Installation Guidance. B-Box Pro2.5~10.0

Similar documents
Installation Guidance. B-Box Res2.5~10.0

Installation Guidance. B-BOX Res2.5~10.0

Installation Guide B-BOX Pro2.5 ~ 10.0

Installation Guide Kratos (B10L)

Installation Guidance

User Manual. B-Box 2.5~10.0. B-Box user manual. Version: 1.1. Copyright BYD Company Limited. All rights reversed.

B-Box Pro 2.5~10.0 User Manual

B-Box Pro 2.5~10.0 User Manual

B-Box Res 2.5~10.0 User Manual

B-Box Pro 13.8 User Manual

B-Box Pro 2.5~10.0 User Manual

BYD Battery-Box LV Installation Guidance

BYD Battery-Box Pro User Manual Battery-Box Pro 13.8

Quick Installation Manual Alpha ESS Battery with SMA Flexible Storage System V1.0

BYD Battery-Box LV User Manual Battery-Box L 3.5/7.0/10.5/14.0

:43 1/13 Victron & BYD B-Box

BYD Battery-Box HV User Manual Battery-Box H 5.1/6.4/7.7/9.0/10.2/11.5

ELSR RES 3.6 kwh All In One Installation Manual

Operating Manual

APPLICATION NOTE: CLOSED LOOP INTEGRATION WITH XANBUS ENABLED SCHNEIDER ELECTRIC CONEXT PRODUCTS

BYD Battery-Box LV Compatible Inverter List Battery-Box L 3.5/7.0/10.5/14.0

Lithium-Ion Phosphate Battery US2000(Version B) Product Manual

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

Lithium-Ion Phosphate Energy Storage System PowerCube-X1 Operation Manual

Installation Manual TS HV 70

ELSR RES 3.6 kwh All In One Installation Manual

User Manual. Hybrid PV Inverter. Version: 2.1

Manual. Lynx Ion 24V/180Ah Lithium Ion Batteries

BMS-LiFePower. 123SmartBMS. Instruction manual

BYD BATTERY-BOX THE BATTERY FOR ALL APPLICATIONS

User Manual. BMS123 Smart

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

Catch Eco Range : Technical Specification Sheet

SimpliPhi Power PHI Battery

Operating Manual / / REV F

Portable Solar Power Battery Pack User's Manual

APPLICATION NOTE: OPEN LOOP INTEGRATION WITH MAGNUM ENERGY

BYD BATTERY-BOX THE BATTERY FOR ALL APPLICATIONS

User Manual. SP10000 Premium

User Manual. Hybrid 4KW PV Inverter. Version: 1.2

BYD COMPANY LIMITED Address: No.3009, BYD Road, Pingshan, Shenzhen, , P.R.China

Plug Into the Current Future

CX-SERIES ADVANCED BATTERY CHARGER

Lithium Power Supply

Lithium-Ion Phosphate Battery

Lithium-Ion Phosphate Battery PowerCube-H1 Product Manual

Rechargeable Li-ion Battery US3000 Product Manual

Hub-4 / grid parallel - manual

Lithium-Ion Phosphate Battery Phantom-S Product Manual

& Operation Manual. Growatt 10000HY. Installation GR-UM-A03-A-00

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

OmniScan MX2. Getting Started Guide. Intended Use. Instruction Manual. Safety Signal Words

:34 1/15 Hub-4 / grid parallel - manual

CBC-9130 / V 30A / 24V 15A Pro. Charger. Operation manual

CX Series User s Manual

User Manual. 3kW Hybrid PV Inverter HX-3000

BYD BATTERY-BOX THE BATTERY FOR ALL APPLICATIONS

ORVALDI Solar Infini 5kW

BYD BATTERY-BOX THE BATTERY FOR ALL APPLICATIONS

Plug Into the Current Future

BYD B-Box Limited Warranty Letter

Foreword

Plug Into the Current Future

LITHIUM IRON PHOSPHATE BATTERY Multi-application - LiFePO4 Power

Magellan Utility Scale Energy Storage

Battery Fuel Gauge Specification

Quick Installa on Guide. For SK-SU.

