TSTE25 Power Electronics. Lecture 14 Tomas Jonsson ISY/EKS

Similar documents
ABB, November 2012 The high voltage DC breaker The power grid revolution. ABB 07 November 2012 Slide 1

Dr. Brice Koch, Head of Power Systems, Member ABB Group Executive Committee, Hanover April 23, 2012 HVDC a key technology enabler Shaping the

Peter Leupp, Head of Power Systems, ABB Group, Namibia, 11 Nov 2011 HVDC power technology A key enabler for evolving trends

ABB s capabilities in advanced power transmission

HVDC Enabling a stronger, smarter and greener grid

Renewable energy HVDC - the enabling transmission

EPRI s HVDC & FACTS Conf. Oct , 2010, Palo Alto, CA

Peter Lundberg, Product Manager HVDC Light, Guangzhou, Sept New Solutions for Transmission Systems HVDC Light ( 轻型直流 )

Offshore Wind Connections HVDC for Offshore Grids

Peter Lundberg, ABB HVDC, Nov 2016 HVDC Light - Power from shore. ABB Group November 16, 2016 Slide 1 1JNL A

Drivers, Building Blocks (Cables, Offshore), EU and US Examples, Grid- Enabled HVDC, LCC-MTDC

Dr.-Ing. Ervin Spahi, Wadden Sea Forum, Bremerhaven Electric grid on and off-shore: current status, obstacles and new developments

ABB Roger Rosenqvist: August 30, 2012

Creating a secure and undistorted European energy market

MAXWELL PINTO, MSc, AUGUST ABB High Voltage Direct Current The Future of HVDC in South America

ABB Wind Power Solution

Peter Lundberg, Global Product Manager, November 2016 ABB Power Systems Offshore wind connection

HVDC Solutions. for Integration of the Renewable Energy Resources. Marcus Haeusler HVDC Lead Engineer. siemens.com/energy/power-transmission

Power Systems On the growth path

HVDC Innovative Technology for Smart Grids and Super Grids. Wilfried Breuer CEO Power Transmission Solutions, Siemens Energy Sector

Raphael Görner, Head of Marketing & Sales, Grid Systems Germany Building bridges with HVDC Solar Energy for Science

Chapter 1. Overview of HVDC applications

Mikael Dahlgren, ABB Corporate Research, 02 December 2011 ABB Technology providers perspective Energidagen Chalmers Energyinitiative

Drivers, Building Blocks (Cables, Offshore), EU and US Examples, Grid- Enabled HVDC, LCC-MTDC

REFERENCE LIST. HVDC Classic Thyristor valve projects

ABB Group August 27, 2010 Slide 1

HVDC-Flexible in China. Sep

Offshore Wind: Grid Connection & Technology Options. Dietmar Retzmann Focus on. CO 2 Reduction Green Energy Megacities Security of Supply

Power Electronics for Medium Voltage Grid Applications Topologies and Semiconductors

Gunnar Asplund HVDC R&D Manager Sweden. Latest HVDC Light developments. IEEE Montreal

HVDC Technology & Applications

HVDC Technology. Phil Sheppard Head of Network Strategy

CMU Electricity Conference, 9th March 2011

Modern Power-Electronic Converters for High-Voltage Direct-Current (HVDC) Transmission Systems

Modular Multilevel Submodules for Converters, from the State of the Art to Future Trends

What can HVDC Light do for you it s time to connect Applications Key Components

Enabling the power of wind. Competence and expertise for wind power customers

High Voltage Direct Current Systems

HVDC Classic - Reference list

Power From Shore: An introduction to HVDC Light Offshore

The Smart Way. HVDC PLUS One Step Ahead. Answers for energy.

