Vacuum grippers VACUUM PRODUCTS INNOVATORS IN VACUUM TECHNOLOGY CATALOG VERSION 5.0 VACUUM A RESOURCE FOR EVERYONE www.piab.com Accessories Suction cups Vacuum pumps PVA
VACUUM SWITCHES, INDUCTIVE UNIVERSAL The adjustable vacuum switches are actuated at a set vacuum level and set by a knob. The pre-set vacuum switches are actuated at a preset vacuum level, non-adjustable. Converts a vacuum signal to an electric signal. Vacuum-actuated membrane linked to a proximity-inductive universal switch. The output functions PNP NO, PNP NC, NPN NO and NPN NC are available in the vacuum switch. The switch must be connected in series with the load. TECHNICAL DATA Unit Value Material PBTP, PVC, PA SS NBR, POM Al, CuZn Temperature range F -13 176 Weight oz 1.76-2.29 Connection Vacuum M5 Hysteresis -inhg 0.60 Cable 2 x 0.14 mm 2 x 6.56 ft Supply voltage V DC 24 (5 36) Safety classification IP67 Current Output, max ma 200 Voltage drop, max V 4.6 TECHNICAL DATA, SPECIFIC Unit Value 31.16.064 31.16.089 31.16.090 31.16.091 Signal range -inhg 3.0-28.0 3.0±0.3 9.0±0.9 21.0±1.5 Supplement 1 PNP NO = Normally Open, Positive logic. As the switch is activated, the gate at the feed current (+) closes and contact is established. PNP NC = Normally Closed, Positive logic. As the switch is activated, the gate at the feed current (+) opens and contact is interrupted. NPN NO = Normally Open, Negative logic. As the switch is activated, the gate at ground (-) closes and contact is established. NPN NC = Normally Closed, Negative logic. As the switch is activated, the gate at ground (-) opens and contact is interrupted. Note: NO, Normally Open, in electrical circuits corresponds to an open circuit breaker, which means that, if the gate is open, no current can pass through. NO, Normally Open, in pneumatic circuits corresponds to an open valve, which means that, if the valve is open, compressed air passes through. Supplement 2 The adjustable vacuum switch, inductive universal, must be connected in series with the load! 398 Specifications subject to change without notice.
ORDERING INFORMATION A Vacuum switch, inductive universal, adjustable with knob 31.16.064 B Vacuum switch, inductive universal, pre-set (Signal range 3.0 -inhg) 31.16.089 B Vacuum switch, inductive universal, pre-set (Signal range 9.0 -inhg) 31.16.090 B Vacuum switch, inductive universal, pre-set (Signal range 21.0 -inhg) 31.16.091 A B Accessories ORDERING INFORMATION, ACCESSORIES Connection set for vacuum switch 01.00.488 Contents: Barrel nipple G1/8 M5 long, hose connector 4/2 M5. Material: Nickel-plated brass, SS, PA66, NBR, PA6. Fits: All pre-set and adjustable vacuum switches. Specifications subject to change without notice. 399
VACUUM SWITCHES, ELECTRO-MECHANICAL The adjustable vacuum switches are actuated at a set vacuum level and set by a knob. The pre-set vacuum switches are actuated at a preset vacuum level, non-adjustable. Converts a vacuum signal to an electric signal. Vacuum-actuated membrane linked to an electromechanical switch. Output function NO or NC. TECHNICAL DATA Unit Value Material PBTP, PVC, PA, SS, NBR, POM, Al, CuZn Temperature range F -4 176 Weight oz 1.76-2.19 Connection vacuum M5 Function output NO/NC Hysteresis -inhg 3.0 Cable 3 x 0.75 mm 2 x 1.64 ft Voltage supply, max. V AC 250 Safety classification IP67 Current output, max A 5 TECHNICAL DATA, SPECIFIC Unit Value 31.16.068 31.16.061 31.16.095 31.16.096 Signal range -inhg 4.0 28.0 4.0-28.0 7.5±1.5 19.0±1.5 Note: NO, Normally Open, in electrical circuits corresponds to an open circuit breaker, which means that, if the gate is open, no current can pass through. NO, Normally Open,in pneumatic circuits corresponds to an open valve, which means that, if the valve is open, compressed air passes through. 400 Specifications subject to change without notice.
