EMERGENCY SERVICE GUIDE

Similar documents
HYBRID VEHICLE BATTERY

Hybrid Vehicle Emergency Response Manual

Hybrid. Australia s First Hybrid Truck. hino.com.au

Service Bulletin Trucks

2017~ Honda NSX Emergency Response Guide

Recycling Intermediate and High Voltage (IV/HV) Battery Packs from GM Hybrid, Electric and Electrified Vehicles

Emergency Response Guide

Emergency Response Guide

The information in this guide will allow response to emergencies involving Balance Hybrid E450 vehicles.

Emergency Response Guide

Travis County Emergency Services District #1 Standard Operating Guidelines

UKRO HYBRID VEHICLES. Challenge Hampshire 2010

Emergency Response Guide

Acura NSX Emergency Response Guide

2017 Acura MDX Sport Hybrid Emergency Response Guide. Prepared for Fire Service, Law Enforcement, Emergency Medical, and Professional Towing Personnel

HIGH VOLTAGE DISABLING

Emergency Services Guidance for Competition Electric Vehicles

Foreword About the Nissan Altima Hybrid Altima Hybrid Identification Hybrid System Battery Information High Voltage Safety

2014, Acura RLX Sport Hybrid Emergency Response Guide

Installation instructions

Service Bulletin Trucks

Emergency Response Guide

Freedom egen System End-of- Line Functional Checklist

Hybrid & Electric Cars Guidance for organisers of Speed events

ESCAPE HYBRID EMERGENCY RESPONSE GUIDE. Version 1.0

Installation instructions. Carbon Fiber Diffuser for the VW GOLF GTI (type MK VII.)

Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

2018 Honda Clarity Plug-In Hybrid Emergency Response Guide

2006/2007 ESCAPE HYBRID OR MARINER HYBRID

Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206

2007 Saturn VUE Green Line Hybrid Emergency Response Guide

TRIBUTE HYBRID EMERGENCY RESPONSE GUIDE ERG-08HEV

2018 Honda Accord Hybrid Emergency Response Guide

ARTICLE BEGINNING SERVICE PRECAUTIONS

2009 ESCAPE HYBRID MARINER HYBRID

South Magellan Drive, Torrance, California USA

C1219 C1219-STEERING ANGLE SENSOR ERRATIC PERFORMANCE RAM Pickup 6.7L Eng Search. 7/13/2015 Printer Friendly View

Honda Clarity Electric Emergency Response Guide


MODUL-CONNECT 1.2. Owner s Manual. Modular, digital wiring and control system. Document Part Number MSMC Rev 9 (04/18)

Gasoline-Electric Hybrid Synergy Drive

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Gasoline-Electric Hybrid Synergy Drive

Installation instructions

Eaton Hybrid First Responder Training Eaton. All rights reserved.

CAPACITOR ACTUATED PORTABLE STARTER CAPS USER GUIDE. INST048 Doc 3.01

Installation instructions

Installation instructions

Chevrolet Equinox Fuel Cell. Emergency Response Guide

Emergency Response Guide

Gasoline-Electric Hybrid Synergy Drive

IS300h. Gasoline-Electric Hybrid Synergy Drive. AVE30 Series

Contents. Introduction... Document Purpose... Vehicle Description... Soul Electric Vehicle Identification... General Vehicle Description...

Gasoline-Electric Hybrid Synergy Drive

Installation instructions

South Magellan Drive, Torrance, California USA

Installation Instructions for Load Management Kit A051C329

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

PRIUS. Gasoline-Electric Hybrid Synergy Drive. ZVW50/ZVW51 Series

Gasoline-Electric Hybrid

MP V 8A Electronic Smart Charger. Instruction and Information Manual

Installation instructions. Akrapovič Exhaust System: Evolution for the VW GOLF GTI (type MK VII.)

Installation instructions

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

Applications. Overview. Technical Specifications

Emergency Response Guide

CAMRY Hybrid. Gasoline-Electric Hybrid Synergy Drive. AXVH71 Series

230VAC Power Inverter 400W Owner s Manual

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

TESTER ISOLATION MODULE LIGHT SYSTEM. Operating Instructions. CAUTION Read this document before testing any snowplows.

Emergency Response Guide

2011 ESCAPE HYBRID MARINER HYBRID EMERGENCY RESPONSE GUIDE

Insulated Version M8 Stud (M12 Stud) Non-Insulated Version M8 Stud (M12 Stud) Aluminum Electrolytic Capacitors Accessories Mounting Kits

Installation Instructions 500 A Current Sensor Kit for F1 F4/F8 F13 Enclosure Sizes VLT Series FC 102, FC 202, and FC 302

Installation instructions

Installation instructions

NX300h. Gasoline-Electric Hybrid Synergy Drive. AYZ10/AYZ15 Series

2006 Model. 06Highlander Hybrid ERG REV (08/17/05)

JUMP STARTER OPERATOR S MANUAL RA1900

WGCT-A & WGCT-A/E TO REDUCE THE RISK OF INJURY, USER MUST READ INSTRUCTION MANUAL

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Models DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007