HVDC POWER FROM SHORE. B. WESTMAN* K. ERIKSSON* G. PERSSON* A. MÆLAND** ABB Sweden*, Norway**

ECE 421 Project 1, Group 3 HVDC. Brian Beilstein, Robert Germick, James Haney, Alexander Joss, Matt Murphy, Shutang You

Ambra Sannino, ABB FACTS, May 2011 Keynote Speech PCIM 2011 The Role of Power Electronics in Smart Grids and Renewable Integration

Power Engineering - Egill Benedikt Hreinsson. Lecture 15a. HVDC Transmission. 2 November 2011

Long distance bulk transmission

Grid Integration of Large Scale Wind and Solar

Introduction CONTENT Future of offshore wind energy in Europe Offshore wind energy in Spain Alternatives to the transmission system to the grid Compar

High-Voltage, High-Current DC- DC Converters Applications and Topologies

IEEE PES General Meeting, Minneapolis, July 25-29, 2010 HVDC & FACTS Subcommittee. latest Technology Developments and Projects Dietmar Retzmann

HVDC Transmission: Part of the Energy Solution? Peter Hartley Economics Department & James A. Baker III Institute for Public Policy, Rice University

HVDC links in AC power system

High Voltage Direct Current and Alternating Current Transmission Systems Conference. August Nari Hingorani

ABB Next Level Big shift in power attractive opportunities

MVDC PLUS Managing the future grid

Life Needs Power, Hannover Messe 2017 Inertia in Future Electrical Power Systems Challenges and Solutions Dr. Ervin Spahic

Transmission Grid Reinforcement with Embedded VSC-HVDC. Jonatan Danielsson, Sugam Patel, Jiuping Pan, Reynaldo Nuqui

Smart Grid, Long term planning for a sustainable energy system, from source to socket

The Smart Way HVDC PLUS One Step Ahead Answers for energy.

Power Transmission Solutions Grid Access

ABB Power Electronics - February 8, IEEE PES meeting in Chicago BESS Overview - Components, Drivers, Applications

Getting Smart Evolution to the Smart Grid April 2008

SVC Light For electrical transmission grids

POWER TRANSMISSION OF LOW FREQUENCY WIND FIRMS

The Role of Offshore Wind

Diversifying into Marine Energy. ABB March 2015

Innovative technologies ready for the Supergrid

REFERENCE LIST. HVDC Light The original VSC technology

Cables Connect, cover and forget

Next Generation of UHVDC System. R. Montaño, D Wu, L. Arevalo, B. Jacobson ABB - HVDC Sweden

Experience on Technical Solutions for Grid Integration of Offshore Windfarms

Offshore Wind Farm Projects

Paradigms in Power System Planning & Operation Contemplating the HVDC Technological Evolution

ABB POWER SYSTEMS CONSULTING

The Application of Power Electronics to the Alberta Grid

SPIRO SOLUTIONS PVT LTD POWER ELECTRONICS 1. RENEWABLE ENERGY PROJECT TITLES I. SOLAR ENERGY

Power Flow Control in Meshed DC Grids. 29_03_17 Dr Jun Liang Cardiff University

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

Dr. Chengxiong Mao,Professor School of Electrical and Electronic Engineering Huazhong University of Science and Technology (HUST) P. R.

Benefits of HVDC for System Interconnection. Energy Sector

Targeted Application of STATCOM Technology in the Distribution Zone

ABB Wind Industry Sector Initiative Greengrowth Tallinn, 16 September 2011 Cutting-Edge Wind Energy Solutions Challenges and Solutions ABB Viewpoint

Ukujima Photovoltaic Park 400 MW Stable Integration of a 400MW Photovoltaic Farm into the Japanese Power System Challenges and Chances

ABB in Wind &Integration of renewables

Power Transmisson Division Erlangen, April 15, Siemens receives major order for BorWin3 North Sea grid connection from TenneT

Generation equipment cost in nominal $ million, at purchase price, at installed cost and % share of capex, World, 2000 to 2020

Cigre SC B4 Activities Towards HVDC Grids. HVDC Grid Workshop Belgium

Medium voltage drive for single or multimotor applications, 3 27 MW

Experience on Realizing Smart Grids. IEEE PES conference, Gothenburg

TSTE25 Power Electronics. Lecture 4 Tomas Jonsson ISY/EKS

Karl Elfstadius, ABB Smart Grid Program Mmanager / SMART GRID TAIWAN, Smart Grid Overview. ABB SG_Presentation_V4.

