GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Similar documents
Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

VALIADIS S.A. HELLENIC MOTORS

TECHNICAL BULLETIN. Sandvik MB670 Bolter Miners

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2

ANNEX No 1. C 17/05/2006 SGA112B TERMINAL BOX ARRANGEMENT Ex e, Ex na &Ex td V (OPTION 2)

Attachment to Certificate IECEx TUR X Revison 0

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Ex m Solenoid Operator Type 0519

Explosion proof electric motor For Fuel dispensing application. Main characteristic

champion series motors

Modular Explosion Proof Brakes. IECLine rev 0

Zone 1 Linear Range - Installation Guide

Load disconnect switch Series 8146/5-V11

ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION

IECEx Certificate of Conformity

IECEx Certificate of Conformity Annexe

ATEX LABELLING FOR MOTORS AND GEAR UNITS

IECEx Certificate of Conformity

ILED Dorado. User Manual

0CV2. 0CV2 series dust explosion-proof three-phase. asynchronous motor INSTRUCTIONS. Siemens Standard Motors Ltd

Motors and drives for applications in explosive atmospheres

Explosion and flame-proof cast iron electric motors

ILED Aquarius Illuminated Windsock. User Manual

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

List Price. Mult. Sym. C Dim. Single Phase

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

EX-D ENCLOSURES AND DISTRIBUTIONS

IECEx Certificate of Conformity

xplosion Proof Motors hoyermotors.com Explosion Proof

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Terminal Boxes TNCN. Explosion protection Marking

AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY

The filling level sensors are designed in accordance to the following standards

BFG range BFGC range BFN range

BFG range BFGC range BFN range

IECEx Certificate of Conformity

Operating Instructions

IECEx Certificate of Conformity

INTER PLANT STANDARD STEEL INDUSTRY. Corresponding IS does not exist

IECEx Certificate of Conformity Annexe

Terminal Boxes Series 8125

Explosion and flame-proof single phase electric motors

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

CCAI, CCAIF, CCAIF..H

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS

Modular Flameproof Brakes

IECEx Certificate of Conformity

Explosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Hazardous Area Electrical Equipment. TBKF/CBKF Stainless Steel Flat Roof Keyed Terminal Box Zones 1&2, 21&22. Index

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

TRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom

Panelboards & Motor Starters

Flameproof brake motors. Technical data subject to change without notice. BARTEC VARNOST 1

Ex e, ia Junction boxes TNCN. Features

OPERATING INSTRUCTIONS

Aluminium Frame Motors Improved Efficiency EFF2

NEMA explosion-proof AC motors. Individual solutions are our standard

Solenoid coils VACF Type codes

IECEx Certificate of Conformity

Floodlight Range Installation Guide

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS SOLAS LED Luminaire ATEX & IECEx

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

W22 Medium Voltage Motors TEFC - Severe Duty

IECEx Certificate of Conformity

SWE SERIES (IE3) WONDER ELECTRIC MOTOR (S) PTE LTD. Energy Saving Low Noise Environmental Friendly IEC Dimension Low Vibration European Design

MT/T Translated English of Chinese Standard: MT/T COAL INDUSTRY STANDARD

The safety you rely on.

TBKS/CBKS Stainless Steel Sloping Roof Keyed Terminal Box Zones 1&2, 21&22

HAZARDOUS AREA MOTORS

2400 & 1400 Series (XP, XT, XC & XF) Flame Proof Camera Housings & Pan Tilt Units. Installation & Maintenance Instructions

MINING ELECTRIC MOTORS 3KTCR, 4KTCR, 5KTCR

SERVICE AND EXPLOITATION INSTRUCTION MANUAL

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Terminal Boxes in Stainless Steel SLS**.T

Sensor boxes SRBE Key features and product range overview

[ T] THREE-PHASE MOTORS «[32] [33] Three-Phase Motors - Technical Catalogue 1018/10

Dimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250,

Low Voltage 3-Phase Induction Motors. Range 0.18kW to 670kW

Guideline No.: E-03(201806) E-03 MOTORS. Issued date: June 7, China Classification Society

Control and Terminal Box Type A21-**-*****

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

Flameproof Alternators

General Purpose Three Phase Motors TEFC (IP55) High Efficiency. Standard Features

