RD712 & RD712XL Remote Displays. Model 615 / 615XL Indicator User s Manual

Similar documents
Twin-Column Motorized Tension, Compression & Cycle Tester (M5KNE & M10KNE) User s Manual

Model 8000XL OPERATOR MANUAL

Model 7400 OPERATOR MANUAL

MODEL. TI-500 RF Series. User Manual. Digital Weight Indicator (with wireless weighing capability)

Standard features on all Agricultural Weigh Bars. Steel potting shield Protects against impacts better than plastic shields.

Digital Scale. Revision 1.0 August 17, Contents subject to change without notice.

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

Compact Scales. Software Revision V1.25 & above

1. Introduction Specifications Operation Guide Trouble shooting Note... 13

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

Model 2500 Horsepower Computer System User Manual

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

PORT-A-WEIGH CRANE SCALES

CONTENTS 1 V400 SERVICE MANUAL. 1.0 Vulcan On-Board Scale System... 5

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

C802/C802D/C802TD/C820 Alternators Troubleshooting Guide

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

SSP-Series Portable Balances Operation Manual

System III Wiring Information 54-12

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

User Guide. Digital Shipping Scale S150

Model DS7060 Handrail Scale. User Manual

Assembly instructions WAES

Price Computing Scale D Series Operation Manual

OCS Series. High Resolution Digital Crane Scale. User Guide

SC-Series. User Manual. American Weigh Scales. SC-501, SC-501A (500g x 0.01g) SC-2KG, SC-2KGA (2000g x 0.1g)

THUNDERBIRD. Agricultural Weighing Systems SS1000 Instructions

MDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

RESISTIVITY MONITOR/CONTROLLERS

CONTENTS 1 V200 SERVICE MANUAL

Virtual Measurements & Control. VC210 Operators Manual

Battery Management Innovation. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

GRAVITY MEASUREMENT, INC.

Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation

500Z Owner's Manual & Troubleshooting

The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3

Fairbanks Scales OPERATING MANUAL. HAZARDOUS ENVIRONMENT INDICATOR Model H D. BULLETIN SJ4572 / Issue #2

Installation & Calibration

Operating Guide TSFS-300 Air Parcel Conveyor Scale With automatic totalizing

SPC Series. Digital Scale. Operation Manual

SKY-WEIGH HELICOPTER CARGO HOOK LOAD MONITORING SYSTEM. User Guide Quality Industrial Weighing and Force Measurement Equipment

N1233 Series Troubleshooting Guide for N Alternator

OCS-T High Resolution Digital Crane Scale

C.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

CS-250 Series. CHAIR SCALE SERVICE MANUAL (v1.06d)

Model 594KL Digital Chair Scale

TS-PFS. User s Guide. Portable Feeder Scale For Weigh Session Totals. Totalized Weight Item Weight Item Count Nonvolatile Memory. Guide version 1.

1. Disclaimer Warnings Introduction Display and Commands... 5

CAUTION-ELECTRICALLY OPERATED PRODUCT

OVERVIEW OF CONTROLS

Electronic Crane Scale

TABLE OF CONTENTS. Page 1

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

500 Series Troubleshooting Guide for C520 Alternators

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002

NPS Series. Pallet Jack Scale Operator s Guide (V1611)

Installation and User Manual. with RAIN SENSOR.

EG1069X. Generator Electronic Governor Controller Operation Manual

Canadian Manufacturer of Quality Weighing Systems

OPERATOR TROUBLESHOOTING GUIDE

SERVICE MANUAL Valor 1000 Scales

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR

DMC mA Positioner

1100 Series Piston Type Differential Pressure Gauges

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

User s Guide. EZ-Bar Livestock Scale WEIGH BARS AND DIGITAL INDICATOR. WB-40 Weigh Bars TS-700 WB Digital Indicator. Guide version 1.

Patient Lift Scale Indicator Owner s Manual

MPT-200A SPECIFICATIONS AND OPERATING INSTRUCTIONS

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

PAGE Both power cords must be connected & powered to operate the E-TES SD 120 volt unit.

