Fisher L3 Pneumatic Level Controller

Similar documents
L3 Pneumatic Level Controller

Fisher Pneumatic Controllers and Transmitters

Fisher 2506 and 2516 Receiver Controllers

Fisher 2100 Pneumatic and 2100E Electric Liquid Level Switches

Fisher 546 Electro Pneumatic Transducer

Fisher Level Instruments

Fisher 249 Cageless Displacer Sensors

Fisher 249VS Cageless Displacer Sensor

Fisher 377 Trip Valve

Fisher D4 Control Valve Assembly

Fisher VBL Volume Booster

Fisher 657 and 667 Diaphragm Actuators

Fisher 249 Caged Displacer Sensors

Fisher 480 Series Yokeless Piston Actuators

Fisher POSI-SEAL A31A Cryogenic High Performance Butterfly Valve

Fisher FIELDVUE DVC6000 Digital Valve Controller Dimensions

Fisher 3660 and 3661 Positioners

Design D and DA Control Valves

Fisher 3660 and 3661 Positioners

Baumann 24000S Stainless Steel Control Valve

Baumann Corrosion Resistant Control Valve

Fisher FIELDVUE DVC6200 Digital Valve Controller / Magnet Assembly Dimensions

Fisher eplug complete Rotary Control Valve and Actuator Package

Fisher 377 Trip Valve

Fisher V250 Rotary Control Valve

Fisher 2625, 2625SST, and 2625NS Volume Boosters

Fisher 8590 High-Performance Butterfly Valve

Fisher EZ-Overtravel (EZ-OVT) Valve Trim

Fisher 2052 Diaphragm Rotary Actuator

Fisher CCV-N Fuel Gas Control Valve

Fisherr 2052 Diaphragm Rotary Actuator

Fisher CAV4 Control Valve

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

Fisher L2e Electric Level Controller

CML Electric Actuator for Baumann Series

Fisher i2p 100 Electro Pneumatic Transducer

Fisher 1077 Manual Handwheel Rotary Actuator

Fisher A31D Double-Flange High-Performance Butterfly Valve

Fisher A31D Double-Flange High-Performance Butterfly Valve

Fisher SS-252B Continuous Catalytic Regeneration Valve

Errata Sheet. for The following Instruction Manuals

Fisher FB Control Valve

Fisher V500 Rotary Control Valve

Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter

Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Control Valves

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

Fisher CV500 Rotary Control Valve

Fisher VBL Volume Booster

Fisher A31A Cryogenic High Performance Butterfly Valve

Fisher EU and EW Valves NPS 12 through 24 x 20

Fisher 3024C Diaphragm Actuator

Fisher CL600 Control-Disk Valve

Fisher 8532 High-Performance Butterfly Valve

WARNING. Mounting Instructions D103998X012 June DVC6200/DVC2000 Digital Valve Controller Linear Actuator Side Mount

Type 310A-32A Pressure Reducing Regulator

Fisher V150S Slurry Vee-Ball Control Valve

Fisher 8532 High-Performance Butterfly Valve

Features. Product Bulletin 51.6:8590 August Valve D104017X012

Fisher 8510 and 8510B Eccentric Disc Control Valves (EMA)

Design V250 Rotary Control Valve

Fisher L2 Liquid Level Controller

Fisher Control-Disk Rotary Valve

Fisher Z500 Severe Service Ball Valves

Fisher 685 Piston Actuator

Fisherr easy -et Cryogenic Sliding -Stem Control Valves

Fisher RSS Lined Globe Valve

Errata Sheet. for The following Instruction Manuals

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

WARNING. Mounting Instructions D103778X012 June 2013

Fisher 2052 Diaphragm Rotary Actuator

Fisher 8580 Rotary Valve

Fisher 8580 Rotary Valve

Fisher SS-138B Continuous Catalytic Regeneration Valve

Fisher YD and YS Control Valves

Fisher WhisperFlo Aerodynamic Noise Attenuation Trim

Fisher V260 Ball Control Valve

WARNING. Mounting Instructions D103996X012 May DVC6200/DVC2000 Digital Valve Controller on Linear Actuator

Fisher Large ED/EWD and ET/EWT Valves NPS 12 through 30

Fisher CAV4 Control Valve

Fisher FIELDVUE DVC6200 Series Hazardous Area Approval Nameplates

Fisher CV500 Rotary Globe Control Valve

Fisher 480 Series Yokeless Piston Actuators

Fisher Large ED/EWD and ET/EWT Valves NPS 12 through 30

Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Valve Instructions

Fisher Control-Disk Valve NPS 14-24

Fisher Whisper Trim III Cages

Baumann Flexsleev Sanitary Control Valve

Fisherr 1051 and 1052 Diaphragm Rotary Actuators

Fisher SS-263 Volume Booster

Fisher 9500 Butterfly Control Valve

Fisher 3610J and 3620J Positioners and 3622 Electro-Pneumatic Converter

Fisher D and DA Control Valves

Fisher 461 Increased Outlet Angle Sweep-Flo Valve

Fisher D4 Control Valve Assembly

type 630r relief Valve

Fisher 685SE and 685SR Piston Actuators

Fisher CAV4 Control Valve

Fisher RSS Lined Globe Valve

Baumann Sanitary Angle Control Valve

DVG/AF Variable Geometry Desuperheater

Transcription:

L3 Controller Product Bulletin Fisher L3 Pneumatic Level Controller The Fisher L3 pneumatic level controller is designed to sense liquid level or interface level in a vessel, and produce a standard pneumatic output signal proportional to the process variable. NPS 3 OR 4 WAFER STYLE SENSOR The controller comes complete with a wafer style sensor which can be flange mounted to the top of a vessel or installed in a customer supplied cage or chamber as shown in figure 4. Features Installation Versatility With the integration of a wafer style liquid level sensor and transmitter into one product, the L3 enables users to install pneumatic level controllers to a variety of industry standard or custom process vessel connections. Installing the L3 in a customer supplied external cage gives process equipment designers freedom to select the best process vessel connection location and configuration to meet specific application requirements. W8679 14 INCH DISPLACER CUSTOMER SUPPLIED CAE OR CHAMBER Easy Adjustment Set point and proportional valve opening are made with simple dial knob controls. Simple, Durable Construction Few moving parts are used. Knife edged driver bearing in sensor and plated brass instrument case ball bearing for torque tube rotary shaft help provide low friction operation. Easy Reversibility Action is field reversible from direct to reverse or vice versa without additional parts. Reduced Maintenance Costs Spring out wire provides for in service cleaning of relay orifice (figure 1). Reduced Operating Costs Supply pressure conservation is enhanced because relay exhaust opens only when output pressure is being reduced. NACE Compliant The materials used in the L3 wafer style sensor (see table 1) meet the metallurgical requirements of NACE MR0175 2002. Environmental limits may apply. www.fisher.com

Product Bulletin L3 Controller Figure 1. Fisher L3 Controller Figure 2. Fisher L3 Wafer Style Sensor SPRIN OUT CLEANIN WIRE PROPORTIONAL BAND ADJUSTMENT TORQUE TUBE W1800-1 KNIFE EDE BEARIN DISPLACER ROD DISPLACER W0656-1 DIRECT-ACTIN CONTROLLER Principle of Operation The sensor consists of a wafer body, torque tube assembly and displacer (see figure 2) and is available in CL150, 300, and 600. The wafer body mounts between NPS 3 or 4 raised face flanges. The torque tube assembly consists of a hollow torque tube with a shaft welded inside it at one end and protruding from it at the other end. The unconnected end of the tube is sealed by a gasket and clamped rigidly to the torque tube arm, permitting the protruding end of the shaft to twist and therefore transmit rotary motion. This allows the interior of the torque tube to remain at atmospheric pressure, thus eliminating packing and the disadvantages of packing friction. This is a proven and reliable seal. A change in liquid level, interface level, or density/specific gravity buoys up the displacer by a force equal to the weight of the liquid displaced. Corresponding vertical movement of the displacer results in angular movement of the displacer rod around the knife edge. Since the torque tube assembly is a torsional spring which supports the displacer and determines the amount of movement of the displacer rod for a given displacement change, it will twist a specific amount for each increment of buoyancy change. The controller uses the pressure balanced relay with a yoked double diaphragm assembly. Supply pressure either passes through the fixed orifice or bleeds out the nozzle. Nozzle pressure registers on the large relay diaphragm, and output pressure on the small relay diaphragm. Refer to figure 3. As long as the process remains constant, the displacer will hold the torque tube shaft and attached flapper steady in relation to the nozzle. The nozzle flapper opening will permit pressure to bleed from the nozzle as fast as it enters through the fixed orifice of the relay, keeping the pressure loading on the large relay diaphragm at the amount necessary to balance the output pressure loading on the small relay diaphragm. A process variable change (such as a variation in downstream demand that affects liquid outflow and thus the level of the tank shown in figure 3) changes the buoyant force acting on the displacer and moves the flapper with respect to the nozzle. An increasing buoyant force with direct action, or decreasing buoyant force with reverse action, produces a nozzle flapper restriction that increases nozzle pressure on the large relay diaphragm. This opens the supply end of the relay valve and increases relay output pressure. But a decreasing buoyant force with direct action, or increasing buoyant force with reverse action, produces a nozzle flapper opening that bleeds off nozzle pressure on the large relay diaphragm and opens the exhaust end of the relay valve to let output pressure (and thus actuator loading pressure) bleed away. The relay diaphragm pressure differential equalizes and a new output pressure is maintained according to the change in displacer position. 2

