PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

Similar documents
Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

34-SDMS-01 SPECIFICATIONS FOR

T YPE MZ DISTRIBUTION S TANDARD CUTOUT

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

شركة كهرباء محافظة القدس المساهمة المحدودة

Figure 1. HX cutout fuseholders. Positive Interruption

Figure 1. HX cutout fuseholders.

T HREE-SHOT TYPE MZR F USE CUTOUT

TYPE BLT DISCONNECT SWITCHES

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

S&C Recloser Bypass Disconnects

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A October 2015

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A January 2014

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)

GROUP D. Switch & Protective device.

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

MGVCL//11KV D.O.FUSE/SPECIFICATIONS -:11KV DROP OUT FUSE CUTOUTS:-

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

Type ICX Interchangeable Cutout kv Outdoor Distribution Cutout Product Bulletin 1VAG DB

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

Type ICX Outdoor open type cutout

Disconnect & ByPass Switches

S&C Loadbuster Disconnects

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA March 2013

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA August 2015

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana 47401

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.

TECHNICAL SPECIFICATION FOR 11 KV DROP OUT (D.O.) FUSE with Polymeric Insulators:

WESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO. GUARANTEED TECHNICAL PARTICULARS 1 of 2

CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B

045 : 2000 CEB STANDARD

PRODUCT CATALOGUE. Overhead System

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

OVERHEAD DISTRIBUTION SWITCHES

NOTE: Because Hubbell has a policy of continuous product improvement, we reserve the right to change design and specifications without notice.

Specifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv)

Catalog 14A January 2013

: DGVCL/11KV D.O.FUSE/SPECIFICATION : : 11KV DROP OUT FUSE CUTOUTS :

Product Specifications for Aluminum Vertical Break Switches

RBA Catalog Numbers and Information

Cutouts (Standard, Linkbreak & Loadbreak) and Cutout-Arrester Combinations U.S. Patent 4,546,341; 6,392,526

TYPE V CENTER BREAK SWITCH

Medium Voltage Capacitors

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Technical Specification for Pole Mounted Capacitor Rack

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

Technical Specification For Outdoor Substation Harmonic Filter Banks

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

Electronic Resettable Sectionalizer

Product Specifications for Phase Over Phase GOABS(r)

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Load Break Switch Type LBOR-II, Oil Immersed PTAT-LIR975 IZUA Technical Guide Nut Mount Weld Mount

TABLE OF CONTENTS FOREWORD... 2 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3

43-SDMS-04 REV. 00 SPECIFICATIONS FOR

JUMPERS & SWITCHING TOOLS

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

K-Limiter high ampere Companion II fuse

Air-insulated switchgear UniGear type ZS1

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

AutoLink Frequently Asked Questions

Range : 20A, 32A, 63A & 100A in front connection, bus bar connection & rear connection versions.

Jumpers & Load Pickup Tools

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

3.0OVERHEAD TRANSMISSION SWITCHES

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

2.7. Expulsion Fuses. Contents. RBA/RDB Type Fuses (Including Superseded BA Fuses) RBA/RDB Type Fuses (Including Superseded BA Fuses)

DAQO Technical Differences of Isolated Phase Bus Standards. Study of Design Standard Variances, Insulator Design and Shipping Section Design

SPECIFICATION BULLETIN

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

Boric Acid Fuse Links

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

Q pole Pole Mounted Capacitor System

Medium Voltage Metal-Enclosed Switches

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

SURGE DURABILITY AND IMPROVED TRANSFORMER PROTECTION

Kuhlman Electric Corporation Volt Instrument Transformers

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

S&C Type XS Fuse Cutouts

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

EMPAC Metal enclosed capacitor bank for wind applications

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV

2.7. Expulsion Fuses. Contents. RBA/RDB Type Fuses (Including Superseded BA Fuses) RBA/RDB Type Fuses (Including Superseded BA Fuses)

LG HRC Power Fuses ISO 9001 ISO 14001

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

Transformer bushings, type GOH. Technical guide

S&C Type XS Fuse Cutouts

POWER SYSTEMS, INC. CUTOUTS (Standard, Linkbreak & Loadbreak) and CUTOUT-ARRESTER COMBINATIONS

Technical Specification

Transcription:

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 38kV 100A 8kA asym. Type PGC Parallel groove terminal bronze with tin plated NEMA Bracket type B Upper contact copper with silver plated Cap - Cast bronze with silver plated On load hook for load buster Insulator One-piece bird proof porcelain Fuse tube with vulcanize bone fiber liner inside fiber glass reinforced epoxy resin which color painting UV resistance Trunnion high strength cast bronze silver plated movable contact Hinge stainless steel for corrosion resistance Feature Maximum voltage design 38kV Rated continuous current 100A Drop down open fuse cutout Non expendable cap Single vent expulsion fuse holder Single core bird proof of porcelain for fuse cutout body Off load operation but have hook for on load by load buster Apply for protection over current and fault of distribution line and distribution equipment such as power transformer, current transformer or capacitor bank etc. Spring latch (No visible) to prevent open fuse holder from vibration Type test report PRECISE INTERNATIONAL CORPORATION LTD. Sale Office: 1842 Krungthep-Nonthaburi Rd., Bangsue, Bangkok, 10800 Thailand Telephone: (662) 910 9700-12 Telefax: (662) 910 9713-4 Website: www.precise.co.th E-mail: info@precise.co.th April 2007: Rev.1

PRECISE PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 38kV 100A 8kA asym. Type PGC Type PGC Cutout dimensions with NEMA Bracket Type B Dimensions Data A B C D E 658 217 349 366 770 In millimeters unit Performance Characteristics Applied standard ANSI C37.42 Catalog number 3810865 Nominal system voltage kv-rms 33 Maximum voltage design kv-rms 38 Dry withstand voltage kv-rms 70 Wet withstand voltage kv-rms 60 BIL 1.2x50µs kv-peak 150 Continuous current A-RMS 100 Interrupting current asymmetrical/symmetrical A-RMS 8000 / 5000 Frequency Hz 50 Creepage distance to Ground Min. mm 650 Ambient air temperature Up to 40 o C Attitude Up to 1000 m Vertical insulator angle from center line of cutout body 15-20 degree Approximate weight with NEMA Bracket kg. 13 Fuse holder expulsion Non-Expendable cap Factsheet No.: PGP-PGP102-FC-0002 Factsheet: State 3 Issued On : 01/04/2007 Authorized Dealer: Revision No. 0 Date : 01/04/2007

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 27kV 100A 8kA asym. Type PGP Parallel groove terminal bronze with tin plated NEMA Bracket type B Insulator One-piece bird proof porcelain Upper contact copper with silver plated Cap - Cast bronze with silver plated On load hook for load buster Fuse tube with vulcanize bone fiber liner inside fiber glass reinforced epoxy resin which color painting UV resistance Hinge Stainless steel for corrosion resistance Feature Maximum voltage design 27kV Rated continuous current 100A Drop down open fuse cutout Non expendable cap Single vent expulsion fuse holder Single core bird proof of porcelain for fuse cutout body Interchangeability to S&C type XS,AB Chance type C and ABB type ICX Off load operation but have hook for on load by load buster Apply for protection over current and fault of distribution line and distribution equipment such as power transformer, current transformer or capacitor bank etc. Trunnion high strength cast bronze silver plated movable contact Spring latch (No visible) to prevent open fuse holder from vibration Type test report PRECISE INTERNATIONAL CORPORATION LTD. Sale Office: 1842 Krungthep-Nonthaburi Rd., Bangsue, Bangkok, 10800 Thailand Telephone: (662) 910 9700-12 Telefax: (662) 910 9713-4 Website: www.precise.co.th E-mail: info@precise.co.th April 2007: Rev.1

PRECISE PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 27kV 100A 8kA asym. Type PGP Type PGP Cutout dimensions with NEMA Bracket Type B Dimensions Data A B C D E 578 191 301 353 655 In millimeters unit Performance Characteristics Applied standard ANSI C37.42 Catalog number 2710832 Nominal system voltage kv-rms 22 Maximum voltage design kv-rms 27 Dry withstand voltage kv-rms 42 Wet withstand voltage kv-rms 36 BIL 1.2x50µs kv-peak 125 Continuous current A-RMS 100 Interrupting current asymmetrical/symmetrical A-RMS 8000 / 5600 Frequency Hz 50 Creepage distance to ground Min. mm 320 Ambient air temperature Up to 40 O C Altitude Up to 1000m Vertical insulator angle from center line of cutout body 15-20 degree Approximate weight with NEMA Bracket kg. 9 Fuse holder interchangeability * Fuse holder expulsion Non-Expendable cap * Interchange with S&C type XS, AB Chance type C and ABB type ICX Factsheet No.: PGP-PGP102-FC-0001 Factsheet: State 3 Issued On : 01/04/2007 Authorized Dealer: Revision No. 0 Date : 01/04/2007