Easy Weigh ADVANCED COUNTING SCALE MODEL: AC-100 OWNER S MANUAL VER 1.00

W2175 LOAD INDICATOR Calibration (Version cal2175 V2.0)

Operation and Service Manual WeighSouth WSI-600 Person Weigher

6500DC Dual Motor Wireless Controller Kits

INSTALLATION/OPERATING INSTRUCTIONS TSC

EVAPORATIVE EMISSIONS TESTER KLI9210DLX OPERATION MANUAL

R & D SPECIALTIES ROTROL I USER'S MANUAL

Installation & Calibration Manual

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

B-RAD Select USER MANUAL TABLE OF CONTENTS

CITIZEN. series. Precision Balances

ENGINE GOVERNING SYSTEMS

FieldView External Charger. User Guide

This document describes:

Troubleshooting Guide for N1225-1/N1237-1/N Alternators

Plasma Display Electric Pop-Up Lift (PUL)

Thunder Power Tarp Kit Operation. Dual Arm Curb Side Stowing Single Arm Curb Side Stowing Flex Arm Curb Side Stowing.

GRAIN CART RETROFIT TRACK SLIDE-IN-HITCH SCALE SYSTEM

SWII Users Manual. Intercomp Co County Road 116 Minneapolis, MN (763) Fax

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

WARNING! DO NOT WELD TO THE WEIGH BARS OR ANY STRUCTURE THAT THEY ARE ATTACHED TO

N1387 Series Troubleshooting Guide for N Alternators

Signet Pressure Transmitter

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

Spray Height Controller

Using the PST-2000 with Peterbilt Trucks. Document Number B

LN3 Series Motor and Drives

Transcription:

RD712 & RD712XL Remote Displays Model 615 / 615XL Indicator User s Manual

EUROPEAN COUNTRIES WARNING This is a Class A product. In a domestic environment this product may cause radio interference in which the user may be required to take adequate measures. CAUTION Risk of electrical shock. Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. Weigh-Tronix reserves the right to change specifications at any time. 06/02/03 615_U.P65 PN 29589-0016N e1 Printed in USA 2 Model 615/615XL Indicator User s Manual

Table of Contents Key Functions... 5 Operational Overview... 6 Zeroing and Weighing... 6 Perform a Tare Function... 7 Accessing the Gross/Net Weight... 7 Capturing and Printing a Weight Reading... 7 Selecting Motion Filtering... 8 Display Messages... 8 Troubleshooting... 9 Power-on Failure... 9 Indicator Lock-up... 10 Inaccurate Weight Reading... 11 Service Repairs... 11 Cable Connectors... 12 RD 712/XL Remote Display... 13 Pages are numbered consecutively beginning with the cover page. Model 615/615XL Indicator User s Manual 3

Specifications and Features Indicator enclosure: Digital Display: Display-Update Rate: Accuracy: Linearity: Repeatability: Water/dust resistant, polycarbonate enclosure. Dimensions: 8.75" H x 10.5" W x 6.5" D. A standard Weigh-Tronix mounting bracket is affixed to the back of the Model 615/XL. LCD, 5½ digits plus minus sign. 1.0"-high digits (M 615), 2.0"-high digits (M615/ XL). Fiber optic backlight. Two times per second. ±0.1% of applied load ±1 grad ±0.01% of capacity ±0.01% of capacity or ±1 grad, whichever is greater Power: 10 to 18 volts DC negative ground only, at.09 ampere for 4-pin Weigh Bars, and at.17 ampere for 5-pin Weigh Bars Circuit Protection: Environment: One 5-ampere fuse -20 to +140 F, or -29 to +60 C, to 95% noncondensing humidity Weigh-Bar Drive Capacity Calibration: Zero-balance Range: Analog Span Range: Capacity and Increment: 10-350 Ohm Weigh-Bars Front-panel calibration and spanning for all types of Weigh-Bars and load cell application capacities up to 200,000 pounds ±1 mv/v, via front-panel ZERO key 0.20 mv/v to 1.0 mv/v 20,000 X 20, 10, 5, 2, 1 lb or kg 200,000 X 200, 100, 50, 20, 10 lb or kg 2,000 X 2, 1,.5,.2,.1 lb or kg 200 X.2,.1,.05,.02,.01 Ib or kg Options Remote Display or Printer Output Radio Remote: Transmitter/receiver enables remote capabilities on the ZERO button Accessories DC Convertors: 117 VAC to 13.6 VDC RD712/XL Remote Display Printers Junction Boxes: For 7-pin connector unit. 4 Model 615/615XL Indicator User s Manual

