Reverse power relay and protection assemblies

Similar documents
Multi-purpose percentage restraint differential protection

Breaker failure relay REB 010

Breaker-failure protection RAICA

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

A21M. Introduction: Functional Overview: Key Protection & Control Functions:

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Auxiliary Relay. Type RXP8n, RXPQ8n

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

XM1 - Motor protection relay

Surface mounting, flush mounting, and DIN track mounting

Protection and control VIP30, VIP35. Relays technical manual

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Bistable Relay. Types PSU6n, PSU14n. Station Automation & Protection. ABB Substation Automation Products

Auxiliary Relay. Type CV2

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Test report. Type VRLTC load tap changer VRLTC 1500A Type test summary report

Bistable Relay. Types PSU6n, PSU14n.

3TM Vacuum Contactors

Short form catalogue. Motor protection & control

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

MCD 200 Series Soft Starters

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Summary of Revision, IEEE C , Guide for Breaker Failure Protection of Power Circuit Breakers

34 th Hands-On Relay School

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Slim P.C.B. Relays (EMR or SSR) A

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

PSW102 type CT powered protection unit

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

ADDITIONAL INFORMATION. BE1-50/51B SELF POWERED TIME OVERCURRENT RELAY and RETROFIT KITS. FEATURES and APPLICATION Page 2

Description. Positive safety relays

AE 9... AE 40 Contactors NE... Contactor Relays

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B. Station Automation & Protection. ABB Substation Automation Products

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Auxiliary Relay. Type P8n, PQ8n, PN8n

KD LV Motor Protection Relay

MasterINTERFACE 39 Series - Relay interface modules

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

10V. the rack of the oil pump must be on the

cor Long Run Experience

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

DEVICE STATE/BYPASSED FAILURE OVERLOAD

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Specification for 70mm pole pitch Air circuit breaker up to 1600 A


xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

Type SOQ Negative Sequence Time Overcurrent Relay

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

DX³ RCCBs - ID 4P up to 100 A

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

Motor-drive mechanism, type BUL. Technical guide

Model Number Structure

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

Technical Data Accessories MCBs Ex9B.

Outdoor vacuum breaker for railway applications - FSK II

Power Electronics. Motor brake relay GA 9031 ministop

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

Thermal Overcurrent Circuit Breaker 3120-F...

Electrical network protection VIP30, VIP35. User s manual 12/2008

Functions provided by measuring relays in railway equipment

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Unit Protection System for Pumped-Storage Power Stations

Air-insulated switchgear UniGear type ZS1

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B

SIRIUS 3RU2 Thermal Overload Relays

Star Series Motor protection & control

Thermal Overcurrent Circuit Breaker 3120-F...

2 pole, 10 A AC/DC supply non polarized Plug-in for use with 94 series sockets

Electronic circuit breaker EBU10-T

Thermal Overcurrent Circuit Breaker 3120-F...

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

IBC control. MicroMax MANUAL. With adjustable boost function and threshold value. Since Set of EMC-glands as an option

Synergy EN product information

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

Electronic timers CT-S range Function diagrams

Technical Information

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

Vmax Medium voltage vacuum circuit-breakers. IEC: kv; A; ka ANSI: kv; A; ka

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

AF series contactors (9 2650)

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

Electronic timers CT-E range Selection and ordering details

Thermal Overcurrent Circuit Breaker 3120-F...

DPX moulded case circuit breakers

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Protection Equipment

Transcription:

Reverse power relay and protection Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE980053) (SE980054) Features Micro-processor based time directionalcurrent relay/protection with continuous settings for operate values and time delays. RXPPK 2H is used to detect reverse power or low forward power to prevent damage of the prime mover. Setting range I α = 0,3-15 % of rated current. Two variants, with wide setting ranges. - Scale constant I s = 0,1, 0,4, 0,7, 1,0 A or I s = 0,5, 2,0, 3,5, 5,0 A Two different definite time delay stages. - Trip t 1 = 0-4 s or Trip t 2 = 0-30 s Trip t 2 function is supported with a stand by time-hold function, with the settings 0 or 5 s. When a Start I s has occurred, the t 2 timer will not reset until the hold time has expired, regardless if the Start I s has been reset. Block functions: - Undervoltage block: blocking all the functions if the voltage is less than 40 V - Undercurrent block: blocking all the functions if the current is less than 0,25 % of the rated current Application The purpose of the reverse power relay is basically to prevent damage of the prime mover (turbine or motor) upon a reverse power condition. If the driving torque becomes less than the total losses in the generator and the prime mover, the generator starts to work as a synchronous compensator, taking necessary active power from the network. In case of steam turbines, a reduction of the steam flow reduces the cooling effect of the turbines blades and overheating may occur. Hydro turbines of the Kaplan type and bulb type may also be damaged due to the fact that the turbine blade surf on the water and set up an axial pressure on the bearing. Diesel engines may be damaged due to insufficient lubrication.