ORDERING INFORMATION A Vacuum switch, electro-mechanical, adjustable with knob 31.16.068 B Vacuum switch, electro-mechanical, adjustable with screw 31.16.061 C Vacuum switch, electro-mechanical, pre-set (Signal range 7.5 -inhg) 31.16.095 C Vacuum switch, electro-mechanical, pre-set (Signal range 19.0 -inhg) 31.16.096 Accessories A B ORDERING INFORMATION, ACCESSORIES C Connection set for vacuum switch 01.00.488 Contents: Barrel nipple G1/8 M5 long, hose connector 4/2 M5. Material: Nickel-plated brass, SS, PA66, NBR, PA6. Fits: All pre-set and adjustable vacuum switches. Specifications subject to change without notice. 401
VACUUM SWITCHES, PNEUMATIC The adjustable vacuum switches are actuated at a set vacuum level and set by a knob. The pre-set vacuum switches are actuated at a preset vacuum level, non-adjustable. Converts a vacuum signal to a pneumatic signal. Vacuum-actuated membrane linked to a pneumatic switch. Output function NO or NC. TECHNICAL DATA Unit Value Pressure range psi 22-116 Material PA, SS, NBR, POM, Al, CuZn Temperature range F 14-140 Weight oz 1.38 Connection vacuum M5 TECHNICAL DATA, SPECIFIC Unit Value 31.16.069 31.16.062 31.16.070 31.16.063 31.16.083 31.16.084 31.16.085 31.16.087 31.16.088 Signal range -inhg 3.0-28.0 4.5-28.0 3.0±0.60 7.5±1.2 19.0±2.4 9.0±1.5 21.0±3.0 Function NO NC NO NC output Hysteresis -inhg 0.90 3.50 0.90 3.50 NO, Normally Open, in pneumatic circuits corresponds to an open valve, which means that, if the valve is open, compressed air passes through. 402 Specifications subject to change without notice.
ORDERING INFORMATION A Vacuum switch, pneumatic, adjustable with screw (NO) 31.16.062 A Vacuum switch, pneumatic, adjustable with screw (NC) 31.16.063 B Vacuum switch, pneumatic, adjustable with knob (NO) 31.16.069 B Vacuum switch, pneumatic, adjustable with knob (NC) 31.16.070 C Vacuum switch, pneumatic, preset (NO 3.0 -inhg) 31.16.083 C Vacuum switch, pneumatic, preset (NO 7.5 -inhg) 31.16.084 C Vacuum switch, pneumatic, preset (NC 19.0 -inhg) 31.16.085 C Vacuum switch, pneumatic, preset (NC 9.0 -inhg) 31.16.087 C Vacuum switch, pneumatic, preset (NC 21.0 -inhg) 31.16.088 Accessories A B ORDERING INFORMATION, ACCESSORIES C Connection set for vacuum switch 01.00.488 Contents: Barrel nipple G1/8 M5 long, hose connector 4/2 M5. Material: Nickel-plated brass, SS, PA66, NBR, PA6. Fits: All pre-set and adjustable vacuum switches. Specifications subject to change without notice. 403
VACUUM SWITCHES, ELECTRIC EVS EVS 54 WITH Calibrated Adjustment Dial EVS 100 NEMA 4X EVS 54 EVS 100 Range: 0 to 30 -inhg. SPDT Switch, wired normally open or normally closed. CE marked (conforms with Low Voltage Directive) UL 508 Listed; CSA Certified, C22.2 No. 14 Electrical Rating: 15 amps 125/250 VAC resistive. TECHNICAL DATA Model Enclosure Pressure Connection EVS 54 Calibrated adjustment dial (dial divisions 2 -inhg.) Buna N diaphragm sensor EVS 100 Internal setpoint reference scale. Phosphor bronze bellows sensor EVS 100 has optional indicator light. Lexan Dust Cover NEMA 4X; IP65, die cast aluminum with epoxy powder coated. 1/4" NPTM, aluminum 1/4" NPTF, nickel plated brass Proof Pressure Dead Band Mounting 50 PSIG 1.5 to 3.5 -inhg. Holes for surface mounting 30 -inhg. 1 to 2 -inhg. Mounting: surface mount with two screws or mount by pressure connection. OPTIONAL MICROSWITCHES 6259-217 5 amp 125/250 VAC resistive switch. Close band differential for EVS 54 (range.375 -.875 -inhg) & EVS 100 (range.25 -.50 -inhg.) 6259-529 10 amp 125/250 VAC resistive DPDT switch. Wider deadband for EVS 100 only. Deadband range is 2.0-4.0 -inhg. 6259-550 15 amp 480 VAC resistive switch. Adjustable deadbandfor EVS 100 only. Deadband range is 2.5-10.0 -inhg.(mod. #1519) EVS 54 EVS 100 404 Specifications subject to change without notice.