E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Similar documents
Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plug and Socket Devices SolConeX 16 A Series 8570

Terminal Boxes Series 8125

Load disconnect switch Series 8146/5-V11

Terminal Boxes Series 8125

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Safety Switches Series 8537

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Control Buttons / Switches for Panel Mounting Series 8003

Control Buttons Series 8082

Load and Motor Switches, Load-Break Switches Series 8549

Load and Motor Switches, Load-Break Switches Series 8544

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Compact Sheet-Steel Light Fittings Series 6114/1

Position Switches Series 8060/2

Control switch/load disconnect switch Series 8008

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Load and Motor Switches, Load-Break Switches Series 8544

Position Switches Series 8070/2

Ex UPS standard Series 8265

Operating Instructions

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Operating Instructions

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Position Switches Series 8074/2

Emergency Light Fitting for Fluorescent Lamps Series 6009

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

7 Lighting Technology

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Floodlight LED Series 6125

LED Linear Luminaire Series EXLUX 6402

7 Lighting Technology

Linear Luminaire with LED Series EXLUX 6402/2

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Sensor boxes SRBE Key features and product range overview

Floodlight LED Series 6525

Floodlight LED Series 6525

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Emergency Luminaire with LED Series EXLUX 6409/1

11 Control Panels, Distribution Panels and Components

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

10 Load and Motor Switchgear

Pendant Light Fitting IEC

PHOENIX CONTACT - 01/2008

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Solenoid Valve Island Type 3965

Linear Luminaire for Fluorescent Lamps

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Linear luminaire with LED Series EXLUX 6002

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Pneumatic control unit for decentralized automation of ELEMENT process valves

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Operating Instructions

Solenoid Valves Type 3963

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

HERION SERIES Indirect solenoid actuated soft seal

Floodlight Series 6121

IS1 I/O-Modules. BusRail Series General Information. Symbols. Conformity to Standards. Safety instructions. Function/Characteristics

Assembly. Trunk IN + - S U, I U, I. Spur 1

97100 NAMUR. Technical data

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Floodlight Series 6521/4

Main current switches >180 A are realized in metal enclosures. Internationally approved.

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features. Display

Tubular Light Fitting with LED Series 6036

Compact Sheet-Steel Light Fittings Series 6114

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function)

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

I Ex-safety switches I

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

New products Ex Equipment 2015

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

Load cells. Data sheet. Special features. Cable assignment (six wire configuration)

JUMO dtrans p20 DELTA

Control Device System NEC Series ConSig 8040

Sheet-Steel Light Fittings Series 6014 / 6414

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

Magnetic-inductive flow meter for hazardous areas

Level Measurement Continuous level measurement Ultrasonic transmitters

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Compact temperature switch Model TCS

SCHISCHEK REDBIN-D TRANSMITTER

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Transcription:

900/77-80-094-001 158877 For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more compact, space-saving devices that are easy to install on a DIN rail quick to install as barriers can be simultaneously snapped onto rail and connected to PE WebCode 900A The 900 series INTRINSPAK two-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require very little space. The back-up fuse is a convenient feature as it is standardised for all variants. Technical Data Explosion Protection Application range (Zone) Ex-interface zone 0 1 0 1 Certificate IECEX Gas IECEx PTB 08.0057X Certificate ATEX Gas PTB 01 ATEX 053 X Certificate IECEX Dust IECEx PTB 08.0057X Certificate ATEX Dust PTB 01 ATEX 053 X Gas explosion protection IECEx Ex na [ia Ga] IIC/IIB T4 Gc Gas explosion protection ATEX E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc Dust explosion protection IECEx [Ex ia Da] IIIC Dust explosion protection ATEX E II (1) D [Ex ia Da] IIIC Certificates ATEX, Brasil (INMETRO), Canada (CSA / c FM), China (China-Ex), Corea (KCs), EAC (TR), IECEx, USA (FM / UL) Installation in Zone, Division and in safe area Safety Data Max. Voltage U o Max. Current I o Max. Power P o max. perm. ext. inductance IIB 30 mh max. perm. ext. inductance IIC 10.1 mh max. perm. ext.capacitance IIB 0.65 μf max. perm. ext.capacitance IIC 0.083 μf Further information see respective certificate and operating instructions 017-08- R. STAHL Schaltgeräte GmbH Am Bahnhof 30 D 74638 Waldenburg www.r-stahl.com 1/5

