Photovoltaic fuses gpv curve from 1 to 600 A, up to 1500 VDC

Similar documents
Rated Current (Amps) Power Loss (Watts) 0.8 x I n 1 x I n PVM PVM PVM

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

fuse-links & fuse holders PHOTOVOLTAIC

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

XL Style Photovoltaic Fuse Links for Solar Panel Applications 50 to 630A, 1000 & 1500Vdc PV Series

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC

for NH industrial and high-speed (ur) fuses from 160 to 2500 A

CHS Controls. Photovoltaic system protection.

E 90 range of fuse disconnectors and fuseholders Uncompromising performance

HelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC

INDUSTRIAL CYLINDRICAL FUSE LINKS

Solar circuit protection application guide. Complete and reliable solar circuit protection

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

Bussmann series photovoltaic application guide. Complete and reliable solar fusible circuit protection

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS

Bussmann series NH photovoltaic fuse links

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Bussmann PV Application guide. Complete and reliable solar circuit protection

XL Photovoltaic fuse links

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

Complete and reliable solar circuit protection

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

NH photovoltaic fuse links

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

Fuse holders and fuses

What you need to know. Â Conformity to standards

Photovoltaic System Overcurrent Protection

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Panel-mounting components

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on right side

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Protistor size 120 gr 750VDC (IEC)

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

An innovative technology

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

RAPIDPLUS. high speed fuse links for semiconductors

PANEL-MOUNTING COMPONENTS FUSE HOLDERS. Quality

HELIOPROTECTION PROGRAM SOLUTIONS FOR PHOTOVOLTAIC (ISSUE 12.1)

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

Ultra Rapid Fuses. For Semiconductor Protection

RAPIDPLUS. high speed fuse links for semiconductors

GREEN PROTECT PROTECTION OF PV SYSTEMS. Green protect - DC POWER NEEDS CONTROL

Solar Photovoltaic Power. Overarching Objectives. How many questions? 9/16/2012. From plan review to Final Inspection

Photovoltaic System Overcurrent Protection

DX³ RCCBs - ID 4P up to 100 A

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

CYLINDRICAL FUSES. 8x32. 10x38. 14x51. In REFERENCE U BREAKING CAPACITY REFERENCE U BREAKING CAPACITY PACKING (A) IEC /95/EC

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

up to 63 A (1 module per pole)

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Switching, control and protection solutions for solar applications

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DC Fuse-Links 10 x 38

Helio Protection. Solar solutions designed by Ferraz Shawmut. Power generation & distribution.

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings

DX³ 4-pole RCBO 6000 A/10 ka

PANEL PANEL MOUNTING COMPONENTS

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

PV Fuse-Links Superior Protection of Valuable Photovoltaic Modules

photovoltaic NEW Safe product solutions conforming to standards for Industrial Electrical Power Distribution Systems with extended product range

DX³ RCBO 6000A Phase + Neutral, neutral on left

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

TX³ RCCBs 2P up to 100 A

DX³ RCBO 6000 A Phase + Neutral, neutral right side

Power protection solutions

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

DX³ RCBO 6000A Phase + Neutral, neutral on right

Solar PV Standard Plan Simplified Microinverter and ACM Systems for Oneand Two-Family Dwellings

Steca Elektronik INVERTER / CHARGER WITH MPPT: SOLARIX PLI

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

SIRCO M and MV Universal load break switches from 16 to 160 A

Utilisation category gl/gg 500VAC with combi indicator

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A

RX 3 M.C.B A up to 63 A

the National PhotoVoltaic protection note 5 I rated Introduction points of interest When to Fuse, When Not to Fuse

CYLINDRICAL FUSES CYLINDRICAL FUSES

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

RX 3 M.C.B A up to 63 A

ABB central inverters PVS to 2091 kva

MCBs and RCDs LR TM 6000

ABB central inverters PVS to 2000 kva

Transcription:

from to 600 A, up to 500 VDC Fuse protection The solution for > Photovoltaic protection fusib_03_a cat fusib_026_a cat Function fusib_030_a x_cat fusibpv_06_a cat SOCOMEC's gpv fuses protect photovoltaic installations against overcurrents caused by reverse currents that can occur in PV applications. fusibpv_03_a cat fusibpv_032_a cat Strong points > High breaking capacity up to 500 VDC > Product dedicated to photovoltaic installations > High reliability > Improved safety Large range Advantages High breaking capacity Up to 50 ka to 00 VDC, 30 ka to 500 VDC. Product dedicated to photovoltaic installations Operating ranges adapted to low overcurrents specific to photovoltaic systems. High reliability Absolute protection over time guaranteed by the simplicity of manufacture and function (Joule effect). No downgrading of fuse characteristics over time. Improved safety The energy released whilst eliminating the fault (fuse blowing) is contained within the cartridge (no degassing). > Associated range of switches and fuse bases, dedicated combs and connection accessories Compliance with standards > IEC 602696 > IEC 60269 > IEC 602692 What you need to know Characteristics used I SC : short circuit current of the string. I SC MAX: short circuit current of the string related to maximum sunlight density. I RM : maximum admitted reverse current. I n : fuse rating or fuse rated current (at 25 C in a RM fuse base). N c : number of strings in parallel. U e : fuse maximum operating voltage. U OC MAX: maximum open circuit voltage in the lowest temperature conditions. When to protect A PV string requires an overcurrent protection when its own maximum admissible reverse current characteristic (Irm) is less than the current generated by the rest of the installation (current generated by the other "Nc" strings). How to protect Protection against overcurrents has to be applied to both polarities, regardless of wheather the DC installation is earthed or not. 368 General Catalogue 207208

from to 600 A, up to 500 VDC How to choose the right fuse protection Voltage U e > U OC MAX In the absence of complementary information use U OC MAX =.2 U OC Fuse rating determination Determination of the fuse rated current consists of choosing a protection capable of: Supporting without fusing the normal overload current during the periods of maximum sunlight density at the ambient temperature of the enclosure in which the fuse is installed, I n > I SC MAX In the absence of complementary information use ISC MAX =.4 I SC Melting and reliably clearing the fault before the PV modules are damaged by the reverse current. I n < I RM + + + PV panels + + + Fuse protection (x38 and RM PV) Level Combiner box Fuse protection (x38 and RM PV) Level Combiner box fusib_79_b gb_cat PV Disconnect switch Surge arrester + PV Disconnect switch Surge arrester + Fuse protection (Busbar bolted or NH and bases) Level 2 ReCombiner box Surge arrester + PV Disconnect switch Inverter General Catalogue 207208 369

from to 600 A, up to 500 VDC References Rated voltage 00 VDC Dissipated power Rating (A) Fuse size W @ In W @ 0.8 In gpv cylindrical fuses Breaking capacity Reference x 38 0.76 0.43 30 ka 60PV 000 2 x 38.54 0.84 30 ka 60PV 0002 3 x 38.35 0.74 30 ka 60PV 0003 4 x 38.84.08 30 ka 60PV 0004 6 x 38 2.50.40 30 ka 60PV 0006 8 x 38 2.57.47 30 ka 60PV 0008 x 38 2.58.5 30 ka 60PV 00 2 x 38 2.6.42 30 ka 60PV 002 5 x 38 2.44.08 30 ka 60PV 005 6 x 38 2.70.56 30 ka 60PV 006 20 x 38 2.99.75 30 ka 60PV 0020 25 4 x 5 5. 2.7 ka 60PV 0C25 32 4 x 5 6.2 3.3 ka 60PV 0C32 gpv knife edge fuse 32 NH 8.5 4.3 50 ka 60PV 0032 40 NH 9 4.6 50 ka 60PV 0040 50 NH.5 5.4 50 ka 60PV 0050 63 NH 2 6. 50 ka 60PV 0063 80 NH 5.5 7.9 50 ka 60PV 0080 0 NH 6.5 8.4 50 ka 60PV 00 25 NH 7.5 8.9 50 ka 60PV 025 60 NH 24 2.2 50 ka 60PV 060 200 NH 25 3 50 ka 60PV 200 250 NH2 35 23 50 ka 60PV 250 35 NH3 44 27 50 ka 60PV 35 400 NH3 50 30 50 ka 60PV 400 500 3 L 85 50 50 ka 60PV 0500 600 3 L 8 92 50 ka 60PV 0600 Rated voltage 500 VDC Dissipated power Rating (A) Fuse size W @ In W @ 0.7 In W @ 0.8 In Breaking capacity Reference gpv cylindrical fuses 2 x85 3.42.28 6PV 0002 4 x85 2.9.6 6PV 0004 6 x85 2.65. 6PV 0006 8 x85 2.79.6 6PV 0008 x85 4.38.8 6PV 00 2 x85 4.43.83 6PV 002 6 x85 4.3.75 6PV 006 20 () x85 5.4 2.3 6PV 0020 () 25 () x85 5.48 2.28 6PV 0025 () gpv knife edge fuse 200 XL 6 3 30 6PV 0200 400 3L 9 49 30 6PV 0400 () Rated voltage 200 VDC. Accessories Size NH Size NH2 Size NH3 Size XL Size 3L Accessories Reference Reference Reference Reference Reference Fuse blown auxiliary contact 56PV 990 56PV 990 56PV 990 56PV 990 56PV 990 Fuse base recommended 65PV 65PV 02 65PV 03 65PV 3 370 General Catalogue 207208

