AC Leak Freeze AC Leak Freeze permanently seals leaks in air conditioning and refrigeration systems Will continue to seal additional Leaks for up to 1 year that meet testing specifications Does not contain polymers Not activated by moisture or oxygen Tested to be non-clogging to A/C compressor and recovery unit Ideal for preventive maintenance and leak protection OEM approved Patent pending 2
3 AIR CONDITIONING
Maximum load: 200kgs USE for 000-24000 BTU A/C TH-MSB REGULAR BRACKET KIT 450mm x 365mm x 1.8mm maximum load: 0kgs USE for 9000-000 BTU A/C 4
Maximum load: 200kgs USD for 000-24000 BTU A/C TH-MSBP premium BRACKET KIT 550mm x 500mm x 2.0mm maximum load: 200kgs USe for 000-24000 BTU A/C 5
6
7 AIR CONDITIONING
STT-5 STT-6 Hard Start Kits STT-5 START ASSISTANT INCREASES STARTING TORQUE UP TO 300%. STT-6 START ASSISTANT INCREASES STARTING TORQUE UP TO 500%. SPECIALLY DESIGNED FOR AIR CONDITIONING EQUIPMENT FROM 1/2HP TO 10HP. TO BE USED IN ONE PHASE EQUIPMENT WITH VOLTAGE SUPPLY FROM 120VAC UP TO 288VAC 50/60HZ. COMPATIBLE WITH ANY EQUIPMENT SPECIFICATIONS AND THERE ARE NO INTERFERENCE WITH THE THERMAL PROTECTOR. SPADE FEMALE 0.250 QUICK CONNECTORS AND MOUNTING BASE INCLUDED. Universal Thermal Protectors Universal OP-120 115/220V INTENDED AS UNIVERSAL REPLACEMENT FOR AIR CONDITIONING AND REFRIGERATION EQUIPMENT. FEMALE 0.250 SPADE QUICK CONNECTORS. BODY DIAMETER 3/4. Model Capacity Electrical Parameters HP BTU-H LRA Voltage OP-100 9000-10000 37 115/220 universal OP-120 12000 37 115/220 1 OP-150 15000 37 220 1 1/4 OP-0 000 34 115 1 1/2 OP-190 19000 34 220 1 3/4 OP-240 24000 35 220 2 Potential Relays TOTALLY SEALED. DUAL MALE 0.25 SPADE CONNECTORS. CLASS B ELECTRICAL INSULATION. SINGLE POLE CONTACTS. ELECTRICAL DIAGRAM INCLUDED. 90-067 Model Continuous Pick - Up Drop Out Voltage Volts Volts in Coil Min Max Max 90-063 170 139 153 55 90-064 395 260 275 120 90-065 332 168 2 90 90-066 395 215 225 120 90-067 420 295 315 125 90-068 502 325 345 135 90-069 336 0 195 105 90-070 253 285 305 77 8
TDM-08 STARTING TIME DELAY Time Delays ADJUSTABLE DELAY FROM 2 sec to 600 sec (10 min). DELAYS STARTING TIME AFTER THE LOAD IS ENERGIZED. 1.5 AMP, 15 AMP MAX, SPST, N.O. 2 X 2 COMPACT BOX. UNIVERSAL VOLTAGE FROM -288 VAC/VDC. 0.25 SPADE MALE CONNECTOR. TDM-08 TDB-08 SEQUENCE TIME DELAY ADJUSTABLE DELAY FROM 1 SEC-300 SEC (5 MIN) DELAYS COMPRESSOR STARTING TIME WHEN AN INTERRUPTION OCCURS AVOIDING PROBLEMS ASSOCIATED TO SHORT AND REPETITIVE CYCLES. 1.5 AMP, 15 AMP MAX, SPST, N.O. 2 X 2 COMPACT BOX. UNIVERSAL VOLTAGE FROM -288 VAC/VDC. 0.25 SPADE MALE CONNECTOR. TDB-08 Transformers COIL PROTECTOR ENSURES LONG LASTING LIFE. EASY INSTALLATION BECAUSE OF COMPACT SIZE. GALVANIZED STEEL FOOT MOUNTING BASE. ELECTRICAL CONECTION DIAGRAM ENCLOSED IN ATTACHED LABEL ON EACH UNIT. FRECUENCY 50/60HZ. T4OVA Model Capacity Input Output VA VAC VAC T40VA 40 120/208/240 24 T50VA 50 120/208/240 24 T75VA 75 120/208/240 24 T75VA-480 75 120/208/240/480 24 T75VA 9
