Backfeed, Safety, and Work Practices

Similar documents
Minnesota Dept. of Commerce, Division of Energy Resources. Distributed Generation Workshop Interconnection Standards

GUIDE FOR MICROGENERATION INTERCONNECTION TO CITY OF MEDICINE HAT ELECTRIC DISTRIBUTION SYSTEM

Health & Safety Issues Associated with Solar Photovoltaic (PV)

2000 Cooper Bussmann, Inc. Page 1 of 9 10/04/00

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

Design considerations for generator set mounted paralleling breakers

Technical Requirements for Renewable Energy Power System

Service Entrance Methods

Summary of General Technical Requirements for the Interconnection of Distributed Generation (DG) to PG&E s Distribution System

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

ENGINEERING SPECIFICATION

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

Overcurrent Protection According to the 2011 NEC

Definitions. Scope. Customer Generation Interconnection Requirements

Arc flash solutions catalogue Australia. Safety solutions - Protecting employees and the enterprise

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

PV Grid Integration Research in the U.S.

Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards

PSNH INTERCONNECTION REQUEST

Safety Working with LV Drives

Overcurrent Protection (2014 NEC) (Homestudy)

Net Metering Interconnection Requirements

Comments on the Solar Alliance Proposal for Changes to New Jersey Interconnection Rules

Net Metering Interconnection Requirements. Customer Generation Capacity Not Exceeding 100 kw. Date: Version: 1

Non-Beam Hazard - Electricity

Renewable Energy Systems 14

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

Load Side PV Connections

2016 Photovoltaic Solar System Plan Review List

ECET 211 Electric Machines & Controls Lecture 1-3 (Part 2) Electrical Safety in the Workplace Electrical Safety in the Workplace

Surface Regulations and Policies

GP/GPA GROUND FAULT PROTECTION

Power Quality and Protective Device Coordination: Problems & Solutions Part 1 Undersizing of Utility Main Service Transformers

Electrical Safety. Introduction

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS

ELECTRIC SERVICE REQUIREMENTS FOR MEDIUM-SIZED COMMERCIAL INTERCONNECTED DISTRIBUTED GENERATION SOURCES

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

3.0 Radial Distribution Systems

Transformer Protection

STATE OF NORTH DAKOTA DISTRIBUTED GENERATION INTERCONNECTION REQUIREMENTS TABLE OF CONTENTS

the National PhotoVoltaic protection note 5 I rated Introduction points of interest When to Fuse, When Not to Fuse

Electrical Safety For Everyone. Leader s Guide

Document Requirements for Engineering Review- PV Systems v1.1 12/6/2018

Renewable Grid Integration Research in the U.S.

Photovoltaic Solar Plan Review

TECHNICAL SPECIFICATION FOR INDEPENDENT POWER PRODUCERS. NB Power Customer Service and Distribution. June 2008

Bulletin Interconnection of electric power production sources Rules 2-010, , , , , , and

Document Requirements for Engineering Review PV Systems v1.0 6/9/2017

Improving DER Interconnection with Updated Standards and Codes, Smart Inverters, and Distribution System Design

RULE 21 GENERATING FACILITY INTERCONNECTION APPLICATION SMUD s Distribution System - (SMUD FORM 2655)

CIS-IEEE 2017 Conference Renewable Energy Session Renewable Energy s Impact of Power Systems

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.

Building Operator Certification Level I

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

Overview of State Distributed Generation Interconnection Rules

Advanced Guide To Understanding Assembly Short-Circuit Current Rating WITH ENGINEERING SOLUTIONS AND OVERCURRENT PROTECTION DEVICES TO ENHANCE SCCR

Safety Training Topic ELECTRICAL SAFETY

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

ElectricCourseCatalog.

Microinverters and AC PV modules are becoming. Microinverters and AC PV Modules. Different Beasts. Perspectives on PV.

Guideline for Using IEEE 1547 for Solar PV Interconnection Page 1

Umatilla Electric Cooperative Net Metering Rules

Future Proof Your Arc Flash Assessment

Guidelines for Inverter-Based Micro-Generating Facility (10 kw and Smaller)

Mike Holt s Illustrated Guide to SOLAR PV SYSTEMS

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

TABLE OF CONTENTS CHAPTER 1 ELECTRICAL THEORY About This Textbook...xi. Passing Your Exam...xiv. How to Use the National Electrical Code...