MINING ELECTRIC MOTORS 3KTCR AND 4KTCR

الهيئة السعىدية للمىاصفبت والمقبييس والجىدة Saudi Standards, Metrology and Quality Org (SASO)

BROCHURE. Low voltage motors and drives for applications in explosive atmospheres

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS

PXN12C DXN25C DXN37C MULTI-CONTACT CONNECTORS 10 A TECHNICAL FEATURES

Flameproof Alternator

Wolflite XT Rechargeable LED Handlamp

Flameproof Level Sensor (Flameproof F/S FP)

Transcription:

Reg No: 1999/027771/07 (Pty) Ltd 7 Spanner Rd / PO Box 467 Olifantsfontein 1665 Tel: +27 (11) 316 4601 Fax: +27 (11) 316 5670 E-mail: admin-mgr@explolabs.co.za GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Ex Type Examination Certificate IA CERTIFICATE Date Issued: 11 Jul 2017 *Expiry date: 11 Jul 2020 Page 1 of 9 Issue: 1 Certificate Number: MS-XPL/17.0490 X Equipment: A Range of Induction Flameproof Motors Model / Type: A Range of Induction Flameproof Motors Type W22X of Frame Size 71 to 355 Applicant: Zest WEG Electric (Pty) Ltd PRIVATE BAG X 10011 SANDTON 2146 Manufacturer: WEG Equipamentos Eletricos S.A Serial No: All serial numbers imported between issued- and expire date and all serial numbers covered by a valid report or acceptable product certification mark. Supplied by Zest WEG Electric (Pty) Ltd Identified by Inspection Authority number MS-XPL/17.0490 X And as described in the Explolabs file number XPL/18489/17.0490 is hereby certified "Explosion Protected see general description ", having been examined and inspected in accordance with the relevant requirements of South African Standards. SANS 60079-0: 2012 Ed 5 IEC 60079-0: 2011 Ed 6 SANS 60079-1: 2009 Ed 4 IEC 60079-1: 2007 Ed 6 SANS 60079-7: 2007 Ed 3 IEC 60079-7: 2006 Ed 4 SANS 60079-31: 2009 Ed 1 IEC 60079-31: 2008 Ed 1 Explosive atmospheres Part 0: Equipment General requirements Explosive atmospheres Part 1: Equipment protection by flameproof enclosures d Explosive atmospheres Part 7: Equipment protection by increased safety "e" Explosive atmospheres Part 31: Equipment dust ignition protection by enclosure "t" Protection afforded Equipment Protection Level (EPL) Group Performance of protection Conditions of operation T class or Max Surface Temp ( C) High High Gb Group II Db Group III Suitable for normal operation and frequently occurring disturbances or equipment where faults are normally taken into account Equipment remains functioning in zones 1 and 2 Equipment remains functioning in zones 21 and 22 T4 135ºC T125ºC

1. GENERAL ANNEX TO CERTIFICATE NO MS-XPL/17.0490 X PAGE 2 OF 9 According to certificate IECEx BAS 13.0008X issue no 1 A Range of Induction Motors of Frame Size 71 to 80 Ex d IIC T4 Gb (Ta -55ºC to + 80ºC), Ex tb IIIC T135ºC Db (Ta -55ºC to +80ºC) The range of induction motor of frame size 71 and 80 comprises a stator frame, endshields and main and auxiliary terminal boxes all fabricated from cast iron. The single ended drive shaft has an external cooling fan at the non-drive end. All cover fasteners are grade 8.8/12.9 steel or grade A2/4-70 or 80 stainless steel. The frames are provided with a terminal neck for the main terminal box. A single auxiliary terminal box may be attached to the side of the main terminal box. The motors have rolling element bearings, are foot or flanged mounted for horizontal and vertical use and may be provided with anticondensation heaters rated up to 7.5W. The motors are rated from 220V up to 1100V 50/60Hz or variable frequency up to a maximum of 120Hz when supplied from a type VPWM, CFW09 or CFW11 invertors manufactured by WEG. The motors have a maximum rating as indicated below for use in a maximum ambient temperature of 40ºC when continuously rated for S1 duty and connected to a 3 phase supply having form and symmetry not worse than that defined in IEC 60034-1 and operated within the defined voltage and frequency limits for Zone A. The motors are de-rated in accordance with the manufacturer s instructions for use with variable frequency supplies, a maximum ambient temperature between 40oC and 80oC, altitudes above 1000m, S2 to S9 duty and a service factor of 1.0 to 1.25. The motors can be provided with various seal arrangements and materials for ingress protection IP55, IP65 and IP66 to a maximum temperature of 160oC. Options include a double ended shaft, integral leads, anti-condensation heaters, thermal protectors, and a breather-drain to IECEx CSA 12.0005U. Cable entry holes are provided as specified on the certified drawings for the accommodation of flameproof cable entry devices, with or without the interposition of a flameproof thread adapter. Unused entries are to be fitted with suitable certified flameproof stopping plugs. The cable entry devices, thread adapters and stopping plugs shall be suitable for the equipment, the cable and the conditions of use and shall be certified as Equipment (not a Component) under an EC Type Examination Certificate to Directive 94/9/EC. When used in an explosive dust atmosphere the cable entry devices shall maintain the ingress protection of the enclosure According to certificate IECEx BAS 13.0045X issue no 0 A Range of Induction Motors of Frame Size 90 to 132 Ex d IIC T4 Gb (Ta -55ºC to + 80ºC), Ex de IIC T4 Gb (Ta -55ºC to + 80ºC), Ex tb IIIC T125ºC Db (Ta -55ºC to +80ºC)

