SERIES TAP-CHANGER

Similar documents
1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

Transformer bushings, type GOH. Technical guide

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

ABB Power T&D Company Inc. General Information: DT-100 DT-150 DV-100 DV-150. De-energized Switches TPL , July 1999, Page 1 of 4

Transformer bushings, type GSA-OA Technical guide

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

LV Bushing Oil to Air Dry Insulation PTAB-SLV832

Gas Insulated Switchgear

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

1ZSE en, Rev. 9. Transformer bushings, type GSA-OA Technical guide

BUSHINGS: GENERAL INFORMATION

Load Break Switch Type LBOR-II, Oil Immersed PTAT-LIR975 IZUA Technical Guide Nut Mount Weld Mount

Transformer bushings, type GOA 250. Installation and maintenance guide

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st New RIS transformer bushings The paper-free solution

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

Bushings for High Voltage AC Applications

DM Condenser bushings, kV DURESCA

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Energy sector DC LINK CAPACITORS AND SNUBBERS

PORCELAIN BUSHINGS ED Series

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

CATALOGUE TRACTION OUTDOOR DISCONNECTORS TYP QAD 3. 3 kv DC; 2500; 3000; 4000; 4500 A

A of 3. Edition : Date : Page : Document No. Amendments :

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

NXPLUS C Single busbar. Maintenance-free for lifetime

WESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO. GUARANTEED TECHNICAL PARTICULARS 1 of 2

Oil level gauges Series IL

Distribution transformers Efficiency over life-cycle

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

A of 14. Edition : Date : Page : Document No. Amendments :

Motor-drive mechanism, type BUL. Technical guide

Bushing Insulators according to DIN and UNEL Standards

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

DURESCA Busbar system. For indoor and outdoor applications, type DE / type DG DURESCA

Technical Specification for 33 KV 200 AMPs,H.G,Fuse set.

Metal Clad Switchgears

Low voltage bushings for pad-mounted distribution transformers Technical information guide

On-load tap-changer OILTAP V

Waterproof Series Waterproof

Throughout the years, various types of off circuit tap changers (OCTCs) have been developed in Hyundai Heavy Industries Co.

Protection components

CAST RESIN DISTRIBUTION TRANSFORMERS 2017 EDITION

TGK Prefabricated Substation Technical Data

High Voltage and Extra High Voltage Cables

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

Fluid characteristics impact performance capabilities in transformer application

BRUDA. Removable control gear plate. Computer aided design reflector. Single piece high-pressure diecast aluminium housing.

Overhead line switchgear

M-0. M-0... series control, monitoring and signalling devices. Ex e

THORNE & DERRICK UK TEL FAX TEL FAX

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

100 A externally operated one-, twoand three-phase tap-changer switch

Power IT Liquid Filled Transformers. IEC standard, small and medium, rated power 2000kVA, HV 36kV

Zinc Oxide Surge Arrester EXLIM R

Safety rope switch with reset for emergency stop

Zinc Oxide Surge Arrester PEXLIM Q

20 HUBER+SUHNER RADOX SOLAR

General catalogue Epoxy resin and silicon rubber insulators

Shanghai Huaming Power Equipment Co.,Ltd.

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

Maximum temp. rise in oil by 40 thermometer above design ambient (deg C) specified time Short circuit rating (Sec) for As per IS 2026

Energy Division. PCA Single Column Polymeric Surge Arrester

GAS INSULATED VOLTAGE TRANSFORMERS.

Technical Specification of GECOL. Packaged Transformers

017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA

INTERFACE E - 5/8" MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide

Micafil transformer oil-sf 6 bushings GARIP / RTKG kv. Power and productivity for a better world TM ABB

EMC- Components. Feed-Through Capacitors Feed-Through Filters in Solderless MKP Technology. Data Book Supplement

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

NH DIN Dual Indication Fuse Links

XMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O

EARTHING AND SHORT CIRCUIT LANCE DEVICE RAILWAYS

PowerIT Indoor Voltage Transformer Fuses, WBP. Outdoor Voltage Transformer Fuses, BRT. Catalogue 1YMB en. Industrial IT.

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

a Nexans company Catalogue 2009

A 1.2 kv class externally removable secondary bushing

B kv Gas-insulated Substations

tests Partial discharge level from day 1 10 pc Insulation 24 kv : impulse tested at 125 kv Insulation 36 kv : impulse tested at 170 kv, 200 kv indeed.

