NSB OPzV Batteries. Tubular Gel Technology. NSB OPzV Battery Application Manual. northstarbattery.com

Similar documents
Page Section Title 3 1 Introduction 3 2 Charge 5 3 Heat and Temperatures 5 4 Discharge 6 5 Useful Life 7 6 Hybrid Operation Cyclic Operation 8 7

NorthStar Battery (NSB) Telecom Application Manual

POWER FOR TOMORROW. Motive Power. Network Power. Chargers. Bloc Batteries. Accessories. Service

PowerSafe OPzV Operation Guide for Solar Applications

PowerSafe OPzV Operation Guide for Solar Applications

Form: SES Issued: ECO

EcoSafe EOPzV. Operation Guide for Solar Applications

NorthStar Battery Company DCN: SES DCR: 1548-S09 Date:

Features and Benefits

Table of Contents AGM Thin Plate Pure Lead - High Rate

Charging of HOPPECKE OPzV solar.power battery in Solar Applications

Chapter 6. Batteries. Types and Characteristics Functions and Features Specifications and Ratings Jim Dunlop Solar

SPA AGM VRLA batteries

IEEE IAS Atlanta Chapter

2 Volt AGM Range. Haze Battery Company Ltd

Tubular Gel Technology For Solar Applications

Pure Lead-Tin Technology

Haze Battery Company Ltd

RES OPzV Premium Quality Batteries. for Renewable Energy Storage

RES OPzV Premium Quality Batteries. for Renewable Energy Storage

NorthStar Battery Company DCN: SES DCR: 1413-S08 Date:

NorthStar Battery Company DOC Code: SES DCR-721-S05 Date:

Haze Battery Company Ltd. Sealed Lead Acid 2 Volt Bloc. Gelled Electrolyte Range

Stationary Energy Storage Valve Regulated Lead-Acid Batteries. LL Series

FIAMM Industrial Batteries December 2012 FIAMM AGM Valve Regulated Recombination Batteries: FLX Series- Engineering Manual TABLE OF CONTENTS

INTRODUCING THE LEAD CRYSTAL BATTERY

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. Gelled Electrolyte Range. Monobloc

Batteries and more. Powered by (CE, UL & ISO9001 APPROVAL)

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

FLUSH EYES IMMEDIATELY WITH WATER. GET MEDICAL HELP FAST. SULFURIC ACID CAN CAUSE BLINDNESS OR SEVERE BURNS.

Haze Battery Company Ltd

Power to keep you on the move

Valve Regulated Lead Acid Batteries

Modular Max Range BATTERY SOLUTIONS. NEBS qualified. Reliable capacities. EverExceed power your applications

VRLA Batteries. Battery Installation And Start up Guide

6 & 12 Volt Monobloc GEL Range

Wide operating temperature range: Our battery will operate from -30C to (-22F) to 60C when it is fully charged.

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

Applications. EMC tested

Haze Battery Company Ltd

OPzV Batteries for Stationary Applications

12 VDC Power Sources For Your RV

HAZE 6/12 Volt. STATIONARY 6/12 Volt BATTERIES. HAZE Battery Co. INSTALLATION and OPERATING INSTRUCTIONS. Supplied Worldwide by :

6 & 12 Volt Monobloc. Haze Battery Company Ltd

Reserve Power OPzV Batteries

Reserve Power OPzV Batteries

UZB GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY REPLACEMENT BATTERY REPLACEMENT 12V, 12AH 1/6.

12 VOLT 30 AMP DIGITAL SOLAR CHARGE CONTROLLER

Polymer Gel Standby Battery (Front Access Design) OPERATION MANUAL

Charge Voltage(V/cell) Set point (V) (V)

Pb battery. Chemical equation: Pb+2 H 2 SO 4. + PbO 2 <charge. 2 PbSO 4 +2 H 2. discharge>

IEC APPROVAL TESTS

Modular Max AGM Range VRLA

MHR VRLA batteries are manufactured in compliance with TL, NEBS, GR, SR, IEC, BS, UL, ISO, OSHAS and CE quality and performance standards.

2 VOLT STATIONARY BATTERIES INSTALLATION

NARADA POWER SOURCE CO., LTD.