Model 615/XL Front Panel Figure 1a: Front Panel of Model 615 Indicator Figure 1b: Front Panel of Model 615XL Indicator Key Functions ON OFF G/N TARE ZERO SETUP Pressed to power-on the indicator. Pressed to remove power. Gross /Net key toggles between gross weight and net weight Tare key performs a tare, and then shows net weight. Pressed to zero-balance the scale. Pressed to scroll through three filtering options: lowest, medium, and highest filtering capabilities. PRINT/SELECT 1. Pressed in conjunction with the SETUP key to select the appropriate filtering option. 2. Pressed to capture and lock in on a weight reading and transmit the reading to a printer or other datareceiving device. Model 615/615XL Indicator User s Manual 5

Operational Overview Zeroing and Weighing The Model 615/XL Farm Indicator shown in Figure 1 is designed to work in all types of farm weighing applications: animal scales, platform scales, mixer-wagon scales, grain-cart scales, and grinder / mixer scales. Motion Filtering The Model 615/XL is adaptable in several different farm weighing applications because it offers three user-selectable options for motion filtering. In applications where displayed weight readings are unstable, you can obtain a more stable display by changing the degree of filtering capability (See Selecting Motion Filtering). Operational Modes The Model 615/XL has three modes gross weighing mode, capture mode and net mode. TARE and G/N keys are used for accessing Gross and Net modes. In gross weighing mode, the displayed weight represents total live scale weight. The indicator always powers up in gross weighing mode. Capture mode is especially useful in an animal scale application, where animal motion can cause unstable display readings. Capture mode grabs the correct weight reading and locks it onto the display so the user can easily view the animal s weight. Net mode uses the TARE and G/N keys. Depressing Keys When you depress a key correctly, the display blinks. The single blink always means that your depression of a key has made proper internal contact for activating your intended function. Because extreme cold slows the reaction of liquid crystal, you can expect that in very cold weather, the display will take longer than usual to respond to keyed requests. Cable Connections Make sure all cables are connected as shown in Figure 2 (see page 8). Note: RS232/Remote display output is available as an option. Power Requirements Voltage to the Model 615/XL must be 10-18 volts DC, negative ground only. If voltage drops below ten volts, the Model 615/XL will automatically shut itself off, protecting the battery from being completely drained. Consult the Model 615/XL Service Manual for instructions on disabling the automatic shut-off. 1. Press ON... The display says HELLO, then a weight value is displayed in gross weighing mode. 2. Press ZERO to zero the scale before weighing... Zero value is displayed, and the scale is ready to weigh. 3. Place weight on the scale... The gross value of scale weight is displayed. Depending on your application, an unstable gross weight display at this time may mean you ll want to change the motion filtering selection (See Selecting Motion Filtering ). 6 Model 615/615XL Indicator User s Manual

Perform a Tare Function Press the TARE key (Display flashes) and net weight is shown. Press and hold the TARE key to show the gross weight. If you press for more than 3 seconds the display returns to the gross mode. If you do this, the tare is cleared from memory. If power is removed from the indicator, this also clears the tare. If you release the TARE key in less than three seconds, it returns to showing the net weight. (Operates just like having the XM710 transmitter option) Pressing the ZERO key always establishes a true zero balance even if a tare is being displayed. Or in other words clears the tare and sets the true zero point. Accessing the Gross/Net Weight Press the G/N key to toggle between the gross and net display. If there is no tare, the display will simply flash and show the gross weight. Capturing and Printing a Weight Reading 1. With the desired weight on the scale, press PRINT/SELECT to access the capture mode... The display flashes weight readings until the Model 615/XL captures the correct weight and locks the captured reading on the display. 2. Return to the gross weighing mode by either of the methods below: A. Press SETUP... OR B. Remove or add at least 25% of locked-in scale weight as displayed in capture mode... In applications where a printer or other data-receiving device is connected to the Model 615/XL, a captured weight reading also indicates the reading has been successfully transmitted. The display returns to gross weighing mode. Model 615/615XL Indicator User s Manual 7

