CRNE15-03 A-FGJ-G-V-HQQV 3x HZ

Similar documents
CRNE5-10 A-FGJ-G-E-HQQE 3x400 50HZ

CRE45-1 A-F-A-E-HQQE 3x HZ

CRN3-3 A-FGJ-G-V-HQQV 3x230/400 50HZ

CRE20-03 A-A-A-E-HQQE 3x HZ

CRN15-17 A-FGJ-G-V-HQQV 3x400/ HZ

Grundfos pump

CRN15-01 A-P-G-V-HQQV 3x230/ HZ

CRN1-27 A-P-G-V-HQQV 3x230/400 50HZ

CRN3-11 A-P-G-V-HQQV 11kW 3x400Y 50Hz

CRE5-16 A-A-A-E-HQQE 3x400 50HZ

CRN15-03 A-P-G-V-HQQV 3x400D 50 HZ

CRN20-02 A-FGJ-G-E-HQQE 3x400D 50 HZ

CRN45-5 A-F-G-V-HQQV 3x400/ HZ

CRN3-6 A-P-G-V-HQQV 3x230/400 50HZ

CRN A-F-G-V-HQQV 3x400/ HZ

CRE A-F-A-E-HQQE 3x HZ

CRE32-3 AN-F-A-E-HQQE 3x HZ

CRE15-01 A-F-A-E-HQQE 1x HZ

CRI3-6 A-FGJ-I-E-HQQE 3x230/400 50HZ

CR5-6 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR3-19 A-FGJ-A-E-HQQE 3x230/400 50HZ

CRE10-02 A-A-A-E-HQQE 1x HZ

CR3-6 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR1-3 A-FGJ-A-E-HQQE 1x220/240 50HZ

CRN45-10 A-F-G-V-HQQV 3x400/ HZ

CR A-F-A-V-HQQV 3x400/ HZ

CRN A-F-G-V-HQQV 3x400/ HZ

CRN3-25 A-P-G-E-HQQE 3x400D 50HZ

CR15-02 A-F-A-E-HQQE 3x400D 50 HZ

CRN A-F-G-V-HQQV 30kW 3x400D 50Hz

CRN5-7 A-P-G-E-HQQE 3x230/400 50HZ

CR5-26 A-FGJ-A-E-HQQE 3x400D 50HZ

CR3-2 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR10-02 A-A-A-E-HQQE 3x230/ HZ

CR5-16 A-A-A-E-HQQE 3x400D 50HZ

CR3-10 A-A-A-E-HQQE 3x230/400 50HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR45-5 A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR10-04 A-A-A-E-HQQE 15kW 3x400Y 50Hz

CRI1-6 A-P-I-E-HQQE 3x230/400 50HZ

CR10-01 A-A-A-E-HQQE 1x220/ HZ

CR3-13 A-A-A-E-HQQE 1x220/240 50HZ

CR1S-6 A-A-A-E-HQQE 1x220/240 50HZ

CR1-9 A-A-A-E-HQQE 1x220/240 50HZ

CR15-10 A-F-A-E-HQQE 11kW 3x400D 50Hz

CR10-10 A-A-A-E-HQQE 3x400D 50 HZ

CR120-2 A-F-A-E-HQQE 3x400/ HZ

CR1-6 A-A-A-E-HQQE 3x230/400 50HZ

CR1-3 A-A-A-E-HQQE 3x230/400 50HZ

CRN120-7 A-F-G-V-HBQV 75kW 3x400D 50Hz

CR45-10 A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-V-HBQV 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CRN5-5 A-FGJ-G-V-HQQV 3x230/400 50HZ