Valve regulated sealed industrial battery. HAGEN OPzV

PRODUCT GUIDE RESERVE POWER

Batery SERIES. VALVE REGULATED LEAD ACID BATTERies INFINITE POWER. Mission Critical Applications. All Battery Range

OPzV Batteries. for Stationary Applications

OPzV Batteries. for Stationary Applications

LITHIUM IRON PHOSPHATE BATTERY Multi-application - LiFePO4 Power

Technical Note. Management of Sealed Lead Acid Batteries in Reliable Small DC Standby Power Supply Systems

The Traveler Series TM : Adventurer

VGS. series (OPzV) GLOBAL OPzV Valve Regulated Sealed Industrial Battery

Lithium battery charging

Duo Battery Charge Controller

AINO MICRO RANGE VRLA. Compact energy for increased security BATTERY SOLUTIONS. EverExceed power your applications

LITHIUM IRON PHOSPHATE BATTERY Multi-application - LiFePO4 Power

Low maintenance TAB OPzS vented stationary batteries

SOLAR CHARGE CONTROLLER

Tubular Gel (OPzV) Batteries. Stationary & Renewable Energy Applications

The Traveler Series: Wanderer

Batteries for Renewable Energy Applications

[Charge] [Lead dioxide] [Lead] [Sulfuric acid] [Lead sulfate] [Lead sulfate] [Water]

Battery Storage Systems

The Traveler Series: Adventurer

PV System Components. EE 495/695 Spring 2011

Product Guide. An Invensys company

Battery. Student booklet

DIAGNOSTIC POWER SUPPLY WSC 720. user guide. 12 V/24 V lead acid batteries ah

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

The Traveler Series: Wanderer

PURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

Deep Cycle Battery Safety. First. Battery Handling, Maintenance & Test Procedures

F R O N T T E R M I N A L PRODUCT GUIDE Publication No: EN-VFT-PG-001 February 2003

Tubular Flooded (OPzS) Batteries

Intelligent Charging System Series

NI-MH LOW-SELF DISCHARGE READY TO USE

VRLA gel battery. power the future

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Cruising Charger Series OWNER S MANUAL

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER BATTERY CHARGER! For your personal safety read, understand and follow the information provided in

Chapter 3. Direct Current Power. MElec-Ch3-1

NSB Solar Battery Range Designed for off grid applications

The introduction of Lead Crystal Battery

SCC-MPPT Solar Charge Controller

Installation and Operating Instructions. Solar System Controller ISC3020

Solar Charge Controller

Transcription:

northstarbattery.com NSB OPzV Batteries Tubular Gel Technology NSB OPzV Battery Application Manual

Table of Contents Tubular Gel Technology Application Page Section Title 3 1 Introduction 3 2 Description 3 3 DIscription of Function 3 4 Accomodation 4 5 End of DIscharge Voltage (EODV) 4 6 Discharge Rate 4 7 Float Charge 5 8 Operation of battery in standby on unreliable grid 5 9 Charge Current Limit 5 10 Charging Time 5 11 Commissioning charge 5 12 IU Charge 5 13 Equalizing or boost charge 6 14 Operating Temperature 6 15 Storage Times 6 16 Installation 6 17 Temperature effect on float life 7 18 Cycle Life at Different Depth of Discharge (DOD) 7 19 Temperature Effect on Cycle Life 7 20 Operation Guidance for Hybrid Applications 7 21 Operation Guidance for Solar Applications Installation Page Section Title 8 22 Installation & Safety Instructions 8 23 General 8 24 Requirements and Preparations for Installation 8 25 Racks 9 26 Putting the Cells into Place 9 27 Connecting the Cells 9 28 Putting the Batteries Into Operation 9 29 Maintenance 9 30 Storage 9 31 Transport 9 32 Contact

