How to perform temperature profiling in hazardous environments

Similar documents
Hydroprocessing Reactor Control Key to Long & Optimized Runs with Advanced Temperature Measurement Systems

CHALLENGES IN DESIGNING SYNTHESIS CONVERTERS FOR VERY LARGE METHANOL PRODUCTION CAPACITY

On-Line Process Analyzers: Potential Uses and Applications

Co-Processing of Green Crude in Existing Petroleum Refineries. Algae Biomass Summit 1 October

Miniature multipoint thermocouple Model TC96-M

Rosemount Multipoint Thermocouple and RTD Profiling Sensors

HOW OIL REFINERIES WORK

SCANFINING TECHNOLOGY: A PROVEN OPTION FOR PRODUCING ULTRA-LOW SULFUR CLEAN GASOLINE

Usage Issues and Fischer-Tropsch Commercialization

Conversion Processes 1. THERMAL PROCESSES 2. CATALYTIC PROCESSES

COMBUSTION EFFICIENCY

CONTENTS 1 INTRODUCTION SUMMARY 2-1 TECHNICAL ASPECTS 2-1 ECONOMIC ASPECTS 2-2

HOW OIL REFINERIES WORK

SULFIDING SOLUTIONS. Why Sulfide?

Article on Sheath materials, Thermowells, Fittings, and Terminations

C C A. Combustion Components Associates, Inc.

Petroleum Refining Fourth Year Dr.Aysar T. Jarullah

Thermocouple insert for Temperatur Sensor omniset- TPC 100

PILOT PLANT DESIGN, INSTALLATION & OPERATION Training Duration 5 days

TSHR 7000 series TN-TS-TX analyzer

Onboard Plasmatron Generation of Hydrogen Rich Gas for Diesel Engine Exhaust Aftertreatment and Other Applications.

AN INTRODUCTION TO PETROLEUM REFINING AND THE PRODUCTION

Reliable. Safe. Cost Effective. Electronic differential pressure for level measurement with metal or ceramic sensors

MECHANISM OF NOx CONTROL

Preface... xii. 1. Refinery Distillation... 1

IHS CHEMICAL PEP Report 29J. Steam Cracking of Crude Oil. Steam Cracking of Crude Oil. PEP Report 29J. Gajendra Khare Principal Analyst

Programmable Safety Systems for Burner Management on Gas Turbines.

SPECIFY THE RIGHT HOT OIL PUMP FOR YOUR APPLICATION

HOW OIL REFINERIES WORK

L.A. Maritime describes the operation of Aquametro Fuel-Switching Devices

Challenges and Opportunities in Managing CO 2 in Petroleum Refining

Results Certified by Core Labs for Conoco Canada Ltd. Executive summary. Introduction

Thermowell for temperature sensors omnigrad M TW 11

Internal Combustion Engines

State of the Art (SOTA) Manual for Internal Combustion Engines

PCE154. Refinery Process and Products. H.H. Sheikh Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

The Prime Glass DeNOx solutions in the present scenario of the glass industry NOx containment technologies

Achieving Ultra-Low Sulfur Diesel with IsoTherming Technology

Fluid Catalytic Cracking Unit - FCCU

ABB MEASUREMENT & ANALYTICS. Predictive Emission Monitoring Systems The new approach for monitoring emissions from industry

Module 2:Genesis and Mechanism of Formation of Engine Emissions Lecture 3: Introduction to Pollutant Formation POLLUTANT FORMATION

EXAMINATION OF THE AMMONIA DOSE INFLUENCE ON NITRIC OXIDES TRANSFORMATIONS INTO COMBINED OXIDE-PLATINUM SCR CATALYST

DPF Troubleshooting - Diagnosis and Remedy

Infrared Thermography to Detect Refractory Damage in a Fluid Catalytic Cracking Unit

Pyrophoric Ignition Hazards in Typical Refinery Operations

Diaphragm. Seal Solutions. Process Industry

Petroleum Refining-Production Planning, Scheduling and Yield Optimization

Monitor Chlorine in Crude at Sub-ppm Levels

Thermowell for temperature sensors omnigrad M TW 13

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

THE OIL & GAS SUPPLY CHAIN: FROM THE GROUND TO THE PUMP ON REFINING

OPPORTUNITY CRUDES: TO PROCESS OR NOT TO PROCESS?

