Similar documents
CT - CTS inserts with incorporated terminal block for multipole connectors (10A max versions)

HEAVY DUTY MULTIPOLE CONNECTORS

HEAVY DUTY MULTIPOLE CONNECTORS

T-TYPE / W T-TYPE/W. Aggressive environments. IP66 for aggressive environments. MULTIPOLE CONNECTORS T-TYPE/W Technical data CN

HEAVY DUTY CONNECTORS FOR INDUSTRIAL APPLICATIONS FAST CHECK

Heavy Duty ConnectorS. Fast Check

General characteristics

BIG THE SPACE YOU HAVE ALWAYS WANTED... LARGE MODULAR ENCLOSURE MORE ENTRIES AND SPACE FOR CABLES EASY WIRING AND INSPECTION ELECTRONIC BOARD SLOTS

reliable economical general characteristics

HYGIENIC HYGIENIC. application fields. For food and beverage. food & beverage applications. MULTIPOLE CONNECTORS HYGIENIC Application fields CN

general characteristics

EL5600 Series Electric Actuators for DN15 to DN100 Valves

JUMO MIDAS Pressure transmitter

D-Sub adapter Cable entry protection with metric cable entries Cable entry protection with Pg cable entries

Insulator Connector inserts: Polyamide (PA66) UL 94 V0 All connectors with different shielding material for different jacket and shield diameters.

Han K 3/0, K 3/2 / Han HC Modular. Contents Technical characteristics Han K 3/0, Han K 3/ Inserts Han K 3/0, Han K 3/

Number of PG holes. 1 x PG 9 (Ø 15.5) 12 x PG 13.5 (Ø 21) 1 x PG 9 (Ø 15.5) /300/400/ Rittal Catalogue 32/Industrial Enclosures

HBE 24 SCREW & CRIMP TERMINATED INSERTS

Multipole Industrial Connectors Aluminium enclosures - Cable glands and fittings

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Motor cable length 0.3 m. T [mm]

Support arm system CP, with new height-adjustable support section

Position switches FD series

HB IP65 Hood and Housing Series

A44 W0...W2: Motorised actuator

ACME SCREW LINEAR ACTUATOR. OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor

enclosures with IP67 V-Type closure

Position switches FR series

PRECISION MOTION CONTROL

Controls F792 Switchbox LP Series

LS Series Limit Switches. Short Form Catalogue AC1300 ABB

EExe and EExi terminal boxes in polyester and aluminium for Ex areas

ATL 12 ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. La =Lc + Stroke Lc T. Rear bracket SP. Stroke. Capacitor

SRP981 Pneumatic Positioner

AEL5 Series Electric Linear Actuators for DN15 to DN100 Control Valves

LK Position Switches TECHNICAL DATASHEET.

GIB TECHNICAL DATA MECHANICAL DIMENSIONS SINGLE/DUAL AXIS ENTRY LEVEL TILT SENSOR (XY/Z) ENTRY LEVEL tilt sensor with MEMS technology.

SITRANS P measuring instruments for pressure

Sealed Enclosures. Contact Blocks. Multiple Actuators

Limit switches Osiswitch Classic For hoisting and materials handling applications, type XCR Complete switches with 1 cable entry

Actuators for air dampers and control valves of oil burners

[ T] THREE-PHASE MOTORS «[32] [33] Three-Phase Motors - Technical Catalogue 1018/10

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

Gross Automation (877)

Shell material Insulator Contacts Sealing Temperature Mating Protection

Actuators for air dampers and control valves of oil burners

SPECIFICATION SHEET ORION ROAD LANTERN. IP66 RATED CRI. 230v /50hz

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Single foot switches PX and PA series

Position switches FR series

(%$5$ PUMPS EUROPE S.p.A. &(175,)8*$/38036':2. &217(176 50Hz

systems Features Technical Data Spindle Motor Frequency Converter FC 1500-CT Dimensions CNC Base Machines E23 CNC Base Machines SYSTEMS Accessory

Solenoid coil Types BB, BE, BF, BG, and BN

STRAW MULCHERS WITH BLOWER MOD: GA-110 SLS / GA-130 SLS

ED SERIES SAFETY LIMIT SWITCH

86740/ /2-way piston valves

Polyester enclosures CP series

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Pressure switch and Thermostat Type CAS

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Actuator with. Attachment A1. Lc [mm] Stroke Stroke T [mm] Stroke Stroke

Technical Data, High Power 2-way* Cannon APD / ISO Connectors. Electrical Data. Mechanical Data. Environmental Data (acc.

The new BERNSTEIN Aluminium Suspension System

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE DWC PERFORMANCE CURVE DWC

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

FL series position switches

Rotary Sensor potentiometric Heavy-duty. Series IPX-7900

Differential Pressure Sensors

Type 3660 and 3661 Positioners

REMOTE MOUNT SOLENOID DRIVER (0-5 VDC/0-20 ma/10k Potentiometer Input)

When ordering, please state type and code number. Suitable sensor length. Max. Cap. range. tube adjust- see also Accessories. sensor. temp.