1 3 Introduction 1 NorthStar s OPzV series of batteries are designed for excellent cycling capability, long float life and high reliability to ensure trouble-free backup power for a wide variety of applications. For example: 1) 2) 3) 4) 5) 6) 7) NSB 6 OPzV 600 Hybrid/cycling applications with long backup times Base stations Long back up times with higher load for remote base stations Solar and wind sites UPS Utility and switchgear Peak shaving applications and more 5 6 OPzV TUBULAR PLATE TECHNOLOGY CAPACITY 2V 714 Ah, C/10 to 1.80VPC @ 20ºC / 68ºF 2V 722 Ah, C/8 to 1.75VPC @ 25ºC / 77ºF 4 TERMINAL TORQUE 22 Nm / 195 in-lb CHARGE VOLTAGE Float: 2.25 VPC @ 20ºC / 68ºF Cyclic: 2.25-2.40 VPC A NorthStar Battery Company product Manufactured in the UAE www.northstarbattery.com Sections 1 through 19 are applicable for both series. Sections 20 and 21 are operation guidelines for solar and hybrid applications. General installation and maintenance guidelines for both series is in sections 22 through 32. 2 Description NorthStar s OPzV product family includes two different series of batteries: a standby battery (OPzV series) with slightly higher capacity and a solar battery (Solar OPzV series) that is optimized for longer cycle life. The OPzV Solar contains an addition of phosphoric acid which extends cyclic life at the expense of capacity, please consult capacity tables for guidance. The OPzV product line is intended for back-up and cyclic applications. All NSB OPzV batteries utilizes a robust tubular positive electrode design with maintenance-free and leakage-free construction through electrolyte suspension in fumed silica gel. 2 3 The design encompasses two very reliable design elements, the gelled electrolyte and the tubular positive plate. The gelled electrolyte mean that the cells can work both upright and lying down without stratification occurring. The tubular plate design mean that the active material is confined very strongly to the grid which mean that the active material remains in very good contact enabling a multitude of cycles. The NSB OPzV/Solar uses active materials which mean that the water losses are kept to a minimum. 4 6) Terminal with rubber grommet and brass insert Battery container in ABS material Valve assembly with umbrella valve and filter Negative grid (Here shown without paste) Positive grid with tubular gauntlet (Here shown without active material for clarity) Micro-porous separator of with ribs Accomodation Batteries built from OPzV cells need accommodation fulfilling the following. Dry and cool place Air flow for cooling Air exchange to expel hydrogen Place in front for servicing The schematic drawing in the drawing below illustrates the many component parts of a NSB OPzV cell: 1) 2) 3) 4) 5) Description of Function Dry and cool place The recommended temperature range is 10 C-30 C. Operation outside of this range is permitted observe that the life is shorter at elevated temperature and capacity is stated at 20 C. 3 Form: SES-544-01330-03 Issued: 07-21-17 ECO-101521

Air flow for cooling Where batteries are used in a cyclic duty one needs the air to move around the cells because heat is generated when the cells are cycled. As a rule the estimated losses can be up to 15% of the discharged energy. An example: A 48 V battery is discharged twice a day delivering 4 h back-up and 2 kw of power each instance. ( 42 A x 4 h approximately ) Then the heat that needs to be removed can be estimated. Qloss (heat loss from the battery) = 2(twice a day) x 2 kw x 4 h x 0,15 = 2400 Wh. If we distribute this over the 24 h we have an average cooling demand of: Pcooling (cooling power to keep a consistant temperature) = 2400Wh/24h = 100 W Air exchange to expel hydrogen Valve regulated batteries emit some hydrogen due to unavoidable reaction occurring in the cells. It is a slow process and the amounts are minimal. NorthStar Battery recommends the international standard for safety of stationary batteries to be followed, IEC 62485-2. 6 Discharge Rate In this document, the charge and discharge rates (Amps) are expressed as multiples of I10, where I10 is the current for a 10-hour discharge to 100% Depth-Of Discharge (DOD). These values serve to normalize data across a range of battery cell sizes. Consider the following example: 10-h discharge capacity NSB 6 OPzV 600 = 714 Ah (EODV = 1.80 VPC @ 25 C). 1 x I10 = 1 x (10-h discharge current) 1 x I10 (NSB 6 OPzV 600) = 1 x 71.4 A = 71.4 A 2 x I10 (NSB 6 OPzV 600) = 2 x 71.4 A = 142.8 A 7 Float Charge The recommended float voltage is 2.25 VPC at +20 C (+68 F) with a tolerance of ±1%. If the battery cell temperature increases above this level, a thermal compensation of -3.5 mv/cell/ C is required for safe operation and achieving optimal life. Conversely, if the temperature decreases below 20 C, the voltage should be increased by 3.5 mv/ cell/ C. See graph below: In essence this mean that the battery needs ventilation that corresponds to the total amount of the cells and their capacities. NorthStar uses this as an example of the needs of a nominally 48 V 1000 Ah battery (consisting of 24 cells) With float only With boost voltage 1,3 m3/h 6,8 m3/h 5 End Of Discharge Voltage (EODV) Discharging too much capacity from the batteries is detrimental and each battery installation shall have protection for overdischarge. A minimum End-Of-Discharge Voltage (EODV) should be used to avoid over-discharge. The EODV must be adjusted based on the intended discharge times. The following table provides a guide for EODVs at various discharge rates. Discharge times (Hours) EODV 1-3 1.67 V 3-8 1.75 V 8-24 1.80 V 24-240 1.85 V 4