from to 600 A, up to 500 VDC Adjustment due to ambient temperature I nf = I scgen /K t Inf gpv fuse rated current. Iscgen shortcircuit current of PV generator in STC conditions. Kt derating factor. Max. ambient temperature ( C) Kt: derating factor 20 40 0.92 45 0.90 50 0.87 55 0.85 60 0.82 65 0.79 70 0.76 Standard dimensions (mm) as per IEC 602692 gpv cylindrical fuses Fuse size Striker A B C x 38 Without.3 38.5 fusib_67_a x_cat A C B 4 x 5 Without 4.3 5.5. x 85 Without.3 85.5 gpv knife edge fuse A B C D T F G Fuse size Striker max max max max fusibpv_00_a x_cat D A B C E G F NH Without 37 20 6 68 40 53 40 NH2 Without 52 25 6 75 60 6 48 NH3 Without 52 32 6 75 70 75 60 XL Without 90 20 6 28 5 5 40 3L Without 205 32 6 23 74 74 60 Time/current operation characteristics Rated voltage 00 VDC gpv cylindrical fuses x38 gpv cylindrical fuses 4x5 000 A 2A 3A 4A 6A 8A A 2A 5/6A 20A 000 25A 32A 00 00 0 0 x38 gpv 4x5 gpv 0. 0. fusibpv_002_b gb_cat 0.0 0.00 0 00 Available Current, DCTime Constant 3ms (Amps) fusibpv_003_c gb_cat 0.0 0.00 0 00 Available Current, DCTime Constant 3ms (Amps) General Catalogue 207208 37

from to 600 A, up to 500 VDC Time/current operation characteristics (continued) Rated voltage 00 VDC gpv NH knife edge fuses gpv NH2 knife edge fuses 000 32A 40A 50A 63A 80A 0A 25A 60A 200A 000 250A 00 00 0 0 NH gpv NH2 gpv 0. 0. fusibpv_004_d gb_cat 0.0 0.00 0 000 000 Available Current, DCTime Constant 3ms (Amps) fusibpv_033_a gb_cat 0.0 0.00 0 00 000 Available Current, DCTime Constant 3ms (Amps) gpv NH3 knife edge fuses gpv 3L knife edge fuses 000 35A 400A 000 500A 600A 00 00 0 0 2XL gpv 3L gpv 0. 0. fusibpv_005_d gb_cat 0.0 0.00 0 000 000 Available Current, DCTime Constant 3ms (Amps) fusibpv_006_d gb_cat 0.0 0.00 0 000 000 Available Current, DCTime Constant 3ms (Amps) 372 General Catalogue 207208

from to 600 A, up to 500 VDC Rated voltage 500 VDC gpv cylindrical fuses x85 gpv XL knife edge fuses 000 2A 4A 6A 8A A 2A 6A 20A 25A 000 200A 00 00 0 0 x85 gpv XL gpv 0. 0. fusibpv_027_b gb_cat 0.0 0.00 0 00 Available Current, DCTime Constant 3ms (Amps) fusibpv_028_b gb_cat 0.0 0.00 0 00 000 Available Current, DCTime Constant 3ms (Amps) gpv 3L knife edge fuses 000 400A 00 0 0. 3L gpv fusibpv_029_b gb_cat 0.0 0.00 0 00 000 Available Current, DCTime Constant 3ms (Amps) General Catalogue 207208 373