EU MEPS for low voltage electric motors

Similar documents
Brochure EU MEPS Efficiency requirements for low voltage motors Updated for stage 3 requirements from January 1, 2017

Efficiency classes of single-speed three-phase, cage-induction motors

Low voltage motors for hazardous areas Safe, reliable and highly efficient

New efficiency standards and directives applicable to motors in Europe

EU Regulation for Premium Efficiency IE3 motors 2, 4, 6 poles efficienza

How do you take the first step towards an energy efficient future?

EFFICIENCY REGULATIONS FOR MOTORS AND MOTOR SYSTEMS

COMMISSION REGULATION (EC)

EFFICIENCY REGULATIONS FOR MOTORS AND MOTOR SYSTEMS

Energy Efficiency with Low Voltage Motors

Catalog January 2017 Standard low voltage motors Regional catalog for Middle-East and Africa

Contact us. Catalog Low voltage generators for diesel and gas engines Industrial Marine applications - series Standard series

Press information. Using energy-efficient electric Motors. Meeting the International Energy Directives. October 2013

BROCHURE. IE4 SynRM motor-drive packages Super premium efficiency for industry

Including list of all affected Side Channel Blowers. Information about IE2, IE3 and NEMA motor changeover for blowers and side channel blowers

Modular DR motor concept: Standard AC motors and energy-efficient motors of efficiency class IE

الهيئة السعىدية للمىاصفبت والمقبييس والجىدة Saudi Standards, Metrology and Quality Org (SASO)

Brochure. Synchronous generators for steam and gas turbines Proven generators reliable power

How to implement higher efficiency motors

Mini contactors B6, BC6 with 3 pole

Brochure. Synchronous generators for diesel and gas engines Proven generators reliable power

Catalog June 2016 Low voltage General performance motors

HIGH EFFICIENCY INDUCTION MOTORS COMBROHEF001_=

EC Gold Series Synchronous permanent magnet motor

Optimized cost of ownership See all the hidden costs without paying any. ABB Title Lorem Ipsum dolor sit Possible Subtitle

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW

Sarah Hatch, Senior Project Officer - Lighting and Equipment Energy Efficiency Team DEWHA October 2008

WORLD Energy regulation guideline

Ecodesign We meet the strictest requirements yours

EuP & Electric Motor legislation. Chris Lawton CSO

High efficiency induction motors

ABB motors Low voltage general performance motors M2000 Cast lron Frames

Efficiency Standards for External Power Supplies

COMBROIND001_= THREE PHASE SQUIRREL CAGE INDUCTION MOTORS. IE1 motors MAA - BAA Series IE2 motors MAQ - BAQ Series

Efficient Electric Motor Systems

ABB DRIVES SERVICE. Optimize your wind economy. Wind Converter Services

PQstorI One stop solution for energy storage and power quality

IECEE. Taking Conformity Assessment Further

Catalog March 2016 Low voltage Process performance motors

ZX2 Gas-insulated medium voltage switchgear

FAQ. Frequently Asked Questions on exhaust emission requirements for tractors. European Agricultural Machinery Association.

Recent Development in Energy Efficiency Policy in the EU

EMPAC Metal enclosed capacitor bank for wind applications

From 16 June 2011, motors placed for the first-time on the market shall have a minimum efficiency class of IE2.

NEMA MOTORS. Aggregate motors

English version. This Technical Specification was approved by CENELEC on

Catalog October 2014 Low voltage General performance motors according to EU MEPS

ABB Motors and Generators Training. Sharing knowledge and creating value

PQC - STATCON The ultra fast Power Quality Compensator

The Energy Policy Act. The law s requirements for 1 to 200 horsepower AC motors effective October 24, 1997

Motor Systems Technology Developments

Marine generators Proven generators for reliable power on board

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

IE3 RANGE PREMIUM EFFICIENCY THREE-PHASE MOTORS

Rotating Power AC Motors and Generators

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

Energy savings in drive applications

Baldor-Reliance Food Safe Stainless steel NEMA motors

Product Brochure. Torque-Arm II

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Transformers. Reduced emission painting for transformers Lower volatile organic compound painting systems

