DIESEL GENERATOR SET MTU 20V4000 DS2650

Similar documents
DIESEL GENERATOR SET DP03000D5S

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET DP01800D5S

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 20V4000 DS3100

DIESEL GENERATOR SET MTU 12V4000 DS2000

DIESEL GENERATOR SET DS03200D5S

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET DS01650D5S

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 20V4000 DS3250

DIESEL GENERATOR SET MTU 18V2000 DS1400

DIESEL GENERATOR SET MTU 16V2000 DS1000

DIESEL GENERATOR SET MTU 16V2000 DS KVA

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 16V2000 DS1100

DIESEL GENERATOR SET MTU 12V4000 DS1750

DIESEL GENERATOR SET MTU 12V4000 DS2250

DIESEL GENERATOR SET MTU 20V4000 DS3300

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 20V4000 DS4000

DIESEL GENERATOR SET MTU 20V4000 DS3600

KVA KW KVA KW

DIESEL GENERATOR SET MTU 10V1600 DS500

DIESEL GENERATOR SET DG00660D5

DIESEL GENERATOR SET MTU 4R0113 DS80

POWER MODULE MTU 16V4000 DS2560

DIESEL GENERATOR SET MTU 12V1600 DS660

KVA KW KVA KW

KVA KW KVA KW

20' STANDARD CONTAINER MTU 16V2000 DS: kva MTU 18V2000 DS: kva

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

PRODUCT PRESENTATION SERIES kva. MTU Onsite Energy Systems GmbH All rights reserved

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Standby Rating 220/ / / / / /

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

STANDBY 720 ekw 900 kva 50 Hz 1500 rpm 400 Volts

3412C Generator Set Electric Power. Specifications. Benefits and Features

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

Voltage 220 to or 1800 RPM

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Part III : Technical Specification POS C)

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

PRIME 225 ekw 281 kva

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

P R I M E e k W k V A 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data

DIESEL GENERATOR DATA SHEET

Model NA 2 L

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

220 to volts. Electronic unit injection

Specifications. 3406C Generator Set Electric Power

Prime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

Engine Specifications C32 ACERT TA, V-12, 4-stroke Water-cooled Diesel. Compression Ratio 15.0:1 Turbocharged Aftercooled.

DIESEL GENSET. Prime 60Hz 91 kw / 114 kva

See Note. 100% of rated load. Mechanical efficiency ISO3046/1 2,4,7 35.2% 34.8% 34.1% Electrical efficiency ISO3046/1 2,4,6,7 33.7% 33.4% 32.

See Note. 100% of rated load

Generator Set Specifications Rating (ekw) Rating (kva) Engine Specifications C32 ACERT TA, V-12, 4-stroke Water-cooled Diesel

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

STANDBY 650 ekw 812 kva 60 Hz 1800 rpm 480 Volts

Continuous, Prime, Standby, Mission Critical

STANDBY 200 ekw 250 kva

Transcription:

DIESEL GENERATOR SET MTU 20V4000 DS2650 380V 11 kv/50 Hz/Prime Power/TA-Luft Optimized MTU 20V4000G23/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS // Benefits - Low fuel consumtion - Optimized system integration ability - High reliability - High availability of power - Long maintenance intervals // MTU Onsite Energy is a single-source supplier // Support - Global product support offered // Standards - Engine-generator set is designed and manufactured in facilities certifi ed to standards ISO 2008:9001 and ISO 2004:14001 - Generator set complies to ISO 8528 - Generator meets NEMA MG1, BS5000, ISO, DIN EN and IEC standards - NFPA 110 // Power Rating - System ratings: 2500 kva - 2600 kva - Accepts rated load in one step per NFPA 110 - Generator set complies to G3 according to ISO 8528-5 - Generator set exceeds load steps according to ISO 8528-5 // Performance Assurance Certification (PAC) - Engine-generator set tested to ISO 8528-5 for transient response - 75% load factor - Verifi ed product design, quality and performance integrity - All engine systems are prototype and factory tested // Complete range of accessories available - Control panel - Circuit breaker/power distribution - Fuel system - Fuel connections with shut-off valve mounted to base frame - Starting/charging system - Exhaust system - Mechanical and electrical driven radiators - Medium voltage alternators // Emissions - TA-Luft optimized // Certifications - CE certifi cation option