8 Operation of the battery in standby operation with frequent power interruptions 16 hours at constant voltage of 2.35 VpC at 20 C (68 F) to 25 C (77 F). Current limitation: 1.5 x I10. During operation of the battery in standby applictions with frequent power interruptions it is recommend that the boost charge functionality of the power system is turned on. (The boost charge increases the voltage setting for the charge above the float charge voltage and is turned on if a substantial discharge has occurred). The duration of the boost charge should not be longer than 5 hours at the boost charge level alternatively it can be turned off earlier if the current has decreased to a low value < 0,05*C10. The reccommended boost charge voltage is 2.35-2.40 V per cell. OCV / V 2.20 2.15 2.10 2.05 2.00 OCV vs State of Charge Solar Standard 9 Charge Current Limit 1.95 100 80 60 SOC % 40 20 0 After a discharge the battery can be recharged at the float charge voltage. The battery charging current should be limited to 5 x I10. 10 Charging Time Typical recharge behavior can be estimated according to the following chart. % State of Charge 120 100 80 60 40 20 0 NSB Recharge Curves 2.35VPC 2 x I 10 @ 20 C 100% DoD 75% DoD 50% DoD 25% DoD 0 5 10 15 20 25 Charge Time /hours 12 IU Charge The IU charge is normally used for fast recharging or in cycle use. IU charge consists of two phases: 1st phase: Constant current-recommended rate 2 to 5 x I10. The voltage increases up to a limited voltage of 2.35 VpC. 2nd phase: Constant voltage of 2.35 VpC. The absorbed current decreases. Once the current has reached a low and constant value (approx. 0.005A per Ah) the battery should be considered fully charged and the rectifier/charger voltage adjusted to the temperature compensated float level (2.25VPC @ 20 C). For safety reasons, the second phase should not last more than 10 hours. 13 Equalizing or Boost Charge After deep discharges or after repeated inadequate recharging an equalizing or boost charge shall be carried out using the settings in the commissioning charge paragraph. 11 Commissioning charge Batteries lose charge while in transit or during storage. For this reason, a freshening charge should be given before putting the battery into service. Recommended charge settings at the ambient temperature range of 20 C to 25 C are as follows: 5

14 Operating Temperature The permissible operating temperature range is -20 C to 55 C. The recommended operating temperature range is +10 C to +30 C. All technical data in this document relates to the rated temperature of +20 C (if not otherwise specifically stated). Higher temperatures reduce the operational life and lower temperatures reduce the available capacity. 15 Storage Times Storage time for charged cells is limited and dependent on storage temperature. The recommended maximum storage time is as follows: Storage temperature 20 C 30 C 40 C OPzV 24 months 13 months 7 months Stored OPzV batteries must be recharged @ min 50% capacity. During the storage time, the Open Circuit Voltage (OCV) must periodically be checked. Battery cells with OCV below 2.10 VpC must be recharged providing constant voltage of 2.35 VpC with current limitation of 0.15 C10 (A), for 24 hours. The OCV of a fully charged battery should be between 2.12-2.14 VpC. Failure to observe the above conditions may result in a greatly reduced capacity and service life or in permanent damage to the cells. 16 Installation The rack location and ventilation system should be such that the maximum temperature differential between cells does not exceed 3 C (5 F). A minimum distance of 10 mm is recommended between each cell to allow for airflow and cooling of the cells. Do not expose cells to direct sunlight in the final installation, avoid direct sunlight during transportation and installation phase. Operation (non-cycling) Any position allowed, no restrictions in capacity. Note: if cells are exposed to higher temperature fluctuations please contact, application engineering department. Operation (cycling) Any position allowed up to NSB2-1800. For any higher capacity contact application engineering. Vertical, upright installation no restrictions. Horizontal operation allowed up to NSB2-1800. For any higher capacity contact application engineering. 17 Temperature Effect on Float Life Under normal standby operation, or float operation, the OPzV batteries are being constantly over-charged. This small overcharge is an effect of the float current and this happens in all float applications. Due to this small overcharge, over time, the lead within the positive plates undergo slow corrosion, which is a normal aging mechanism. NSB OPzV cells can be installed vertically, standing, or horizontally, laying down in suitable racks. When storing horizontally ensure that the internal plates are vertical (to check this is correct, the positive and negative terminals should be above or below each other, i.e. not on the same level, as per diagram below): 6