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group April 17, 2009 Slide 1

India Smart Grid Week, 2017

Prospects of HVDC and FACTS for Sustainability and Security of Power Supply

Planning and Operation of the North Sea Grid

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group May 15, 2013 Slide 1

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

An overview of HVDC market and future outlook. Saqib Saeed Principal Analyst Power Technology Research LLC (PTR)

Tibin Joseph Marie Curie Early Stage Researcher Institute of Energy Cardiff University

APPLICATIONS: TECHNOLOGIES: KEY MARKET FORECASTS: GEOGRAPHIES:

Transcription:

TSTE25 Power Electronics Lecture 14 Tomas Jonsson ISY/EKS

Outline HVDC Introduction Classic HVDC Basic principles VSC HVDC Basic principles VSC in the power grid - Wind applications VSC in the power grid - DC-grid applications

HVDC Introduction

Electric Power Systems What is the purpose of the electric power system? Why is the system based on AC power? When is DC power preferred or needed?

Market drivers for HVDC transmission Environmentally friendly grid expansion Integration of renewable energy Remote hydro Offshore wind Solar power Grid reinforcement For increased trading Share spinning reserves To support intermittent renewable energy

Tackling society s challenges on path to low-carbon era means helping utilities do more using less 16,500 12,500 20,000 29,000 30,000 Terawatt-hours (TWh) 20,000 10,000 Forecast rise in electricity consumption by 2030 Source: IEA, World Energy Outlook 2009 +76% Others NAM Europe India China Solutions are needed for: Rising demand for electricity more generation Increasing energy efficiency - improving capacity of existing network Reducing CO 2 emissions Introduce high level of renewable integration 2007 2015 2030 Meeting the rise in demand will mean adding a 1 GW power plant and all related infrastructure every week for the next 20 years

IEA World Energy Outlook 2012-2035 5 890 GW of capacity additions (> the total installed capacity in 2011) is required One third of this is to replace retiring plants; the rest is to meet growing electricity demand. Renewables represent half : 3000 GW. Gas 1400 GW. The power sector requires investment of $16.9 trillion, ca. half the total energy supply infrastructure investment Two fifths of this investment is for electricity networks, while the rest is for generation capacity. Investment in generation capacity, > 60% is for renewables: wind (22%), hydro (16%), solar PV (13%).

The evolution of grids: Connect remote renewables Europe & Germany are planning large scale VSC-HVDC 1 2 3 4 Source: DG Energy, European Commission 1 2 3 1 4 European Visions Hydro power & pump storage -Scandinavia >50 GW wind power in North Sea and Baltic Sea Hydro power & pump storage plants - Alps Solar power in S.Europe, N.Africa & Middle East Germany (draft grid master plan) Alternatives to nuclear-distributed generation Role of offshore wind / other renewables Political commitment Investment demand and conditions Need to strengthen existing grid ABB Group December 20, 2016 Slide 8

Customers Grid Customers Grid Customers Grid Customers Grid What is an HVDC Transmission System? HVDC Converter Station > 6400 MW, Classic Overhead Lines Two conductors HVDC Converter Station > 6400 MW, Classic Hydro Alt. Submarine cables Solar Solar HVDC Converter Station < 1200 MW, Light Land or Submarine cables HVDC Converter Station < 1200 MW, Light Power/Energy direction