BRAVER UPS. (Uninterruptible Power System) User s Manual

PV Master OPERATION MANUAL

LITHIUM IRON PHOSPHATE BATTERY Multi-application - LiFePO4 Power

OHY3P kW Hybrid Inverter (3-Phase) USER MANUAL V2.0

Phosphate-base Lithium-ion Battery Pack Model:LFP V 1350Ah Product Specifications Lithium Energy Solution 1/8

Lithium-Iron Phosphate Battery US2000B Product Manual

Off Grid Solar Inverter. LVS 50M User Manual

APPLICATION NOTE: OPEN LOOP INTEGRATION WITH VICTRON ENERGY

Introduction of EzManage Application

LITHIUM IRON PHOSPHATE BATTERY Multi-application - LiFePO4 Power

Operating Manual Crestwood Place, Richmond, BC, V6V 2E9, Canada discoverbattery.com

BMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

Installing a Programmed Fronius SCERT in a Managed AC Coupled system

1. Introduction OHY1P kW Hybrid Inverter USER MANUAL V2.0

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

4840 Technical specification

SimpliPhi Power PHI Battery

LITHIUM IRON PHOSPHATE BATTERY Multi-application - LiFePO4 Power

SOL-ARK 8K We guarantee it s the most effcient & affordable Multi-Mode Inverter in its class

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA. Appliances. Airconditioning Fridge. Washing machine

LITHIUM IRON PHOSPHATE BATTERY Multi-application - LiFePO4 Power

HOW TO USE H5000B TO RUN 5KW OF ENPHASE M250 OFF-GRID

Lithium Power Pack LITHIUM-ION BATTERY SYSTEM. With epro Plus Battery Monitor

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

C10325 v1.1. Thanks for your purchasing the intelligent and powerful charger.

LITHIUM IRON PHOSPHATE BATTERY Multi-application - LiFePO4 Power

123\SmartBMS. 123\SmartBMS manual V1.3. Albertronic BV The Netherlands

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

Installation - Quick Reference Guide Off-Grid Systems

Transcription:

Installation Guidance B-Box Pro2.5~10.0 Rev 2.1_Jul.2017 1/ 38

Content Safety... 4 1 Product Overview... 5 2 Cabinet terminal introduction... 6 3 Cable outlet of cabinet... 7 4 B-Plus2.5 interface and terminal introduction... 8 5 Preparations... 10 5.1 Installation notice... 10 5.2 Package information and system configuration list... 11 5.4 Installation Tools... 13 5.5 Personal protective equipment... 13 6 Installation... 14 6.1 Opening the package... 14 6.2 Disassembling the pallet & anchor bolt installation... 15 6.3 Battery installation... 16 6.4 Connection of cables... 17 7 Battery address set up... 18 7.1 ADDR switch introduction... 18 7.2 Battery address setting list (from 1~32 batteries):... 19 8 Connection to inverter... 20 8.1 CAN cable connection... 20 8.2 Power cable connection... 21 9 Starting system... 22 9.1 System activating procedures when B-Box connect to SMA Sunny Island... 22 9.2 System activating procedures when B-Box connects to GOODWE inverter... 24 9.3 System activating procedures when B-Box connects to Victron inverter... 26 9.4 System activating procedures when B-Box connects to Solax inverter... 28 10 Stopping system... 30 Appendix 1... 31 2/ 38

Appendix 2... 38 Installation Video Website:http://www.byd.com/energy/b-box-25.htm 3/ 38

Safety CAUTION: Li-ion battery (energy storage unit) inside. When assembling the system, do not intentionally make a short connection between the positive (+) and negative (-) terminals of the battery box with a metallic object. All works on the B-Box and electrical connections must be carried out by qualified personnel only. B-Box provides a safe source of electrical energy when operated as intended and as designed. Potentially hazardous circumstances such as excessive heat or electrolyte mist may occur under improper operating conditions, damage, misuse and abuse. The following safety precautions and the warning messages described in this section must be observed. If any of the following precautions are not fully understood, or if you have any questions, contact customer service for guidance. The Safety Section may not include all regulations for your region; personnel working with B-Boxes must review applicable federal, state and local regulations as well as the industry standards regarding this product. Installation personnel cannot wear watches, etc., to avoid short circuit and accidental damage. Ensure reliable grounding. Do not reverse the front panel. CAUTION: Due to the heavy weight of BYD B-Box 2.5~10.0, please use strong packaging and safety protection equipment during transportation, to ensure safety and avoid accidental damage. When increase battery, power off the battery and other power input first. 4/ 38