2 / / / MTU 20V4000 DS2650 / 50 Hz / 380V - 11kV APPLICATION DATA ➀ // Engine Manufacturer MTU Model 20V4000G23 Type 4-cycle Arrangement 20V Displacement: l 95.4 Bore: mm 170 Stroke: mm 210 Compression ratio 16.4 Rated speed: rpm 1500 Engine governor ADEC (ECU 7) Max power: kwm 2200 Air cleaner Dry // Fuel System Maximum fuel lift: m 5 Total fuel flow: l/min 27 l/hr g/kwh At 100% of power rating: 585.8 221 At 75% of power rating: 423.4 213 At 50% of power rating: 284.9 215 // Liquid Capacity (Lubrication) Total oil system capacity: l 390 Engine jacket water capacity: l 205 Intercooler coolant capacity: l 50 // Combustion Air Requirements Combustion air volume: m 3 /s 3.2 Max. air intake restriction: mbar 50 // Cooling/Radiator System Coolant flow rate (HT circuit): m 3 /h 80 Coolant flow rate (LT circuit): m 3 /h 32.5 Heat rejection to coolant: kw 970 Heat radiated to charge air cooling: kw 470 Heat radiated to ambient: kw 105 Fan power for mech. radiator (40 C): kwm 70 // Exhaust System Exhaust gas temp. (after turbocharger): C 530 Exhaust gas volume: m 3 /s 8.7 Maximum allowable back pressure: mbar 85 Minimum allowable back pressure: mbar 30 ➀ All data refers only to the engine and is based on ISO standard conditions (25 C and 100m above sea level). ➁ Values referenced are in accordance with ISO 3046-1. Conversion calculated with fuel density of 0.83 g/ml. All fuel consumption values refer to rated engine power.

3 / / / MTU 20V4000 DS2650 / 50 Hz / 380V - 11kV STANDARD AND OPTIONAL FEATURES // System Ratings (kw/kva) Generator model Voltage TA-Luft optimized 40 C/400m without radiator with mechanical radiator with electr. driven radiator kwel kva* AMPS kwel kva* AMPS kwel kva* AMPS Marathon 1020FDL7093 380 V 2080 2600 3950 2040 2550 3874 2040 2550 3874 (Low voltage 400 V 2080 2600 3753 2000 2500 3608 2000 2500 3608 marathon standard) 415 V 2080 2600 3617 2000 2500 3478 2000 2500 3478 Marathon 1030FDL7094 380 V 2080 2600 3950 2040 2550 3874 2040 2550 3874 (Low voltage 400 V 2080 2600 3753 2000 2500 3608 2000 2500 3608 marathon oversized) 415 V 2080 2600 3617 2000 2500 3478 2000 2500 3478 Leroy Somer LSA 53.1 M80 380 V 2080 2600 3950 2040 2550 3874 2040 2550 3874 (Low voltage 400 V 2080 2600 3753 2040 2550 3681 2040 2550 3681 Leroy Somer) 415 V 2080 2600 3617 2040 2550 3548 2040 2550 3548 Marathon 1030FDH7101 11 kv 2080 2600 136 2000 2500 131 2040 2550 134 (Medium volt. marathon) Leroy Somer LSA 54 XL75 11 kv 2080 2600 136 2040 2550 134 2040 2550 134 (Medium volt. Leroy Somer) * cos phi = 0,8 // Engine 4-Cycle Standard single stage air filter Oil drain extension & shut-off valve Closed crankcase ventilation Governor-electronic isochronous Common rail fuel injection TA-Luft optimized engine // Generator NEMA MG1, BS5000, ISO, DIN EN and IEC standards Self-ventilated Superior voltage waveform Solid state, volts-per-hertz regulator No load to full load regulation ±0,25% voltage regulation no load to full load Brushless alternator with brushless pilot exciter 4 pole, rotating fi eld Sustained short circuit current of up to 250% of the rated current for up to 10 seconds (marathon generator) Sustained short circuit current of up to 300% of the rated current for up to 10 seconds (Leroy Somer generator) Marathon low voltage generator Leroy Somer generator Oversized generator Medium voltage generator Represents standard features Represents optional features