TRICKLE CHARGER MODEL NO: ATC12VB OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS LS0618 ISS 2

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AVALON Hybrid. Gasoline-Electric Hybrid Synergy Drive. AVX40 Series

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

OWNER S MANUAL MiniBoost

BATTERY SAVER LOW RIPPLE HO

Installation instructions. Akrapovič Exhaust Systems: Tail Pipes, Slip-On and Evolution for the Porsche 911 turbo (type 996T)

Derailment Detector Assembly

EBG Series Surface Preparation Machines

12V POWER PACK WITH 230V/A.C. OUTPUT INVERTER INSTRUCTIONS

Overspeed Adjustable Valve

EMERGENCY RESPONSE GUIDE

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

DC to DC Step Up Converter Model: VTC305

AGV5-1, AGV5-2 FORM AGV5 OM 11-02

RAV4 Hybrid. Gasoline-Electric Hybrid Synergy Drive

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Transcription:

HMSA EMERGENCY The purpose of this manual is to provide basic knowledge and understanding of the 300 Series Hybrid vehicle high voltage system For the assistance of SPECIAL EMERGENCY PERSONNEL in the rescue of Hino 300 Series motor vehicles. Rights for alteration to data and specification, at any time, are reserved. Any such alteration will be advised by the Product Support Division via Bulletins It is important to note, that the following information contained in this document is correct to our best knowledge, however errors may have occurred in its transcription. HMSA will not accept any liability for such errors. This document is only intended as a guide. Special Emergency Service Personnel must also refer to Hino Workshop Service Manuals, where applicable. Hino Motor Sales Australia 6-10 Parraweena Road, Taren Point, NSW 2224 Sydney Australia @ 2008 Publication # HMSA/EMERGENCY300HYBRID/0908 Version 1.2

HMSA EMERGENCY It is imperative that SPECIAL EMERGENCY personnel read and follow the correct safety guidelines, instructions and procedures contained herein before attempting to rescue the 300 Series Hybrid vehicle. The 300 Series hybrid vehicle utilises a high voltage system (300 Volts) to assist the Diesel engine as a mean of propulsion. In the event rescue personnel fail to follow the correct safety guidelines, precaution and instructions provided herein, have a greater risk of receiving an electrical shock, personal injury or even death. It is also important to note, that, the 300 Series Hybrid vehicle can only be serviced or repaired by trained personnel. Other parties involved in the service, repair or mounting body to this vehicle MUST have had an induction training prior to commencement of work. HMSA will not accept any liability for failing to follow the correct safety guidelines, instructions and procedures. Hino Motor Sales Australia 6-10 Parraweena Road, Taren Point, NSW 2224 Sydney Australia @ 2008 Publication # HMSA/EMERGENCY300HYBRID/0908 Version 1.2

CONTENTS 1) 300 SERIES HYBRID BROCHURE 2) EMERGENCY LINES..Pg 01 3) 24 VOLT CIRCUIT Pg 12 4) 300 VOLT CIRCUIT...Pg 20 5) HYBRID BATTERY Pg 29 6) LEAD-ACID BATTERY.Pg 36 7) SUPPLEMENTARY RESTRAINT SYSTEM...Pg 38 8) HYBRID VEHICLE RECOVERY...Pg 49

ISOLATION OF HYBRID BATTERY

EMERGENCY RESPONSE LINES EMERGENCY RESPONSE LINES On arrival, emergency personnel should follow their standard operating procedure to assist the vehicle involved in the accident. Emergency procedures involving the 300 Series vehicle Hybrid may be handled like other light duty trucks, however additional notes may assist the special service services personnel while dealing with Hino Hybrid vehicles. Warning! Never assume the 300 Series Hybrid vehicle electrical power is completely OFF because the vehicle is silent. Always observe Always observe the combination meter warning lights status to verify whether the ignition switch is set to the ON position. Immobilizing Vehicle Chock the vehicle s wheel and apply the parking brake. 1

EMERGENCY RESPONSE LINES EMERGENCY RESPONSE LINES CONT D Disabling the 24 Volt Vehicle System Performing any of the two procedures below will disable the vehicle 24 Volt system. 1) Disconnecting the (-) negative battery terminal, followed by disconnecting the (+) positive battery terminal to interrupt power supply to the vehicle electrical system. 2) With caution, snip the (-) negative battery terminal and then snip the (+) positive battery terminal avoiding contacting the metal chassis of the vehicle to avoid electrical sparks and cause a fire. (+) (-) 2

EMERGENCY RESPONSE LINES EMERGENCY RESPONSE LINES CONT D Disabling the 300 Volt Hybrid System Performing procedure (2) only will disable Hybrid system. 1) In the event the Safety Plug can not be reached, disconnect the (-) negative battery terminal, followed by disconnecting the (+) positive battery terminal to interrupt power supply to the vehicle electrical system and Hybrid system. 2) When removing the Control Power Unit Safety Plug, allow 5 minutes for the system capacitor to discharge. After this time period, the vehicle can then be rescued. REFER PAGE 5 3