Page 2 Application (cont d) The total losses at rated speed, as a percentage of the rated power of the generator, are approximately: Type Total loss Steam turbine 1-3% Hydraulic turbine 1-3% Gas turbine 5% Diesel engine 25% These table values apply to the case when the power input to the prime mover is completely cut off. Thus, in the case when the total power losses of a unit are covered partly by the prime mover and partly by electrical power from the system, the actual power drawn by a generator, during certain motoring conditions, may be much less than the above percentage values. The generator currents remains balanced when the machine is working as a motor, hence, a single-pole relay is fully sufficient if the sensitivity is high. For large turbo units, an additional relay may be connected to a different phase in order to obtain redundancy. When the generator is working as a motor, the small active current to the machine may be combined with a substantial reactive current delivered by the machine. Hence, the angular error of voltage and current transformers feeding low set reverse power relays should be small. For large turbo-generators, where the reverse power may be substantially less than one percent, reverse power protection is obtained by a minimum power relay, which normally is set to trip the machine when the active power output is less than one percent of rated value, low forward power principle (see Fig. 2) The time step t 1 is mainly arranged to trip the field and the generator breaker with a short time delay, typically 2-3 seconds after operation of the reverse power measuring function. The reverse power function with time step t 1 can be used in the normal decommissioning routine to avoid excessive overspeeding when taking steam powered generators off service. The function can also be used to interlock the generator breaker tripping for non-urgent faults. The purpose of the second stage is to prevent excessively high temperature and possible mechanical damage to the prime mover. The time delay can be longer in this case, typically 10-15 seconds. A reset delay, of 5 seconds can be activated to ensure operation, even if power swing makes the current function pick up and reset during the measuring period. A rather common arrangement in older power plants is the use of V-connected voltage transformers. The VT s then have no neutral point available. Polarizing voltage to a RXPPK 2H relay, measuring the current in L1, can be arranged with two 2200 Ω, 2 W resistors shown in Fig. 1. E.g. two RTXE can be used, each with 2200 Ω, ordering number RK 741 225-DG. L3 Fig. 1 R L1 V M R V L1 -V M L2 Voltage V L1 - V M is obtained using resistors for polarizing RXPPK 2H when measuring current in L1. The figure shows V- connected voltage transformers connected between L1 and L2 and L3 and L1 respectively. The difference in resistance value between the two resistors should be kept as low as 10 ohms in order not to introduce appreciable angular errors if the operate value of RXPPK 2H is set to 1% of rated generator current or lower. (98000028)

Page 3 Design The reverse power relay protection with RXPPK 2H can be delivered with different output circuits. The RXPPK 2H relay requires a separate dcdc converter for auxiliary supply (±24 V). One RXTUG converter can supply up to nine relays. Note: Before the RXPPK 2H relay or the dcdc converter RXTUG is plugged into or withdrawn from a terminal base, the auxiliary voltage supply must be interrupted. It is not allowed to disconnect the wiring on the plus or minus supply with the unit in service, since this may result in an unwanted relay operation. RXPPK 2H measuring relay RXPPK 2H is a microprocessor based relay with one measuring stage and two different definite time delay stages. The relay has two input transformers for current and voltages, filter circuits, HMI, LEDs for start, trip indications and three output units which provide separate change-over contacts for start and trip functions. The relay has also two binary inputs, one for reset of LED s and the other to block or enable the trip t 1 function. Operate values are set with the potentiometers and programming switches. Both time delay stages can independently be programmed for the different times. The start function output is energized immediately after the measured value exceeds or falls below the set start level, depending on setting for reverse (over) power or low forward (under) power operation. Technical data Below data is for measuring relay RXPPK 2H. Technical data for the total please refer to the catalogues for other included relays Table 1: Current input Rated voltage U r Rated current I r Scale constant I s for 1A variant 5A variant Effective voltage range Effective current range Voltage block level The function is blocked and the start is reset when the current is: Rated frequency f r Operating frequency range Power consumption for: U = U r = 100 V 1A variant I = I r 5A variant I = I r Overload capacity voltage circuit: continuously during 10 s Overload capacity current circuit: 1A variant continuously during 1 s 5A variant continuously during 1 s 120 V 1A or 5A 0,1, 0,4, 0,7 and 1,0 A 0,5, 2, 3,5 and 5A (0,4-2,5) x U r (0,003-1,70) x I r U < 0,4 x U r 0,3% of I r 50 Hz or 60 Hz 45-66 Hz 0,2 VA 100 mva 150 mva 250 V 300 V 4 A 100 A 20 A 350 A