Transmission capacity (MW) The transmission grid becomes increasingly important Continued development of AC and DC technologies Different technologies :Same power transmitted Traditional overhead line with AC 6,000 4,000 2,000 HVDC Classic 800 600 Voltage kv 200 1000 800 400 HVDC Light Losses % 3 1 Overhead AC line with FACTS* 1970 1990 2010 Capacity up 6x since 2000; Voltage up from +/- 100kV to +/- 800kV since 1970 2000 Capacity up 10x ; losses down from 3% to 1% per converter station since 2000 2010 Longer transmission distances HVDC (high voltage direct current) Classic overhead line Underground line with HVDC Light or AC cable More power - lower losses - reduced cost per megawatt (MW) Development of power electronics, cable and semiconductor technology

Why HVDC is ideal for long distance transmission? Capacitance and Inductance of power line Transmission Capacity [MW] Transmission Capacity [MW] ABB Group In cable > 50 km, most of AC current is needed to charge and discharge the C (capacitance) of the cable December 20, 2016 Slide 11 G 1200 1000 800 600 400 200 0 I = I 0 - I C U I 0 0 load G C Cable I C = wcu 0 U L = wli 0 U=U 0 -U L In overhead lines > 200 km, most of AC voltage is needed to overcome the L (inductance) of the line C& L can be compensated by reactors/capacitors or FACTS or by use of DC, which means w = 2pn = 0 AC 500 kv DC ±320 kv AC 345 kv AC 230 kv 0 50 100 150 Length of Cable [km] 5000 4000 3000 2000 1000 Overhead Line HVAC L HVDC load 0 0 200 400 600 800 1000 Length of Transmission Line [km] 800 kv 500 kv 765 kv 500 kv

Investment cost versus distance for HVAC and HVDC Investment Costs Critical Distance Total AC cost Total DC Cost DC terminal Costs AC Terminal costs Variables - Cost of Land - Cost of Materials - Cost of Labour - Time to Market - Permissions - etc. Distance

ABB Group December 20, 2016 Slide 13 More than 50 years ago ABB broke the AC/DC barrier Gotland 20 MW subsea link 1954

ABB s unique position in HVDC In-house converters, semiconductors Key components for HVDC transmission systems Converters High power semiconductors HV Cables Conversion of AC to DC and vice versa Silicon based devices for power switching Transmit large amounts of power- u/ground & subsea 24 April 2012 Slide 14

Cable ship AMC Connector

ABB has more than half of the 145 HVDC projects The track record of a global leader Nelson River 2 CU-project Vancouver Island Pole 1 Rapid City Square Butte Pacific Intertie Pacific Intertie Upgrading Pacific Intertie Expansion Intermountain IPP Upgrade Blackwater Highgate 58 HVDC Classic Projects since 1958 14 HVDC upgrades since 1990 19 HVDC Light Projects since 1997 Châteauguay Outaouais Quebec- New England EWIC English Channel Dürnrohr Sardinia-Italy Sapei Cross Sound Mackinac Eagle Pass Sharyland Rio Madeira Itaipu Inga-Shaba Caprivi Link Hällsjön Troll 1&2 Troll 3&4 Skagerrak 1-3 Skagerrak 4 Valhall NorNed Konti-Skan Tjæreborg BorWin1 DolWin1 Dolwin 2 Apollo Upgrade Cahora Bassa Brazil-Argentina Interconnection I&II Italy-Greece Chandrapur Phadge Vizag II Rihand-Dadri Vindhyachal North East Agra FennoSkan 1&2 Estlink Gotland 1-3 Gotland Light NordBalt SwePol Baltic Cable Kontek Hülünbeir- Liaoning Lingbao II Extension Three Gorges-Changzhou Three Gorges-Shanghai Sakuma Gezhouba-Shanghai Xiangjiaba-Shanghai Jinping - Sunan Three Gorges-Guandong Leyte-Luzon Broken Hill New Zealand 1&2 Directlink Murraylink ABB Group December 20, 2016 Slide 16

Development of HVDC applications HVDC Classic Very long sub sea transmissions 580 km Very long overhead line transmissions Very high power transmissions HVDC Light Offshore power supply Wind power integration Underground transmission DC grids

