Cessna Citation XLS - Electrical

Similar documents
SYSTEM LOAD CHARTS AND BUS SCHEMATICS

SECTION IV ELECTRICAL & LIGHTING

REFERENCE: 2861 wings 2044 trunk 4904 total BEW 10,655 BOW 11,185 Max Useful load 5115 MLanding ZFW FUEL BURNS 11min min min

24 ELECTRICAL DC ELECTRICAL SYSTEM DESCRIPTION

Dash8 - Q400 - Pneumatics

Pneumatic Air Conditioning System Citation, Citation I

Cessna Citation XLS - Anti-Ice & De-Ice Systems

SECTION 2-05 ELECTRICAL

CHAPTER 96 ELECTRICAL SYSTEM

FORM: 2391 DRAWING NO: ICA-560XL Cessna Aircraft Company P.O Box 7704 WICHITA, KS 67277

Introduction. APU Location

DASSAULT AVIATION Proprietary Data

Central Warning Systems

Cessna Citation XLS - Environmental & Temperature Control

Canadair Regional Jet 100/200 - Auxiliary Power Unit

DASSAULT AVIATION Proprietary Data

BEFORE START & START (C/R)

CHAPTER 6 ELECTRICAL SYSTEMS

CHAPTER 12. Page TABLE OF CONTENTS /02 DESCRIPTION. General Description Controls and Indicators COMPONENTS

OVERHEAD PANEL PROCEDURES FLASH CARDS

CIRRUS AIRPLANE MAINTENANCE MANUAL

B777. Electrical DO NOT USE FOR FLIGHT

MAJESTIC Q400 SHARED COCKPIT FLOWS CHECKLISTS MULTIPLAYER OPERATIONS.

King Air B90. Speeds (KIAS)

CHAPTER 11. Page TABLE OF CONTENTS /02 DESCRIPTION. General Description Controls and Indicators

POWER ON CHECK LIST COCKPIT PREPARATION

24-00 ELECTRICAL POWER

ATA 24 ELECTRICAL POWER

CIRRUS AIRPLANE MAINTENANCE MANUAL

DASSAULT FALCON 900EX EASY SYSTEMS SUMMARY

canaaair chaiiencjer

CESSNA SECTION 4. Unless otherwise noted, the following speeds are based on a maximum weight of 2550 pounds and may be used for any lesser weight.

This chapter contains information on DC Generation, External Power, and Electrical Load Distribution.

DASSAULT AVIATION Proprietary Data

The Straight Word. Cessna 208 Caravan 208 Caravan I & 208B Grand Caravan Series

canadair chzflleriqer OPERATING MANUAL PSP 601A-6 SECTION 5 AUXILIARY POWER UNIT (APU)

DESCRIPTION AND OPERATION ICE DETECTION SYSTEM

SECTION III HYDRAULICS & LANDING GEAR

B737 NG Anti Ice & Rain

FUEL MODEL 750 BAGGAGE COMPARTMENT SMOKE DETECTION

ATA 49 AUXILIARY POWER UNIT

HYDRAULICS & LANDING GEAR

SECTION II AIRPLANE AND SYSTEMS MODEL 750 HYDRAULIC

DESCRIPTION AND OPERATION FUEL SYSTEM

ALT #2 fail light on but Alternator is still charging (MCU 100/120):

NORMAL PROCEDURES. TABLE OF CONTENTS Page

The Straight Word. Beechcraft 90 King Air B90 Series. Condition Lever. Set for Takeoff Cabin Altitude Controller Set Cruise Level + 1

SUPER KING AIR B200C Registration : PK - YGT Total Time : 9116

General. APU Control System. APU Door System

NORMAL PROCEDURRES CHECKLIST PA T SENECA II PREFLIGHT CHECK INSIDE CABIN OUTSIDE CABIN

CHAPTER ICE AND RAIN PROTECTION SYSTEM

Bombardier Global Express - Hydraulics

Bombardier Challenger Auxiliary Power Unit

DC Generation. 1. General. A. DC Generation

Dash8-200/300 - Auxiliary Power Unit APU CONTROLS AND INDICATORS. Page 1

CIRRUS AIRPLANE MAINTENANCE MANUAL

AIRPLANE OPERATIONS MANUAL SECTION 2-15

SECTION 5 AUXILIARY POWER UNIT (APU) TABLE OF CONTENTS LIST OF ILLUSTRATIONS. Title

ELECTRICAL MODEL 750 GENERAL DIRECT CURRENT (DC) POWER

Interior Pre Flight Documents: Check Control Wheel Lock: Remove Flight Controls: Check Instruments: Check for Damage Switches: Verify All Off Master