Definite Purpose Contactors ARTICCO S CONTACTORS COMBINE A HEAVY DUTY CONSTRUCTION IN A COMPACT SIZE WHICH MAKES THEM IDEAL FOR REPLACEMENT WITHIN EXISTING AIR CONDITIONING OR REFRIGERATION EQUIPMENT. WE ARE PROVIDING COVERS AS A STANDARD FEATURE TO ALL OF OUR CONTACTORS. 2 poles 3 poles Available models & specifications 10 ADDITIONAL MODELS >>
CONTINUED 11
HEAVY DUTY FAN RELAYS ARTICCO S HEAVY DUTY FAN RELAYS COME EQUIPPED WITH A MULTIPOSITIONAL MOUNTING BRACKET AND ARE CAPABLE OF HANDLING HEAVIER LOADS THAN TRADITIONAL FAN RELAYS WITHIN A VERY COMPACT BODY SIZE. INDIVIDUALLY PACKED. 90-360 FEATURES TOTALLY ENCLOSED FOR DUST PROOF OPERATION. TERMINALS.250 MALE QUICK CONNECTORS. FREQUENCY 50/60 HZ. MECHANICAL LIFE 1,000,000 OPERATIONS. ELECTRICAL LIFE 250,000 OPERATIONS ON RESISTIVE LOADS AND 100,000 ON INDUCTIVE LOADS. 90-370 90-380 Model 90-360 90-370 90-380 Contacts Voltage VAC 120 240 277 120 240 277 120 240 277 Amp FLA LRA Voltage 12 8 7 12 8 7 12 8 7 60 48 42 60 48 42 60 48 42 Control Style Coil Voltage VAC SPST-NO 24 SPDT 24 SPNO-SPNC 24 12
GENERAL PURPOSE RELAYS ARTICCO S SWITCHING RELAYS HAVE MANY APPLICATIONS IN AIR CONDITIONING, REFRIGERATION AND HEATING EQUIPMENT. OUR RELAYS HAVE POWER DUTY CONTACTS AND COME AVAILABLE IN 24, 120, AND 208/240 COIL VOLTAGE FEATURES MULTI-POSITIONAL GALVANIZED STEEL MOUNTNG BRACKET. TERMINAL.250 MALE QUICK CONNECTORS. MECHANICAL LIFE 1,000,000 OPERATIONS. ELECTRICAL LIFE 250,000 OPERATIONS ON RESISTIVE LOADS; 100,000 OPERATIONS ON IN- DUCTIVE LOADS. 90-340 Visit our Showroom! 13
Run Capacitors ANODIZED ALUMINUM CAN FOR A RUST PROOF PRODUCT. INTERNAL SWITCH DISCONECT THE CAPACITOR WHEN EXCESIVE INSIDE PRESSURE OCCURS. TERMINALS WITH FOUR 0.25 MALE SPADE CONECTORS IN EACH ONE OF THEM. ROUND CAN TYPE FOR EASIER INSTALLATION. UL AND CE APPROVAL CERTIFICATIONS. SINGLE AND DUAL UNIT IN MOST COMMON CAPACITANCE VALUES. SINGLE CAPACITOR DUAL CAPACITOR DRY CAPACITOR SINGLE CAPACITOR 370V Model Capacity MFD 370V-4 MFD 4 370V-5 MFD 5 370V-10 MFD 10 370V-12.5 MFD 12.5 370V-15 MFD 15 370V-17.5 MFD 17.5 370V-20 MFD 20 370V-25 MFD 25 370V-30 MFD 30 370V-35 MFD 35 370V-40 MFD 40 370V-45 MFD 45 370V-50 MFD 50 370V-55 MFD 55 370V-60 MFD 60 370V-70 MFD 70 370V-80 MFD 80 DUAL CAPACITOR 370V Model Capacity MFD 370V-25+5 MFD 25+5 370V-30+5 MFD 30+5 370V-35+5 MFD 35+5 370V-40+5 MFD 40+5 370V-45+5 MFD 45+5 370V-50+5 MFD 50+5 370V-55+5 MFD 55+5 370V-60+5 MFD 60+5 SINGLE CAPACITOR 440V Model Capacity MFD 440V-25 MFD 25 440V-30 MFD 30 440V-35 MFD 35 440V-40 MFD 40 440V-45 MFD 45 440V-50 MFD 50 440V-55 MFD 55 440V-60 MFD 60 440V-70 MFD 70 440V-80 MFD 80 DRY CAPACITOR 450V Model Capacity MFD 450-1 1 450-1.5 1.5 450-2 2 450-2.5 2.5 450-3 3 450-3.5 3.5 450-4 4 450-4.5 4.5 450-5 5 450-6 6 450-7.5 7.5 450-8 8 450-10 10 450-12.5 12.5 450-15 15 MOTOR START CAPACITOR ARTICCO S MOTOR START CAPACITOR IS A DRY ELECTROLYTIC DEVICE INTENDED TO PROVIDE THE NECESSARY TORQUE TO START AC MOTORS THAT REQUIRE A HIGHER STARTING TORQUE IN RELATION TO THEIR RUNNING TORQUE. START CAPACITORS ARE RATED BY MINIMUM AND MAXIMUM MICROFARAD GENERATED AT A SPECIFIC VOLTAGE. FEATURES: COMPACT SIZE MAKES THEM AN IDEAL REPLACEMENT UNIT. CAPACITORS ARE HERMETICALLY SEAL TO PREVENT DAMAGE FROM MOISTURE AND OIL. STRONG BACKELITE CASE. TERMINALS DUAL.250 MALE QUICK CONNECTORES. 110v, 220v, 330v 14