ANNEX TO CERTIFICATE NO MS-XPL/17.0490 X PAGE 3 OF 9 The range of induction motor of frame size 90 to 132 comprises a stator frame, endshields and main and auxiliary terminal boxes all fabricated from cast iron. The single ended drive shaft has an external cooling fan at the non-drive end. The terminal box cover fasteners are grade 8.8/12.9 steel or grade A2/4-70 or 80 stainless steel. The frames are provided with a terminal neck for the integral main terminal box. A single auxiliary terminal box may be attached to the side of the main terminal box. The wall between the terminal box and the motor frame is provided with flameproof potted cable bushings for the winding tails and auxiliary cables for thermal sensors etc. The terminal boxes may be designated flameproof Ex d, or increased safety Ex e. The motors have rolling element bearings, are foot or flanged mounted for horizontal and vertical use and may be provided with anti-condensation heaters rated as indicated below. The motors are rated from 220V to 1100V when supplied with an Ex d terminal box, or from 220V to 690V when supplied with an Ex e terminal box, 50/60Hz or variable frequency up to a maximum of 120Hz when supplied from a type VPWM, CFW09 or CFW11 invertors manufactured by WEG. The maximum voltage on the auxiliary terminals is 440V. The motors have a maximum rating as indicated below for use in a maximum ambient temperature of 40oC when continuously rated for S1 duty and connected to a 3 phase supply having form and symmetry not worse than that defined in IEC 60034-1 and operated within the defined voltage and frequency limits for Zone A. Frame Size 90 100 112 132 Maximum output (kw) 3.0 4.0 7.5 11.0 Maximum output (kw) with permanent magnet and VFD 4.5 7.5 11.0 22.0 Poles 2 to 12 Heater (W) 11 11 22 30 The motors are de-rated in accordance with the manufacturer s instructions for use with variable frequency supplies, a maximum ambient temperature between 40oC and 80oC, altitudes above 1000m, S2 to S9 duty and a service factor of 1.0 to 1.25. The motors can be provided with various seal arrangements and materials for ingress protection IP55, IP65 and IP66. Options include permanent magnet, a double ended shaft, integral leads, anti-condensation heaters, thermal protectors, forced ventilation and a breather-drain to IECEx CSA 12.0005U. Cable entry holes are provided as specified on the certified drawings for the accommodation of flameproof cable entry devices, with or without the interposition of a flameproof thread adapter. Unused entries are to be fitted with suitable certified flameproof stopping plugs. The cable entry devices, thread adapters and stopping plugs shall be suitable for the equipment, the cable and the conditions of use and shall be certified as Equipment (not a Component). When used in an explosive dust atmosphere the cable entry devices shall maintain the ingress protection of the enclosure According to certificate IECEx BAS 13.0142X issue No 0 A Range of Induction Motors of Frame Size 160 to 200 Ex d IIC T4 Gb (Ta -55ºC to + 80ºC), Ex de IIC T4 Gb (Ta -55ºC to + 80ºC), Ex tb IIIC T135ºC Db (Ta -55ºC to +80ºC)