CRN10-09 A-FGJ-G-V-HQQV 3x400D 50 HZ

CRN A-F-G-V-HQQV 3x400/ HZ

CRN120-3 A-F-G-V-HQQV 3x400/ HZ

CRN5-22 A-P-G-V-HQQV 3x400D 50HZ

CRE A-F-A-E-HQQE 3x HZ

CR3-17 A-FGJ-A-E-HQQE 1x220/240 50HZ

CRN1S-9 A-P-G-V-HQQV 3x230/400 50HZ

NB80-160/161 A-F2-A-BQQE

CRI5-4 A-FGJ-I-E-HQQE 3x230/400 50HZ

CR5-7 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR5-18 A-FGJ-A-E-HQQE 3x400D 50HZ

CR1-4 A-FGJ-A-E-HQQE 3x230/400 50HZ

CRI15-04 A-FGJ-I-E-HQQE 3x400D 50 HZ

CRI10-04 A-FGJ-I-E-HQQE 3x230/ HZ

CRE20-08 A-F-A-E-HQQE 3x HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

CRI3-25 A-P-I-E-HQQE 3x400D 50HZ

CR45-3 A-F-A-E-HQQE 3x400/ HZ

CR15-01 A-F-A-E-HQQE 3x230/ HZ

CRN3-7 A-P-G-E-HQQE 3x230/400 50HZ

CR3-7 A-A-A-E-HQQE 1x220/240 50HZ

CR10-08 A-A-A-E-HQQE 3x400D 50 HZ

CRN10-02 A-P-G-E-HQQE 3x230/ HZ

NBE50-250/205 A-F2-A-BAQE

NB /193 A-F2-A-BAQE

CR15-14 A-F-A-E-HQQE 3x400/ HZ

CR1-4 A-A-A-E-HQQE 3x230/400 50HZ

CR5-9 A-A-A-E-HQQE 3x230/400 50HZ

CRNE15-12 A-FGJ-G-V-HQQV 3x HZ

NK /310A2F1AE-SBAQE

TP /4-A-F-A-BQQE 400Y 50HZ

CRIE10-03 A-FGJ-I-E-HQQE 3x HZ

Hydro MPC-E 2CRIE L GNL

TP /2-A-F-A-BQQE 400D 50HZ

TP /2-A-F-A-BAQE 400D 50HZ

NKE80-160/175A2F2AE-SBQQE

NB /263 AS-F2-A-BAQE

TPED /4-A-F-A-BQQE 3X400 50HZ

NB /438 A-F1-A-GQQE

TP /4-A-F-A-BUBE 400Y 50HZ

TPE /2-S-A-F-A-BAQE 3X400 50HZ

NBE40-125/139 AS-F2-A-BAQE

CM15-1 A-R-I-V-AQQV C-A-A-N

TPE /4-A-F-A-BAQE 3X400 50HZ

Transcription:

GRUNDFOS DATA BOOKLET CRNE15-3 A-FGJ-G-V-HQQV 3x4 5 HZ Grundfos Pump 96512744 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crne15/96512744/crne-15-3-a-fgj-g-v-hqqv.html info@lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89 BE > THINK > INNOVATE

Position Qty. Description 1 CRNE 15-3 A-FGJ-G-V-HQQV Product No.: 96512744 Note! Product picture may differ from actual product Vertical, multistage centrifugal pump with suction and discharge ports on same the level (in-line) enabling installation in a horizontal one-pipe system. Pump materials in contact with the liquid are in high-grade stainless steel. A cartridge shaft seal ensures high reliability, safe handling and easy service and access. Power transmission is via a split coupling. Pipework connection is via combined DIN-ANSI-JIS flanges. The pump is fitted with a 3-phase, fan-cooled asynchronous motor. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. Further product details An external sensor can be connected if controlled pump operation based on for example flow, differential pressure or temperature is required. The product carries the Grundfos Blueflux label. It represents the best from Grundfos within energy-efficient motors and frequency converters. Grundfos Blueflux solutions either meet or exceed legislative requirements such as the EuP IE3 grade. Steel, cast iron and aluminium components have an epoxy-based coating made in a cathodic electro-deposition (CED) process. CED is a high-quality dip-painting process where an electrical field around the products ensures deposition of paint particles as a thin, well-controlled layer on the surface. An integral part of the process is a pretreatment. The entire process consists of these elements: 1) Alkaline-based cleaning. 2) Zinc phosphating. 3) Cathodic electro-deposition. 4) Curing to a dry film thickness 18-22 my m. The colour code for the finished product is NCS 9/RAL 95. Pump A standard split coupling connects the pump and motor shaft. It is enclosed in the pump head/motor stool by means of two coupling guards. 1/8