TH-57V COOLING ONLY THERMOSTAT The TH-57V is an attractive low voltage (24v) wall Thermostat. They come in a white color that blends well with any decoration. The manual control setting and dual temperature readings, c and f, makes them very simple to operate. These features combined with their economical pricing makes them ideal for new installation. Mercury Free New magnetic switch Switch action spdt. Electrical rating 24 to 30 vac System control function on / off and fan on /auto. Set point range from 50 f to 90 f, 10 c to 32 c. Dimensions 2¾ x 4½ x 1¼. Mounting hardware and instruction provided. THERMOSTAT GUARD Intended to protect the thermostat from unauthorized misuse. Capable to protect phase monitors in the same way. Clear plastic cover allows ample visual field making it ideal for small spaces. Customer decides mounting directly on the wall or using the included sub-base. Easy installation on existing thermostat without removing them. Mounting screws and two metallic keys provided. Model Length Width Height TH-P36 6 3/8 3 1/2 3 TH-P58 8 1/8 4 5/8 3 5/8 TH-P54 5 1/4 4 5/8 3 1/4 15
TH-004 Window and Wall Air Conditioner Thermostat TH-004 WIDE TEMPERATURE RANGE FROM 10 C/50 F UP TO 32 C/90 F. FRONT MOUNTING ACCESSORIES INCLUDED. PLASTIC COVER FOR TERMINALS PROTECTION IN REAR PART. 48 STRAIGHT CAPILLARY BULB. Model Temp Range Temp. Electrical Switch Bulb Bulb Max / Min Differential Parameters Type Length Type TH-004 32ºC / 10ºC 2.5ºC 25 FLA SPST 1.2 m Straight 90ºF / 50ºF 4ºF 95LRA 48 TH-008 WINDOW A/C THERMOSTAT WIDE TEMPERATURE RANGE FROM 10ºC/50ºF TO 32ºC/90ºF. FRONT MOUNTING BRACKET SHAFT HALF MOON 0.250" DIAMETER AND 0.500" LENGTH. " COIL TYPE CAPILLAR. TH-008 Model Temp. Range Temp. Electrical Switch Max / Min Differential Parameters Type TH-008 32ºC / 10ºC 2.5ºC 25 FLA SPST 90ºF / 50ºF 4ºF 95 LRA TH-84 WINDOW A/C THERMOSTAT WIDE TEMPERATURE RANGE FROM 15.5ºC/60ºF TO 31ºC/87.5ºF. FRONT MOUNTING BRACKET SHAFT HALF MOON 0.250" DIAMETER AND 1.500" LENGTH. 0.250" MALE SPADE QUICK CONNECTORS. " STRAIGTH TYPE CAPILLAR. TH-84 TH-36 Model Temp. Range Temp. Electrical Switch Max / Min Differential Parameters Type TH-84 31ºC / 15.5ºC 2.5ºC 25 FLA SPST 87.5ºF / 60ºF 4ºF 100 LRA Room Air Conditioning Thermostat with Cross Ambient Bulb WIDE TEMPERATURE RANGE FROM 10 C/50 F UP TO 32 C/90 F. FRONT MOUNTING BRACKETS INCLUDED. 15 CAPILLARY LENGTH WITH 3 LONG BULB OF 3/8 DIAMETER. SHAFT HALF MOON. 250 DIAMETER AND 1/2. 500 LONG. Model Temp Range Temp. Electrical Switch Max / Min Differential Parameters Type TH-36 32ºC / 10ºC 2.5ºC 20 FLA SPST 90ºF / 50ºF 4ºF 80LRA 16