Page 4 Technical data (cont d) Table 2: Power functions Function Power functions I α > / I α < Function characteristic selectable in the front between: I α >: Reverse power function I α <: Low forward power function I x cos(ϕ-β-α) set I α > see Fig. 2 (α = 180 ) I x cos(ϕ-β α) set I α <(α = 0 ) Setting range I α Setting range β (adjustment for correction of system angle inaccuracy) Consistency of set operate value 0,3-15% of I r ±3 <5% for current <0,02 x I r <2% for current >0,02 x I r Phase angle ϕ consistency <0,5 Angle ϕ between U and I Positive if I lags U Typical operate time I = 0 => 2 x set operate value 100 ms Typical reset time I = 2 => 0 x set operate value 100 ms Typical reset ratio 80% Frequency dependence within frequency ±5% of rated frequency ±10% of rated frequency <0,8 <1,5 Temperature dependence within range -5 C to +55 C <0,5 Binary input 1, selectable in the front between: Block Enable Active signal blocking Trip t 1 function Active signal enables Trip t 1 function Table 3: Time functions Time function Trip t 1 Trip t 2 Time delay Definite time Setting range 0-4 s 0-30 s Accuracy 1% and ±20 ms Reset delay, t h (for function at power swing) - 0-5 s Table 4: Auxiliary DC voltage supply Auxiliary voltage EL for RXTUG 22H Auxiliary voltage for the relay Power consumption at RXTUG 22H input 24-250 V before operation after operation without RXTUG 22H ±24 V before operation after operation 24-250 V DC, ±20% ±24 V (from RXTUG 22H) max. 5,5 W max. 6,5 W max. 3,0 W max. 4,0 W

Page 5 Table 5: Binary input Binary input voltage RL 48-60 V and 110-220 V DC, -20% to +10% Power consumption 48-60 V 110-220 V Max. 0,3 W / input Max. 1,5 W / input Table 6: Output relays Contacts Maximum system voltage Current carrying capacity continuous during 1 s Making capacity at inductive load with L/R >10 ms during 200 ms during 1 s Breaking capacity AC, max. 250 V, cos ϕ > 0,4 DC, with L/R < 40 ms 48 V 110 V 220 V 250 V 3 change-over 250 V AC / DC 5 A 15 A 30 A 10 A 8 A 1 A 0,4 A 0,2 A 0,15 A Table 7: Electromagnetic compatibility (EMC), immunity tests All tests are performed together with the DC/DC-converter, RXTUG 22H Test Severity Standard Surge 1 and 2 kv, normal service 2 and 4 kv, withstand test IEC 61000-4-5, class 3 IEC 61000-4-5, class 4 AC injection 500 V, AC SS 436 15 03, PL 4 Power frequency magnetic field 1000 A/m IEC 61000-4-8 1 MHz burst 2,5 kv IEC 60255-22-1, class 3 Spark 4-8 kv SS 436 15 03, PL 4 Fast transient 4 kv IEC 60255-22-4, class 4 Electrostatic discharge In normal service with cover on 8 kv (contact) 15 kv (air) 8 kv, indirect application IEC 60255-22-2, class 4 IEC 60255-22-2, class 4 IEC 61000-4-2, class 4 Radiated electromagnetic field 10 V/m, 80-1000 MHz IEC 61000-4-3, Level 3 Radiated pulse electromagnetic field test 10 V/m, 900 MHz ENV 50204 Conducted electromagnetic 10 V, 0,15-80 MHz IEC 61000-4-6, Level 3 Interruptions in auxiliary voltage 24 V DC, no resetting for interruptions 110 V DC, no resetting for interruptions 250 V DC, no resetting for interruptions 2-200 ms < 20 ms < 50 ms < 250 ms IEC 60255-11

Page 6 Technical data (cont d) Table 8: Electromagnetic compatibility (EMC), emission tests Test Severity Standard Conducted 0,15-30 MHz, class A EN 50081-2 Radiated 30-1000 MHz, class A EN 50081-2 Table 9: Insulation tests Test Severity Standard Dielectric Current circuit to circuit and current circuit to earth Circuit to circuit and circuit to earth Over open contact 2,5 kv AC, 1 min 2,0 kv AC, 1 min 1,0 kv AC, 1 min IEC 60255-5 Impulse voltage 5 kv, 1,2/50 µs, 0,5 J IEC 60255-5 Insulation resistance > 100 MΩ at 500 V DC IEC 60255-5 Table 10: Mechanical tests Test Severity Standard Vibration Response: 2,0 g, 10-150-10 Hz IEC 60255-21-1, class 2 Endurance: 2,0 g, 10-150-10 Hz, 20 sweeps Shock Response: 5 g, 11 ms, 3 pulses Withstand: 15 g, 11 ms, 3 pulses IEC 60255-21-2, class 1 Bump Withstand: 10 g, 16 ms, 1000 pulses IEC 60255-21-2, class 1 Seismic X axis: 3,0 g, 1-35-1 Hz IEC 60255-21-3, class 2, Y axis: 3,0 g, 1-35-1 Hz extended (Method A) Z axis: 2,0 g, 1-35-1 Hz Table 11: Temperature range Storage Permitted ambient temperature -20 C to +70 C -5 C to +55 C Table 12: Weight and dimensions Equipment Weight Height Width RXPPK 2H without RXTUG 22H 0,7 kg 4U 6C I I ϕ I s α = 180 U pol ϕ I s α = 0 U pol dip switch S1:1=I>. dip switch S1:1=I<. Fig. 2 Functional characteristics for the RXPPK 2H relay