The pump head and flange for motor mounting is made in one piece (cast iron). The pump head cover is a separate component (stainless steel). The pump head has a combined 1/2" priming plug and air vent screw. The pump is fitted with a balanced O-ring seal unit with rigid torque transmission system. This seal type is assembled in a cartridge unit which makes replacement safe and easy. Due to the balancing, this seal type is suitable for high-pressure applications. The cartridge construction also protects the pump shaft from possible wear from a dynamic O-ring between pump shaft and shaft seal. Primary seal: - Rotating seal ring material: Silicon carbide (SiC) - Stationary seat material: Silicon carbide (SiC) This material pairing is used where higher corrosion resistance is required. The high hardness of this material pairing offers good resistance against abrasive particles. Secondary seal material: FKM (fluorocarbon rubber) FKM has excellent resistance to oils and chemicals. Above 9 C, FKM should only be used in media without water. The shaft seal is screwed into the pump head. The chambers and impellers are made of stainless steel sheet. The chambers are provided with a PTFE neck ring offering improved sealing and high efficiency. The impellers have smooth surface, and the shape of the blades ensure a high efficiency. The pump has a stainless steel base mounted on a separate base plate. The base and base plate are kept in position by the tension of the staybolts which hold the pump together. The discharge side of the base has a drain plug. The pump is secured to the foundation by four bolts through the base plate. The flanges are fastened to the base by means of locking rings. 2/8

Motor The motor is a totally enclosed, fan-cooled motor with principal dimensions to IEC and DIN standards. The motor is flange-mounted with tapped-hole flange (FT). Motor mounting designation in accordance with IEC 634-7: IM B 14 (Code I) / IM 361 (Code II). Electrical tolerances comply with IEC 634. The motor requires no external motor protection. The motor control unit incorporates protection against slow- and quick-rising temperatures, e.g. constant overload and stalled conditions. Technical data Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Technical: Speed for pump data: Rated flow: Rated head: Shaft seal: Approvals on nameplate: Materials: Pump housing: Impeller: Water 253.. 363 K 293 K 998.2 kg/m³ 292 rpm 17 m³/h 33.2 m HQQV CE,TR Stainless steel DIN W.-Nr. 1.448 ASTM A 351 CF 8M Stainless steel DIN W.-Nr. 1.441 AISI 316 Installation: Maximum ambient temperature: 313 K Max pressure at stated temp: 25 bar / 9 C 25 bar / -2 C Flange standard: DIN Pipe connection: DN 5 Pressure stage: PN 16 Flange size for motor: FT13 Electrical data: Motor type: 1LC Number of poles: 2 Rated power - P2: 3 kw Power (P2) required by pump: 3 kw 3/8

Position Qty. Description Mains frequency: 5 Hz Rated voltage: 3 x 38-48 V Rated current: 6,2-5, A Cos phi - power factor:,94-,92 Rated speed: 36-349 rpm Efficiency: IE3 87,1% Enclosure class (IEC 34-5): IP55 Insulation class (IEC 85): F Others: Label: Grundfos Blueflux Minimum efficiency index, MEI :.7 Net weight: 63 kg Gross weight: 69 kg 4/8

