G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

Similar documents
G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Inductive Proximity Sensor

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

Model Number Structure

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

Ordering Information. Text PCB Power Relay G5LE

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Model Number Structure

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

Hinged Safety Door Switch

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Product discontinuation. Notices. Discontinuation Notice of Safety Relay and Socket. G7S series, P7S series. Wire connection

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

Inductive Proximity Sensor

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Power Contactor with Mirror Contacts

Safety-door Switch. Ordering Information

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0

Subminiature Basic Switch

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

General Purpose Relay

Manual Reset Limit Switch

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Switching Power Supply

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Type Terminal Coil Contact form Model

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Ordering Information. Text Surface-Mounting Signal Relay G6K

Model Number Structure

Model Number Structure

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM

Switching Power Supply

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

General Purpose Relay

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm

Ordering Information. Application Example. New General-purpose Incremental-type. Rotary Encoder. Accessories (Order Separately)

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Cylindrical Proximity Sensor

A22NK. Key-type Selector Switches

The full feature relay includes the combination for rotary button or plain button or light or indicator flag.

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Mechanical Key Switch

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

24-hour/Weekly Time Switch H2F

Small Limit Switch D4V

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

D4DL. Guard Lock Safety-door Switch. Model Number Structure

AC 250V AC 250V AC 250V AC 250V DC 110V DC 110V DC 110V DC 110V Max. Allowable Current 15A 10A 10A 10A

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

General Purpose Relay

Type List. Standard Type. High Power Type

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Safety Limit Switch

Lighted Pushbutton Switch

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

Tactile Switch (Hinged Type)

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

E bracket (see note 1) SPST-NO G7L-1A-TJ-CB G7L-1A-BJ-CB DPST-NO G7L-2A-T-CB G7L-2A-B-CB

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Model Number Structure

D4BS CSM_D4BS_DS_E_8_4

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

Features. Emergency Stop Switch A165E. Separate Construction with Smallest Class of Depth in the World. Safety Lock Prevents Misuse

Proximity Sensor. Shield Size Sensing distance Output configuration Models Shielded M12 3 mm NO E2EQ-X3D1 E2EQ-X7D1 M30 10 mm E2EQ-X10D1

Transcription:

Safety Relay Safety Relay conforming to EN standard Conforms to pren50205. A minimum of 0.5 mm between contacts even when one contact is welded. (pren50205 Class A) Forcibly guided contacts. The contributes to the protection of machinery when used as part of an interlocking circuit. Most suitable for safety circuits in press machinery, machine tools, and other production machinery. CE mark (EC Low-voltage Directive 73/23/EEC) Track-mounting and Back-mounting Sockets are available. Be sure to refer to the Precautions on page 7. Ordering Information Model Number Legend -jajb 1 2 1. NO Contact Poles 4: 4PST-NO 3: 3PST-NO Safety Relays 2. NC Contact Poles 2: DPST-NC 3: 3PST-NC Type Poles Contact form Rated voltage (V) Model Standard 6 poles 4PST-NO, DPST-NC 24 VDC -4A2B 3PST-NO, 3PST-NC -3A3B Accessories Safety Relay Sockets Type Model Track-mounting Common for track mounting P7S-14F and screw mounting Back-mounting Solder terminals P7S-14A PCB terminals P7S-14P Socket Mounting Plate Applicable Socket Quantity Model P7S-14A 10 P7S-A10 Relay Removal Tool Applicable Sockets P7S-14F P7S-14A P7S-14P P7S-B Model 1