Catalog. Low voltage Industrial performance motors

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

EU TOY DIRECTIVE 2009/48/EC: OVERVIEW - REGULATORY CONTEXT AND MAJOR CHANGES

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

WEG Control and Protection Components

Lot 30 ELECTRIC MOTORS & Drives

Product Brochure. Quantis gearmotors & reducers

ECO-DESIGN OF ELECTRIC MOTORS

IEC : CONTENTS

ABB central inverters PVS to 2091 kva

Manual motor starters Overview and benefits

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

LV Capacitors QCap-L series Capacitors for power factor correction

DODGE MECHANICAL. Grain industry Delivering solutions that solve industry challenges

Surge arrester POLIM-H.. ND

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Electronic overload relays EF205 and EF370

Motor Efficiency Improvements for Pumping Applications. Brent McManis, P.E. Industry Engineering Manager Baldor Electric: A Member of the ABB Group

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Surge arrester POLIM-C.. HD

Best Practice High Eff iciency Motors

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

Product brochure. MagnaGear XTR gear reducers

High voltage flameproof induction motors The simplest solution for hazardous environments

ASYNCHRONOUS MOTORS THREE-PHASE MOTORS SINGLE-PHASE MOTORS BRAKE MOTORS IE3 IE2

Legal Statement. M E T A L S Research and Consulting

Surge arrester POLIM-H..SD

Directive ErP 125 and Fans by Systemair

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

COMMISSION REGULATION (EU) / of XXX

In harmony. Defining global energy-efficiency standards Janusz Maruszczyk, Michel Lhenry, Mikko Helinko, Zbigniew Korendo. Efficiency and standards

Slide 1. ABB September 9, 2015

ErP Directive ErP Implementing Regulation 327/2011. The new minimum efficiencies for electrically powered blowers and the impact on Elektror devices

Exceeding the standards with MNS

Thermal overload relay TF140DU and TF140DU-V1000

Transcription:

EU MEPS for low voltage electric motors

EU MEPS in brief EU MEPS (European Minimum Energy Performance Standard) sets mandatory minimum efficiency levels for electric motors introduced into the European market. It is part of the EU s ecodesign project, which aims to reduce the energy consumption and other negative environmental impacts of energy-related products. The EU MEPS scheme covers most single speed, three-phase induction motors up to 375 kw (see Scope). It will come into effect in three stages from mid 2011 onwards. Under the scheme manufacturers are required to show the IE (International Efficiency) class and efficiency values on motor rating plates and in product documentation. EU MEPS is based on two IEC (International Electrotechnical Commission) standards. It requires efficiency to be measured using methods specified in IEC/EN 60034-2-1: 2007, and uses efficiency classes defined in IEC/EN 60034-30. As EU MEPS is based on international standards, it represents an important step towards harmonization of efficiency regulations on a global scale. Scope EU MEPS covers 2-, 4- and 6-pole single speed, threephase induction motors in the power range 0.75 to 375 kw, rated up to 1000 V. It covers all duty types, as long as the motors are capable of continuous duty operation. The following types of motors are excluded: motors designed to operate wholly immersed in a liquid; motors completely integrated into a product where the motor s energy performance cannot be tested independently from the product; motors specifically designed to operate continuously: - at altitudes exceeding 1000 meters ASL; - outside the ambient air temperature range of -15 C +40 C - in maximum operating temperatures above 400 C; - where the water coolant temperature at the inlet to a product is less than 5 C or exceeds 25 C; - in potentially explosive atmospheres as defined in Directive 94/9/EC; brake motors. Specifically designed means that the motor has a special winding, fan, grease, etc. different from a standard motor. Please note that the information in this brochure reflects ABB s present understanding of the situation. Certain aspects of the regulations are currently open to interpretation, and accordingly the EU Commission is planning to issue further clarification. It is therefore likely that some of the details shown here will change. ABB intends to provide updated information when this becomes available. 2 EU MEPS for low voltage electric motors ABB LV Motors

Timeline October 2009 Forthcoming clarification 2011 16 June 2011 1 January 2015 1 January 2017 EU adopted Directive 2009/125/EC establishing a framework for the setting of ecodesign requirements for energy-related products (ErP). The requirements apply to electric motors with effect from mid 2011 onwards, giving manufacturers around 2 years to ensure that their products comply. Clarification of the wording of Commission Regulation EC 640/2009, which implements Directive 2009/125/EC with regard to ecodesign requirements for electric motors. Stage 1: Motors must meet the IE2 efficiency level Stage 2: Motors with a rated output of 7.5 375 kw must meet EITHER the IE3 efficiency level OR the IE2 level if fitted with a variable speed drive Stage 3: Motors with a rated output of 0.75 375 kw must meet EITHER the IE3 efficiency level OR the IE2 level if fitted with a variable speed drive ABB and EU MEPS ABB complies with all aspects of Commission Regulation EC 640/2009. Therefore, from June 16, 2011 onwards ABB will not offer / sell / deliver in any markets globally IE1 CE marked products that fall into the scope of EC 640/2009. ABB has a full range of IE2 motors available from stock, and a broad range of IE3 and IE4 motors. As the world market leader, ABB offers the largest range of LV motors available. It has long advocated the need for efficiency in motors, and high efficiency products have formed the core of its portfolio for many years. ABB LV Motors EU MEPS for low voltage electric motors 3