Pilot's Manual Wcyflom v# ANTI-ICE & ENVIRONMENTAL. Learjet 31A

Diamond DA40 TDI OH-STL

EMERGENCY PROCEDURES ENGINE FIRE DURING START/GROUND OPERATIONS STARTER ENERGIZED ANNUNCIATOR ILLUMINATED. Memory items are printed in red.

2007 A119 Koala Price: Make an Offer

ASSIGNMENT Chapter 4 AIRCRAFT ELECTRICAL SYSTEMS

STUDENT HANDOUT BOOKLET

Vso 61. Vs1 63. Vr 70. Vx 76. Vxse 78. Vy 89. Vyse. 89 (blue line) Vmc. 61 (radial redline) Vsse 76. Va 134) Vno 163

by Greg Whiley Aussie Star Flight Simulation

STUDENT HANDOUT BOOKLET

Doug Carmody Beaufort, SC September 2013

V - Speeds. RV-10 V fe Flaps Speeds Trail (0 deg) Half (15 deg) Full (30 deg) 122 kias 96 kias. 80 kias

OPERATIONS MANUAL FTO SECTION : 06.04

STUDENT HANDOUT BOOKLET

King Air 200. Self-Check Exercises. cae.com. Revision 0

Examen Teórico sobre Habilitación de Tipo B (Última actualización: Septiembre 2016)

EXAMEN POR MATERIAS PARA USO DE LOS POSTULANTES A LA HABILITACIÓN DE TIPO EN MATERIAL B733. ENERO 2018

DASSAULT AVIATION Proprietary Data

EMERGENCY GEAR DOWN HANDLE CHECK VALVE GEAR DROP TO EXTEND POSITION DOOR SELECTOR DOOR SELECTOR VALVE UPLOCK RELEASE CYLINDER DOOR CYLINDER

PA GURW (December 30, 2000) PRE-START. Langley Flying School. Airspeeds (MPH) for Safe Operation. Cockpit Checks

CESSNA 172S NAV III VFR CHECKOUT POH EXAMINATION (Based on N1129K, serial no. 172S revised 10/05/06)

2006 Embraer Legacy 600

Vr V STANDARD EQUIPMENT LIST

Pilot's Operating Handbook Supplement AS-03

Differences Training

CESCOM 20 - Projected Maintenance Due

P68 Observer 2 STANDARD EQUIPMENT LIST V

DASSAULT AVIATION Proprietary Data

CIRRUS AIRPLANE MAINTENANCE MANUAL

AIRPLANE FLIGHT MANUAL AQUILA AT01 AIRPLANE FLIGHT MANUAL - SUPPLEMENT AVE28 GLASS COCKPIT. equipped with ASPEN EFD1000 PFD

CHAPTER 77 ENGINE INDICATING

1. Aircraft General (0 Hours 39 minutes) 2. Doors (0 Hours 33 minutes) 3. EFIS (2 Hours 55 minutes) 4. Exterior Lighting (0 Hours 24 minutes)

Surface and Brakes Anti-Ice Systems

CHAPTER ELECTRICAL

FBA-2C3, FBA-2C4 CHAPTER 33 LIGHTS. Uncontrolled Copy

General. Airfoil Anti-Ice System

N-1 1 Oct 06 N-1 1 Oct 06

INDEX. Preflight Inspection Pages 2-4. Start Up.. Page 5. Take Off. Page 6. Approach to Landing. Pages 7-8. Emergency Procedures..

STALL WARNING SYSTEM 1. DESCRIPTION A.