Selecting Motion Filtering The motion-filtering function and the display-update rate work together. Experiment with the three filtering options shown below to determine the appropriate filtering capability and display response time for your weighing application. In applications where displayed weight readings are somewhat unstable, as is typical for animal scales, you can help stabilize the gross weight by selecting a higher filtering option. The filtering function is always factorypreset to the lowest filtering capability. 1. From the gross weighing mode, press SETUP... One of these filtering options is displayed: Lowest filtering capability Medium filtering capability Highest filtering capability 2. Scroll through the options by pressing SETUP. 3. Select the displayed filtering capability by pressing PRINT/SELECT... Stop when the desired filtering capability is displayed. The display returns to gross weighing mode. Display Messages The Model 615/XL is being reinitialized. This message is displayed briefly at the time of power-on. The Model 615/XL is in a state of overcapacity. The Model 615/XL is in a state of under-capacity. The system is not functioning properly. Weight is not being calculated because scale weight is either too high or too low. (Refer to information on INDICATOR LOCKUP in TROUBLESHOOTING section of manual.) The Model 615/XL is set to its lowest filtering capability. 8 Model 615/615XL Indicator User s Manual

The Model 615/XL is set to its medium filtering capability. The Model 615/XL is set to its highest filtering capability. In capture mode, when the display flashes between fluctuating gross scale weight and a blank display, the Model 615/XL is trying to capture the correct weight of an unstable load. When the scale has determined the correct scale weight, it locks on a steady display of the weight. This message is displayed momentarily to indicate weight data has been transmitted to the printer. This is true only if the capture mode has been disabled so that the PRINT/SELECT key can be used only for printing. Troubleshooting If you experience problems in the operation of your system, read through these troubleshooting steps and perform those which are appropriate. This information may help you to correct the following operational difficulties without calling your supplier or sending your equipment in for repair: Power-on Failure Indicator Lockup Inaccurate Weight Readings Instructions for sending an indicator in for repair are provided in the last section under Service Repair. Power-on Failure If your indicator fails to power-on, check the following possible problem sources in the order given. Attempt to power-on after trying each of these four troubleshooting steps: 1. Check input voltage. Required voltage is 10-18 volts DC negative ground. The Indicator will automatically turn off if voltage coming in drops below 10 volts or rises above 18 volts. 2. Disconnect and check the power cable connector at the vehicle or AC to DC converter, clean if necessary, and reconnect. 3. Replace the fuse. Sometimes, a bad fuse can be recognized by an obvious break in the wire filament. Such a break is not always observable, however, and getting a successful power-on after changing a fuse is often the only way of knowing that fuse was indeed defective. Model 615/615XL Indicator User s Manual 9

Make sure the new fuse is the proper size and has a current rating of five amperes. Using a fuse with too high a current rating can cause costly damage to the indicator and will void your warranty. The same is true for substituting wire, or a nail, or any other object in place of a fuse. Place nothing in the fuse connector except a proper fuse. Try to power-on after changing the fuse; if unsuccessful, proceed to the next troubleshooting To replace a fuse: First locate the fuse cap on the bottom panel of the indicator. Then... 1. Turn the cap counterclockwise and lift out the fuse-and-cap assembly. 2. Remove the old fuse from the cap and insert a new fuse. 3. Replace the fuse and cap assembly in the fuse connector. 4. Test the Indicator and the Cables to isolate the source of the problem. 1. Disconnect all cables on the bottom panel of the indicator except for the power cable. Do disconnect the Weigh Bar cables, and, if present, the printer/remote display cable. 2. Now try powering-on. If this is not successful, your problem is in the indicator and you should contact your supplier. 3. If you are able to power-on with only the power cable connected, your problem is probably not in the indicator; continue troubleshooting. 4. With the power still on, plug in the cables, one at a time Weigh Bar cables first, then the printer / remote display cable until plugging in one of the cables causes the indicator to shut off. That cable is the bad one and needs to be repaired or replaced. Indicator Lock-up A locked-up indicator is represented by an Err (error) display message. Test the Weigh Bar Cables to isolate the source of the lockup problem, as follows: 1. Disconnect all Weigh Bars. 2. Try to zero the indicator by pressing ZERO. If your indicator will not zero with the Weigh Bars disconnected, then the problem is in the indicator; contact your supplier. If you are able to zero your indicator with the Weigh Bars disconnected, then the problem is probably in the Weigh Bars; continue troubleshooting. 3. Reconnect all Weigh Bars; you will see Err displayed again. 4. If your Weigh Bar connectors have the four-pin configuration, disconnect one Weigh Bar and connect an adapter plug in its place. If your Weigh Bar connectors have the five-pin configuration, disconnect one Weigh Bar. No adapter plug is necessary with five-pin Weigh Bar connectors. 10 Model 615/615XL Indicator User s Manual