HVDC Technologies Hydro Solar Solar HVDC Classic Current source converters Line-commutated thyristor valves Requires 50% reactive compensation Converter transformers Minimum short circuit capacity > 2x converter rating HVDC Light Voltage source converters Self-commutated IGBT valves Requires no reactive power compensation Standard transformers No minimum short circuit capacity, black start

Classic HVDC basic principles

AC and DC transmission principles Power Direction HVAC X ~ ~ E 1 d E 2 0 HVDC ~ U d1 U d2 R E 1 d E 2 0 ~ Power flow independent from system angles

HVDC - Controllability of power flow Normal Power direction: Power reversal: Pd1 1W Pd2 1W ~ +100 kv +99 kv 1kA Rectifier Inverter ~ ~ -99 kv -100 kv 1kA Inverter Rectifier ~ U d1 U d2 R d I d P d1 P d2 100 99 1 1 100 99 101 99 1 2 202 198 Fast and stable power flow control -99-100 1 1-99 -100

Principles of AC/DC conversion, 6-pulse bridge Id U R IR R 1 3 5 US IS S Ud UT IT T 4 6 2 U RT U ST U R U S U T 1 6 1 2 3 2 3 4 5 4 5 6 wt

Relation between firing delay and phase displacement (a) 0 i a1 e a i a wt Ea Ia1 (b) 30 I d Ea Ia1 (c) 60 Ea I a1 Ea (d) 90 I a1 Ea (e) 120 Ia1 Ea (f) 150 Ia1

Classic HVDC, Active vs Reactive Power How the Reactive Power Balance varies with the Direct Current for a Classic Converter... QQ 0,5 converter Shunt Banks Harmoni Harmonic c Filters 0,13 Classic converter filter filter converter filter unbalance unbalance 1,0 I unbalance d unbalance I d

Baltic Cable 600 MW HVDC link L36994

The HVDC Classic Monopolar Converter Station Converter station Transmission line or cable Converter Smoothing reactor AC bus DC filter Shunt capacitors or other reactive equipment AC filters Telecommunication ~~ Control system

Monopolar Converter station, 600 MW AC line AC Switchyard Converter Transformers Valve Hall DC line Shunt Capacitors Harmonic Filters Approximately 80 x 180 meters DC Switchyard

Longquan, China HVDC Classic

VSC HVDC basic principles

Introduction 1. Why VSC HVDC Particular advantages with VSC HVDC 1. Voltage source functionality U v U v amplitude adjustable phase angle frequency Rapid, independent control of active and reactive power No need for a strong grid

Introduction 1. Why VSC HVDC Particular advantages of VSC HVDC 2. Power direction reversal through DC current reversal P 3 + U d - I d 3 Lightweight, less expensive, extruded polymer DC cables can be used Extruded plastic cable Mass impregnated oil cable

Introduction 1. Why VSC HVDC Particular advantages of VSC HVDC 3. Pulse width modulation of AC voltages Small filters, both on AC and DC side

VSC HVDC basic principles U d 2. VSC converter topologies U d Two-level voltage source converter. Converts a DC voltage into a three-phase AC voltage by means of switching between two voltage levels. U d U d Basic operation of a phase leg: + U d + U d + U d u i u i u i - U d - U d - U d + U d - U d u i t

VSC HVDC basic principles 2. VSC converter topologies Multilevel topologies - basics + Phase voltages are multi-level (>2). + Pulse number and switching frequency are decoupled. + The output voltage swing is reduced less insulation stress + Series-connected semiconductors can be avoided for high voltage applications - More complicated converter topologies are required - More semiconductors required Typical applications: high-power converters operating at medium or high voltage. 1 2 levels 0-1 0 1 2 3 4 5 6 1 3 levels 0-1 0 1 2 3 4 5 6 1 5 levels 0-1 0 1 2 3 4 5 6 1 7 levels 0-1 0 1 2 3 4 5 6

