Technical Data Sheet FT & FIT-1003 SERIES AIR VOLUME/ VELOCITY TRANSDUCERS. Features DESCRIPTION

Similar documents
FT-1005 Air Volume/Velocity Transducer. Operation & Maintenance Manual. Engineered for accuracy, applicability, durability and simplicity

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

Low Pressure Sensor. Overview. Specifications. Installation and Operation

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

OEM Pressure Transmitters

Figure 1: WPR2 Dimensions and Hardware

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry. Precision Airflow Measurement An ONICON Brand

Installation and Operation Instructions DLP Series

MS4515 SPECIFICATIONS FEATURES APPLICATIONS

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

AD-1251 Probe with Differential Pressure Transducer

MS4525 SPECIFICATIONS

FEATURES AND BENEFITS

EQUIVALENT BASIC CIRCUIT

ELECTRONIC CONTROLLER

QPV1 Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS

V-SENSOR LOW AIR VELOCITY SENSOR

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar B87

FOR USE IN SOLUTION AIR HANDLING UNITS

M3500 Industrial Pressure Transmitter

FAIRCHILD T8001 SERIES STANDARD RANGE MINIATURE TWO-WIRE, P/I PRESSURE TRANSDUCER. Installation, Operation and Maintenance Instructions

Pressure Transmitter

VT-SENSOR AIR VELOCITY AND TEMP

Distributed By: M&M Control Service, Inc PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE #

Industrial Pressure Transmitters

FAIRCHILD T5200 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Compact Low Pressure Sensor

THE INSIDE STORY OF THE QPV OR MPV:

PX409 Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-10 inh2o to psid

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

CCS Zone/Bypass Damper Assembly

MM1/MM2 INSTALLATION & MAINTENANCE INSTRUCTIONS

YCCS Zone/Bypass Damper Assembly

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

YCCS Zone/Bypass Damper Assembly

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Installation. Global Vision Inc Jefferson Hwy - Osseo, MN USA - ph fx

FlowCon Energy FIT System

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

SATRON VDt Differential Pressure Transmitter

Smart Pressure Transmitter

mass flowmeter for compressed air

Fisher 546 Electro Pneumatic Transducer

SSI Technologies Application Note PS-AN2 MediaSensor Absolute & Gage Pressure Transducers & Transmitters Product Overview

Micro-Machined Silicon Transducers

Type Type 1001 Transducers. I/P & E/P Transducers

Type Type I/P & E/P Transducers

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

Installation, Operation and Maintenance Instructions Output Range Part Number Input psi bar Impedance Output Range

Laboratory Room Single Duct Supply Air Terminal

Laboratory Exhaust Air Terminal

Model DCT Digitally Compensated Pressure Transducer

PE-5000 DUCT STATIC PRESSURE SENSING ELEMENT

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

PRESSURE BENCH OPERATING INSTRUCTIONS

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

SSI Technologies Application Note PS-AN4 MediaGauge (Model MG-9V) Digital Pressure Gauge Product Overview

BAS Construction Checklist

SSI Technologies Application Note PS-AN4 MediaGauge (Model MG-9V) Digital Pressure Gauge Product Overview

Data Sheet. I/P and E/P converters. RS stock numbers ,

FE-1000 INSERTION TYPE AIRFLOW SENSING ELEMENT

SPANS AND RANGES. Lower Range Limits 150 in. H 2 O ( 38 kpa) 800 in. H 2 O ( 200 kpa)

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

1100 Series Piston Type Differential Pressure Gauges


Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Beck. The differential pressure transmitter for air with IP65

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

2100 Turbine Flow Sensor

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Pressure transmitters for industrial applications Type MBS 4510

mass flowmeter for compressed air

Fluke 750P Series Pressure Modules

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

OEM Pressure Transmitters

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

Type A-10 General Purpose Pressure Transmitters

SSI Technologies Application Note PS-AN3 MediaGauge Digital Pressure Gauges Product Overview