L3 Controller Product Bulletin Figure 3. Fisher L3 Schematic OUTER BOURDON TUBE CHANNEL INNER BOURDON TUBE CHANNEL FLAPPER SET P0INT OR ZERO ADJUSTMENT TORQUE TUBE SHAFT NOZZLE FIXED ORIFICE LARE DIAPHRAM EXHAUST PROPORTIONAL VALVE EXHAUST END OF RELAY VALVE SUPPLY PRESSURE TO OTHER PNEUMATIC INSTRUMENT IF TRANSMITTER CONSTRUCTION OR APPLICATION SMALL DIAPHRAM SUPPLY END OF RELAY VALVE E06263 A Ordering Information When ordering, specify: Wafer Style Sensor Construction Size NPS 3 or 4 raised face flange wafer style sensor suitable for CL150 through 600 flange rating Material Steel or stainless steel Notes Right hand mounting is standard, and can be field configured to left hand mounting as required by installation. During shipment, displacers are detached from the sensors. Equalizing piping, stillwells, or other equipment may be required for installation. Emerson Process Management does not provide this equipment. Instruction manuals used with the L3 pneumatic displacer level controller are Fisher 2500 and 2503 Controllers and Transmitters (D200124X012) and Fisher 249W Cageless Wafer Style Level Sensor (D102803X012). Application Level or interface 3

Product Bulletin Cage Construction Figure 4. Fisher L3 Mounted on Vessel L3 Controller Note A cage is not supplied with the L3. For a factory built cage style construction, contact your Emerson Process Management sales office. CAE WITH SIDE CONNECTIONS TOP MOUNTED ON VESSEL Figure 5 provides guidelines for fabricating a cage. When fabricating a cage or chamber, maintain at least a minimum clearance of 10 mm (3/8 inch) between the diameter of the displacer and the inside diameter of the cage or displacer. Dirty or viscous fluids may require a larger clearance. Provide sufficient cage length below the displacer to ensure that the displacer does not hit the bottom of the cage. When installing the cage, it must be vertically plumb so that the displacer does not strike the side of the cage. See figure 6 for overall envelope dimensions for mounting an L3. 1 DISPLACER STILLWELL CAE WITH TOP AND BOTTOM CONNECTIONS Note: 1 Stillwell required around displacer if the fluid is in a state of continuous agitation. 4

L3 Controller Product Bulletin Figure 5. Typical Cage Constructions NPS 3 OR 4 CL150, 300, OR 600 FLANE 356 mm (14 INCH) CAE WITH UPPER AND LOWER SIDE VESSEL CONNECTIONS E06541 WAFER STYLE SENSOR SIZE NPS 3 mm 178 INCH 7.00 CAE WITH UPPER SIDE AND BOTTOM VESSEL CONNECTIONS E06542 NPS 4 216 8.50 CAE WITH TOP AND LOWER SIDE VESSEL CONNECTIONS E06540 CAE WITH TOP AND BOTTOM VESSEL CONNECTIONS E06545 Notes: 1. Vessel connections are either NPS 1 1/2 OR 2 CL150, 300 OR 600 flanges. (Vessel ends can be also screwed or socket welded connections). 2. Displacer length is 14 inches. 5

Product Bulletin L3 Controller Figure 6. Overall Envelope Dimensions for the Fisher L3 LEFT HAND MOUNT RIHT HAND MOUNT MATCHES NPS 3 RAISED FACE FLANE MATCHES NPS 3 RAISED FACE FLANE 98 (3.88) 127 (5.00) 127 (5.00) 98 (3.88) 417 (16.40) MATCHES NPS 4 RAISED FACE FLANE 417 (16.40) 157 (6.19) 157 (6.19) 203 (8.00) 203 (8.00) 328 (12.90) WAFER STYLE SENSOR SIZE mm D INCH mm INCH 318 (12.51) NPS 3 60 2.38 178 7.00 NPS 4 76 3.00 216 8.50 239 (9.41) 73 (2.87) 73 (2.87) 232 (9.12) 356 (14.00) 356 (14.00) E06028 A D D mm (INCH) 6

