PS24/AC Volt AC 16 Amp

Similar documents
Power Supply EL

CX-SERIES ADVANCED BATTERY CHARGER

Phoenix Inverter

Power Supply EL

SN1010 NATURAL VENTILATION CONTROLLER SET POINT

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

JANDS DD-8. Technical Manual. Version 1.0

V1606 3U RACK ENCLOSURE

EMERGENCY VEHICLE BATTERY MANAGER PS2024

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

12/24V 30A AUTOMATIC/MANUAL WORKSHOP BATTERY CHARGER

A6Z OPERATING MANUAL

HQST 500W (12V) HQST 1000W (12V) Modified Sine Wave Inverter. User Manual

100 Watt Power Amp 50 Watts x 50 Watts Single Rack Space

RP-4000 Reserve Power Control

EPS/ELA-Series User Manual EPS/ELA 250W

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

12V 160A/24V 185A MANUAL WORKSHOP BATTERY CHARGER

DKG-114 MANUAL AND REMOTE START UNIT

Installation and Operations Manual

QTFX-F1, QTFX-F2 FLAME EFFECT

12 amp RMS Battery Charger

A3Z OPERATING MANUAL

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

TPM/GMT Panel Installation Guide

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

CX Series User s Manual

MODEL ELC-12/40-CVM-D BATTERY CHARGER

GCU-10. Automatic Engine Control Unit Operators Manual

CCTV Rack Mount Power Supplies

BULL POWER Line Conditioner Regulating Power Bar

PSU EN54-4 Power Supplies

RELAY BOX PRODUCT MANUAL IMPORTANT

CCTV Rack Mount Power Supplies

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

PRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0

DP140e. Installation & Operations Manual

Westell FUSE PANEL. Technical Practice N Position Type VDC Floating

Sentry Battery Charger. Installation and Operations Manual Section 75

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family

RVS-DN Digital Reduced Voltage Motor Starter

FUSE PANEL. Technical Practice N N-L33 10/10 GMT Front Access NEBS Level 3 Certified

FUSE PANEL Technical Practice N N-L34 20/20 GMT (23 panel) NEBS Level 3 Certified

The Powermatic User Guide Test Sieve Shaker

CALTRAP INSTALLATION AND OPERATIONS MANUAL

SCR Power Controllers

R800-16PCPS DUAL REDUNDANT POWER SUPPLY FOR THE R RACK USER MANUAL

Uninterruptible Power System

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

Noran Tel. FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified

ALTERNATOR STARTUP Turning gear to full operation. Procedure initiated by:. 7/03 Before starting procedure, remove all check marks.

TP-BC AC to DC24V UNINTERRUPTED POWER SUPPLY User Manual. DC power output 8A Charge current 7.5A

LED Twister II. User manual UK Version 1.0

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

Installation Instructions

BATTERY SAVER LOW RIPPLE HO

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS

OWNER S MANUAL Please read this manual before operating your power supply

Combined Ventilation Controller RVWS-T-224HA

This Datasheet for the IC670MDL930. Relay 2A 8 Pt. 6 form A/2 form C Isolated.

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Idle Free Systems, Inc. Reference Guide System Component Information

USER MANUAL MPS 1-5KW SERIES

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

A1P OPERATING MANUAL

USER S MANUAL TUBE SEALER. Model SE450. No. CAT.SE45010Ce

Mania EF1 user manual

SAFE & SECURE ACTUATOR PRODUCT MANUAL

Sinergex. PureWatts Elite 150. User's Manual. Sinergex Technologies L.L.C. (USA) Website:

NT-500 Technical Support Guide. For use by qualified company approved Technicians

Type C Track Circuit Uninterruptable Power Supply

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

BENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0

RECHARGEABLE PORTABLE EVAPORATIVE COOLER

Outdoor Enclosure Power System ENC X100MP48F20-AC6

60 Series Engine Controls

Application Engineering

Installing Power Components

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

Installation Instructions

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

RF Point Level Control with Sensor Monitor

AC Anywhere. User Manual. Power Inverter. (Class II product) Please read the installation and operations instructions before using the Power Inverters

Rack Mount Power Supplies

POWER SUPPLIES & RECTIFIERS

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

BENCHTOP INSTRUMENT. Multi-channel DC Power Supply TP2000N/TP2000PU/TP4000N Series Operation Manual V1.0

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

Light Source User Guide

FUSE PANEL Technical Practice FDP /10 GMT NEBS Level 3 Certified

ELECTRICAL PANELS. Chap.

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Transcription:

ALTERNATING CURRENT POWER SUPPLY PS24/AC-6 24 Volt AC 6 Amp FEATURES: Mains Fail Relay Output and Indicator. Fuse blow indication and relay output. 6 fused outlets DESCRIPTION: SPECIFICATIONS: Inputs Voltage- 230 VAC, +/- 0% Frequency- 50 Hz Current- 2020 ma Protection- 5x20mm, 3A Fuse. Outputs Total Power- Voltage- Main O/P Current- Protection: Current- 384 Watts 24 VAC 6 Amp.6 Amp per output. Temperature Operating- 0 C to 50 C Mechanical Mounting- Weight- Dimensions- 4 x 4mm Holes 6.3Kg 430 x 90 x 85 mm Connections Input- IEC Socket Outputs- 2.5mm Removable Rising Clamp. Isolation In/Out- In/Gnd- 5 KV AC sec 5 KV DC Indicators AC Fail- Fuse Fail- Green LED Red LED Accessories Supplied -.5 Meter IEC mains lead Relay Outputs AC Fail- Fuse Fail- Clean A relay contacts Com, N/O, N/C Clean A relay contacts Com, N/O, N/C Upgrades Available -PS RACK KIT