NEC REQUIREMENTS FOR GENERATORS

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

Design Standards NEMA

Zero Energy Verification An Alternative Approach. Timothy Snow CESCP Electrical Safety Officer

High Voltage Electrical Maintenance Training

Bulletin Wiring methods for solar photovoltaic systems Rules 2-034, , , , , Tables 11 and 19

UNIT 1 ELECTRICIAN S MATH AND BASIC ELECTRICAL FORMULAS...1 Introduction...1. UNIT 2 ELECTRICAL CIRCUITS...49 Introduction...49

Southern Company Interconnection Process. Dexter Lewis Research Engineer Research and Technology Management

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

ECET 211 Electric Machines & Controls Lecture 8 Motor Control Circuits (1 of 2) Lecture 8 Motor Control Circuits

Integrating Roles Within Electric Utilities to Achieve Arc Flash Safety. MIPSYCON Presenters Neil Stiller & Bob Cooke

Busway. Siemens STEP 2000 Course. STEP 2000 Courses distributed by

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

Grounding Of Standby & Emergency Power Systems

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Please reference the attached file for my comments regarding Case U

GUIDELINES FOR OPERATING, METERING AND PROTECTIVE RELAYING FOR. NET METERED SYSTEMS UP TO 50 kw AND BELOW 750 VOLTS

BP OIL -- TOLEDO REFINERY

Puget Sound Energy Overview

Maryland Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 10 kw to 10 MW or less)

White River Electric Association, Inc. Net Metering Information & Service Requirements

PREVIEW ONLY - FULL COPY AVAILABLE TO CONSORTIUM MEMBERS. Escalator Specific Electrical Systems. Course 209 PARTICIPANT GUIDE

DISTRIBUTED RESOURCE GENERATION Feed-In-Tariff Single Phase

TRANSMISSION SYSTEMS

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

Ignition Coil Current Waveforms 2007 Honda Accord SE 4CYL

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS

Arc-Flash Mitigation Technologies. Dennis Balickie

SERVICE SHOP NOTES. Use ohmmeter to check the resistance between the leads.

Customer Name : Account Number: Customer Service Address (Street, City, State, ZIP Code): Customer Mailing Address: Customer Telephone Number:

Transcription:

Backfeed, Safety, and Work Practices Michael T. Sheehan, P.E. March, 2015 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, operated by the Alliance for Sustainable Energy, LLC.

NEC NESC Boundary Confusion

Boundary between NESC and NEC Electricians tend to work on equipment that is dead (unpowered), to enhance safety. Electricians also tend to work with the lower voltages found in homes and businesses Utilities workers commonly work with live current to maintain power distribution. Utilities workers commonly work with the high voltages found in power lines Boundary Issues Street Lights; PUC Jurisdiction; Arc Fault Values Both the NESC and NFPA 70E include tables that provide the required rating of flame-resistant (FR) clothing for working with power up to 1,000 Vac. But the tables are not the same. The primary difference is that the NFPA 70E table values are based on calculations, while the NESC table values are a combination of arc energy levels from calculations and results from actual test results performed in a utility test lab Clarification of Scope 2012 Edition of the NESC standard now includes detailed language that specifies what the code covers for areas such as generation, transmission, and distribution of electricity

Safety Safety in electric operations, for all employees and the public at large, trumps other considerations. Electric utility personnel perform both live-line work and work on dead facilities. Live-line work requires principles of insulate and isolate to keep workers from dangers; assuring facilities are dead requires the workers to work between grounds applied to the electric facilities being handled.

NESC Requirements NESC Code NESC Requirements for De-energized Work Section 444 of the NESC details requirements Isolate - operate switches, disconnects and lockout /tag Test for voltage Install protective grounds on each side of the work location

Live-Line Work vs. Dead Facilities Electric utility personnel perform both live-line work and work on dead facilities. Live-line work requires principles of insulate and isolate to keep workers from dangers; Declaring facilities are dead requires the workers to work between grounds applied to the electric facilities being handled.

