Victory Motorcycles. Instruction IMPORTANT NOTICE:

Subject: Emissions Recall 23V1 Approved Emissions Modification for Model Year Volkswagen Touareg 3.0L TDI

An Introduction to Automated Vehicles

. Los Angeles International Airport Rules and Regulations SECTION 09 FUELING

Spring Training 2015 Wildland Fire Training

Airtanker. Drop Guides. Ground Pattern Performance of the Western Pilot Services Dromader. Figure 1 39% 4 7/8 x 3 Original Photo 9.25 x 6.

The National Association of State Motorcycle Safety Administrators (SMSA) Strategic Plan

RICanada Comments on the British Columbia Greenhouse Gas Reduction (Renewable and Low Carbon Fuel Requirements) Act and the Renewable and Low Carbon

Managing Electrical Safety on Boats

Environmental Standard Operating Procedure (ESOP) Originating Office: Natural Resources and Environmental Affairs (NREA) Office

Pothole Patching Solutions

ECHO* String Trimmer Technical Study

Baghouse Conversion to Pleated Filter Elements From Standard Bag and Cage Setup - Cost Benefit Analysis

EVENING PROGRAM DESCRIPTIONS. California State Smog Repair Technician

Multi-Stage Selective Catalytic Reduction of NO in Lean-Burn Engine Exhaust. B. M. Penetrante M. C. Hsiao B. T. Merritt G. E.

NaturaFill: Fuel for Thought

HV angle valve with single acting pneumatic actuator and closing spring (NC)

SAFETY COMPLIANCE TESTING FOR FMVSS 225 Child Restraint Anchorage Systems

[Docket No. FAA ; Directorate Identifier 2008-SW-44-AD; Amendment ; AD ]

Q1.This question is about the temperature of the Earth s atmosphere. Give one reason why it is difficult to produce models for future climate change.

AMWPro75 Motor Adapter Instructions

Hybrid & Electric Cars Guidance for organisers of Speed events

RC COMPANY PROFILE

MODEL CR25M Manual Cable Beam Barrier

PROPOSED HEAVY-DUTY VEHICLE AND ENGINE GREENHOUSE GAS EMISSION REGULATIONS UNDER CEPA, 1999

FEDERAL SPECIFICATION METHANOL (METHYL ALCOHOL) 1.1 Scope. This specification covers three grades and four unit quantities of methanol.

Transcription:

NewsNote #18 August, 2014 Utility Vehicle Flamethrower Apparatus National Association of State Foresters in Cooperation with Michigan s Forest Fire Experiment Station 1

REC NewsNote No. 18 Utility Vehicle Flamethrower Apparatus Table of Contents Disclaimer...2 Introduction...3 Design...4 Appendix A...5 Roscommon Equipment Center c/o Forest Fire Experiment Station 1337 East Robinson Lake Road P.O. Box 68 Roscommon, Michigan 48653 Telephone: (989) 275-5211 Fax: (989) 275-8249 Email: info@roscommonequipmentcenter.org Web Site: www.roscommonequipmentcenter.org Disclaimer This report has been developed for the guidance of member States, Provinces, Federal Agencies and their cooperators. The National Association of State Foresters and the State of Michigan assume no responsibility for the interpretation or use of this information. The use of trade, firm or corporation names is for the information and convenience of the user. Such use does not constitute an official evaluation, conclusion, recommendation, endorsement or approval of any product or service to the exclusion of others, which may be suitable. 2

Introduction Michigan is a state with many less accessible areas and the Michigan Department of Natural Resources (MI DNR) has invested in developing a flamethrower unit as a tool to help meet the objectives of their prescribed burning efforts. Safe and reliable ignition of different fuel types in difficult to traverse terrain is vital to wildland firefighters during prescribed burning operations. The MI DNR's flamethrower's ability to project burning matter while creating a high intensity sustained heat some distance away from the wildland firefighter is beneficial to reach remote pockets of fuels regardless of whether those fuels are wetland fuels or sparse vegetation that are intended to be consumed during a prescribed burn. 3

Design To develop the plans, the REC staff worked directly with Michigan's Forest Fire Officers' to fully understand their tactical & logistical needs for this device. REC staff members participated in several prescribed burns to validate the device and collect end user comments regarding the usage of the flamethrower. The flamethrower device that was developed is a direct result of many hours of field usage and close interaction with MI DNR field staff. The flamethrower device is powered by an auxillary gasoline driven engine and pumping arrangement that Michigan has made able to be fastened down & transported in a utility vehicle with a rear cargo bed. This pump arrangement is built upon a fabricated metal pallet that gives it a "slip-on" type configuration which allows the unit to be movable and able to be used on multiple utility type vehicles. The flamethrower device is intended to be operated with two qualified individuals. Maintaining good visual & verbal communication, one person slowly drives the utility vehicle carrying the pumping unit along the intended fireline and the second individual carries & uses the flamethrower wand for ignition. The design of this device includes several safety features such as a handheld fire extinguisher, noise deflecting shielding and an automatic flamethrower wand extinguishing system. The flamethrower wand automatic extinguishing system is comprised of a hinged door on the flame holding end of the flamethrower wand and a carbon dioxide delivery system. Both of these systems are controlled and operated by the release of a "tether" cable. (similar tethering systems are commonly built into most treadmill machines found on the market today. These are designed to stop the machine in case of a fall while exercising). Simply put, when fitted correctly and in the event that the flamethrower wand operator drops the wand while igniting the fireline, the hinged door will close and a pulse of CO2 gas will extinguish the flameholding end of the flamethrower. The fuel that the flamethrower device "shoots" or projects outward is Michigan DNR's standard drip torch fuel. This is a mixture of liquid gasoline and diesel fuel in a mixture of 1/3 part gasoline to 2/3 parts diesel fuel. Ignition of the projected fuel is accomplished by setting the diesel fuel soaked "wick" aflame with a propane torch and then operating the flamethrower wand to project the drip torch fuel across the wick flame. Appendix A includes pictures of the flamethrower device that was developed. 4

Appendix A 5

Further Information For further information regarding this or any other REC product, please contact the REC Program Administrator at: Roscommon Equipment Center c/o Forest Fire Experiment Station 1337 East Robinson Lake Road P.O. Box 68 Roscommon, Michigan 48653 Telephone: (989) 275-5211 Fax: (989) 275-8249 Email: info@roscommonequipmentcenter.org Web Site: www.roscommonequipmentcenter.org