96512744 CRNE 15-3 5 Hz H [m] CRNE 15-3, 3*4 V, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ eta [%] 45 1 % 4 35 3 25 1 2 8 15 6 1 4 5 25 % 2 2 4 6 8 1 12 14 16 18 2 22 P [kw] Q [m³/h] NPSH [m] 3. P1 12 2.5 2. P2 1 8 1.5 6 1. 4.5 2. 5/8

Description Value Product name: CRNE 15-3 A-FGJ-G-V-HQQV Product No: 96512744 EAN number: 57396617596 Technical: Speed for pump data: 292 rpm Rated flow: 17 m³/h Rated head: 33.2 m Impellers: 3 Shaft seal: HQQV Approvals on nameplate: CE,TR Stages: 3 Pump version: A Model: A Materials: Pump housing: Impeller: Material code: Code for rubber: Stainless steel DIN W.-Nr. 1.448 ASTM A 351 CF 8M Stainless steel DIN W.-Nr. 1.441 AISI 316 G V Installation: Maximum ambient temperature: 313 K Max pressure at stated temp: 25 bar / 9 C 25 bar / -2 C Flange standard: DIN Connect code: FGJ Pipe connection: DN 5 Pressure stage: PN 16 Flange size for motor: FT13 H [m] 45 1 % 4 35 3 25 2 15 1 5 25 % CRNE 15-3, 3*4 V, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ 5 1 15 2 P [kw] 2 1 177 198 G 1/2 G 1/2 18.5 x 21.8 G 1/2 165 127 9 65 26 12.5 13 2 3 215 248 Q [m³/h] P1 P2 eta [%] 1 8 6 4 2 NPSH [m] 4 2 Liquid: Pumped liquid: Water Liquid temperature range: 253.. 363 K Liquid temp: 293 K Density: 998.2 kg/m³ Electrical data: Motor type: 1LC Number of poles: 2 Rated power - P2: 3 kw Power (P2) required by pump: 3 kw Mains frequency: 5 Hz Rated voltage: 3 x 38-48 V Rated current: 6,2-5, A Cos phi - power factor:,94-,92 Rated speed: 36-349 rpm Efficiency: IE3 87,1% Enclosure class (IEC 34-5): IP55 Insulation class (IEC 85): F Motor protec: B Motor No: 8575581 Group 3 Group 2 NC C NO L1 L2 L3 335 463 1: Digital input 9: GND (frame) 8: +24 V 7: Sensor input B: RS-485B Y: Screen A: RS-485A -1 V /4-2 ma 4-2 ma Group 1 1/ B Y A 1 9 8 7 STOP 6: GND (frame) 5: +1 V 4: Setpoint input 3: GND (frame) 2: Start/stop RUN /4-2 ma -1 V 1K 6 5 4 3 2 Others: Label: Grundfos Blueflux Minimum efficiency index, MEI :.7 Net weight: 63 kg Gross weight: 69 kg Config. file no: 9611586 6/8

96512744 CRNE 15-3 5 Hz 177 198 335 G 1/2 G 1/2 463 G 1/2 18.5 x 21.8 9 127 165 13 2 3 26 65 12.5 215 248 Note! All units are in [mm] unless others are stated. Disclaimer: This simplified dimensional drawing does not show all details. 7/8

96512744 CRNE 15-3 5 Hz NC C NO Group 2 L1 L2 L3 Group 3-1 V /4-2 ma 4-2 ma 1/ 1 9 8 7 B Y A 1: Digital input 9: GND (frame) 8: +24 V 7: Sensor input B: RS-485B Y: Screen A: RS-485A Group 1 STOP /4-2 ma -1 V RUN 1K 6 5 4 3 2 6: GND (frame) 5: +1 V 4: Setpoint input 3: GND (frame) 2: Start/stop Note! All units are in [mm] unless others are stated. 8/8

Disclaimer: The information about the Grundfos pump in this document may be outdated. Data may be subject to alterations without further notice. Please contact us to verify the data above is still accurate/up-to-date. All information is copyright Grundfos. info@lenntech.com www.lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89