Backfeed Tom Short book 4.10.4 4.10.4 Backfeeds During a line-to-ground fault where a single-phase device opens, current may backfeed through a three-phase load. It is a common misconception that this type of backfeed can only happen with an ungrounded transformer connection. Backfeed can also occur with a grounded three-phase connection. This creates hazards to the public in downed wire situations. Even though it is a weak source, the backfed voltage is just as dangerous. Lineworkers also have to be careful. A few have been killed after touching wires downstream of open cutouts that they thought were deenergized.

Canadian Backfeed Study Conclusions We could find no statistical evidence to suggest that Distributed Generation Facilities less then 500kW in size, create or experience a greater degree of back feed than other forms of customer load where back feed can potentially occur on a distribution system; There was unanimous agreement among utility respondents, that adherence to safe work practice methods is the best means of ensuring worker safety involving back feed in the three common customer load scenario s outlined in our survey. Further work needs to be done to ensure that many current interconnection standards and their associated costs to DG owners reflect the true risks if any to the safety of utility assets, workers and\or the public.

Canadian Utility Survey Results There was unanimous agreement by all survey respondents, that the best means of ensuring worker safety in the three potential backfeed scenario s involves following established safe work practice methods rather then installing redundancy switches, transfer trip or other costly hardware solutions.

Participant Testimonials: Mr. Georges Simarding, M.ing Hydro Quebec Protection equipment is mainly to protect equipment and safe work practice is to protect people

Failures Conditions Needed for Inverter to Back feed on a Deenergized System 1. Inverter fails to disconnect automatically and continues exporting power without the necessary external voltage source present 2. Anti-islanding, voltage and frequency protection fail 3. Output of the inverter ~ matches the connected load such that over current protection (fuse) does not operate Even if the above were to occur, the requirement to test and ground the line before working on it should protect the line worker

Canadian Study Findings Given the growing interest in Distributed Generation across Canada, the utility industry should introduce more worker education to reinforce safe work practice methods and to expose the engineering community to emerging technologies within the renewable resource generation sector DG owners are faced with a site approval process that is extremely complex, slow moving, inconsistent nationally and biased toward over-redundant safety system design It may be argued that introducing over-redundant hardware requirements may in fact introduce a higher degree of risk for workers who become reliant on technology rather then safe work practice methods as a primary means of ensuring safety

Padmount Transformer Design Utility typically purchase three-phase padmount transformer and specify the requirement of 4 or 5 legged core design in order to reduce the probability of tank heating when zero-sequence voltage is applied. The result of a phase loss is not intuitive. The results of a phase loss depend on which phase is lost. This transformer design will allow voltage to backfeed from the energized phase to the open phases.

Existing Distribution Backfeeds 1) Backfeed involving delta primary connections on feeders: One of the more common sources of back feed results from a delta connection on a grounded-wye circuit. This back feed has appreciable power and will readily feed customer loads (though with improper voltage). 2) Backfeed when 3-phase transformers, all with Y-grounded 5-legged-core primary coils, exist and a phase becomes de-energized but not solidly grounded (a high resistance fault). This back feed voltage is induced by the magnetic flux currents in the transformer ferrous core (which is common to all 3 the phases). The capacitance of underground cable usually plays a key role in the LC circuit resulting in the back feed. This back feed voltage can be quite high, higher than the normal phase-to-ground voltage, but has little power behind it: The voltage will collapse when grounded, with a bolted fault current of under 10 amperes. 3) Backfeed involving network transformers: If a network protector on a transformer remains closed when a primary feeder is de-energized, the energized network secondary will back feed the de-energized circuit.

Transformer Backfeeds with Downed Conductor

BC Hydro Observations on Backfeed BC Hydro s experience with the net metering program to date has been positive BC Hydro is not aware of any system or customer-related problems caused by the net metering program. In fact, in the years since program inception in 2004, BC Hydro has observed that some of the potential safety risks that were considered when the net metering program was developed have not materialized, especially with respect to the potential for backfeed of electricity onto the distribution grid.- BC Hydo Report to BC Utility Commission Sept 2011

Equipment Ground & System Ground

Dangerous Levels of Current UL Level

Questions? Michael Sheehan, P.E. IREC 206.232.2493 mikes@irecusa.org