Operating instructions EWB 200

Similar documents
Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

Operating instructions Bedienungsanleitung Mode d emploi

Operating instructions Bedienungsanleitung Mode d'emploi. minipuls C200.

SOLO 400/800/1600/ 3200 B

User Manual Rittal PMC UPS 6kVA

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED

Operations and Service Manual. X30208 Load Bank

Cordless Rechargeable Saw Instructions for Use

C3 Operating Instructions

Operating Instructions. PowerMax. CORDLESS CAULKING GUN Modell: HPS-4C2-10.8V Li-Ion 380ml to 410ml (5:1)Coaxial Cartridges

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. System Universal LED dimming insert Standard

GARDENA. N FIN P E I DK S NL F GB D

LEAD ACID BATTERY CHARGER

SAM Series Power Inverter

STATIC DAYLIGHT PAR 575 VF

Generator Set. CP Range. Operating & Maintenance Instructions 0702

ECO Spot 2500 User Manual

ECO Spot 2500 User Manual

USER MANUAL FOR 2000 WATTS POWER INVERTER USER S MANUAL--Read before operating this equipment

Electronic Ballast EVG 2000-T

Car Battery Charger Instructions for Use

Bore Hole Pump Model Nos: CBB75 CBB100 Part Nos:

X100P Load Bank. Read all instructions before using the load bank. Contents

1RECHARGEABLE APPLIANCES

INSTRUCTION MANUAL FOR LINEAR COMPRESSORS

Pure Sine Wave Inverter USER MANUAL

General safety and installation information.

Turbo M Series onboard charger

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

1000-Watt Energy Center

100 Watt Power Inverter + USB INSTRUCTION MANUAL HT8710-AUOXY

XS400 Load Bank. Read all instructions before using the load bank. Contents

c-go 24V/6A 24V/8A 24V/12A

1 Safety instructions

DC-AC Power Inverter SAM Manual. Please read this manual before installing your inverter

gamma uv Aquarium Ultraviolet Sterilizers

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

5.5 FT PRE-LIT SERBIAN SPRUCE TREE

SP6. Automatic Battery Charger. Model

GSL Electronics Modified Sine Wave Power Inverters

Light Source User Guide

MP V 8A Electronic Smart Charger. Instruction and Information Manual

Make/Type/Size/Model Honda Generator EB 3500X & EB5000X Operators Manual Open Well Ventilated Area to Start & Shut Down Machine

LESTRONIC II BATTERY CHARGER MODEL 07210

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

Light Source User Guide

MODEL Nos: CVAC20SS CVAC25SS CVAC30SSR OPERATING & MAINTENANCE INSTRUCTIONS. Distributed by CLARKE International Ltd.

DC TO AC POWER INVERTER

Phoenix Inverter

Measurements are expressed in millimeters.

Operating instructions broncolor Mobil A2l

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

Operations and Service Manual. XE400D-SB Load Bank

Cordless two speed drill/driver K 10613

Smart 110 with built-in flashlight for 6 240Ah lead-acid batteries

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

Operating instructions

JUMP STARTER OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JSM350 PART NO: ORIGINAL INSTRUCTIONS LS1117-ISS 1

12 amp RMS Battery Charger

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

OPERATION & MAINTENANCE INSTRUCTIONS

Models: SP3, SPSS3 Automatic Battery Charger

User s Manual. Automatic Switch-Mode Battery Charger

ATTACH YOUR RECEIPT HERE ITEM # FT. PRE-LIT DOUGLAS FIR TREE. MODEL #DF-75C85 Español p. 8

Smart Charger SBC User s Manual

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

Battery Charger JCB-FCH12Li

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER


OPERATING INSTRUCTIONS. LEISTER Varimat V Hot Air Automatic Welding Machine

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS

Sinewave Inverters. SWING 150VA and 300VA. User s manual

Switching DC Power Supply

2/10/50 AMP 12 VOLT BATTERY CHARGER/ ENGINE STARTER

Operating instructions 1 4 Mode d emploi 5 8 Instrucciones de uso 9 13 Manual de instruções 15 18

Triple Output Power Supply

8-STAGE AUTOMATIC BATTERY CHARGER MCU CONTROLLED - HIGH FREQUENCY SWITCHMODE MODELS: KACHG1207, KACHG1212, KACHG1220, KACHG2410. Instruction Manual