EMERGENCY RESPONSE LINES It is imperative that the Hybrid Battery be isolated before any type of work is commenced with the Hybrid vehicle (e.g. Vehicle servicing, removal of manual transmission, clutch replacement, repair to the Hybrid Control Power P Unit or any other work while the vehicle is being serviced / repaired at the Dealership). It is also important to note that the Dutro Hybrid vehicle must be serviced only by authorised Hino Dealerships and authorised trained service personnel. The failure to follow this guidelines may result in damage to the e vehicle and personal injures, resulting in death! 4

EMERGENCY RESPONSE LINES DO NOT USE IF 5

EMERGENCY RESPONSE LINES 6 x 10 mm Hexagon Head 6

EMERGENCY RESPONSE LINES SLIDE TO THE RIGHT 7

EMERGENCY RESPONSE LINES 150 A Fuse 8

EMERGENCY RESPONSE LINES 9

EMERGENCY RESPONSE LINES SLIDE TO THE LEFT 10

EMERGENCY RESPONSE LINES 11

24 VOLT CIRCUIT

24 VOLT ELECTRICAL SYSTEM 24 VOLT SYSTEM Hybrid Vehicle (HV) 24 Volt System Wear Protective safety clothing at all times! The 24 Volt system in the 300 Series vehicles is independent of the 300 Volt system. Although there are a number of components in the Hybrid Control Power Unit that is operated by a 24 / 12 Volt power supply, the Hybrid Control Power Unit must be treated as a high voltage system. 24 Volt Electrical Circuit The electrical wiring diagrams included in this section relates to systems that operate with 24 / 12 Volt power supply. A Red Tick next to the electrical circuit description identifies circuits that can be cut through with Jaws of Life 12

24 VOLT ELECTRICAL CIRCUIT 24 VOLT EQUIPMENT 13

24 VOLT ELECTRICAL CIRCUIT JAWS OF LIFE CAN BE USED ON THIS CIRCUITS 24 VOLT CIRCUIT 14

24 VOLT ELECTRICAL CIRCUIT JAWS OF LIFE CAN BE USED ON THIS CIRCUITS 24 VOLT CIRCUITS 15

24 VOLT ELECTRICAL CIRCUIT JAWS OF LIFE CAN BE USED ON THIS CIRCUITS 24 VOLT CIRCUIT 16

24 VOLT ELECTRICAL CIRCUIT JAWS OF LIFE CAN BE USED ON THIS CIRCUITS 17

24 VOLT ELECTRICAL CIRCUIT JAWS OF LIFE CAN BE USED ON THIS CIRCUITS 24 VOLT CIRCUIT 18

24 VOLT ELECTRICAL CIRCUIT JAWS OF LIFE CAN BE USED ON THIS CIRCUITS 19

300 VOLT CIRCUIT X

300 VOLT HYBRID SYSTEM 300 VOLT HYBRID SYSTEM Hybrid Vehicle (HV) 300 Volt System Wear Protective safety clothing at all times! The 300 Volt system in the 300 Series vehicles is independent of the 24 Volt system. Although there are a number of components in the Hybrid Control Power Unit that is operated by a 24 / 12 Volt power supply, the Hybrid Control Power Unit must be treated as a high voltage system. 300 Volt Electrical Circuit The electrical wiring diagrams included in this section relates to systems that operate with HIGH VOLTAGE 300 VOLT POWER SUPPLY. A Cross placed on top of the Jaws of Life and also next to the electrical circuit description indicate electrical circuits that can NOT be cut through with Jaws of Life X 20

HYBRID SYNERGY DRIVE COMPONENTS Jaws of life CAN NOT be used Synchronous Electric Motor Clutch Transmission Diesel Engine U V W Nickel Metal Hydride Battery 300 Volts Inverter HV ECU DC ~ AC CPU (Control Power Unit) 21

HYBRID SYNERGY DRIVE COMPONENTS X 22

HYBRID SYNERGY DRIVE COMPONENTS 23

HYBRID SYNERGY DRIVE COMPONENTS Jaws of life CAN NOT be used 300 VOLTS SYSTEM X 24 VOLTS SYSTEM 300 VOLTS SYSTEM 24

HYBRID SYNERGY DRIVE COMPONENTS Jaws of life CAN NOT be used X 300 Volts 300 Volts 24 Volts Nickel Metal Hydride Battery Inverter Assembly HV ECU 25

HYBRID SYNERGY DRIVE COMPONENTS Jaws of life CAN NOT be used X 300 VOLTS X 300 VOLTS CONTROL POWER UNIT 26

HYBRID SYNERGY DRIVE COMPONENTS Jaws of life CAN NOT be used X X 27

HYBRID SYNERGY DRIVE COMPONENTS Jaws of life CAN NOT be used X X X 28