The rate of this process increases with increasing temperature and, as a result, the temperature of cells has a large effect on their float life. Life / Years 25 20 15 10 5 Float life vs temp 0 15 25 35 45 Average temperature C For example, if the temperature rises from the recommended operating temperature of +20 C, to +45 C, the expected life of the battery cells will decrease from 20-years to approximately 4-years. 18 Cycle Life at Different Depth of Discharge (DOD) The Depth of Discharge (DOD) of the OPzV battery has a significant impact on the number of charge/discharge cycles that can expected from the battery throughout its lifetime. DOD is expressed as a percentage of rated capacity delivered during discharge. The following chart can be used to estimate the cycle life of NorthStar OPzV Solar batteries. 16000 NSB Solar OPzV cycles 19 Temperature Effect on Cycle Life Temperature also has a marked effect on the cycle life of an OPzV battery. As the temperature increase from 20 C the cycle life decreases 20 Operation Guidance for Hybrid Applications NSB Solar is designed for repeated cyclic duty as will occur for instance when stand-alone Diesel Generating sets are operated together with batteries in order to decrease the run time of the Diesel generators. It is recommended that the charging time shall be long enough to fully charge the battery between cycles. Guidance on design values for the charging time will be found in section 10 and end-of charge criteria will be found in section 12. Design value for the numbers of cycles achievable depending on depth of discharge (DOD) is found in section 18. 21 Operation Guidance for Solar Applications Solar photovoltaic operation: The batteries are used where a generator is not available and the batteries are charged using photovoltaic panels when the sun shines and where the batteries provide necessary power during times when there is too little sunshine. In this application, it is necessary to control the amount of charge in times of plentiful sunshine. For the times of prolonged darkness, it is advisable to not deplete the batteries too much by observing the recommended endof discharge voltages. Cycles 14000 12000 10000 8000 6000 4000 2000 0 25 C 20 C 0 10 20 30 40 50 60 70 DOD % For example, if a 1000Ah cell delivers 100Ah during a discharge period then the DOD would be 10%. As the DOD per cycle increases, the cycle life of the cell will decrease. 7

22 Installation and Safety Instructions 23 General Pb Pb Please read and observe the installation and operation instructions in this document. When working on batteries wear appropriate Personal Protective Equipment (PPE). As a minimum (depending on area and location more may be required) safety glasses with side shields, rubber gloves and protective clothing. All metallic personal objects, such as rings, watches, bracelets, etc. should be removed before starting work on the battery Do not expose the battery to an open flame or other ignition source. During operation an explosive mixture of hydrogen gas may accumulate. Battery terminals are always energized and, if short-circuited, cause electrical arcing. Always use insulated tools. Batteries are heavy objects. Use proper handling equipment safety gear during installation. Inappropriate lead acid battery disposal can result in environmental contamination. Please dispose of batteries according to local regulations. Battery may be returned, shipping pre-paid, to the manufacturer or any distributor for recycling. Batteries contain concentrated sulfuric acid in water. Any fluid found outside the batteries should be regarded as acid. Clean all acid splash in eyes or on skin with plenty of clean water. Then seek medical help. Acid on clothing is to be washed with water Risk of explosion or fire. Avoid any short circuit. Metallic parts under voltage on the battery, do not place tools or items on top of the battery. Valve regulated batteries of gelled tubular type OpzV do not need water additions during operation. Safety regulations may apply depending on which country the batteries is installed. In absence of specific local regulation NorthStar Battery recommends that IEC 62485-2 is followed. 24 Requirements and Preparations for Installation 1. Before installation ensure that the battery room/ cabinet is clean and dry and is furnished with a lockable door. Check that the room/cabinet is marked according to local regulations. The IEC 62485-2 gives guidelines on how to find the necessary ventilation for a given amount of batteries based on its size (number of cells and capacity). Local regulations may require other ventilation demands. In general rooms that are not sealed on purpose will provide necessary ventilation while cabinets need to be designed for batteries. 2. Check deliveries for completeness and damage. If necessary, clean all parts before assembling. 3. Observe all documentation included with the delivery (e. g. battery-, rack-, cabinet-assembly drawings). 4. Before replacing old batteries ensure that all electric leads are switched off. 5. Open-circuit voltage measurements of individual cells or block batteries. Ensure correct polarity. 25 Racks Usage of the battery which does not comply with the OPERATING INSTRUCTIONS, repairs carried out with spare parts not approved by the supplier, use of additives in the electrolyte or unauthorised interference with the battery will invalidate any claim for warranty. Pb Used batteries with this symbol are reusable goods and must be returned to the recycling process or must be disposed in accordance with the rules of the country concerned. Pb Align the racks according to the installation drawing. The placement of the racks/cabinets in the room should be such as to make the servicing of the cells easy Leave enough free space in front of the batteries. In absence of local regulations the IEC 62485-2 shall be consulted. Also to be considered is that the battery racks/cabinets are all placed in a similar temperature. If the racks are placed in different temperatures their operation is compromised As a rule of thumb the temperature difference should be less than 3 C. 8