ANNEX TO CERTIFICATE NO MS-XPL/17.0490 X PAGE 4 OF 9 The range of induction motor of frame size 160 to 200 comprises a stator frame, endshields and main and auxiliary terminal boxes all manufactured from cast iron. The single ended drive shaft has an external cooling fan at the non-drive end. The terminal box cover fasteners are grade 8.8/12.9 steel or grade A2/4-70 or 80 stainless steel. The frames are provided with a terminal neck for the main terminal box. A single auxiliary terminal box may be attached to the side of the main terminal box. The wall between the terminal box and the motor frame is provided with flameproof potted cable bushings for the winding tails and auxiliary cables for thermal sensors etc. The terminal boxes may be designated flameproof Ex d, increased safety Ex e within the provisions of this report or increased safety terminal boxes as permitted on IECEx BAS 10.0099X. The motors have rolling element bearings, are foot or flanged mounted for horizontal and vertical use and may be provided with anti-condensation heaters rated as indicated below. The motors are rated from 220V to 1140V when supplied with an Ex d terminal box, or from 220V to 690V when supplied with an Ex e terminal box, 50/60Hz or variable frequency up to a maximum of 120Hz when supplied from a type PWM inverter manufactured by WEG or any other inverter having identical parameters affecting the thermal performance of the motor. The maximum voltage on the auxiliary terminals is 440V. The motors have a maximum rating as indicated below for use in a maximum ambient temperature of 40oC when continuously rated for S1 duty and connected to a 3 phase supply having form and symmetry not worse than that defined in IEC 60034-1 and operated within the defined voltage and frequency limits for Zone A. Frame size 160 180 200 Maximum output (kw) 22 30 45 Poles 2 to 12 Heater (W) 30 30 38 The motors are de-rated in accordance with the manufacturer s instructions for use with variable frequency supplies, a maximum ambient temperature between 40oC and 80oC, altitudes above 1000m, S2 to S9 duty and a service factor of 1.0 to 1.25. The motors can be provided with various seal arrangements and materials for ingress protection IP55, IP65 and IP66. Options include a double ended shaft, integral leads, anti-condensation heaters, thermal protectors, forced ventilation and a breather drain to IECEx CSA 12.0005U. Cable entry holes are provided as specified on the certified drawings for the accommodation of flameproof cable entry devices, with or without the interposition of a flameproof thread adapter. Unused entries are to be fitted with suitable certified flameproof stopping plugs. The cable entry devices, thread adapters and stopping plugs shall be suitable for the equipment, the cable and the conditions of use and shall be certified as Equipment (not a Component) under an EC Type Examination Certificate to Directive 94/9/EC. When used in an explosive dust atmosphere the cable entry devices shall maintain the ingress protection of the enclosure. According to certificate IECEx INE 16.0060X Issue No 0. Asynchronous motors of of Frame Size 225 and 250 Ex db IIB or IIC T4 Gb (Ta -55ºC to +80ºC), Ex db eb IIB or IIC T4 Gb (Ta -55ºC to +80ºC), Ex db I Mb, (Ta -55ºC to +80ºC), Ex tb IIIC T125ºC Db (Ta -55ºC to +80ºC)