5. Then try to zero the indicator. 6. Repeat Steps 4 and 6 with each Weigh-Bar cable, making sure each time that all cables are connected except the one you removed (for five-pin connectors) or replaced with an adapter plug (for four-pin connectors). A defective Weigh Bar may be easily recognized with this method, for when a defective bar is replaced with an adapter plug (for four-pin connectors), or removed (for five-pin connectors), the indicator will zero properly. Inaccurate Weight Readings 1. Visually Inspect the Scale System for apparent problems and improper installation, as follows: a. Check each cable, from source to indicator, for stress, cuts, breaks, or abrasions. b. Unplug and reconnect each connector at the indicator to verify that it is tight and making good contact. c. Check between the supporting structure and the weighing structure for debris that might restrict Weigh Bar movement. d. Make sure the supporting structure and the weighing structure do not touch each other at any point except at the Weigh Bars. Compare Weight Readings for All Weigh Bars, as follows: Position a person or heavy object on the platform above each Weigh Bar, one bar at a time, and compare weight readings for the same person or same object. For each weighing, the weight itself will be off-center, favoring a single Weigh Bar; therefore, none of the readings will be accurate. However, your readings obtained by weighing the same person or object above each Weigh Bar should be very similar to each other. A single Weigh Bar reading that is significantly different from the others is probably defective. Service Repairs If you find the indicator or one or more of the Weigh Bars to be defective, send your equipment back to the factory for repair, postage prepaid. Include this information: 1. Your name and address 2. Supplier name and address 3. Date of purchase 4. Very important: An informal note describing symptoms of the problem. Model 615/615XL Indicator User s Manual 11

Pin A = +12 VDC Pin B = Ground Pin A = +12 VDC Pin B = Ground Pin A = +12 VDC Pin B = Ground Figure 2 Cable Connectors on Bottom Panel of Model 615/XL Indicator 12 Model 615/615XL Indicator User s Manual

RD 712/XL Remote Display The RD712/XL is a remote display that is compatible with the Model 615/XL. (An RD712/XL output option is required on the Model 615/XL for interfacing.) The interface cable plugs directly into the bottom of the Model 615/XL (see Figure 2 below). When using the remote display, any data displayed on the Model 615/XL is also displayed on the RD712/XL. The functions available on the RD712/XL are: ZERO RESET Pressing this key on the RD712/XL performs the same function as pressing ZERO on the Model 615/XL. Model RD 712 Remote Display Model RD 712XL Remote Display Optional radio remote transmitter (XM710-L) and receiver An optional radio remote transmitter and receiver can be installed in either the Model 615/XL or the RD 712/XL. When you press this key, the displayed weight is tared and the display will show zero weight. Press and hold the button (for less than three seconds) to view gross weight. When you release the button the displayed weight will be tared again. If you hold the button longer than three seconds the display will return to gross mode. Model 615/615XL Indicator User s Manual 13

Weigh Bar is a registered trademark of Weigh-Tronix Inc. Weigh-Tronix 1000 Armstrong Dr. Fairmont, MN 56031 USA Telephone: 507-238-4461 Facsimile: 507-238-8283 e-mail: ag@weigh-tronix.com www.agscales.com