Page 7 Diagrams 110...220V 111 BIN 1 BIN 2 121 110...220V (98000025) RL 48...60V 112 122 48...60V RL 0V 113 123 0V Iα 324 120V 313 315 314 325 0V Ur Iα t 1 331 Ir 316 317 318 341 0A Ir Iα t 2 326 327 328 114 115 116 117 +24V 0 V -24V Fig. 3 Terminal diagram RXPPK 2H Fig. 4 Terminal diagram 001 058-EAA

Page 8 Protection protection are built up based upon reverse power relay RXPPK 2H. Test device RXTP 18 and dc/dc-converter RXTUG 22H can also be included for specific application requirements. Test device RTXP is a tool for relay testing. DC/DC-converter RXTUG 22H can be used either separately for a single protection or to feed also other protections with up to 9 units of the same relay family. With RXTUG 22H all requirements concerning disturbance emission and immunity with this protection assembly will be met. The have output contacts as specified for the relay RXPPK 2H, which in most cases are fully sufficient even for trip duty. Protection are also available with heavy duty output relay RXME 18 (RK 221 825-XX) with indicating flag and can upon request be completed with an output logic of free choice. Output relays are connected to separate auxiliary voltage. The extremely flexible mounting system COMBIFLEX together with a modern CADsystem enables us to present a unique flexibility for designing upon the customers requests. The interface voltage for enable or block impulses can be connected to either 48-60 V dc or 110-220 V dc by connecting the voltage circuit to separate terminals. At delivery all relays are connected for 110-220 V dc. 1 Reverse Power Protection 101 107 101 107 101 107 113 101 107 113 119 319 101 RTXP 18 101 RXTUG 22H 101 RTXP 18 101 RTXP 18 107 RXPPK 2H 107 RXPPK 2H 107 RXTUG 22H 107 RXTUG 22H 113 RXPPK 2H 113 RXPPK 2H 119 RXME 18 319 RXME 18 Order No. Circuit diagram Order No. Circuit diagram Order No. Circuit diagram Order No. Circuit diagram 001 057-BA 001 058-BA 001 057-CA 001 058-CA 001 057-DA 001 058-DA 001 057-EA 001 058-EA Mounting alternatives All can be delivered in the following mounting alternatives: - on apparatus bar - in equipment frame 60C - in RHGS - in RHGX

Page 9 Ordering Specify (Protection): Quantity Ordering number Code A, H, M Desired wording on the lower half of the test switch face plate max. 13 lines with 14 characters per line Specify RXPPK (Loose Relay): Quantity Ordering number Reverse Power Relay Type Voltage Frequency Article No. Code RXPPK 2H 1 A 50 Hz 001 615-AA A1 RXPPK 2H 5 A 50 Hz 001 615-BA A3 RXPPK 2H 1 A 60 Hz 001 615-CA A2 RXPPK 2H 5 A 60 Hz 001 615-DA A4 Auxiliary voltage For included auxiliary relays Code 24 V dc H5 48-55 V dc H6 110-125 V dc H7 220-250 V dc H8 Mounting Mounting alternatives Size Article No. Code Apparatus bars M10 Equipment frame without door 4U 19 000 137-GA M11 Equipment frame with door 4U 19 000 137-KA M12 RHGX 4 4U 12C RK 927 001-AB M71 RHGX 8 4U 24C RK 927 002-AB M72 RHGX 12 4U 36C RK 927 003-AB M73 RHGX 20 4U 60C RK 927 004-AB M74 RHGS 30 6U x 1/1 19 rack 000 315-A M81 RHGS 12 6U x 1/2 19 rack 000 315-B M82 RHGS 6 6U x 1/4 19 rack 000 315-C M83 References Connection and installation components in COMBIFLEX Relay accessories COMBIFLEX User s Guide RXPPK 2H 513 003-BEN 513 004-BEN 509 042-UEN

Page 10 Manufacturer ABB Automation Products AB Substation Automation Division SE-721 59 Västerås Sweden Tel: +46 (0) 21 34 20 00 Fax: +46 (0) 21 14 69 18