1 Product Overview BYD battery box products B-Box Pro 2.5~10.0 as the energy storage parts can be used in off-grid & on-grid energy storage system. Overview of B-BOX Internal view of B-BOX 5/ 38

2 Cabinet terminal introduction 1 5 3 4 6 2 8 9 10 Terminal list No. Interface Mark Function B+ / Connect to battery in cabinet, each terminal can connect 1~2 battery B- / Connect to battery in cabinet P+ / Connect to inverter P- / Connect to inverter P+ / Connect to another B-BOX or Combiner box P- / Connect to another B-BOX or Combiner box Grounded Connect the grounded cable from battery. CAN port Connect to inverter CAN port. CAN RS485 Update and maintenance Dry contact Dry contact application, output alarm info. Run led Run Indicate the Plus is running status 6/ 38

3 Cable outlet of cabinet Compare list No. Interface Mark Function CAN CAN CAN communication cable B+ B+ Positive cable from another B-BOX B+ B+ Positive cable from inverter B- B- Negative cable from inverter B- B- Negative cable from another B-BOX 7/ 38

4 B-Plus2.5 interface and terminal introduction P-:Negative terminal P+:Positive terminal GND:Grounded terminal 8/ 38

Table 1 Display and communicate interface No. Interface Mark Function SOC LED SOC Indicates State of capacity of battery RUN LED RUN Indicates the B-Plus is running status ERR LED ERR ADDR Indicates error status ALM LED Alarm Indicates alarm status RJ45 terminal RS485 Communication ports Address ADDR When parallel connection, this is for setting address. Alarm relay 1.2.3.4 Unused Test terminal B- B+ Measures battery voltage when testing. ON/OFF ON/OFF Activating of battery when no external powers add on battery. 9/ 38

5 Preparations 5.1 Installation notice a) Battery installation location should be away from heat sources and sparks should be avoided. The safety distance should be more than 0.5m. b) Battery connection cables should be as short as possible, to prevent excessive line pressure drop. c) Batteries with different capacity, different P/N or different manufacturers are not allowed for connection. d) Before conducting the battery, the battery positive and negative poles need to be carefully checked as well to ensure correct installation. e) The mounting floor should be flat. 10/ 38

向上易碎物品怕雨堆码层数极限 5.2 Package information and system configuration list The cabinet and battery are packaged separately with cartons, the components are supplied with the cabinet or battery package. Before installation, installers should read the system configuration list. No. Item Description Qty Purpose Picture 1 Anchor bolt 4 To allow distance from cabinet to ground. 2 User Manual 1 System information, operating instructions and warranty items. \ 3 Installation Manual 1 System installation guidance \ No. Item Description Qty Purpose Picture 1 Positive cable 1 Battery P+ connection 2 Negative cable 1 Battery P- connection LITHIUM ION BATTERIES UN3480 4G/Y50/S/16 n u CN/XXXXXX PI:XXX 9 9 3 GND 1 Connection of battery grounded terminal 4 Communication 1 Battery RS485 port connection cable 11/ 38

5.3 Configuration list Type B-BOX 2.5 B-BOX 5.0 B-BOX 7.5 B-BOX 10.0 B-Box cabinet 1 1 1 1 B-Plus2.5 1 2 3 4 User manual 1 1 1 1 Positive cable 1 2 3 4 Negative cable 1 2 3 4 Communicate cable 1 2 3 4 Grounded cable 1 2 3 4 12/ 38

5.4 Installation Tools Cross screwdriver M3~M10 Flat tip screwdriver M3~M6 Sockets spanner Diagonal cutters Adjustable wrench Knife 5.5 Personal protective equipment 13/ 38

9 向上易碎物品怕雨堆码层数极限 6 Installation 6.1 Opening the package Tools: Knife LITHIUM ION BATTERIES UN3480 4G/Y50/S/16 n u CN/XXXXXX PI:XXX 9 14/ 38