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

Modified Sine Wave Inverter USER MANUAL

OPERATION & MAINTENANCE INSTRUCTIONS

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

Operating instructions minipuls C200

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

Wilo-Control SC-Fire Jockey

BATTERY CHARGER-STARTER

7.0 Aspen Pine SYLVANIA Power-Lit TM M5 Warm White LED Pre-Lighted Tree V

ORIGINAL INSTRUCTIONS

Battery Charger JCB-FCH20LI2

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

Instruction Manual. CORDLESS DRILL 18V Li-ion WITH IMPACT FUNCTION. Model SROM 1172

OPERATION & MAINTENANCE INSTRUCTIONS

Transcription:

Operating instructions EWB 200 www.bron-kobold.com 1

Operating instructions EWB 200 Before use Please read all the information contained in these operating instructions carefully. They contain important details on the use, safety and maintenance of the lighting equipment. Keep these operating instructions in a safe place and pass them on to further users if necessary. Observe the safety instructions. Contents General safety instructions 3 Attention: Read before starting up.. 4 1. Starting up. 5 2. Power regulation. 6 3. Installing or replacing the lamp...6 4. LED Display.. 6 5. Controls and displays....7 6. Technical data. 7 2

General safety instructions When using your lighting equipment, basic safety precautions should always be followed, including the following: 1. Read and understand all instructions before using. 2. Close supervision is necessary when any appliance is used near children. Do not leave appliance unattended while in use. Animals must be kept away from the appliance. 3. The lamp and the accessories mounted onto the lamp may heat up to high temperatures, so please handle with care. 4. Do not operate lamp with a damaged cable or if the lamp has been dropped or damaged - until it has been examined by a qualified serviceman. 5. Position the cable so that it will not be tripped over, pulled, or make contact with hot surfaces. 6. If an extension cable is necessary, a cable with a current rating at least equal to that of the appliance should be used. Cables rated for less amperage than the appliance may overheat. 7. To reduce the risk of electric shock, never open this unit: take it to a qualified serviceman when service or repair work is required. Incorrect reassembly can cause electric shock when the equipment is subsequently used. 8. The use of an accessory attachment not recommended by the manufacturer may cause a risk of fire, electric shock, or injury to persons. 9. Always unplug ballast unit and lamp before cleaning or servicing and when not in use. Never jerk cable to pull plug from socket. Grasp plug and pull to disconnect. 10. The ballast unit EWB 200 must only be used with kobold lamps. 3

Attention: Read before starting up - For safety reasons the appliances may only be operated with an earthed mains (AC-line) plug. When the appliance is switched on, the yellow LED must light up "earth ok". - The drip-proof units (IP 43) are designed for use indoors and out, but under influence of drip water they have to be operated in the horizontal position. They have to be protected against splash water and excessive exposure to dust. - The accessories mounted onto the lamp base may heat up to high temperatures. Handle with care. - To protect against effects of radiated heat, the lamp must not be pointed at flammable surfaces and/or surfaces sensitive to heat or any objects from less than 2 meters away. - In order to prolong the service life of the lamp, the heating process of approx. 1 minute should not be interrupted. - To prevent overheating, do not obstruct the free air flow through the ventilation slots during operation. - Let ballast unit and lamp base cool completely before storing. - Before replacing fuses or the lamp, disconnect the ballast unit from power supply. - The equipment is not suitable for use in explosion-hazard areas. - Do not operate the lamp without a safety glass or with a damaged safety glass. Lamps may burst; the safety glass will retain the hot fragments. - Like natural daylight, HMI/MSR light contains a certain proportion of UV radiation. The safety glass reduces the UV content to safe levels for normal operating distances. When used at close operating distance, limit the exposure time of unprotected skin. 4