0 PS24/AC-6 0 6 30 30 4 400 2 3 4 5 6 8 9 2 3 4 5 6 85 430

INTRODUCTION: The PS24/AC-6 is designed as part of a professional security camera installation. It can power up to 6 cameras each via a separate protected output, alarm s are pro vided to signal supply or fuse fail. The supply comes as a wall mount module, but with the addition of the PS-RK FRONT the supply transforms into an industry standard 2U 9 Rack Case. All connection are via plug in connectors, including the mains for very fast easy installation. Model Identification Type Label Fuses Serial Number FEATURES: -24 Volt AC Camera supply -6 Individual fused outputs -Each output has fuse fail indicator -AC fail relay -Fuse fail relay -Front panel status LED -All steel platinum finish enclosure -Approved to AS/NZ -Fused IEC main inlet -Made in NZ SPECIFICATIONS: Input = 230VAC 50Hz, 385 watts Output = 24VAC @.6A per output within a total combined load of 6 Amps.

FRONT VIEW OF PS24/AC-6 with PS-RK FRONT (OPTIONAL) Mounting Holes Handle Power ON/OFF Switch Fuse Blown LED Red AC OK LED Green

-COM -NC -NO 5 6 8 3 4 5 6 REAR VIEW OF PS24/AC-6 FUSE BLOWN MAINS FAIL -COM -NO -NC Alarm monitoring relay contacts for AC Fail and Blown Fuse Mains IEC Inlet Mains Fuse 9 0 2 Plug in polarized output connectors 2 3 4 Cover Plate Removal Screw 5 6 Fuse for each output 2 3 4 5 6 8 9 0 2 3 4 Cover Plate Removal Screw Fuse LED The Green LED in the center of each Fuse holder will illuminate if the fuse is blown. Locate the cause of the Trouble (excessive load, cable short, shorted camera) then follow the instructions under: Blown Fuse Replacement.

Rack Installation (requires extra kit) Install the power supply into the Rack, the best location is at top of the Rack as heat will rise trough the top vent cover. If the supply is located at the bottom of a Rack allow at least a U space above it for air flow. 2 Secure the Rack using the 4 x M6 x 20mm No.2 Pozi screws Provided. 3 Determine from the Camera manufactures Data sheet how much current each camera will draw, check that this amount does not exceed 8 Amps or use the Table below. 4 Remove the output plug from the back of the supply, connect the first cameras supply cable to the terminals marked. Repeat for the rest of the cameras, plug the blocks back in. Note only one camera should be connected to each output. As the output is ac, the wires can go either way round 4 cameras connect to each plug in block, the last 2 terminals are unused. 5 Plug in the mains IEC power cord. 6 Switch on the front panel power switch, the green AC OK LED should be on. The red Fuse Fail LED should not be on, if it is there is a blown output fuse, most likely because of a short on one camera supply cable. Look at the 6 fuses on the rear of the rack to see which one is blown (as indicated by it s green LED being on, See fuse changing). Warning *Do Not block or cover the top ventilation holes, or allow to become Blocked with dust. *Do Not Remove the top cover, there are no user or installer serviceable parts inside (fuses are on the rear panel behind the clear cover and in the IEC power connector. *Do Not subject the unit to any moisture or spray, cleaning should be done by vacuuming the vent cover or wiping with a soft Dry cloth. *Do Not use if any part of this power supply is Damaged, Return it to the manufacture. *Do Not use this supply for other than what is intended..8.6.4 Amps pre Output.2 0.8 0.6 0.4 0.2 Series 0 2 3 4 5 6 8 9 023456 Number of Cameras

High Power Outputs If a camera with more than.6 Amps is required to be run from this supply multiple outputs may be linked together. See Diagram below note the maximum load is 6 Amp. 2 3 4 Link every second Terminal 24VAC @ 6.4Amps Blown Fuse Indicator The PS24AC-6 has 6 Fused outputs, the fuses on the rear are located under a clear protective cover. When a fuse is blown a green LED located in the center of it s fuse holder will illuminate, indicating it is blown. On the front panel the Red Blown Fuse indicator will also illuminate. The Blown Fuse relay (form C relay 30VDC @ A) will change over, this can be used to signal a monitoring station. Blown Fuse Replacement - 6 Output Fuses. Note which fuse is blown by the green LED being illuminated. To replace a blown fuse switch the power supply off at the front panel switch. Remove the two center screws holding the clear protective cover in place. Replay the fuse with one of the same type and rating (.6A 250VAC). Refit the clear cover. Blown Fuse Replacement - Mains Fuse Switch off the supply on the front panel and wall supply, remove the IEC inlet connector from the rear of the power supply, remove the fuse carrier below the IEC connector (see page 5) Replace the fuse with the same type (3A 250VAC 5 x 20mm slow blow).

Arrowhead Alarm Products Ltd. Phone 09 44 0085 Fax 09 44 0088 Freephone 0800 00 23 WWW.AAP.CO.NZ 344b Rosedale Rd Albany, Auckland, New Zealand.