6.2 Disassembling the pallet & anchor bolt installation Tools: Adjustable spanner fixed torque: 10±1 Nm Lay down the cabinet, put some protections on the ground to avoid sratches. Take away the pallet and four screws that installed on the root of the pallet. Install the 4pcs anchor bolt into the four hole in bottom of cabinet. 15/ 38

6.3 Battery installation Tools: Cross screwdriver Move the cabinet to the installation place, prepare to install battery. Open the door, take away the screws of the battery storey and front panel. Push the battery into battery storey from the bottom, one cabinet can install maximum 4pcs batteries Fix all batteries with screws. Finish battery installation. 16/ 38

6.4 Connection of cables Tools: Cross screwdriver Remove the left side panel. Install the cables, install the positive cable to B+ DC BUS, install the negative to B- DC BUS. Tie the cable tight and pass the cables through the holes next to the batteries. 17/ 38

7 Battery address set up 7.1 ADDR switch introduction Function: For communication between battery and BMU. BMU will communicate with external equipment by using CAN communication. Each DIP switch definition: There are 6 bit switches, keep the switch on down side means 0, turn up the switch to ON means 1. Address: 000000 Address:100000 For example: when two battery in using, ADDR setting: No.1 battery address: 100000 No.2 battery address: 010000 For address setting, please refer to the configuration list in next page. Note: Make sure of the highest address of B-Plus2.5 connect to BMU. 18/ 38

7.2 Battery address setting list (from 1~32 batteries): Battery No. Address Battery No. Address 1 100000 17 100010 2 010000 18 010010 3 110000 19 110010 4 001000 20 001010 5 101000 21 101010 6 011000 22 011010 7 111000 23 111010 8 000100 24 000110 9 100100 25 100110 10 010100 26 010110 11 110100 27 110110 12 001100 28 001110 13 101100 29 101110 14 011100 30 011110 15 111100 31 111110 16 000010 32 000001 19/ 38

8 Connection to inverter 8.1 CAN cable connection RJ45 PIN define B-BOX SMA GOODWE SOLAX VICTRON CAN H 4 4 4 1 7 CAN L 5 5 5 2 8 When installers attempt CAN ports connections between B-Box and inverter, please refer to below drawing. 20/ 38

8.2 Power cable connection Tools: Cross screwdriver, fixed torque: 25±2.5Nm Remark: Each rack s negative cables should be fastened with the belt, and the cable length between each cabinet and inverter shall be the same. Be careful not to reverse connection. 21/ 38

9 Starting system Notice: Before activating the system, please make sure that you: Confirm all the batteries are powered OFF. Confirm all power cables are connected correctly and securely. Confirm all communication cables are connected correctly and securely. 9.1 System activating procedures when B-Box connect to SMA Sunny Island ⑴ Start B-Box Activate all of the B-Plus 2.5 Tips: Pressing ON/OFF button one second will start the B-Plus, according to the number of inverters in the following table, activate the batteries as fast as possible within 8 seconds Inverter:1~2PCS Inverter:3~4PCS Inverter:5~7PCS Inverter:8~9PCS The amount of battery 1 2 3 4 Once start, the LED lights of B-Plus 2.5 will flash in various forms according to the battery status, as below: LED status when normal start Item LED Status 1 Run Green 2 SOC More than one is green. Slow blink is charging and fast blink is discharging. The merry-go-round means no communication. 3 ERROR OFF 4 Alarm OFF 22/ 38

Status(display interval 2S) Definition LED(BMU) Blinks 1 time Inverter not connected Blinks 2 time Blinks 3 time Blinks 4 time Battery not connected Battery disconnected Battery failure Remark: Slow blink: indicator light is on and off every 1s (0.5Hz). Fast blink: indicator light is on and off every 0.25s (2HZ) SOC status and indicate ⑵ Switching on the Sunny Island; Procedure: Item Status Indicate 1 Four lights are all normally on Capacity is 100%-75% (including) 2 The last three lights are normally on Capacity is 74%-50% (including) 3 The last two lights are normally on Capacity is 49%-25% (including) 4 The last one light is normally on Capacity is 24%-1% (including) For systems with one Sunny Island, press the "On" button on the Sunny Island. the inverter LED on each Sunny Island inverter is glowing orange and the Sunny Island inverters are in standby. ⑶ Start the inverter; Procedure: Press the start-stop button on the Sunny Island and hold it until an acoustic signal sounds. Or press and hold the button on the Sunny Remote Control until an acoustic signal sounds. ⑷ Set up battery parameters on SRC of inverter; Please refer to the Battery Parameter setting table in Appendix1. The inverter LED on each Sunny Island is glowing green. Remark: If the battery capacity is greater than or equal to 200AH, according to the B-Box10.0 parameter settings ⑸ System is running. 23/ 38