VSC HVDC basic principles 2. VSC converter topologies Multilevel converter topologies Neutral point clamped (NPC) topologies Flying capacitor topologies Cascaded topologies Modular Multilevel Converters (MMC) Half-bridge and full-bridge variants Module N Ud,m U d U d Module 2 Module 1 Ud,m U d U d U d Ud,m Module N Ud,m Module 2 One phase leg, or equivalent, shown in each case Module 1

VSC HVDC basic principles Modular multi-level converter (MMC) Modular multi-level converter (MMC) Prof. Marquardt, Univ. Munich Module N Ud,m Ud,m Ud,m DC capacitors distributed in the phase legs DC capacitors handle fundamental current Scalable with regard to the number of levels Twice the total blocking voltage required (twice no of semiconductor devices) compared to two-level converter Redundancy possible by shorting failing cells Module 2 Module 1 Ud,m Ud,m Ud,m Ud,m Ud,m Ud,m DC terminal Module N Ud,m Ud,m Ud,m Module 2 Ud,m Ud,m Ud,m Module 1 Ud,m Ud,m Ud,m AC terminal

VSC HVDC basic principles MMC-converter, switching principle +U d D1 T1 C I vpa I vpa L v D1 T1 C D2 T2 I v D2 T2 U cp1a U v L v I vna C D1 T1 U cp1a D2 T2 C D1 T1 D2 T2 Three operating states of the converter cell: Bypass mode. Cell capacitor is bypassed. (Green curve) Inserted mode. Cell capacitor is inserted and giving contribution to converter output voltage Blocked mode. All IGBTs non-conducting -U d

Uv(t) [kv] VSC HVDC basic principles MMC-converter, Output voltage Third harmonic modulation 300 M9 version 2.2, 320kV, M2LC, P=3.37, N=35, C=1mF, no 2nd harm + 1 2 Cell 200 100 n 0-100 -200-300 0 0.002 0.004 0.006 0.008 0.01 0.012 0.014 0.016 0.018 0.02 time s VSC Toolbox version 2.4. 05-Dec-2008 10:22:05 n 2-1 ABB Group Slide 38 PowDoc id

VSC performance Switching Principle Uvalve Uvalve 2-level ±150 kv dc MMC ±320 kv dc

VSC performance Converter currents Ivp Itfosec Iv Iv Ifilt 2-level MMC No filters required

VSC performance Valve voltages and currents Iigbt1 Idiod1 Uigbt1 Udiod1 2-level Reduced losses MMC

HVDC Light Generation 4 Double cell 8.. 2 1 1-8 2,200 1-8 1-8 1-8 (mm) 2,000 1660 1,600 Mass 3,000 kg

IGBT Module

IGBT inner structure

HVDC Light - valve design Short Circuit Failure Mode (SCFM) ABB press pack valve design Valve control The press-pack IGBTs used by ABB are designed to withstand operation in a 2 short-circuited state. Non press-pack devices that are not designed for 1 transmission applications may fail uncontrollably (explosion resistant housing required). 4,5 kv, 2000 A 1. Safe short-circuit at single module fault 2. Press-pack IGBT designed to withstand line-to-line DC fault 3. Same short-circuit failure mode as the well-proven press pack for thyristors

HVDC Light Generation 4 Valve arm + -

Typical converter layout 700 MW

Typical converter layout 700 MW

HVDC Light Generation 4 Station layout 2 x 1000 MW 320 kv 150 m 220 m

VSC in the power grid Wind applications

Offshore Wind Power Connectors Planned installations Europe Wind farms increase in size. Most of them above 300 MW. Larger farms will require massive delivery of AC-cables, both export cables and array cables Longer distance from shore and increased size favors HVDC connectors (planned up to 1100 MW)

Offshore Wind Power Connectors Technology, AC or DC-connectors AC is the traditional technology AC DC (HVDC) is required for long distances (>50-100 km) or higher power ratings (>300 MW) Capex - reduced cable and cable installation cost. Opex - reduced power losses over long distances DC Capacity - several wind farms connected to a plug at sea Reliability - grid code compliance, power control, stability and black start capability Flexible - enables long distance underground connection to main AC grid Environmental - reduced subsea cable trenching, no magnetical fields, no oil in XLPE cable, no overhead lines