OLIVER ONLINE VOLTAGE REGULATION

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

CAPACITORS FOR POWER ELECTRONICS

Product Specification

Epoxy Technology Embedded Poles

Water cooled high current cables

*(1(5$/7(&+1,&$/63(&,),&$7,2162) +9/9 ',675,%87,2175$16)250(56

Mounting and Operating Instructions EB 8392 EN. Series 3710 Type 3710 Reversing Amplifier

1ZSC ABH en, Rev. 1. Motor-drive mechanisms, types BUE and BUL2 Maintenance guide

a Nexans company Catalogue 2007

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Transcription:

SERIES 090 - TAP-CHANGER Main characteristics This is an off-circuit tap changer. It means DO NOT OPERATE WHILE THE TRANSFORMER IS ENERGISED. Main characteristics of this tap-changer series are: dimensional compactness only 4 components to assemble for customers only one rotative movement self centring moving contacts They can be used either in mineral or synthetic oil, in silicon liquid or in eco-fluid. In the catalogue are performed the standard appliances and devices. On request is possible to satisfy special requirements as: - multi-stage tap changers - mirror like assembling - insulated intermediate clamp for different dimension of the shaft L - special executions Mechanical characteristics On the tap-changers type 090 fixed contacts are mounted in the fixed strips perpendicular to the support, while in the moving strips are installed moving contacts. The fixed strip is bolted to the bearing in which the moving strip slides, driven by a pinion. Metallic parts The metallic parts that mainly compose drive control of the tap-changer are normally made of stainless steel and brass. The brass parts exposed to external environment on request can be made of stainless steel (see different solutions on page 090-60-0). Polyamide parts Lower part of the bearing gear and control knob are normally made of polyamide. On request, control knob can be supplied made of aluminium and the eventual protective cover in Zama 15. Changing over The knob must be inserted only when the 2 milled centring parts have been aligned. One is positioned on the shaft and the other is positioned on the metallic section of the support. To change the position, after having released the locking-device up to its stroke-end, you only have to rotate the knob without pulling it up and continue the operation up to reach the wanted new position, than screw the locking-device. The knob can be padlocked in any position by utilizing the appropriate rectangular hole on the positioning-ring and inserting the shackle of the padlock (6 mm max.) in the corresponding hollow space of the knob. For more information please request the operation instruction manual to C.a.p.t. Oil tight Oil and silicon oil sealing is obtained by the use of O-ring gaskets. Fixed contacts Made of copper with following internal diameters: Ø = 2,1 mm for 10 A rating, Ø = 3,1 mm for 30 A rating, Ø = 5,1 mm for 60 A rating. The connection of the conductors is provided by crimping of flexible cables. It can also be carried out by tin soldering, if so, care should be taken to avoid damages on the insulation parts. On request contacts can be silver-plated. Moving contacts They are made of brass with wave shape to obtain an higher contact section (lower rise-temperature) and aid the tap changer self-positioning. On request, contacts can be supplied silver plated.

Voltages Voltage classes are allowed for: voltage max Earth withstand voltage class permissible Industrial frequency 50 Impulse 1/50 voltage Hz kv kv kv kv 20 30 24 36 50 70 125 170 According standard IEC 60214-1 2003-02 e IEC 60214-2 2004-10 Currents 10 A 30 A 60 A. Tests On tap changers, following our internal quality procedures, are carried out the routine tests and on some prototypes the type tests like rated short duration power frequency voltage tests, lightning impulse voltage, temperature rise test at rating current, short-circuit current test according to IEC standards. The insulating materials used are paper laminates and phenoplastic resins of E thermal class. Codes To identify tap changer type by series and code, proceed like example below reported: SERIES: 090 CODE: 090-06.07.236 06= type 07= bearing length L 70 mm 2 = voltage 20 kv 3 = current 30 A 6 = number of positions n 6 BEARING STANDARD LENGTH: 50-70-100-130-150-180-200 mm POSITIONS: standard from 3 to 7 positions, some kinds from 3 to 6. Please also specify type of control knob (see pages 090-60-1, 090-60-2, 090-60-3) Dimensions Dimensions reported in the following pages are in millimetres (mm). Modifications In case we need to modify some particulars, in order to improve the quality of our products, CAPT firma reserve an option to change without a previous warning. Substantial modifications will be surely communicated. Treatment the oven and / or under vacuum and lubrication It is recommended that the treatment is carried out at a maximum temperature between 100-110 C. After the treatment, before using the tap changer, you must lubricate carefully all the fixed and moving contacts of the tap changer, or alternatively, place the tap changer together with transformer active part in oil-filled transformer tank. Wait until the tap changer has come down to environment temperature before performing the first operation. Contact CAPT technical office when carrying out drying procedures at higher temperatures, or when carrying out special treatments. Maintenance (for the end-user) The tap changer does not require special maintenance. If the tap changer remains unused in a single position for a long period of time (months) during the maintenance of the transformer and with the transformer de-energised, we recommend to perform a series of operations on all the positions in order to clean the surface of the contacts. (see IEC60214-2 5.4.3 and 9.1.3)