900/77-80-094-001 158877 Electrical Data Number of channels Channel 1 1 + Nominal voltage U N 4 V Min. resistance R min Max. resistance R max Max. voltage U o Max. current I o 94 ma Max. power P o 660 mw Max. resistance R max Min. resistance R min Potential Potential Ch 1 potential CH Transmission frequency in case of resistive 100 khz current limiting >= 50mA Transmission frequency in case of resistive 50 khz current limiting <= 50mA Leakage current at Un µa Leakage current at Un (if not stated otherwise) Channel Nominal voltage U N Min. resistance R min Max. resistance R max 1 1 + 4.00 V Ambient Conditions 657.00 Ω 657.00 Ω 730.00 Ω 730.00 Ω Min. ambient temperature -0 C Max. ambient temperature +60 C Min. storage temperature -0 C Max. storage temperature +75 C Max. relative humidity 95 % mean, no dewing Temperature influence 0,5 %/10K Mechanical Data Type of protection (IP) IP40 Type of protect.(ip) Terminals IP0 Enclosure material Polyamide 6 GF Gross weight 0.11 kg Number of connection terminals 4 Max. voltage Max. current I o Max. power P o U o 8.00 V 8.00 V 8.00 V 47.0 ma 47.0 ma 94.0 ma 330.000 mw 330.000 mw 660.000 mw 017-08- R. STAHL Schaltgeräte GmbH Am Bahnhof 30 D 74638 Waldenburg www.r-stahl.com /5

900/77-80-094-001 158877 Mechanical Data Max. Terminal support Terminal cross-section Type of connection line Width Length Mounting depth Mounting / Installation Connection type 1.5 mm² 4 mm² finely-stranded solid 103 mm 1 mm 7 mm PA Technical Drawings Hazardous area Safe area Intrinsically safe eld device(s) U N Control room equipment 0V / PA Two-channel safety barriers, / Dimensional Drawings (All Dimensions in mm [inches]) Subject to Alterations 95 [3,74] 76 [3,00] 103 [4,06] 80 [3,15] mounting on DIN rail NS 35/15 1 [0,47] 7 [,83] 66 [,60] 38 [1,50] 66 [,60] 38 [1,50] mounting on mounting plate by means of adaptor mounting on DIN rail NS 3 by means of adaptor and mounting attachment, moulded plastic 017-08- R. STAHL Schaltgeräte GmbH Am Bahnhof 30 D 74638 Waldenburg www.r-stahl.com 3/5

900/77-80-094-001 158877 Accessories and Spare Parts Back-up fuse for all safety barriers Series 9001, 900 and 9004 unit: 5 pcs. 158964 Holder for label Transparent cover for labelling 158977 Labelling paper perforated, for typing Format: DIN A4 158973 Adaptor Adaptor allows installation of a safety barrier Series 900x on a mounting plate of a previous series. 15886 Mounting attachment moulded plastic Enables mounting of safety barrier on a G-rail. 16583 DIN rail NS 35 / 15 (meter length) 103714 Earth terminal Fuse holder USLKG 5 (wire range( 4 mm ) Terminal enables connection of protective conductors to DIN rail. Colour green-yellow. USLKG 6 N (wire range( 6 mm ) Terminal enables connection of protective / earthing conductors to DIN rail. Colour green-yellow. Fuse holder is snapped onto the side of the safety barrier and can be equipped with up to 5 back-up fuses (replacement). 11760 11599 158834 Insulating stand off Suitable for DIN rail NS 35/15, allows electrically insulated mounting of DIN rail from mounting plate. 15888 017-08- R. STAHL Schaltgeräte GmbH Am Bahnhof 30 D 74638 Waldenburg www.r-stahl.com 4/5

900/77-80-094-001 158877 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. 017-08- R. STAHL Schaltgeräte GmbH Am Bahnhof 30 D 74638 Waldenburg www.r-stahl.com 5/5