L3 Controller Product Bulletin Specifications Available Configurations Controller: 2500, proportional only Wafer Style Sensor: 249W Matches NPS 3 or 4 raised face flange, suitable for CL150 through 600 flange rating Displacer length: 356 mm (14 inches) Input Signal Level or Interface Level: From 0 to 100 percent of displacer length Allowable Specific ravity Liquid Level: 0.4 to 1.2 Interface Level: NPS 3 wafer: 0.17 differential NPS 4 wafer: 0.11 differential Output Signal 0.2 to 1.0 bar (3 to 15 psig) or 0.4 to 2.0 bar (6 to 30 psig) Output Action Direct (increasing fluid or interface level or specific gravity increases output pressure) or Reverse (increasing fluid or interface level or specific gravity decreases output pressure) Supply Pressure (1) Normal Operation: 0.2 to 1.0 bar (3 to 15 psig): 1.4 bar (20 psig) 0.4 to 2.0 bar (6 to 30 psig): 2.4 bar (35 psig) Maximum Recommended: 3 bar (45 psig) Steady State Air Consumption (2) 0.2 to 1.0 bar (3 to 15 psig): Minimum (3) : 0.11 normal m 3 /hr (4.2 scfh) Maximum (4) : 0.72 normal m 3 /hr (27 scfh) 0.4 to 20. bar (6 to 30 psig): Minimum (3) : 0.19 normal m 3 /hr (7 scfh) Maximum (4) : 1.1 normal m 3 /hr (42 scfh) -continued- Proportional Band Proportional band of 0 to 100 percent of displacer length or displacement force change (10 to 100 percent recommended). Set Point Continuously adjustable to position control point or differential gap of less than 100 percent anywhere within displacer length (fluid or interface level) Performance Hysteresis and Deadband: <1% of output span at 100% proportional band Repeatability: NPS 3 sensor: 0.3% of displacer length or displacement force change NPS 4 sensor: 0.2% or displacer length or displacement force change Typical Frequency Response: 4 Hz and 90 degree phase shift at 100 percent of proportional band, differential gap, or span with output piped to typical instrument bellows using 6.1 meters (20 feet) of 6.4 mm (1/4 inch) tubing Ambient Temperature Error: ±1.5 percent of output pressure change per 28 C (50 F) of temperature change at 100 percent of proportional band, differential gap, or span when using sensor with standard wall N05500 torque tube Standard Tubing Connections 1/4 NPT internal Sensor Working Pressures (1) CL600 maximum Standard Supply and Output Pressure auge Indications 0.2 to 1.0 bar (3 to 15 psig): 0 to 30 psig 0.4 to 2.0. bar (6 to 30 psig): 0 to 60 psig Construction Materials Controller: Die cast aluminum case Wafer Style Sensor: See table 1 Mounting Positions Mounts on top of vessel or on customer supplied cage (see figure 4) 7

Product Bulletin L3 Controller Specifications (continued) Operating Limits Allowable Process Temperatures (2) Maximum: 232 C (450 F). See figure 7. Operative Ambient Temperatures (2) -40 to 71 C (-40 to 160 F) NOTE: Specialized instrument terms are defined in ANSI/ISA Standard 51.1 - Process Instrument Terminology. 1. The pressure/temperature limits in this bulletin and any applicable standard or code limitation should not be exceeded. 2. Normal m 3 /hr=normal cubic meters per hour at 0 C and 1.01325 bar. Scfh=standard cubic foot per hour at 60 F and 14.7 psia. 3. At zero or maximum proportional band or span setting. 4. At setting in middle of proportional band or span range. Table 1. Wafer Style Sensor Construction Materials Part Material (2) Wafer body and torque tube arm Torque tube Displacer Trim (1) Bolting Torque tube arm gasket and torque tube end gasket Hazardous Area Classification NPS 3, WCC or CF8M (316 stainless steel, cast) NPS 4, LCC or CF8M N05500 nickel alloy NPS 3, S31600 (316 stainless steel) NPS 4, S30400 (304 stainless steel) S31600 NCF coated steel grade B7 studs or cap screws and grade 2H nuts raphite/stainless steel 1. Trim parts include displacer rod, driver bearing, displacer stem parts, and stem connection parts 2. NACE MR0175 2002 compliant. Meets the metallurgical requirements of NACE MR0175 2002. Environmental limits may apply. 2500 controllers comply with the requirements of ATEX roup II Category 2 as and Dust Figure 7. uidelines for Heat Insulator Usage AMBIENT TEMPERATURE ( C) 71-40 -30-20 -10 0 10 20 30 40 50 60 70 800 400 TOO 1 HEAT INSULATOR REQUIRED HOT 300 400 200 100 NO INSULATOR NECESSARY 0 0-100 1 TOO HEAT INSULATOR REQUIRED COLD -200-325 -240-40 -20 0 20 40 60 80 100 120 140 160 Note: 1 If required, a heat insulator can be ordered seperately. B1413 1A AMBIENT TEMPERATURE ( F) PROCESS TEMPERATURE ( C) Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher is a mark owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Process Management Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Chatham, Kent ME4 4QZ UK Dubai, United Arab Emirates Singapore 128461 Singapore www.fisher.com 8 2003, 2012 Fisher Controls International LLC. All rights reserved.