Frequently Asked Questions Are manufacturers allowed to produce IE1 motors after 16 June 2011? Standard efficiency (IE1) motors may no longer be placed on the European market as of 16 June 2011. As of that date all new motors will have to meet the IE2 (high efficiency) rating in Europe. EU MEPS does not apply outside Europe. Manufacturers can continue to supply IE1 non-ce marked motors to customers located in Europe for further shipment to non-european markets. In this case a statement is required from the customer confirming that the motors final destination is outside Europe. Does EU MEPS cover brake motors? No. Brake motors are excluded from the Comission Regulation EC 640/2009. If a motor is rated for altitudes in excess of 1000 m does it fall within the scope of EU MEPS? Yes, if the motor is of a standard type but de-rated for operation at altitudes in excess of 1000 m. No, if the motor has a special design (winding, fan, grease, etc.) for operation in excess of 1000 m. When I purchase a motor, how can I be sure that it meets the requirements of EU MEPS? Check the motor rating plate and ask for the test report. The rating plate should be stamped with the efficiency class IE2 as a minimum and efficiency values (see Markings and documentation). The IE class stamped on the plate must be based on the lowest efficiency value at the rated voltage/ frequency/output combination shown on the rating plate. In the case of ABB motors, the IE class and efficiency values are stamped on the rating plate and test reports are available on ABB s website. The efficiency class stamped on the rating plate is verified using the testing methods specified in IEC 60034-2-1: 2007. ABB utilizes low uncertainty testing methods. Does EU MEPS cover motors for explosive atmospheres? No, EU MEPS does not cover all the types of motor covered by IEC 60034-30. Some motors (such as motors for explosive atmospheres) are included in IEC 60034-30 but excluded from EU MEPS. As a global player, ABB will follow the requirements of IEC/ EN 60034-30. Even though it is not required under EU MEPS, ABB will also provide IE markings for standard motors for explosive atmospheres. Does EU MEPS cover marine motors? No. Marine motors are designed for ambient temperatures outside the range -15 C +40 C, specified in the Comission Regulation EC 640/2009. Can a motor without IE marking be placed on the European market after 16 June 2011? No. Motors placed on the market on 16 June 2011 or after must have the IE marking. Even if the motor was ordered before 16 June 2011 it cannot be delivered without the IE marking after 16 June 2011. ABB will roll out the new IE rated motors into all central stocks in time for the introduction of EU MEPS. Can a motor be rewound and still be used after 16 June 2011? EU MEPS does not regulate rewinding. As long as the motor has been placed on the market or put into service prior to 16 June 2011 it does not have to meet the minimum efficiency requirements. This means that when a motor fails the user has the normal choice between rewinding and replacement. Even though rewinding is still permitted, however, the user should carefully consider the advantages of replacing the motor rather than having it rewound. Each rewind normally reduces a motor s efficiency by 1 3 %. In many cases the payback period for a new motor is less than three years. A new high efficiency motor costs less over the long term, because the initial purchase cost is much lower than the lifetime operating expenses. What does EU MEPS mean by placed on the market or put into service? The way these concepts should be understood is that placing on the market (making a product available for the first time on the EU market) and putting into service (first 4 EU MEPS for low voltage electric motors ABB LV Motors