Pressure and temperature controls, Type CAS

Position switches FC series

Plastic enclosures compact Of polycarbonate. Degree of protection: IP 66, 67, 69K UL type1, 3R, 4, 4X, 12, 13

Light Fitting Support

Pressure control for air and water Type CS

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

ARI-PACO 2G 1,6 D/Y. Electric thrust actuator. Electric thrust actuator ARI-PACO 2G 1,6 D/Y. Electric thrust actuator. ARI-PACO 2G 1,6 D 1,6 kn

Easy and safe installation

Standard Hoods/Housings Han B Size 24 B

BC 4.3. Gas Tight Dampers GTD-GB40-B-E LISTED

ACME SCREW LINEAR ACTUATOR. Current [A] PERFORMANCES with AC 3-phase 50 Hz 230/400 V or 1-phase 50 Hz 230 V motor

Selection. Radiator Caps. Recovery Caps (double seal) Non Recovery Caps (single seal) Pressure Rating. Safety Lever Radiator Caps. Pressure Conversion

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS

LED safety Luminaries

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. MASS [Kg] STROKE T STROKE LENGTH STROKE LENGTH. standard brake CODE

Air volume 24 m³/h (14.1 CFM) Rated power 13 W Size (14.1) 55 (32.4) 100 (58.9) Air volume (with exhaust filter installed)

VALVES WITH NA ELECTRIC ACTUATOR

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Pressostats and thermostats CAS

PALADINE ROUND ROUND BULKHEADS For protected area lighting

HANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1

Pressure transmitter for industrial applications Type MBS 4500

The modular structure makes it possible to build at least 5 configurations for each visual lens unit

STRAW MULCHERS WITH BLOWER MOD: GA-110 SLS / GA-130 SLS

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

Limit Switch - Prewired Type Metal Body

S 470. ASSEMBLED STACK LIGHTS Ø 70mm

ar160 Kopa adjustable round diffused

Low-Voltage Motors. Catalog M

INTEGRATED HYDRAULIC BRAKE ACTUATORS

Transcription:

CH enclosures size.27 standard version CTE, CTSE... 6 poles + m 106 bulkhead mounting housings bulkhead mounting housings with 2 pegs description part No. part No. with lever with lever and cover CHI 06 L CHI 06 LS with pegs 1) CHI 06 LC with pegs and aluminium cover 1) CHI 06 LCS with pegs and plastic cover 1) CHI 06 LCP 1) May be combined with hoods: - CHO/CHV 06 LX - MHO/MHV 06 LX N.B.: the enclosures ensure IP66 protection (or IP65 cover versions) rating when mated and locked with the closing levers. The cover (CS, CP) only ensures mechanical protection, but does not ensure IP65 protection rating. panel cut-out for bulkhead mounting housings in mm ø.5 dimensions in mm CHI L.5 76.5 dimensions in mm CHI LC.5 CHI LS CHI LCS/LCP 52 97 65 32 35.5.5 (excluding enclosures with plastic cover) 176

CH - CA and MH - MA enclosures size.27 standard version surface mounting housings description part No. entry part No. entry Pg M with lever CHP 06 L 16 MHP 06 L20 20 with lever CHP 06 L2 16 x 2 MHP 06 L220 20 x 2 with lever, high construction CAP 06 L 21 MAP 06 L32 32 with lever, high construction CAP 06 L2 21 x 2 MAP 06 L232 32 x 2 with lever, high construction CAP 06 L MAP 06 L0 0 with lever, high construction CAP 06 L2 x 2 MAP 06 L20 0 x 2 with lever and cover CHP 06 LS 16 MHP 06 LS20 20 with lever and cover CHP 06 LS2 16 x 2 MHP 06 LS220 20 x 2 with lever and cover, high construction CAP 06 LS 21 MAP 06 LS32 32 with lever and cover, high construction CAP 06 LS2 21 x 2 MAP 06 LS232 32 x 2 with lever and cover, high construction CAP 06 LS MAP 06 LS0 0 with lever and cover, high construction CAP 06 LS2 x 2 MAP 06 LS20 0 x 2 N.B.: the enclosures ensure IP66 protection (or IP65 cover versions) rating when mated and locked with the closing levers. The cover (CS, CP) only ensures mechanical protection, but does not ensure IP65 protection rating. dimensions in mm CHP L - CAP L and MHP L - MAP L D A B C CHP LS - CAP LS and MHP LS - MAP LS D A B C type A B C D CHP L / MHP L 53 0 52 73.5 CAP L / MAP L 7 5 57 CHP LS / MHP LS 53 0 52 97 CAP LS / MAP LS 7 5 57 97 177