Model 124 Filter Minder & Model 124

TURCK Inc Campus Drive Minneapolis, MN Application Support: Fax: (763) M2

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

SATRON VTe pressure transmitter

Control Valves Positioner

Control Valves Positioner

Accutrol, LLC Product Sheet AVC6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

Type I/P & E/P Transducers

SSI Technologies MediaSensor

Accutrol, LLC Product Sheet AVC5000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Transcription:

Technical Data Sheet FT & FIT-1003 SERIES AIR VOLUME/ VELOCITY TRANSDUCERS DESCRIPTION FT & FIT-1003 Series transducers include Models FT-1003, FT-1003-ZV, FIT-1003-D, FIT-1003-DZV, FIT-1003-M, and FIT-1003-MZV. FT & FIT-1003 Series are differential pressure transducers with a square root extractor, scaling multiplier, and output filter complete in a single package. The differential pressure transducer sensor operates on the capacitance principal and is capable of sensing ultra low differential (velocity) pressures. In the capacitance cell, a very lightweight, responsive diaphragm deflects a small amount when pressure is applied. This deflection results in a change in capacitance, which is then detected and processed electronically into an output signal linear to the velocity pressure. The electronic signal is then sent to the square root extractor/multiplier, which converts the velocity pressure signal into an analog output linear to velocity (fpm) or volume (cfm). The FIT Series includes local indication of the measured process air velocity and/or volume on either a 0.5 inch high 3-1/2 digit LCD display meter scaled in cfm (indicated by a D in the model number) or an independent front panel mounted magnehelic pressure gauge scaled in both cfm and fpm (indicated by a M in the model number). The independent magnehelic gauge readout allows for quick and immediate verification that the electronic transducer is operating effectively. An optional built-in three-way manual zeroing valve for ease of zero verification and calibration can also be furnished (indicated by a ZV in the model number). Each FT & FIT-1003 Series transducer is selected and factory calibrated to meet the design requirement of the flow measuring element being served. Features Three wire 0-5 VDC output Three wire 0-10 VDC output (optional) ± 1% F.S. accuracy ± 0.5% F.S. accuracy (optional) Square root extractor/multiplier Local indication of flow on a LCD display meter or independent indication of flow on a magnehelic pressure gauge Manual three-way zeroing valve Full scale ranges as low as 1,266 fpm Can be operated continuously in temperature ranges of 32 to 160 o F Can be stored in temperature ranges of -40 to 180 o F Zero shift of only ± 0.025% F.S. per o F Span shift of only ± 0.025% F.S per 0 F 25 psi maximum static line pressure Differential overpressure of 5 psi proof and 25 psi burst Vibration less than 0.05% F.S. temporary effect with 5g s, 0-60 Hz Non-corrosive dry gas pressure media Pneumatic ¼ barb process input connection