Electrical System B-17 Technical Session for Flight Engineers

CESSNA CITATION C750 (CITATION X) PUNTA BRAVA S.A. (Rev Abril 2012)

Transcription:

GENERAL Electrical power for the Citation XLS comes primarily from DC sources originating with the starter/ generators, the Auxiliary Power Unit (APU) or the battery. A receptacle below the left engine pylon is provided for connection of a 28 VDC external power unit. ALTERNATING CURRENT (AC) POWER The Citation XLS utilizes a single alternating current (AC) inverter to power the electroluminescent panel lighting. In addition, AC power from engine-driven alternators is used to power the electrically heated windshield. For a complete system description, refer to Anti-Ice/Deice description in this section. NOTE Avionics equipment in the Citation XLS is DC-powered, and therefore does not require the use of AC inverters. DIRECT CURRENT (DC) POWER The direct current (DC) power distribution system consists of two separate and independent DC power sources which supply the system. In the event these DC power sources fail, the battery system will supply emergency power to selected systems. The direct current (DC) power distribution system consists of a battery system, an APU system, two 300 amp starter/generators, two Generator Control Units (GCUs), a distribution system, a battery switch, an avionics switch, two generator control switches, two ammeters and a voltmeter with a selector switch. A description of various components follows. BATTERY SYSTEM The battery system consists of the battery, the battery disconnect relay and associated switches. The 44-amp battery is used to provide power for engine starting, and to provide power to the emergency battery bus in the event of a dual generator failure. The battery is located in the left hand aft fairing and has an overboard vent. A battery disconnect relay is provided for the battery. During normal operation, the relay remains in a de-energized position. During a battery overtemperature condition, the battery may be disconnected by operating the BATTERY DISCONNECT switch on the pilot s circuit breaker sub-panel. The switch is also intended for ground operation in the event a starter relay becomes welded closed. The battery condition may be continuously monitored using the cockpit temperature gage. Battery temperatures should remain well below 63 C (145 F) during all operations. Anytime battery temperature exceeds 63 C (145 F), the red BATT O TEMP annunciator illuminates. If temperature continues to climb and exceeds 71 C (160 F), the red BATT O TEMP > 160 annunciator will flash and trigger the MASTER WARNING annunciator. NOTE The battery must be serviced per the Maintenance Manual when the battery temperature exceeds 63 C (145 F). The emergency lights, if illuminated in emergency operation, will continue to use the airplane battery power until the airplane battery voltage is lower than its own emergency battery pack voltage. Page 1

The three-position control switch for the battery is normally located on pilot s switch panel, and is labeled BATT, OFF and EMER. Placing the switch to the BATT position closes the battery and emergency relays and powers the battery bus, emergency bus and both main DC buses. This position also enables external power to supply the entire system. In the OFF position, battery or external power is isolated from all but the hot battery bus. With the battery switch in the EMER (emergency) position and both generators OFF, a properly charged battery will supply power for approximately 30 minutes to the following equipment: LH and RH Start PCB's LH and RH Ignition COMM 1 NAV 1 AHRS 2 LH Eng Display RMU I Flap Control Two-Position Stabilizer Fwd and Aft Emergency Light Battery Packs Standby Pitot and Static Heaters Pilot s and Copilot s Audio Panels Glare shield and Overhead Floodlights Standby HSI Standby Radio Control Head Interior Entry Lights Landing Gear Control and Indication Hydraulic Control The standby flight display unit will continue to operate on its own emergency battery pack. This battery pack also provides 5 volt emergency instrument lighting. NOTE In some cases, it may be prudent to turn OFF unneeded systems in order to conserve the airplane s battery. APU SYSTEM The onboard auxiliary power unit (APU) generates and provides auxiliary bleed air and auxiliary electric power. Auxiliary bleed air is used for the environmental system and door seals. Auxiliary electric power may be used to power all onboard electrical systems. The APU can provide both auxiliary bleed air and electric power on the ground without the engines running or in the air up to an altitude of 30,000 feet. The Auxiliary Power Unit (APU) electrical system consists of a 300 Amp starter/generator, starter relay, control and monitor PC boards, and associated switches. The APU system is used to provide battery assisted engine starts and ground cooling. STARTER/GENERATORS A starter/generator is located on each engine and is wired directly to the power Junction Box. The starter/generator is driven by engine rotation through the accessory gear box, and is air cooled using engine bypass air. In ground operations (ground idle) each starter/generator is rated at 200 amps (which may be exceeded momentarily for start). At maximum operating altitude, each starter/ generator is rated at 300 amps. Page 2