CH - CA e MH - MA enclosures size.27 standard version hoods with 2 pegs hoods description part No. entry part No. entry part No. entry part No. entry Pg M Pg M with pegs, side entry CHO 06 L13 13,5 MHO 06 L20 20 with pegs, side entry CHO 06 L16 16 MHO 06 L25 25 with pegs, side entry, high construction CAO 06 L21 21 MAO 06 L25 25 with pegs, side entry, high construction CAO 06 L MAO 06 L32 32 with pegs, side entry, high construction, without adaptor * CFO 06 L21 21 MFO 06 L25 25 with pegs, side entry, high construction, without adaptor * CFO 06 L MFO 06 L32 32 with pegs, top entry CHV 06 L13 13,5 MHV 06 L20 20 with pegs, top entry CHV 06 L16 16 MHV 06 L25 25 with pegs, top entry, high construction CAV 06 L21 21 MAV 06 L25 25 with pegs, top entry, high construction CAV 06 L MAV 06 L32 32 with pegs, top entry, high construction, without adaptor * CFV 06 L21 21 MFV 06 L25 25 with pegs, top entry, high construction, without adaptor * CFV 06 L MFV 06 L32 32 with lever, top entry CHV 06 LG 16 MHV 06 LG25 25 with lever, top entry, high construction CAV 06 LG21 21 MAV 06 LG25 25 with lever, top entry, high construction CAV 06 LG MAV 06 LG32 32 with lever, top entry, high constr., without adaptor * CFV 06 LG21 21 MFV 06 LG25 25 with lever, top entry, high constr., without adaptor * CFV 06 LG MFV 06 LG32 32 * enclosure without adaptor, threaded on the body, to dimensions in mm dimensions in mm be used only with a complete cable clamp. CHO L (CAO L) and (CFO L) CHV LG (CAV LG) and [CFV LG] MHO L (MAO L) and (MFO L) MHV LG (MAV LG) and [MFV LG] 7 (72) [77.5] 58.5 (93 max) CHV L (CAV L) and [CFV L] MHV L (MAV L) and [MFV L] [72] 53 (87.5 max) 178

CH - CA e MH - MA enclosures size.27 standard version CTE, CTSE... 6 poles + m 106 hoods covers description part No. entry part No. entry part No. Pg M with lever, without gasket, side entry 1) CHO 06 LX16 16 MHO 06 LX20 20 with lever, without gasket, side entry 1) MHO 06 LX25 25 with lever, without gasket, top entry 1) CHV 06 LX16 16 MHV 06 LX20 20 with lever, without gasket, top entry 1) MHV 06 LX25 25 with lever (for hoods with pegs) with pegs (for housings with lever) with pegs and gasket (for hoods with lever) 2) CHC 06 LG CHC 06 L CHC 06 LC 1) May be combined with housings: CHI 06 LCS/LCP/LC dimensions in mm dimensions in mm 2) May be combined with housings: - CHO/CHV 06 LX - MHO/MHV 06 LX CHO LX and MHO LX CHC LG 7 CHV LX and MHV LX CHC L 53 12 CHC LC 179

CH - CA and MH - MA enclosures size.27 aggressive environments CTE, CTSE *)... 6 poles + m 106 housings and cover hoods and cover *) only for enclosure CHIW 06 L description part No. entry part No. entry part No. entry part No. entry Pg M Pg M bulkhead housing with lever CHIW 06 L --- surface housing with lever, high construction CAPW 06 L 21 MAPW 06 L32 32 cover with pegs (for enclosures with lever) CHCW 06 L with pegs, side entry, high construction CAOW 06 L21 21 MAOW 06 L32 32 with pegs, top entry, high construction CAVW 06 L21 21 MAVW 06 L32 32 cover with lever (for enclosures with pegs) CHCW 06 LG with lever and gasket, top entry, high construction CAVW 06 LG 21 MAVW 06 LG32 32 panel cut-out for bulkhead mounting housings in mm dimensions in mm dimensions in mm ø.5 CHIW L CAOW L and MAOW L 76.5 52 72.5 32 35 CAPW L and MAPW L CAVW L and MAVW L 7 87.5 max 5 57 CHCW L CHCW LG 12 CAVW LG and MAVW LG 93 max 181

CH - CA and MH - MA enclosures size.27 EMC version CTE, CTSE *)... 6 poles + m 106 housings and cover for electromagnetic compatibility hoods and cover for electromagnetic compatibility *) only for enclosure CHIS 06 L description part No. entry part No. entry part No. entry part No. entry Pg M Pg M bulkhead housing with lever CHIS 06 L --- surface housing with lever, high construction CAPS 06 L 21 MAPS 06 L32 32 cover with pegs (for enclosures with lever) CHCS 06 L with pegs, side entry, high construction CAOS 06 L21 21 MAOS 06 L32 32 with pegs, top entry, high construction CAVS 06 L21 21 MAVS 06 L32 32 cover with lever (for enclosures with pegs) CHCS 06 LG panel cut-out for bulkhead mounting housings in mm dimensions in mm dimensions in mm ø.5 52 CHIS L 76.5 CAOS L and MAOS L 72.5 32 35 CAPS L and MAPS L CAVS L and MAVS L 7 87.5 max 5 57 CHCS L CHCS LG 12 1