FT & FIT-1003 Series Technical Specifications 1. AVAILABLE FULL SCALE RANGES No. Velocity (fpm) 1 1,266 2 2,003 3 2,832 4 3,468 5 4,005 6 5,664 7 6,937 8 8,955 9 12,665 2. PROCESS INPUT FT-1003, FT -1003-ZV, FIT-1003-D, & FIT-1003-DZV Pneumatic ¼ barb FIT-1003-M & FIT-1003-MZV Pneumatic ¼ compression suitable for either hard or soft wall signal tubing 3. ENCLOSURE FT-1003 FR110 polycarbonate FT-1003-ZV, FIT-1003-D, & FIT-1003-DZV Flame retardant ABS plastic FIT-1001-M & FIT-1001-MZV NEMA 1, Aluminum 4. PRESSURE MEDIA Non-corrosive dry gases 5. OPERABLE LINE PRESSURE 25 psi maximum static line pressure 6. DIFFERENTIAL OVERPRESSURE 5 psi proof and 25 psi burst pressure 7. VIBRATION <0.05% F.S. temporary effect with 5g s, 0-60 Hz 8. FULL SCALE ACCURACY DATA AT 70 F Standard Optional Combined accuracy ±1.00% ±0.50% Terminal point nonlinearity ±0.80% ±0.40% Hysteresis ±0.05% ±0.02% Non-repeatability ±0.10% ±0.05% 9. ENVIRONMENTAL ATTRIBUTES Storage -40 ~ 180 F -40 ~ 82 C Operating 32 ~ 160 F 0 ~ 70 C (10-95% R.H. non-condensing) Compensation Range 40 ~ 125 F 4 ~ 52 C Zero shift ±0.025%FS/ F ±0.025%FS/½ C Span shift ±0.025%FS/ F ±0.025%FS/½ C 10. ELECTRICAL INFORMATION Standard Optional Output 0~5 VDC (3 Wire) 0~10 VDC (3 Wire) Supply Power 12 ~ 36 VDC 18 ~ 36 VDC Connections Removable Plug with Screw Terminals Removable Plug with Screw Terminals 11. APPROXIMATE WEIGHT FT-1003 6 OZ FT-1001-ZV, FIT-1001-D & FIT-1001-DZV 1.2 LB FIT-1001-M & FIT-1001-MZV 3 LB 2

FT & FIT-1003 Series Ordering Information -1 3- - Model: Output: Full Scale Range: Accuracy: 2 = 0-5 VDC 3 = 0-10 VDC FT = Flow Transducer FIT = Flow Indicating Transducer Options: ZV = Zero Valve D = Digital Indicating Meter DZV = Digital Indicating Meter and Zeroing Valve M = Magnehelic Pressure Gauge MZV = Magnehelic Pressure Gauge and Zeroing Valve Note: Leave blank if no options are required 1 = 1.0% (STD) 2 = 0.50% (OPT) 1 = 1266 fpm 2 = 2003 fpm 3 = 2832 fpm 4 = 3468 fpm 5 = 4005 fpm 6 = 5664 fpm 7 = 6937 fpm 8 = 8955 fpm 9 = 12665 fpm 0 = Other (Specify) 3

FT-1003 Dimensions 3.60" 3.24" FT-1003 FLOW TRANSDUCER 2.70" Model No: Serial No: Power: Output: F.S. Value: F.E. Served: FT-1003 1605 12-36VDC 25,000CFM AMS-1S 2.25" 3.75" HIGH LOW 1.75" - FT-1003 Field Connections SIG - SUPPLY 12 TO 36 VDC - - RECEIVER 4

FT-1003-ZV Dimensions 3.500" 4.624" FT-1003-ZV FLOW TRANSDUCER WITH ING VALVE TOTAL PRESSURE SERIAL NO: : OUTPUT: F.S.CFM: F.S.IN W.C.: FE SERVED: 1406 18-36VDC 12,000 3.22 AHU-1SF 5.250" 5.776" 2.360" ING VALVE NORMAL STATIC PRESSURE 0.750" 0.650" 1.000" - FT-1003-ZV Field Connections SIG- SUPPLY 12 TO 36 VDC - - RECEIVER 5

FIT-1003-D & FIT-1003-DZV Dimensions 3.500" FIT-1003-D FLOW INDICATING TRANSDUCER 19 9 9 4.624" CFM X 100 MODEL NO: SERIAL NO: : OUTPUT: F.S.CFM: F.S.IN W.C.: FE SERVED: FIT-1003-DZV 1406 18-36VDC 12,000 3.22 AHU-1SF 6.750" 7.276" 2.360" ING VALVE NORMAL TOTAL PRESSURE STATIC PRESSURE 0.750" 0.650" 1.000" - FIT-1003-D & FIT-1003-DZV Field Connections SIG- SUPPLY RECEIVER 12-36 VDC (STD) 0-5 VDC (STD) 18-36 VDC (OPT) - - 0-10 VDC (OPT) 6