DIRECT CURRENT SIMPLIFIED SCHEMATIC Figure 2-13 (Sheet 1 of 2) Page 3

DIRECT CURRENT SIMPLIFIED SCHEMATIC Figure 2-13 (Sheet 2) Page 4

GENERATOR CONTROL UNIT (GCU) Two GCUs, one for each starter/generator, are installed in the tailcone area above the aft power junction box. The GCU is used to control the operation of the starter/generator and provides the following control features: 1. Voltage regulation at 28.5 VDC. 2. Load sharing to within 40 amps in parallel operation. 3. Overvoltage protection at 35.0 VDC. 4. Reverse current control of the line contactor. 5. Generator feeder ground fault protection. 6. Start contactor control and field-weakening during start. 7. Overspeed sensing and protection resulting from sheared starter shaft. 8. Generator self-excitation and subsequent regulation without an external source of power (such as a battery). 9. Generator deactivation when the firewall shut-off is activated. EXTERNAL POWER External direct current (DC) power can be connected to the airplane through a receptacle located on the left side of the fuselage. When external power is connected, the external power relay energizes and connects the power source to the hot battery bus. Positioning the battery switch to BATT energizes the battery and emergency relays allowing external power to be connected to the entire DC system. Ground power requirements dictate a 28-volt unit, with a nominal capability of 1000 amperes current. If an adjustable power unit is used, it should be adjusted to provide a setting of 1000 amperes. A ground power unit with a soft start capability is preferable. The battery should be disconnected if the airplane is to be on a ground power unit for a prolonged period of time. DIRECT CURRENT (DC) POWER INDICATORS The indicators consist of two ammeters, a voltmeter and two amber generator failure lights. The ammeters function as load meters indicating the load being carried by each generator. The voltmeter is wired through the battery switch and will indicate the voltage of the hot battery bus any time the battery switch is in the BATT or EMER position. The voltmeter selector switch can be rotated to the LH or RH GEN positions to check generator voltage output. Since the voltmeter reads the highest voltage on the bus, an accurate check of one generator is obtained only with the opposite one off the line. Should either generator fail, the associated power relay will open, removing the generator from the system and illuminating the appropriate L or R GEN OFF annunciator panel light. Should both generators fail, the MASTER WARNING light will also illuminate. This is the only condition under which amber annunciator light illumination will trigger the MASTER WARNING. Page 5

ELECTRICAL BUSSES EMERGENCY BUS AVIONICS BUS GENERATOR BUS ELECTRICAL BUS (continued) AHRS 2 ADC 1 LH GENERATOR LH OIL PRESS AUDIO 1 (only when EMER is selected, otherwise this is on the Avionics Bus) ADC 2 RH GENERATOR RH OIL PRESS AUDIO 2 ADF 1 LH START CONTROL PCB LH PANEL LTS COMM 1 ADF 2 RH START CONTROL PCB RH PANEL LTS & MAP LH START PCB AFIS LH VOLTMETER LTS RH START PCB AHRS 1 RH VOLTMETER PITCH TRIM LH ENGINE DISPLAY AUDIO 1 (WARN) LH PITOT/STATIC FLAP CONTROL AUDIO 2 (WARN) ELECTRICAL BUS RH PITOT/STATIC FLOOD LIGHTS CABIN DISPLAY AHRS AUX BATT PULSE LIGHTS GEAR CONTROL COMM 2 ANTI-COLLISION LTS PWR BRAKES GEAR WARNING DISPLAY CONTROL 1 AOA RUDDER BIAS LH IGNITION DISPLAY CONTROL 2 AOA HEATER SKID CONTROL RH IGNITION DME 1 A/P SERVO SPEED BRAKES NAV 1 DME 2 AUTO TEMP STANDBY (ATT) PWR STAB CONTROL ETAWS BATT TEMP LH START STANDBY HSI FLIGHT PHONE LH BOOST PUMP RH START STANDBY P/S HEATER HF RH BOOST PUMP TAIL DEICE IC 1 CABIN DOOR MONITOR TAS HEATER BATTERY BUS IC 2 CENTER CLOCK LH THRUST AFT EMERG LTS MFD CENTER PNL LTS REVERSER AFT/FWD COMP LTS MFD CONTROL CVR RH THRUST BATTERY DISC RELAY NAV 2 EL PNL/PNL FLD REVERSER BATTERY VOLTAGE PFD 1 EMERG PRESS WARNING LTS 1 CABIN DOOR PFD 2 LH ENGINE ANTI-ICE WARNING LTS 2 ELT (AVN) RAD ALT RH ENGINE ANTI-ICE WING INSPECTION LT FWD EMERG LTS RADAR LH ENG COMP W/S AIR INTERIORS RADAR CONTROL RH ENG COMP LH W/S ANT-ICE LH START CONTROL PCB TCAS RH ENGINE DISPLAY RH W/S ANTI-ICE RH START CONTROL PCB WARN ENGINE VIB MON XPDR 1 LH FIRE DETECT FEED BUS XPDR 2 RH FIRE DETECT LH BUS SENSE FLT HOUR METER RH BUS SENSE CROSSFEED BUS FUEL CONTROL LH LANDING/RECOG LTS COCKPIT WEMAC FAN LH FUEL QTY RH LANDING/RECOG LTS LH IGNITOR SOURCE RH FUEL QTY LH LIMITER RH IGNITOR SOURCE LH F/W SHUTOFF RH LIMITER LH LANDING LTS RH F/W SHUTOFF OXY/SEAT BELT LH LANDING/RECOG LTS GLARESHIELD FANS LH PRECOOLER CONTROL RH PRECOOLER CONTROL TAIL FLOOD LTS MANUAL TEMP NAV NORM PRESS Page 6