9.2 System activating procedures when B-Box connects to GOODWE inverter ⑴ Download the APP on user s cell phone and open the home page; ⑵ Start B-Box; Press the ON/OFF button on front panel of B-Plus2.5; Tips: Press one second will start the B-Plus; Once start, the LED lights of B-Plus 2.5 will flash in various forms according to the battery status, as below: LED status when normal start Item LED Status 1 Run Green 2 SOC More than one is green. Slow blink is charging and Fast blink is discharging. The merry-go-round means no communication. 3 ERROR OFF 4 Alarm OFF Status(display interval 2S) Definition LED(BMU) Blinks 1 time Inverter not connected Blinks 2 time Blinks 3 time Blinks 4 time Battery not connected Battery disconnect Battery failure Remark: Slow blink: indicator light is on and off every 1s (0.5Hz). Fast blink: indicator light is on and off every 0.25s (2HZ) 24/ 38

SOC status and indicate Item Status Indicate 1 Four lights are all normally on Capacity is 100%-75% (including) 2 The last three lights are normally on Capacity is 74%-50% (including) 3 The last two lights are normally on Capacity is 49%-25% (including) 4 The last one light is normally on Capacity is 24%-1% (including) ⑶ Go to the home page of the APP, enter into the Battery Settings page, select BYD B-BOX battery, then select NEXT until the last page, finally select Start. Remark: If the installed capacity is greater than or equal to 10.0KWh, pls choose the product model as "BYD B-BOX 10" in the App ⑷ System is running. 25/ 38

9.3 System activating procedures when B-Box connects to Victron inverter ⑴ Start inverter; ⑵ Set the battery DOD at a minimum of 5% on-grid; Set the battery DOD at a minimum of 10% off-grid. ⑶ Start B-BOX; Press the ON/OFF button on front panel of B-Plus 2.5; Tips: Press ON/OFF button one second will start B-Plus, activate the batteries as fast as possible within 8 seconds according to the number of inverters in the following table. Inverter:1~2PCS Inverter:3~4PCS Inverter:5~7PCS Inverter:8~9PCS The amount of battery 1 2 3 4 Once start, the LED lights of B-Plus 2.5 will flash in various forms according battery status, as below: LED status when normal start Item LED Status 1 Run Green 2 SOC More than one is green. Slow blink is charging and fast blink is discharging. The ferry-go-round means no communication. 3 ERROR OFF 4 Alarm OFF Status(display interval 2S) Definition LED(BMU) Blinks 1 time Inverter not connected Blinks 2 time Blinks 3 time Blinks 4 time Battery not connected Battery disconnect Battery failure 26/ 38

Remark: Slow blink: indicator light is on and off every 1s (0.5Hz). Fast blink: indicator light is on and off every 0.25s (2HZ) SOC status and indicate Item Status Indicate 1 Four lights are all normally on Capacity is 100%-75% (including) 2 The last three lights are normally on Capacity is 74%-50% (including) 3 The last two lights are normally on Capacity is 49%-25% (including) 4 The last one light is normally on Capacity is 24%-1% (including) ⑷ System is running. 27/ 38

9.4 System activating procedures when B-Box connects to Solax inverter ⑴ Start B-Box Press the ON/OFF button on front panel of B-Plus 2.5; Tips: Press one second will start B-Plus; Once start, the LED lights of B-Plus 2.5 will flash in various forms according to battery status, as below: LED status when normal start Item LED Status 1 Run Green 2 SOC More than one is green. Slow blink is charging and fast blink is discharging. The ferry-go-round means no communication. 3 ERROR OFF 4 Alarm OFF Status(display interval 2S) Definition LED(BMU) Blinks 1 time Inverter not connected Blinks 2 time Blinks 3 time Blinks 4 time Battery not connected Battery disconnect Battery failure Remark: Slow blink: indicator light is on and off every 1s (0.5Hz). Fast blink: indicator light is on and off every 0.25s (2HZ) 28/ 38