Overview Offshore AC wind power connectors Reactive Compensation Wind farms 24-72 kv Collection grid Offshore AC substation 72-245 kv Subsea cable Onshore AC substation Main AC network 50 300 MW: 72-150 kv 200 500 MW: 150-245 kv Traditional AC-substations located off-shore Key issue is to fulfill grid code compliance (Longest AC subsea cable is the Isle of Man connector 104 km, 90kV / 40 MW)

Overview Offshore HVDC wind power connectors Large Wind farms Offshore AC platform Offshore HVDC Light DC cable transmission Onshore HVDC Light Main AC network 100 300 MW: ± 80 kv HVDC Light (VSC) 300 500 MW: ± 150 kv HVDC Light 500 1000 MW:± 320 kv HVDC Light VSC technology for compact solutions. ABB with 10 years experience ( 13 references)

Windpower Control Aspects

Basic Control Principle. Voltage Source Converter U v U v adjustable amplitude phase angle frequency

z) y (kv) y y (kv) (ka) y y (ka) (kv) y (MW,Mvar) y (deg) y (Hz) y (kv) Converter energization 0.0 F2 53.0 PCC1 154 kv Offshore station Station 1 47.0 100 Onshore station Station 2 Phistn2 PCC2 380 kv Wind Park Offshore main breaker 1. Auxiliary power connected. Cooling system running. 2. On-shore ac breaker closed to energize transformer, filter and converter 3. On-shore converter deblocked. DCvoltage control active -100 500-100 400 1.50 200-1.50 2.00 400 Pstn2 udcc2 Istn2_active Onshore station Qstn2 Diele breaker Diele Grid Istn2_reactive DC-Voltage idcp2 upcc2a upcc2b upcc2c AC-Voltage -2.00-400 Ustn2 4000.00 0.50 1.00 1.50 2.00 2.50 3.00 0.0 53.0 F2

ua,ub,uc (kv) ua,ub,uc (kv) Off-shore grid energization PCC1 154 kv Offshore station Station 1 Onshore station Station 2 PCC2 380 kv Wind Park Diele Grid Offshore main breaker 1. Off-shore converter deblocked. ACvoltage control active. 2. Smooth ramp-up of ac-voltage. 3. Off-shore main breaker closed. 4. Windpark transformers energized 5. Wind-turbines synchronized and connected 400 200 0-200 -400 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 400 200 0-200 Diele breaker -400 0.45 0.5 0.55 0.6 0.65 Time (seconds)

Normal operation PCC1 154 kv Offshore station Station 1 Onshore station Station 2 PCC2 380 kv Wind Park Diele Grid Offshore main breaker Diele breaker 1. Off-shore converter in voltage and frequency control. 2. On-shore converter in dc-voltage and reactive power control. 3. Windpark power reduction, 4. Off-shore converter power (P1) drops, since acvoltage control results in power tracking 5. Instantaneous dc-power unbalance (P1-P2) < 0 dc-voltage drop 6. On-shore dc-voltage control quickly reduces power (P2) to restore nominal dc-voltage and power balance. P1 (offshore) U DC P2 (onshore) time

Automatic windpower dispatch PCC1 154 kv Offshore station Station 1 Onshore station Station 2 PCC2 380 kv Wind Park Diele Grid Offshore main breaker Diele breaker 1. Off-shore converter in voltage and frequency control. 2. Power reduction ordered by on-shore grid operator (or frequency control) 3. Off-shore converter increases off-shore grid frequency 4. Wind turbine control responds to the frequency increase by power reduction (98% per Hz) 5. Off-shore converter power (P1) drops, since acvoltage control results in power tracking 6. On-shore dc-voltage control quickly reduces P2 to restore nominal dc-voltage and power balance. Windpark power P1 ref frequency (off-shore) time