LEFT CIRCUIT BREAKER PANEL Figure 2-14 (Sheet 1 of 2) Page 7

RIGHT CIRCUIT BREAKER PANEL Figure 2-14 (Sheet 2) Page 8

ENGINE STARTING Depressing either engine start button closes the respective start relay and provides DC power to the engine starter. Power to close the solenoid start relays and energize ignition comes from the battery bus, requiring the battery switch to be in the BATT position. Automatic ignition sequencing takes place with both engine ignition switches in the NORM position. A white light in each starter button indicates power on the contacts of the respective start relay. The starter operation is terminated when the speed sensor in the generator control unit removes power from the start relay at approximately 38% N2. The automatic start sequence can be terminated at any time by pushing the cockpit START DISG switch located between the start buttons, which will open the start relay and halt the start sequence. During engine start, when the generator output exceeds battery voltage and/or is in parallel with the other generator (within 40 amperes), the starter/ generator reverts to generator operation. The power relay closes and supplies power to the respective DC bus. Current will then flow from either main DC bus through the battery bus, battery relay and hot battery bus, providing battery charging. The APU system also provides battery assisted engine starts. The airplane is equipped with a cross start capability which utilizes the generator of an operating engine to assist starting the second. This is accomplished by both start relays closing when the second start is initiated routing power through the hot battery bus to the other engine. On all cross starts, the operating engine should be set at 52 to 53% N2 to ensure proper torque on the generator shaft. Cross generator start capability is disabled with weight off the left main gear squat switch in order to prevent cross starts in flight. Starts being made with external power may be accomplished with the generator switches in either the ON or OFF position, however, it is recommended that they be turned OFF during the start. If the generator switch is placed in the ON position the generator control unit will automatically initiate the generator mode after engine start. If the generator switch is placed in the OFF position, the generator mode will be initiated by manually placing the generator switch to the ON position. External power is automatically disconnected when either generator is supplying power to the bus. In order to start the second engine by external power, the generator supplying voltage to the bus must be disconnected by placing the generator switch to the OFF position. An overvoltage protection system is provided during use of an external power. The control unit monitors the external power voltage and will de-energize the external power relay if the voltage is above 32.5 volts. External power cannot be reapplied to the airplane until the voltage has been interrupted, after a start termination which has been caused by an overvoltage condition. For battery starts and under all normal flight conditions, the generators are left in the GEN position. CIRCUIT BREAKERS Push-to-reset, pull-off type circuit breakers, with the amperage rating marked on each breaker, are installed in panels located on both sides of the cockpit. The panels are readily accessible to the flight crew during flight. The panels shown are typical installations for the XLS. Additional circuit breakers to which flight crew access is not essential, are located in the tailcone junction boxes. Page 9