26 Putting the Cells into Place For heavy cells use lifting implements to assist putting the cells in place. In the first hand lift the cells into position. When lifting is not possible and sliding has to be used Take every precaution to avoid scratching the cells! When putting cells into horizontal position in shelves Remember to orient the terminals the right direction. Look in the assembly drawing for the battery for correct orientation. 27 Connecting the Cells Start with connecting the intercell connectors. Observe where the end terminals shall be according to the assembly drawing.connect the cells with the connectors that have been supplied and observe the torque setting 22 Nm when tightening the bolts. When all the cells have been connected Check the terminal voltage! It should be the sum of all voltages. If it deviates some of the units may have been reversed. Check again and reorient the misplaced unit. 28 Putting the Batteries into Operation Check that the circuit breaker is in off position. Verify with a volt meter. Turn on the system and verify that the positive battery cable has the right polarity, ie positive. Turn it off again. Connect the battery cables at the power system side and then connect them at the battery terminals. Then turn the power system on. 29 Maintenance Every 6 months stand by operation The individual voltages and float currents shall be measured and recorded as well as surface temperatures. Cleanliness of battery shall be checked. For the first 12 month of operation the variations in cell voltages is expected to be high. (2,14 V< U < 2,50 V) If deviations do not decrease after 12 months of operation the battery needs additional equalization. 30 Storage The battery should be stored in a dry cool place. If temperature is high the battery needs to be recharged whenever the average cell voltage is below 2,08 V per cell. 31 Transport Batteries showing no damage are not treated as dangerous goods according to the road and railway regulations if they are protected against short circuits, sliding, overturning, damage as well as secured and stacked on pallets in a suitable way. 32 Contact Information NorthStar Americas NorthStar Battery Company LLC 4000 Continental Way Springfield, MO, 65803. United States of America info@northstarbattery.com Tel: +1 417 575 8200 Fax: +1 417 575 8250 NorthStar Europe SiteTel Sweden AB Haukadalsgatan 8 A SE-164 40 Kista Stockholm, Sweden europe@northstarsitetel.com Tel: +46 8 410 102 00 Fax: +46 8 638 06 00 NorthStar Middle East. Africa NorthStar Battery DMCC Office 702, Saba 1 Tower Jumeirah Lake Towers, Dubai United Arab Emirates mea@northstarsitetel.com Tel: +971 4 423 8060 Fax: +971 4 423 8061 NorthStar Asia-Pacific NS Asia Pacific Sdn. Bhd. B2-3A-13A Solaris Dutamas No. 1. Jalan Dutamas 1 50480 Kuala Lumpur, Malaysia asia@northstarbattery.com Tel: +60 3 6419 0711 NorthStar China Northstar Group Room 1111, International Commerce Chamber Fuhua 3 RD Shenzhen, China china@northstarsitetel.com Tel: +86-755-23832313 9