FIT-1003-M & FIT-1003-MZV Dimensions 4.875" FABRICATED 0.063 ALUMINUM NEMA 1 ENCLOSURE 10.930" 12.000" 1/2-14 NPT INT PIPE CONDUIT KNOCKOUT 1.200" TOTAL PRESSURE STATIC PRESSURE ING VALVE NORMAL 0.750" 3.000" FIT-1003-MZV FLOW INDICATING TRANSDUCER Model No: Serial No: Power: Output: F.S. Value: F.E. Served: FIT-1003-MZV 1654 12-36VDC 23,000 AHU-1 1.530" 3.100" 4.100" 5.900" MANUAL ING VALVE 1 4 " COMPRESSION FITTING SUITABLE FOR HARD OR SOFT TUBING FIT-1003-M & FIT-1003-MZV Field Connections SUPPLY 12-36 VDC (STD) 18-36 VDC (OPT) - - e: erved: 1003-MZV ING TRANSDUCER FIT-1003-M 1654 12-36VDC 23,000 AHU-1 RECEIVER 0-5 VDC (STD) 0-10 VDC (OPT) - 7

FT & FIT-1003 Series Specification Guide Electronic Transducers 1. Provide individual airflow transducers selected for the required design airflow rate of the primary element served. Each transducer shall be selected for its respective duty. Supply, Exhaust and/or Return Airflow Transducers shall provide analog output signal linear to air volume that are factory set for a full scale value equal to 110% of the maximum design capacity of the airflow measuring element served for variable air volume applications, or 200% of the design operating value for constant volume applications. 2. The transducer(s) shall be solid state electronic type, with infinite output resolution, capable of performing dedicated air volume measurement and indication functions. Microprocessor based transducers with time sharing of multiple square root extractors and/or controllers are not acceptable. 3. Each transducer s output shall not be affected by direction of mounting (attitude) or external vibrations, and shall be furnished with a factory calibrated span that matches the application. 4. Transducer performance shall be equal to or better than the following: Accuracy: 0.5% F.S. (Terminal Point) / 0.35% F.S. (BFSL) Temperature Effects: <0.03% F.S./ F Over-pressure: 5 PSIG Proof / 10 PSIG Burst Response: <0.25 seconds for full span input Noise Filtration: Low Pass Filter, factory set @ 3.2Hz Additional Specifications for Electronic Transducer Options - Zeroing Valve: Each transducer shall be provided with an integral manual zeroing valve to allow for field calibration of the zero reference value without the need for shutting the operating system down. - Digital Indication: Airflow transducers shall be provided with an integral digital indicating meter that shall indicate the measured air volume in units of cubic feet per minute (cfm). - Magnehelic Pressure Gauge: Airflow transducers shall be provided with an integral dual scale indicating meter operating independent of all other control devices. The top scale shall indicate the measured air volume in units of cubic feet per minute (cfm), and the bottom scale shall indicate the air velocity in units of feet per minute (fpm). The meter shall be a differential pressure type that is diaphragm actuated, and is to be flush mounted on the enclosure door. The meter shall be calibrated to an accuracy of ±2% of span (±3% of span for 0.5 inch water column magnehelic gauge or ±4% of span for 0.25 inch water column magnehelic gauge). Labeling 1. An identification label shall be placed on each transducer listing the model number, airflow measuring elements served, full scale value, and identifying tag number. Manufacturer 1. Electronic transducers shall be Paragon Controls Inc. Model [FT-1003] [FT-1003-ZV] [FIT-1003-D] [FIT-1003-DZV] [FIT-1003-M] or [FIT-1003-MZV] or equal as approved by the Design Engineer. 2. Naming of a manufacturer does not automatically constitute acceptance of this standard product nor waive the responsibility of the manufacturer to comply totally with all requirements of the proceeding specification. Paragon Controls Incorporated P.O. Box 99, Forestville, CA 95436 http://www.paragoncontrols.com Phone 707 / 579-1424 Fax 707 / 579-8480 TDS: FT/FIT1003/1207 Copyright 2004