Isolated generation, grid fault without fault ride through Control of: U1, f1 Control of: Ud, Q1 Control of: U2, f2 u DC1 u DC2 P1, Q1 P2, Q2 U DC P2 P1 AC-voltages U2 U1

Fault ride through with chopper Control of: U1, f1 Control of: Ud, Q1 DC chopper: Udmax Control of: U2, f2 u DC1 u DC2 On-shore P1=f(U dc1 ) Q1 Pch With DC chopper U DC P2 P2, Q2 Off-shore Pch P1 DC-chopper decouples windpark from onshore grid Minimum impact on wind production during on-shore grid faults

Chopper resistors

Example of offshore platform layout Crane Helipad Transformers Topside Piles Jacket J-Tubes

Jacket

Topside

Transport of Jacket + Topside

Jacket installation

Topside placed on jacket

Final platform

Borwin 1, Dolwin 1 & 2 Offshore Point-to-Point Why HVDC Light: Length of land and sea cable Main data Borwin 1 Dolwin 1 Dolwin 2. In operation: 2010 2013 2015 Power rating: 400 MW 800 MW 900 MW AC Voltage Platform: 170 kv 155 kv 155 kv Onshore 380 kv 380 kv 380 kv DC Voltage: ±150 kv 320 kv 320 kv DC underground cable: 2 x 75 km 2 x 75 km 2 x 45 km DC submarine cable: 2 x 125 km 2 x 90 km 2 x 90 km DOLWIN1: efficiently integrating power from offshore wind DOLWIN alpha platform loadout

VSC in the power grid DC-grid applications

HVDC Grids Why? Regional to continental HVDC Grids Offshore wind Solar Hydro Why HVDC Grids vs HVDC single links Only relevant offshore solution (DC-cables) Loss reduction Increased power capacity & availability combined with the AC-system Less visual impact & easier permitting (DC-cables) Why now: Offshore wind, remote solar, grid constraints HVDC Light systems and components mature Challenges: DC-fault clearing strategies DC overhead lines Regulatory framework

The evolution of grids: Connect remote renewables Europe & Germany are planning large scale VSC-HVDC 1 2 3 4 Source: DG Energy, European Commission 1 2 3 1 4 European Visions Hydro power & pump storage -Scandinavia >50 GW wind power in North Sea and Baltic Sea Hydro power & pump storage plants - Alps Solar power in S.Europe, N.Africa & Middle East Germany (draft grid master plan) Alternatives to nuclear-distributed generation Role of offshore wind / other renewables Political commitment Investment demand and conditions Need to strengthen existing grid ABB Group December 20, 2016 Slide 74

Multi-terminal operation Control of: U1, f1 Control of: Ud, Q1 Control of: P2, Q2 Control of: U2, f2 u DC1 u DC2 P1=f(U dc1 ) Q1 P2, Q2 U D P3 P2 P1 Control of: P3, Q3 P3, Q3 Control of: U3, f3 One converter station maintains a constant dc voltage (left), while the other two (right) converter operates at independant power reference given by system operator.

Protection philosophy Line fault handling Separation without interruption Breaker layouts x x x Primarily fast protection together with fast DC breakers isolate the faulty line. x Fast DC breakers

Hybrid DC Breaker is well suited for HVDC grids Fast: Breaking times of less than 2ms Powerful Current breaking capability of 16kA Efficient Transfer losses are less than 0.01% Modular Easily adapted to actual voltage & current ratings Reliable Protective current limitation, functional check while in service Proven Power electronic design similar to converter technology DC Breakers are no longer a showstopper for large HVDC grids

Hybrid DC Breaker Fast breaking within time delay of selective protection Normal operation: Current flows in low-loss bypass Proactive control: Load commutation switch transfer current into Main Breaker switch, the Ultra Fast Disconnector opens with very low voltage stress Current limitation: Main Breaker switch commutates fault current into parts of the sectionalized arrester bank Fault clearance: Main Breaker switch commutates fault current into arrester bank

www.liu.se