ANNEX TO CERTIFICATE NO MS-XPL/17.0490 X PAGE 5 OF 9 The three phase Asynchronous motor type W22X, frame size 225 and 250, is composed by frame, endshields, terminal box and auxiliary terminal box and it has Ex db or Ex db eb types of protection for gases and Ex tb type of protection for dusts. The motor is made from cast iron minimum quality FC200, the frame has a neck where the main terminal box is connected, a single auxiliary terminal box may be connected on the side of the main box. The main and auxiliary terminal boxes may be protected by flameproof db type of protection or increased safety "eb" type of protection. Allowed fasteners for terminal boxes are 8.8 or 12.9 quality steel screws or A2/A4-70/80 quality stainless steel screws. Between frame and terminal boxes a flameproof bushing is foreseen. The motors may in addition be fitted with temperature sensors, anti-condensation heaters vibration sensors and breather-drain device Ex certified. Motors could be fed by inverter, a safety thermal probe shall be fitted in the windings to ensure a maximum T4 temperature class of the motor. Different methods of cooling can be used as TEFC, TEBC, TEAO and TENV; an external fan can be installed. The motors get different degrees of protection from IP55 to IP66. Motor can be mounted horizontally or vertically, for vertical use a cowl for the fan is provided. According to certificate IECEx INE 16.0044X A Range of Induction Motors frame size 280 to 355 Ex db IIB or IIC T4 Gb, Ex db eb IIB or IIC T4 Gb, Ex db I Mb, Ex tb IIIC T125ºC Db T amb : -20ºC up to +80ºC for frame size 315 and 355 (for gas) T amb : -55ºC up to +80ºC for frame size 280 (for gas) T amb : -55ºC up to +80ºC (for dusts) The three phase induction cage motors of frame size 280 to 355 are constructed from cast iron for the frame, terminal box, auxiliary terminal box and endshields. Various methods of cooling are used including TEFC, TEBC, TEAO and TENV. External fans are built from metallic and nonmetallic material depending on service temperature. The fan cover is built from Aluminium, Steel, Stainless Steel and Cast Iron. The terminal box fasteners are grade 8.8/12.9 steel or grade A2/4-70 or 80 Stainless Steel. The frames are provided with a terminal neck for the main terminal box. A single auxiliary terminal box may be attached to the side of the main terminal box. The wall between the terminal box and the motor frame is provided with flameproof potted cable bushings for the winding tails and auxiliary cables for thermal sensors etc. The motors have rolling element bearings, are foot or flanged mounted for horizontal and vertical use and may be provided with anti-condensation heaters rated as indicated below. The motors are rated from 220V to 1140V when supplied with an Ex d terminal box, or from 220V to 690V when supplied with an Ex e terminal box, 50/60Hz or variable frequency up to a maximum of 120Hz when supplied from a type PWM inverter manufactured by WEG or any other inverter having identical parameters affecting the thermal performance of the motor. The maximum voltage on the auxiliary terminals is 440V. The motors have a maximum rating as indicated below for use in a maximum ambient temperature of 40 C when continuously rated for S1 duty and connected to a 3 phase supply having form and

ANNEX TO CERTIFICATE NO MS-XPL/17.0490 X PAGE 6 OF 9 symmetry not worse than that defined in IEC 60034-1 and operated within the defined voltage and frequency limits for Zone A. Frame size Maximum output (kw) Poles 2 to 12 Heater (W) 280 315 355 150 345 440 140 140 174 The motors may be de-rated in accordance with the manufacturer s instructions for use with variable frequency supplies, a maximum ambient temperature between 40 C and 80 C, altitudes above 1000m, S2 to S9 duty and a service factor of 1.0 to 1.25. The motors can be provided with various seal arrangements and materials for ingress protection IP55, IP65 and IP66. Options include a double ended shaft, integral leads, anti-condensation heaters, thermal protectors, forced ventilation and a breather-drain to IECEx CSA 12.0005U. The motors may be alternatively marked for gas groups IIA, I, dust groups IIIB, IIIA, temperature classifications of T3 and T2 without an increase in ambient temperature above 80 C, temperature classifications of T5, and T6 Ta=40 C, ingress protection IP5X, IP6X, gas only or dust only. 2. ROUTINE EXAMINATIONS AND TESTS In accordance with clause 16.1 of the IEC 60079-1 standard, each sample defined above has to pass, before delivery, an overpressure test of a period comprised between 10 and 60 seconds under:

ANNEX TO CERTIFICATE NO MS-XPL/17.0490 X PAGE 7 OF 9 In accordance with 16.2 of the IEC 60079-1 standard, the main and auxiliary terminal boxes are exempted from routine tests due to the fact that the boxes underwent to an overpressure test at 61.2 bar, 4 times the reference pressure, with positive results. In accordance with clause 7.1 of the IEC 60079-7 standard, the main and auxiliary terminal boxes protected by increased safety shall successfully pass, before delivery, a dielectric strength test on each of the different circuits of the connection units, performed according to the relevant standards, the supply voltage shall be applied during one minute. (*) Not concerned by the major technical changes of the last edition of the standard.