Mini Pressure Controls PSL25-80 LOW PRESSURE MINI CONTROL LOW PRESSURE FIXED PRESOSTAT FOR USE IN CONTROL CIRCUIT. INTENDED TO OPEN CIRCUIT WHEN PRESSURE FALLS BEYOND LOWER LIMITS AND CLOSE IT WHEN IT RETURNS TO NORMAL VALUES. PSH350-250 HIGH PRESSURE MINI CONTROL FIXED HIGH PRESSURE MINICONTROL WITH SAME FUNCTIONING METHOD THAN THE ABOVE MODEL. OPENS THE CIRCUIT WHEN PRESSURE IS HIGHER THAN PERMISSIBLE LIMITS. CONTACTS WILL BE CLOSED AUTOMATICALLY WHEN PRESSURE LEVELS RETURN TO NORMAL VALUES. CONNECTION CABLES 12 LONG. COMPACT BODY WITH BRONZE DEPRESSOR INCORPORATED AND 1/4 SAE CONNECTOR. SPST SWITCH. EASY COLOR CODE IDENTIFICATION: BLACK BODY FOR HIGH PRESSURE AND GREEN FOR LOW PRESSURE. AIR CONDITIONING PSL25-80 / PSH350-250 Model Pressure Settings Refrigerant Application Disconnection Connection PSL25-80 Low 25 PSIG 80 PSIG R22 PSH350-250 High 350 PSIG 250 PSIG R22 PSL75-100 Low 75 PSIG 100 PSIG R410a PSH600-475 High 600 PSIG 475 PSIG R410a PSL40-80 Low 40 PSIG 80 PSIG R134a PSH550-450 High 550 PSIG 450 PSIG R410a 17
12100 UNIVERSAL Motor Run Capacitor Includes: (2) Jumper Wires to Combine Individual Values into Desired MFD Rating 2.5/5.0/5.0 MFD (12.5MFD) TOTALMENTE COMBINADO 370VAC O 440VAC, 50-60 HZ -40 O C A +70 O C POR EIA SPEC. #456 Motor Run Capacitor, 2.5-15 Microfarad Rating, 370-440VAC Voltage, 60/50 Hz, Round Shape, 1-3/4 In. Diameter, 2-5/16 In. Case Height, 1-3/4 In. Overall Width, Terminal Type 1/4 In. Male Quick-Connect, -40 Degrees to 70 Degrees C Temp. Range, Case Material Aluminum, For Use With (14) Different Size Motors, Standards UL Recognized (E133000), VB BALL VALVES ARTICCO OFFER A LINE OF BALL VALVES FOR REFRIGERANT USE IN AL HCFC AND HFC REFRIGERANTS AND ASSOCIATED OILS. OUR LINE OFFERS COMPLETE SEALING OF THE REFRIGERANT LINE ISOLATING THE REFRIGERANT IN LIQUID OR GAS PHASE IN SINGLE OR BIDIRECTIONAL FLOW, FOR SERVICE PURPOSES. FOR OD COPPER TUBE DIAMETERS GREATER THAN 1/2" THE VALVE COMES WITH A SHRADER ACCESS VALVE 1/4" SAE. Model Connection Dia. Inches Access Valve VB-38 3/8 ODF N/A VB-12 1/2 ODF N/A VB-58 5/8 ODF 1/4 SAE VB-34 3/4 ODF 1/4 SAE VB-78 7/8 ODF 1/4 SAE VB-1 1-1/8 ODF 1/4 SAE VB-138 1-3/8 ODF 1/4 SAE VB-158 1-5/8 ODF 1/4 SAE VB-2 2-1/8 ODF 1/4 SAE Visit our Showroom!
Shut Off Valves CONSTRUCTED IN BRONZE AND EQUIPPED WITH REINFORCED PLASTIC STEERING WHEEL FOR SECURE GRIP. VALVE DESIGN DOES NOT ALLOW MOISTURE TO ENTER THE DIAPHRAGM CHAMBER. FULL FLOW APERTURE PROVIDE MINIMAL RESTRICTION AND LESS PRESSURE LOSS. HEX NUTS INCLUDED FOR FLARE VALVES WITHOUT ADDITIONAL COST. VP-38S Model Connection Type VP-14 1/4 SAE Flare VP-38 3/8 SAE Flare VP-12 1/2 SAE Flare VP-58 5/8 SAE Flare VP-14S 1/4 ODF Solder VP-38S 3/8 ODF Solder VP-12S 1/2 ODF Solder VP-58S 5/8 ODF Solder VP-34S 3/4 ODF Solder VP-78S 7/8 ODF Solder VP-38 Moisture Indicators BODY MADE OF BRONZE. UNBREAKABLE AND LEAK PROOF FRONT GLASS. EASY READING OF MOISTURE CONTENT BASED IN COLOR CODED SCALE. HEX NUTS INCLUDED FOR FLARE SIGHT GLASSES WITHOUT ADDITIONAL COST. COOPER EXTENDER INCLUDED FOR SOLDER MODEL. Model Connection Type Inches SG-14F 1/4 SAE Flare SG-38F 3/8 SAE Flare SG-12F 1/2 SAE Flare SG-58F 5/8 SAE Flare SG-14S 1/4 ODF Solder SG-38S 3/8 ODF Solder SG-12S 1/2 ODF Solder SG-34S 3/4 ODF Solder SG-58S 5/8 ODF Solder SG-78S 7/8 ODF Solder SG-14F TO SG-78S 19
20