Claus unit Tail gas treatment catalysts

Refinery / Petrochemical. Integration. Gildas Rolland

VPPC Terry Hosking, V.P. of Engineering SBE Inc.

Unit 1. Naphtha Catalytic Reforming. Assistant lecturers Belinskaya Nataliya Sergeevna Kirgina Maria Vladimirovna

Process Industry. Diaphragm Seal Solutions

Development of a Non-Catalytic JP-8 Reformer

ESTIMATION OF NO X CONVERSION INTO OXIDE, PLATINUM AND COMBINED OXIDE PLATINUM SCR CATALYST

The Role of the Merox Process in the Era of Ultra Low Sulfur Transportation Fuels. 5 th EMEA Catalyst Technology Conference 3 & 4 March 2004

Corrosion Control for Control Rooms & Process Control Environments AIRBORNE PARTICULATE AND GASEOUS CONTAMINANT SOLUTIONS

Conductivity Measuring Cells ConduMax W CLS 19

Magnetic Level Gauges

Reformate Desulfurization for Logistic

Crude Distillation Chapter 4

CHEMKIN-PRO Exhaust Aftertreatment for Gas Turbine Combustors

Combustion Equipment. Combustion equipment for. Solid fuels Liquid fuels Gaseous fuels

Innovative & Cost-Effective Technology for Producing Low Sulfur Diesel

BULLETIN August 2009 PERMASEAL PLUG VALVE. ISO 9001:2008 Certified QMS. SMG Valves A Unit of Southern Manufacturing Group, Inc.

INFLUENCE OF THE NUMBER OF NOZZLE HOLES ON THE UNBURNED FUEL IN DIESEL ENGINE

Thermocouple Model TC10-E, for additional thermowell

A CLOSER LOOK AT BATTERIES by John Wiles. Perspectives on PV

in Preventing Explosions within Fired Equipment: The Role of Basic Design Data Robert Wasileski A Case Study Process Safety & Loss Prevention Engineer

Explosion proof RTD assembly T15

Converting low quality gas into a valuable power source

Growing the World s Fuels

Distillation process of Crude oil

Modernizing a Vintage Cat Cracker. Don Leigh HFC Rahul Pillai KBR Steve Tragesser KBR

Steam cracking - furnaces

TEMPERATURE CHANGE OF A TYPE IV CYLINDER DURING HYDROGEN FUELING PROCESS

Chris Santner; Sr Director, Catalytic Cracking Technology. Coking and CatCracking Conference, New Delhi, October 2013

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Magnetic Level Gauges

Sarasota FD900 Sarasota ID900 Sarasota PD900 Gas Density Meters for Gas Metering and Control

UOP/EMRE Alliance for High Quality Lube and Diesel Production Technology

breakthrough versatility

RTD Insert for Temperature Sensor omniset- TPR100

Combustion Control Problem Solution Combustion Process

Steam reforming. The product is then ready to be used in refinery applications or for synthesis of ammonia or methanol. APPLICATION REPORT CLOSEOPEN

Tourniket. The all round revolving door. Door Systems

For Applications Demanding Precision and Efficiency, FloMax Nozzles Outperform All Others

Measurement made easy. Predictive Emission Monitoring Systems The new approach for monitoring emissions from industry

Omnigrad S -TC65. Technical Information

for biodiesel applications

EMISSION CONTROL EMISSION CONTROLS

APC Implementation Case Study Vacuum Gasoil Cloud Point Model Predictive Controller 1