ANNEX TO CERTIFICATE NO MS-XPL/17.0490 X PAGE 8 OF 9 3. INSTALLATION INSTRUCTIONS It is the manufacturer s responsibility to supply installation instructions with each unit offered for sale as required by IEC/SANS 60079-0 Clause 30. 4. SPECIAL CONDITIONS FOR SAFE USE (denoted by X after certificate number) Special conditions for safe used of motor frame size 71 to 200 The flamepath gaps are less that those permitted by IEC60079-1 for gas group IIC and shall not be enlarged in service. The motors may be provided with integral leads, which must be suitably protected and terminated within an enclosure suitable for the conditions of use. When provided with a breather-drain to IECEx CSA 12.0005U the motors are excluded from Group I, and are limited to temperature classification T5 to T2 Ta -55 C to + 50 C, or T4 to T2 Ta -55 C to + 80 C, and have an IP rating of IP6X. The maximum surface temperature was determined without a dust layer. The end user shall prevent a dust layer forming on the motors. After de-energising a delay 60 minutes is required before opening. Special conditions for safe used of motor frame size 225 to 355 The motors may be provided with integral leads, which must be suitably protected and terminated within an enclosure suitable for the conditions of use. The maximum surface temperature was determined without a dust layer. The end user shall prevent a dust layer forming on the motors. The width of the different flameproof joints is greater than the value specified in the tables of IEC 60079-1 standard. The depth engagement of the flameproof threaded joints is greater than the value specified in the tables of IEC 60079-1 standard The gap of the different flameproof joints is lower than the value specified in the tables of IEC 60079-1 standard. The yield stress of the fastener elements of the flameproof terminal boxes must be equal to class 8.8 or 12.9 or stainless steel A2-70/80 or A4-70/80. Based on the following documentation: IECEx BAS 13.0142X issue No 0,IECEx BAS 13.0045X issue No 0, IECEx INE 16.0060X, IECEx INE 16.0060X Issue No 0 and IECEx BAS 13.0008X 5. CONDITIONS OF CERTIFICATION All production units must be covered by a QAN (Quality Assurance Notification), Product Mark Scheme or batch evaluation.

ANNEX TO CERTIFICATE NO MS-XPL/17.0490 X PAGE 9 OF 9 6. MARKING The following (or similar) information have to be clearly and permanently marked on all units: Supplier : Zest WEG Electric (Pty) Ltd Manufacturer : WEG Equipamentos Eletricos S.A Equipment : A Range of Induction Flameproof Motors Model/Type : A Range of Induction Flameproof Motors Type W22X of Frame Size 71 to 355 Serial No. : --- Ex Rating : see general description IA Certificate No : MS-XPL/17.0490 X This certification indicates compliance with R10.1 of the Mines Health and Safety Act and/or EMR 9(2) of the Occupational Health and Safety Act, provided that the apparatus is used as relevant in accordance with: i) SANS 10086 and IEC/SANS 61241-14 requirements as applicable; ii) Any conditions mentioned in the above report; iii) Any relevant requirements and codes of practice enforced in terms of the Mine Health and Safety Act or Occupational Health and Safety Act; and iv) Any restrictions and conditions enforced by the Chief Inspector of Mines or the Principal Inspector or the Chief Inspector: Occupational Health and Safety. v) A revision certificate replaces all previous version of the certificate. vi) vii) * - Only covers equipment Imported between the Issued and Expire dates. If and when your QAN (Quality Assurance Notification) Certificate for your equipment manufacturer expires during the valid period of the IA Certification (issued for your equipment) and a new certificate is not submitted the existing IA Certification will then be cancelled. It is thus the client s responsibility to always submit the updated and valid QAN certificate(s) to Explolabs (Pty) Ltd. Responsible Testing Officer: Reviewed by: D Maree Senior Testing Officer H De Wet Testing Officer EXPLOLABS EXPLOSION PREVENTION SERVICES This report/certificate shall not be reproduced except in full without the written approval of the company Explolabs (Pty) Ltd shall not be liable for any losses or damages sustained on account of any failure or omission to properly perform our duties in terms of any contract undertaken by us. This disclaimer is immutable and automatically incorporated in any contract undertaken by us; notwithstanding anything to the contrary, save for the express written waiver of our managing director. By marking the equipment in accordance with the documentation/standard, the manufacturer attests on his own responsibility that the equipment has been constructed in accordance with the applicable requirements of the relevant standards and that the routine verifications and tests have been successfully completed and that the product complies with the documentation and standard(s). The contents of electronic reports/certificates cannot be guaranteed. Original certification documents will be kept on file at Explolabs (Pty) Ltd