Specifications Ratings Operation Coil Rated voltage Rated current Coil resistance Must operate voltage Must release voltage Max. voltage Power consumption 24 VDC 30 ma 800 τ 80% max. (V) 10% min. (V) 110% (V) Approx. 0.8 W 1. The rated current and coil resistance are measured at a coil temperature of 23 C with tolerances of 15%. 2. Performance characteristics are based on a coil temperature of 23 C 3. The maximum voltage is based on an ambient operating temperature of 23 C maximum. Switching Section (Contact Ratings) Load Resistive load (cos =1) Inductive load (cos = 0.4, L/R = 7 ms) Rated load 240VAC:3A,24VDC:3A 240VAC:3A,24VDC:1A Rated carry current Maximum switching voltage Maximum switching current Maximum switching capacity (reference value) Min. permissible load (See note.) Contact material 6A 250 VAC, 24 VDC 6A 1,440 VA, 144 W 5 VDC, 10 ma Ag + Au The above values are based on an operating frequency of 60 operations/min. Characteristics Contact resistance (See note 2.) Operatetime(Seenote3.) Release time (See note 3.) Maximum operating frequency Insulation resistance Dielectric strength Mechanical Rated load 100 mτ max. 50 ms max. 50 ms max. 18,000 operations/hr 1,800 operations/hr 100 Mτ min. (at 500 VDC) Vibration Destruction 10 to 55 Hz, 1.5-mm double amplitude Malfunction 2,500 VAC, 50/60 Hz for 1 min (1,500 VAC between contacts of same polarity) 10 to 55 Hz, 0.75-mm double amplitude Shock Destruction 1,000 m/s 2 (approx. 100G) Malfunction 100 m/s 2 (approx. 10G) Life expectancy Mechanical 10,000,000 operations min. (at approx. 18,000 operations/hr) Electrical Ambient operating temperature Ambient operating humidity Ambient storage temperature Ambient storage humidity Weight 100,000 operations min. (at the rated load and approx. 1,800 operations/hr) - 10 C to 70 C (no icing) 35% to 85% RH - 25 C to70 C (no icing) 35% to 85% RH Approx. 65 g 1. The values given above are initial values. 2. Measurement conditions: 5 VDC, 10 ma, voltage drops. Characteristics of Safety Relay Socket 3. Measurement conditions: Rated voltage operation Ambient operating temperature: 23 C Does not include bounce time. Model Continuous current Dielectric strength Insulation resistance P7S-14j 6A 2000 VAC for 1 min. between terminals 1000 Mτ min. (see note) Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC. 2

Approved Standards VDE0435 (Electrical Relays); Approved by VDE IEC255 (Electrical Relays); Approved by VDE pren50205 (Electrical Relays); Approved by VDE UL508 (Industrial Control Device); Pending CSA22.2 No.14 (Industrial Control Device); Pending Engineering Data Life Expectancy (240 VAC; cos =0.4, cos =1) Life expectancy (x10 4 operations) 100 10 G9S 1 Life Expectancy (AC15, DC13 IEC947-5-1/Table 4) 6,050 operations min. (AC15, 240 VAC, 3 A, cos Ζ0.3) 6,050 operations min. (DC13, 24 VDC, 1 A, L/R 100 ms) VDE approved. 0 1 2 3 4 5 6 Switching current (A) I (Current) 3

Dimensions All units are in millimeters unless otherwise indicated. Safety Relays -4A2B -3A3B Terminal Installation/Internal Connection Diagram 62 max. 22.5 max. 37 max. 24 VDC 5min. 24 VDC (Bottom View) -4A2B -3A3B Fourteen, 1.8 dia. Cross-section of Mounting Holes Safety Relay Sockets P7S-14F Track-mounting Socket 40 max. 7.5 4 31.3 7x4=28 Terminal Installation/Internal Connection Diagram (Top View) 47 max. 90.5 max. 40 max. Cross-section of Mounting Holes With Safety Relay Mounted 69 max. 47 max. 4

P7S-14A Back-mounting Socket (Solder Terminals) 23 max. 61.5 max. Terminal Installation/Internal Connection Diagram (Bottom View) -4A2B 33 max. Cross-section of Mounting Holes With Safety Relay Mounted -3A3B 39 max. P7S-14P Back-mounting Socket (PCB Terminals) 23 max. 61.5 max. Two, 6.5 dia x 7.9 deep Terminal Installation/Internal Connection Diagram (Bottom View) -4A2B Cross-section of Mounting Holes 29 max. With Safety Relay Mounted 23 max. -3A3B Two, 3.6 dia. 28 max. Fourteen, 1.8 dia. 5

Socket Mounting Plate P7S-A10 (Special Mounting Plate for P7S-14A) 261 max. Four, C0.5 81 max. Relay Removal Tool P7S-B 6

Precautions Forcibly Guided Contacts When NO contacts are welded, the coil will be non-energized so all NC contacts will maintain a distance between the contacts of 0.5 mm minimum. Likewise if NC contacts are welded, the coil will be energized so all contacts will maintain a distance between each other of 0.5 mm minimum. Application! Caution Do not touch the terminal area of the Relays or the socket terminal area (charged area) while power is ON. Electric shock will result. Safety Relays A Safety Relay is a Relay with which a safety circuit can be configured. For common precautions when using and handling Relays, refer to OMRON s Relay Catalog. Contacts The coil terminals have polarity (positive and negative).operation is not possible if these are connected in reverse. 7

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J107-E1-2 OMRON Corporation Control Components Division H.Q. 28th Fl., Crystal Tower Bldg. 1-2-27, Shiromi, Chuo-ku, Osaka 540 Japan Phone: 06-949-6115 Fax: 06-949-6134 In the interest of product improvement, specifications are subject to change without notice. Printed in Japan 0897-1M (1296) a 8