use of a product for its intended purpose by an end-user in the EU) refer to two different moments in the process of bringing a product to the market. Compliance for entry into the market is required only once, based on the moment when the product is placed on the market or when it is put into service. Accordingly, Article 3 of the Ecodesign Directive (2009/125/EC) should be taken to mean that products covered by implementing measures may be placed on the market or put into service, or both, only if they comply with those implementing measures and bear CE marking in accordance with Article 5. A product has to comply with the requirements for CE marking from the moment that it is placed on the market. Only in cases where a product is not placed on the market in the literal sense shall the moment of compliance be the time when the product is put into service. As of 16 June 2011 motor manufacturers cannot place on the market (sell) motors in Europe that are destined for final use in the EU market and do not meet IE2 efficiency levels. Motor users cannot put into service (install) new motors that do not have the correct IE2/CE marking. However, users can install motors from their stock that were purchased before 16 June 2011. As of 16 June 2011, are distributors or OEMs allowed to sell IE1 motors put into their stock previous to that date? Yes, the EU legislation is not retroactive. These motors can be sold provided that they were put into stock or into the distribution chain before 16 June 2011. Products legally placed on the market can stay on the market and still be sold to the end-user and put into service. Does EU MEPS apply to dual purpose smoke extraction motors? The answer depends on the type of motor: Yes, if the motor can be tested by the motor manufacturer at rated power and normal ambient with its own fan. This type of motor is covered by EU MEPS and must have the correct IE markings as of 16 June 2011. No, if the motor cannot be tested independently at rated power (ie, it requires a fan supplied by an outside manufacturer). These products known as TEAO or Totally Enclosed, Air Over motors are not covered by EU MEPS. Does EU MEPS cover motors intended for VSD use? Motors that can be used with a VSD and run direct on line (DOL) are covered by EU MEPS and must have the correct IE marking. Motors produced for VSD duty only (motors that cannot be run DOL), such as permanent magnet motors, are not covered and do not need an IE marking. ABB LV Motors EU MEPS for low voltage electric motors 5

Efficiency classes IEC/EN 60034-30 EU MEPS EISA 2007 Local regulations IE3 Premium efficiency IE3 Premium efficiency IE3 values at 60 Hz are identical to NEMA Premium efficiency IE2 High efficiency IE2 High efficiency IE2 values at 60 Hz are identical to NEMA Energy efficiency/epact Canada Mexico Australia New Zealand Brazil China 2011 Switzerland 2012 IE1 Standard efficiency Below standard efficiency after 16.6.2011 Below standard efficiency China Brazil Costa Rica Israel Taiwan Switzerland In addition, IEC/TS 60034-31 introduced IE4 / Super Premium Efficiency, an efficiency level above IE3. EU MEPS efficiency classes are based on IEC/EN 60034-30: 2008. The table above shows the EU MEPS and IEC efficiency classes, with the EISA 2007 classes for comparison. Note that the scope of IEC/EN 60034-30: 2008 is wider than that of EU MEPS. The IEC standard covers motors for explosive atmospheres and brake motors, for example, which are excluded from EU MEPS. As a global player, ABB will follow the IEC standard, and will provide efficiency class information (on the rating plate and in documentation) for motors for explosive atmospheres and brake motors even though this is not required under the EU MEPS scheme. More detailed information on IEC 60034-30: 2008 is available from ABB Technical note TM025 RevB 2009. 6 EU MEPS for low voltage electric motors ABB LV Motors

Markings and documentation From 16 June 2011, the following information must be shown on the motor rating plate: Lowest nominal efficiency at 100 % rated load Efficiency level (IE2 or IE3) Year of manufacture In addition EU MEPS lists information that has to be shown in motor technical documentation and on manufacturers free-access websites. ABB determines efficiency values according to IEC/EN 60034-2-1 using the low uncertainty method (ie, indirect method with additional load losses determined by measurement). More detailed information on IEC 60034-2-1: 2007 is available from ABB Technical note TM018 RevC 2009. The rating plates of all ABB motors covered by IEC/EN 60034-30 including motors for explosive atmospheres will carry the lowest efficiency values and associated IE code with efficiency at 100 %, 75 % and 50 % load. As standard ABB will stamp the safe area motors: Frame sizes up to 132: 230 V, 400 V 50 Hz and 460 V, 60 Hz with 50 Hz output Partial load efficiency only at 50 Hz Frame sizes up to 250: 400 V, 415 V, 690 V 50 Hz and 460 V, 60 Hz with 50 Hz output Frame sizes up to 450 and all Ex-motors: 400V, 415V, 690V 50Hz ABB LV Motors EU MEPS for low voltage electric motors 7

Contact us www.abb.com/motors&generators We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained herein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in part is forbidden without prior written consent of ABB AG. Copyright 2011 ABB All rights reserved 9AKK105072 EN 05-2011 Printed in Finland, 05-2011/5000, Waasa Graphics.