Maximizing Refinery Margins by Petrochemical Integration

LC-FINING Options for Heavy Oil Upgrading

1- REFINERY OF POINTE - NOIRE CATALYTIC REFORMING UNIT

The revolving door for intensive traffic flow

Transcription:

How to perform temperature profiling in hazardous environments Instrumentation is available to perform temperature profiling in oil & gas, refining and petrochemical applications, but care must be taken during installation and use By Keith Riley, Pressure+Temperature Product Marketing Manager, Endress+Hauser and Tim Schrock, Americas Area Manager, Endress+Hauser Measuring temperature across a process unit such as a furnace, desalter, hydrofiner, fixed-bed reactor or hydrocracker in refineries, or similar process units in chemical plants leads to improved process control, increased catalyst life, more efficient production, fewer process upsets, and decreased emissions. Known as temperature profiling, this technique allows acquisition of temperature data from multiple sensors, then transmits the data to an automation system where control and monitoring software analyze the data and take action. This article covers the sensing devices used to acquire temperature profile data. Although the sensing equipment shown in the examples is from Endress+Hauser, similar equipment may be available from other instrumentation suppliers. Profiling a hydrofiner A hydrofiner is a typical application for temperature profiling. New environmental standards for low sulfur fuels are driving the need for temperature profiling in the refining industry. This set of new regulations requires plants to reduce air pollution emissions, particularly NOx, leading to equipment retrofits and upgrades. For example, the sulfur content in mineral oil products has to be limited, and this is typically achieved by catalytic desulfurization in a hydrofiner. Heated to 572-752 F (300-400 C) and raised to a pressure of 362-870 psi (2.5 to 6 MPa), the oil is mixed with hydrogen and reacts with the catalyst. The sulfur molecular connection is then converted to H2S and hydrogen carbides. One of the issues with this process is performing temperature profile monitoring at the different catalyst layers of a hydrofiner (Figure 1). Only a limited number of access points are available in a hydrofiner, so multiple sensors have to be inserted at each access point across the layers.

Figure 1: Temperature profiling at the different catalyst layers in a hydrofiner. Note the multiple sensors (top left) inserted at each access point. One way is to insert a special sensor array with multiple sensors, all connecting to a single transmitter. The Endress+Hauser Octoplus (seen in the top left corner of Figure 1) has multiple sensors as needed based on the application; individual thermocouples mounted in a single nozzle. The unit s tentacles can be positioned within the reactor as needed to monitor the layer. Using data from multiple sensors, the control and monitoring software can construct a 3D image of the catalyst layer. Temperature sensing elements can be replaced individually to minimize maintenance. The sensing elements are encased in a guiding tube that remains in the reactor. This allows a faulty insert to be easily exchanged for a new one (Figure 2). 2 Figure 2: Individual temperature sensors can be quickly replaced.

Temperature profiling with a sensor array is also useful in fixed-bed reactors. Due to the solid state of the catalyst, it may not be possible to achieve a homogeneous reaction mixture. Formation of hot spots and cold spots may occur, and coke formation can quickly lead to deactivation of the catalyst. With multiple measuring points per process connection, sensors can be freely positioned in the reactor to detect problems. As a result, operations can quickly become aware of a degrading process situation and take appropriate action. Sensors are routed to a process transmitter or terminal block that can accept multiple sensors and then output 4-20 ma signals or thermocouple signals to the control system. Either the terminal block or the transmitter are typically housed in an enclosure (Figure 3). Figure 3: An enclosure contains either a terminal block that sends sensor data via the thermocouple cable to the control system or a transmitter that sends sensor data via 4-20 ma signals to the control system. Multipoint thermometers Another method for creating a temperature profile is with a multipoint thermometer, a temperature sensor with a long thermowell containing multiple sensors. The Endress+Hauser itherm TM911 (Figure 4), for example, contains multiple sensors, arranged along the length of the thermowell. The thermowell can be longer than 100 ft, allowing it to extend vertically through a reactor or process vessel. 3