4 / / / MTU 20V4000 DS2650 / 50 Hz / 380V - 11kV STANDARD AND OPTIONAL FEATURES, CONTINUATION // Cooling System Jacket water pump Thermostat(s) Water charge air cooling Mechanical radiator Electrical driven front-end cooler Jacket water heater // Control Panel Pre-wired control cabinet for easy application of customized controller (V1+) Island operation (V2) Automatic mains failure operation with ATS (V3a) Automatic mains failure operation incl. control of generator and mains breaker (V3b) Island parallel operation of multiple gensets (V4) Automatic mains failure operation with short (< 10s) mains parallel overlap synchronization (V5) Mains parallel operation of a single genset (V6) Mains parallel operation of multiple gensets (V7) Basler controller Deif controller Complete system metering Digital metering Engine parameters Generator Protection Functions Engine protection SAE J1939 engine ECU communications Parametrization software Multilingual capability Multiple programmable contact inputs Multiple contact outputs Event recording IP 54 front panel rating with integrated gasket Different expansion modules Remote annunciator Daytank control Generator winding temperature monitoring Generator bearing temperature monitoring Differential protection with multi-finction protection relay Modbus RTU-TCP gateway // Circuit Breaker/Power Distribution 3-pole circuit breaker 4-pole circuit breaker Manual-actuated circuit breaker Electrical-actuated circuit breaker Stand-alone solution in seperate switch box // Fuel System Flexible fuel connectors mounted to base frame Fuel filter with water separator Switchable fuel filter with water separator Seperate fuel cooler Fuel cooler integrated into cooling equipment // Starting/Charging System 24V starter Starter batteries Battery rack & cables Battery charger Represents standard features Represents optional features

5 / / / MTU 20V4000 DS2650 / 50 Hz / 380V - 11kV STANDARD AND OPTIONAL FEATURES, CONTINUATION // Mounting System Welded base frame Resilient engine and generator mounting Modular base frame design // Exhaust System Exhaust bellows with connection flange Exhaust silencer with 10 db(a) sound attenuation Exhaust silencer with 30 db(a) sound attenuation Exhaust silencer with 40 db(a) sound attenuation Y-connection-pipe Represents standard features Represents optional features

6 / / / MTU 20V4000 DS2650 / 50 Hz / 380V - 11kV WEIGHTS AND DIMENSIONS Drawing above for illustration purposes only, based an standard open power 400 Volt engine-generator set. Lengths may vary with other voltages. Do not use for installation design. See website for unit specific template drawings. System Dimensions (L x W x H) Weight (dry/less tank) Open Power Unit (OPU) 6176 x 1810 x 2332 mm 18339 kg Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific engine-generator set. SOUND DATA // Consult your local MTU Onsite Energy distributor for sound data. EMISSIONS DATA NO x + NMHC CO PM 1700 300 50 All units are in mg/nm 3 Emission levels of the engine may vary as a function of ambient temperature, barometric pressure, humidity, fuel type and quality, installation parameters, measuring instrumentation, etc. The data provided refers to ISO standard ambient conditions (25 C and 100m above sea level). The data provided are laboratory results from one engine representing this rating. The data was obtained under controlled environmental conditions with calibrated instrumentation. RATING DEFINITIONS AND CONDITIONS // Prime power ratings apply to installations where utility power is unavailable or unreliable. At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO 8528-1, ISO 3046-1, BS 5514 and AS 2789. Average load factor: 75%. // Deration factor: Altitude: Consult your local MTU Onsite Energy Power Generation distributor for altitude derations. Temperature: Consult your local MTU Onsite Energy Power Generation distributor for temperature derations. Rated power is available up to 40 C and 400m above sea level. Subject to change. 3237691 Edition 03/14 ENC 2014-07. Materials and specifications subject to change without notice. MTU Onsite Energy A Rolls-Royce Power Systems Brand www.mtuonsiteenergy.com