1. Starting up EWB 200 is a flicker-free electronic ballast unit. The 90 V to 265 V automatic voltage selector allows the system to be used universally. The unit is suited to operate with lamp bases with a hot restrike (HR), which means that the lamp may be switched on again at any time while hot, making waiting time unnecessary. For safety reasons, the high ignition voltages required for this purpose must have a correct earth conductor, the function of which can be checked with the aid of the earth monitoring lamp earth ok. For this reason the unit must always be connected to the power supply with an earthed mains plug. The daylight source EWB 200 can be used outdoors owing to the drip protection incorporated, with protected or sealed openings, watertight connecting sockets and the robust design. Connect the lamp base to the ballast unit EWB 200 and this in turn to the earthed power supply. Switch on mains switch and check whether the earth monitoring lamp LED earth ok lights up yellow. If this is not the case, the ballast unit must be immediately disconnected from the mains supply, for safety reasons, and the earth conductor checked before continuing. When the red display light supply ok is lit continuously, the ballast unit is operational. When supply ok is blinking, switching on is not possible because a problem has been discerned (see chapter LED display). By pressing the lamp button, the ballast unit is started up. The green LED (operating lamp) lights up. The ballast unit is equipped with an automatic heat-up device, so that the operating temperature is reached after only 1 minute. In this period the unit should only be switched off if absolutely necessary in order to prolong the service life of the lamp. The optimal colour temperature is reached after approx. 3 minutes of operation. If the HMI/MSR lamp cannot be triggered, the ballast unit stops the trigger process after about 1.5 s. A new attempt to trigger can be initiated by operating the lamp button again. After 10 attempts the unit will block the trigger circuit for about 30 seconds. After that further attempts are possible. Ensure that the ventilation slots are unobstructed during operation. 5

2. Power regulation The required light output can be set (100 % - 60 % adjustment range) with the power regulator. It should be noted that the colour temperature can change with the power output depending on the type of lamp used. During heat-up the power is automatically set to full until the operating temperature is achieved. The blocking time of the dimmer depends on the lamp temperature when switching on and can vary between 5 s and 40 s. 3. Installing or replacing the lamp Never replace a lamp without first disconnecting the lamp base from the ballast unit. 4. LED Display - Yellow LED has not lit up: Attention! Danger! The protecting earth of the ballast unit is not connected correctly. Ballast unit and lamp bases of safety class I must have a good protecting earth, all the more when it is used in a wet surrounding area. - Green LED is lit continuously: lamp is operating - Green LED is flashing: The thermo protection is activated reducing the power continuously down to 60 %. The power reduction to this limit enables the user to recognize the situation and delays the final shut-down. - Red LED is lit continuously: normal operating mode, all functions in working order. - Red LED is flashing: the unit has stopped operating for one of the following reasons: 1. The mains voltage has dropped below 85 V. 2. The overload protection has stopped the trigger circuit after approx. 10 unsuccessful attempts to trigger. After 30 seconds further attempts are possible. 3. Overheating of the ballast unit. 4. Short circuit in the lamp. 5. Technical fault. If this LED is flashing, the lamp will be switched off automatically. For safety reasons, it does not switch on again automatically after the technical fault is remedied (e.g. after cooling). The lamp must be switched on again manually. 6

5. Controls and displays EWB 200 1. Mains switch 2. Power regulator 3. Operating lamp LED (green) of the lamp base 4. Earth monitoring lamp LED (red) 5. Earth monitoring lamp LED (yellow) 6. Lamp socket 7. Mains cable socket 8. Fuse 2 9. Fuse 1 10. Grip 7

6. Technical data Nominal capacity 200 W Output 235 VA Mains voltage 90 V 265 V AC Mains frequency 45 Hz 400 Hz Cut-off at < 85 V Ignition possible from 90 V Power factor 99 % with 110 V, 95 % with 230 V Efficiency 89 % Ambient temperature -5 to 45 C Operation possible up to 45 to 60 C autom. power reduction to 60 % Storage temperature -20 to 80 C Cooling system Convection Lamp frequency 400 Hz Power variation 100 % to 60 % Stabilization power stabilizer with automatic heat-up device achieving lamp operating temperature in 1 minute Flicker < 5 % Dimensions 235 x 160 x 85 mm Weight 1.7kg Monitoring low mains voltage ignition overload protection overheating in the ballast unit lamp shorted technical fault LED display green: operating indicator of the lamp red : warning or operating indicator yellow: earth connected Degree of protection IP 43 Safety class I, with strengthened insulation for additional protection Standards EN60922 EN60529 EN61000-3-2/A14 grade C EN55011 grade B In accordance with 72/23/CEE, 89/336/CEE Lamp types Osram HMI 200 W/SE Philips MSR 200 HR Sylvania BA 200 SE HR Fuse 3.15 AT (2 pieces) 8

7. Operation of kobold equipment with motorgenerators Kobold equipment is basically suitable for operation with motor-generators provided that the supply voltage remains within the tolerance limits of 200-264V or 95-135V respectively under all load conditions (including capacitive load). Experience shows that this usually requires electronically stabilized motor-generators. 9

Printed in Switzerland 11.03 Bron Elektronik AG CH-4123 Allschwil Schweiz (Switzerland) 10