SOC status and indicate Item Status Indicate 1 Four lights are all normally on Capacity is 100%-75% (including) 2 The last three lights are normally on Capacity is 74%-50% (including) 3 The last two lights are normally on Capacity is 49%-25% (including) 4 The last one light is normally on Capacity is 24%-1% (including) (2) Activate inverter; (3) Go to the home page of the APP, and enter into Charger Settings page, select Battery Type Lithium, then select Min Capacity setting 20%, finally select Battery awaken. Choose YES to complete the battery parameter settings. (4) System is running; 29/ 38

10 Stopping system Note: 1. Before stopping the system, shut down the system in the following orders: AC Load=>PV=>Inverter=>Battery 2. After stopping the system, please ensure that you: Confirm all the batteries are powered OFF. Check all the LEDs are OFF. Check that the inverter has powered off. 30/ 38

Appendix 1 SMA charger min capacity Parameter setup for B-BOX2.5 Charging the battery - usage through battery backup system without increased self-consumption Setup value 003.07Batt Typ Li Lon_Ext-BMS 003.10Batt Cpynom 50 262.01ProtResSOC 3 262.02BatResSOC 10 Charging the battery - usage through battery backup system with increased self-consumption Setup value 003.07Batt Typ Li Lon_Ext-BMS 003.10Batt Cpynom 50 261.01SlfCsmplncEna Enable 261.03Saisonenable Yes 262.01ProtResSOC 3 262.02BatResSOC 6 262.03BUResSOC 0 262.04PVResSOC 8 262.05MinSlfCsmpSOC 75 Charging the battery - usage through system for increased self-consumption without a battery backup grid Setup value 003.07Batt Typ Li Lon_Ext-BMS 003.10Batt Cpynom 50 261.01SlfCsmplncEna Enable 261.03Saisonenable Yes 262.01ProtResSOC 3 262.02BatResSOC 6 31/ 38

262.04PVResSOC 8 262.03BUResSOC 0 262.05MinSlfCsmpSOC 75 Parameter setup for B-BOX 5.0 Charging the battery - usage through battery backup system without increased self-consumption Setup value 003.07Batt Typ Li Lon_Ext-BMS 003.10Batt Cpynom 100 262.01ProtResSOC 3 262.02BatResSOC 7 Charging the battery - usage through battery backup system with increased self-consumption Setup value 003.07Batt Typ Li Lon_Ext-BMS 003.10Batt Cpynom 100 261.01SlfCsmplncEna Enable 261.03Saisonenable Yes 262.01ProtResSOC 3 262.02BatResSOC 4 262.03BUResSOC 0 262.04PVResSOC 6 262.05MinSlfCsmpSOC 80 Charging the battery - usage through system for increased self-consumption without a battery backup grid Setup value 003.07Batt Typ Li Lon_Ext-BMS 003.10Batt Cpynom 100 261.01SlfCsmplncEna Enable 261.03Saisonenable Yes 262.01ProtResSOC 3 262.02BatResSOC 4 32/ 38

262.04PVResSOC 6 262.03BUResSOC 0 262.05MinSlfCsmpSOC 80 Parameter setup for B-BOX7.5 Charging the battery - usage through battery backup system without increased self-consumption Setup value 003.07Batt Typ Li Lon_Ext-BMS 003.10Batt Cpynom 150 262.01ProtResSOC 3 262.02BatResSOC 6 Charging the battery - usage through battery backup system with increased self-consumption Setup value 003.07Batt Typ Li Lon_Ext-BMS 003.10Batt Cpynom 150 261.01SlfCsmplncEna Enable 261.03Saisonenable Yes 262.01ProtResSOC 3 262.02BatResSOC 4 262.03BUResSOC 0 262.04PVResSOC 4 262.05MinSlfCsmpSOC 85 Charging the battery - usage through system for increased self-consumption without a battery backup grid Setup value 003.07Batt Typ Li Lon_Ext-BMS 003.10Batt Cpynom 150 261.01SlfCsmplncEna Enable 261.03Saisonenable Yes 262.01ProtResSOC 3 262.02BatResSOC 4 33/ 38