Figure 4: A multipoint sensor, such as the Endress+Hauser itherm TM911 (right), has multiple temperature sensors arranged along the length of its thermowell. The sensor can be placed so that it spans a reactor. While Figure 4 shows the sensor mounted across a reactor vessel, the sensor can also be mounted vertically or at an angle as needed to obtain different temperature profiles. Theoretically, the maximum immersion length of each individual multipoint thermometer can be equal to the reactor s internal diameter. Supports may be necessary to reinforce the end of the multipoint thermowell at the opposite side of the process connection. Measuring safely In the oil & gas, refining and chemical industries, safety is always a priority. Therefore, great care has to be taken when making multiple sensor connections because in almost all cases the measurements are being made in a hazardous area, and/or the contents of the vessel are hazardous. In the case of the sensor array, all of the process connections are potential leak points as they leave the vessel. With multiple connections, this can pose a problem. For both the sensor array and multipoint thermometer, one solution is to install a safety chamber (Figure 5) between the flange and junction box. This prevents process gases and liquids from escaping the vessel if any of the process connections leak. 4

Safety chamber module Junction box module Thermowell module Threaded rapid connection Flame lamination joint Figure 5: A safety chamber between the flange and junction box prevents process fluid or gas from escaping from the vessel if a leak occurs. After long term usage under demanding process conditions such as high corrosion rates, pressures and temperatures combined with a series of known and unpredictable process phenomenon such as turbulence, highly exothermic local chemical reactions and others a crack in the thermowell wall might occur, allowing the process media to fill the internal volume of the thermowell. In such a case, the process media can be contained by second and third barriers (Figure 6). Safety chamber containing the process medium at up to the same plant design parameters 3rd sealing barrier Pressure transmitters monitoring the pressure rates Process medium filling the thermowell Process medium in steady conditions Leakage through the 2nd sealing barrier process medium filling the safety chamber Figure 6: For extra safety, pressure transmitters can detect a leak. 5

By using a pressure vent on the multipoint flange, the leak can be detected and monitored via a pressure transmitter. The second barrier protects the safety chamber from any attack by highly corrosive process media, as well as from high process pressures or temperatures. Even after a breakthrough of the second safety barrier, there is no need for a plant shutdown as the safety chamber is in accordance with PED/ABSA pressure directives and their harmonized rules and calculation codes. This allows it to still safely operate until the next planned downtime. Summary Modern flow technologies provide instrument engineers with vital self-monitoring information. The format of such Applications for temperature profiling in the oil & gas and petrochemical industries are characterized by demanding process conditions in term of hazardous media with high pressures and temperatures combined with elevated corrosion rates, turbulence and vibration. Specialized instrumentation such as array sensors and multipoint thermometers are available to make required measurements, but care must be taken during installation and use. 6

Notes 7

Keith Riley has been a Product Business Manager with Endress+Hauser since April 2008. Prior to this, he was a Product Manager and Regional Sales Manager with L.J. Star Incorporated as well as a Product Manager for Penberthy (Tyco Valves). Overall, he has over 20 years of sales, marketing and instrumentation experience in the process industry. Tim Schrock, Area Manager for the Endress+Hauser temperature production center has 5+ years of experience in the instrumentation field. He started his career at Endress+Hauser and has held various roles such as Technical Support Engineer, Inside Sales Engineer, and Outside Sales Representative. In his current role, he works closely with the sales centers located in the US, Canada, Mexico, Brazil, and Chile on temperature applications, while also providing commercial and marketing support. Endress+Hauser, Inc. 2350 Endress Place Greenwood, IN 46143 Tel: 317-535-7138 888-ENDRESS (888-363-7377) Fax: 317-535-8498 info@us.endress.com www.us.endress.com WP01018T/24/EN/01.15 (06.15) Endress+Hauser, Inc., 2015