262.04PVResSOC 4 262.03BUResSOC 0 262.05MinSlfCsmpSOC 85 Parameter setup for B-BOX10.0 Charging the battery - usage through battery backup system without increased self-consumption Setup value 003.07Batt Typ Li Lon_Ext-BMS 003.10Batt Cpynom 200 262.01ProtResSOC 3 262.02BatResSOC 6 Charging the battery - usage through battery backup system with increased self-consumption Setup value 003.07Batt Typ Li Lon_Ext-BMS 003.10Batt Cpynom 200 261.01SlfCsmplncEna Enable 261.03Saisonenable Yes 262.01ProtResSOC 3 262.02BatResSOC 4 262.03BUResSOC 0 262.04PVResSOC 4 262.05MinSlfCsmpSOC 85 Charging the battery - usage through system for increased self-consumption without a battery backup grid Setup value 003.07Batt Typ Li Lon_Ext-BMS 003.10Batt Cpynom 200 261.01SlfCsmplncEna Enable 261.03Saisonenable Yes 262.01ProtResSOC 3 262.02BatResSOC 4 34/ 38

262.04PVResSOC 4 262.03BUResSOC 0 262.05MinSlfCsmpSOC 85 Parameter setup for B-BOX in off-grid Protection for the Battery Recommended Value 223.05 BatPro1Soc 12% 223.06 BatPro2Soc 12% 223.07 BatPro3Soc 3% Gen Autostart Control Recommended Value 235.03 GnSocTm1Str 17% 235.04 GnSocTm1Stp 35% 35/ 38

Parameter setup for B-BOX7.5 Three-phase Charging the battery - usage through battery backup system without increased self-consumption Setup value 003.07Batt Typ Li Lon_Ext-BMS 003.10Batt Cpynom 150 262.01ProtResSOC 3 262.02BatResSOC 10 Charging the battery - usage through battery backup system with increased self-consumption Setup value 003.07Batt Typ Li Lon_Ext-BMS 003.10Batt Cpynom 150 261.01SlfCsmplncEna Enable 261.03Saisonenable Yes 262.01ProtResSOC 3 262.02BatResSOC 6 262.03BUResSOC 0 262.04PVResSOC 8 262.05MinSlfCsmpSOC 75 Charging the battery - usage through system for increased self-consumption without a battery backup grid Setup value 003.07Batt Typ Li Lon_Ext-BMS 003.10Batt Cpynom 150 261.01SlfCsmplncEna Enable 261.03Saisonenable Yes 262.01ProtResSOC 3 262.02BatResSOC 6 262.04PVResSOC 8 262.03BUResSOC 0 262.05MinSlfCsmpSOC 75 36/ 38

Parameter setup for B-BOX10.0 Charging the battery - usage through battery backup system without increased self-consumption Setup value 003.07Batt Typ Li Lon_Ext-BMS 003.10Batt Cpynom 200 262.01ProtResSOC 3 262.02BatResSOC 10 Charging the battery - usage through battery backup system with increased self-consumption Setup value 003.07Batt Typ Li Lon_Ext-BMS 003.10Batt Cpynom 200 261.01SlfCsmplncEna Enable 261.03Saisonenable Yes 262.01ProtResSOC 3 262.02BatResSOC 6 262.03BUResSOC 0 262.04PVResSOC 8 262.05MinSlfCsmpSOC 75 Charging the battery - usage through system for increased self-consumption without a battery backup grid Setup value 003.07Batt Typ Li Lon_Ext-BMS 003.10Batt Cpynom 200 261.01SlfCsmplncEna Enable 261.03Saisonenable Yes 262.01ProtResSOC 3 262.02BatResSOC 6 262.04PVResSOC 8 262.03BUResSOC 0 262.05MinSlfCsmpSOC 75 37/ 38

Appendix 2 Solax charger min capacity Product Min capacity B-BOX 2.5 20% B-BOX 5.0 15% B-BOX 7.5 15% B-BOX 10.0 10% B-BOX 12.8 10% 38/ 38