PRECISE HIGH VOLTAGE FUSE LINKS FUSE LINKS TYPE K Flexible wire : easy to engage with bolt on fuse cutout s trunnion Removable button head can be removed for using with arc shortening rod ARC-extinguishing tube Strain wire prevents fuse element Fuse element Rated current was to be broken from tension force by emboss on flipper latch High Voltage Fuse Links Feature Design and manufacture accordance to ANSI C37.42 Removable button head style for using with arc shortening Use to drop out fuse cutout maximum design voltage 27kV and 38kV High Voltage Fuse Links Drawing Performance Characteristics Ampere PRECISE INTERNATIONAL CORPORATION LTD. Sale Office: 1842 Krungthep-Nonthaburi Rd., Bangsue, Bangkok, 10800 Thailand Telephone: (662) 910 9700-12 Telefax: (662) 910 9713-4 Website: www.precise.co.th E-mail: info@precise.co.th Catalog number C (mm) Min. Ø A (mm) 27kV 38kV 27kV 38kV ±0.5 mm Ø B (mm) ±0.5 mm Ø D (mm) ±0.5 mm Ø F (mm) ±1.5 mm 1 K00127 K00138 661 760 12.7 19.0 2.0 8.0 2 K00227 K00238 661 760 12.7 19.0 2.0 8.0 3 K00327 K00338 661 760 12.7 19.0 2.0 8.0 6 K00627 K00638 661 760 12.7 19.0 2.0 8.0 8 K00827 K00838 661 760 12.7 19.0 2.0 8.0 10 K01027 K01038 661 760 12.7 19.0 2.0 8.0 12 K01227 K01238 661 760 12.7 19.0 2.0 8.0 15 K01527 K01538 661 760 12.7 19.0 2.0 8.0 20 K02027 K02038 661 760 12.7 19.0 2.5 8.0 25 K02527 K02538 661 760 12.7 19.0 2.5 8.0 30 K03027 K03038 661 760 12.7 19.0 3.0 8.0 40 K04027 K04038 661 760 12.7 19.0 3.0 8.0 50 K05027 K05038 661 760 12.7 19.0 4.0 10.0 65 K06527 K06538 661 760 19.0 NO 4.0 10.0 80 K08027 K08038 661 760 19.0 NO 5.0 10.0 100 K10027 K10038 661 760 19.0 NO 5.0 10.0 Note: 1) Button head thread size1/4 ¼ pitch G28 length 7 mm +/- 1 mm 2) For rated current 1, 2 and 3A have only one fuse element instead of strain wire position 3) Washer will be supply only with current rated 1 to 50 Amperes April 2007: Rev.1

PRECISE PRECISE HIGH VOLTAGE FUSE LINKS PRECISE fuse links Time-Current Characteristics Cur ve Factsheet No.: PGP-PGP102-FL-0003 Factsheet: State 3 Issued On : 01/04/2007 Authorized Dealer: Revision No. 0 Date : 01/04/2007

PRECISE LOW TENSION FUSE SWITCH LOW TENSION FUSE SWITCH 400A 500V Metal base is hot dip galvanize malleable iron One piece porcelian insulator Terminal pad bronze with tin plated and 9/16 of hole for conductor Phenolic paper laminate sheet for fuse carrier Contact is copper with silver plate Clamping assemble is stainless steel Pull ring and Lift ring is hot dip galvanize and 26mm diameter for hook sticks Type test report Feature Design and manufacture accordance to IEC 60947-3 Suits HRC fuse bolted connections type size B1 to B4 and blade contacts type size 0 to 2 accordance to IEC 60269-2-1 Single pole Single throw switch Rated maximum voltage 500V and 400A maximum current Suits NEMA PAD 2 Holes terminal Suits standard hook-sticks On-load switching capability PRECISE INTERNATIONAL CORPORATION LTD. Sale Office: 1842 Krungthep-Nonthaburi Rd., Bangsue, Bangkok, 10800 Thailand Telephone: (662) 910 9700-12 Telefax: (662) 910 9713-4 Website: www.precise.co.th E-mail: info@precise.co.th April 2007: Rev.1

PRECISE PRECISE LOW TENSION FUSE SWITCH LOW TENSION FUSE SWITCH Low tension fuse switch dimensions with HRC fuse Dimensions Data A B C D 323 319 203 399 In millimeters unit Performance Characteristics Applied standard IEC 60947-3 Rated operation voltage V-RMS 500 Rated insulation voltage V-RMS 1000 Rated operation current with fuse link A-RMS 400 Rated frequency Hz 50 Rated condition short-circuit current ka-rms 50 Rated impulse withstand voltage kv-peak 12 Rated make-break current at 0.65 PF, 5 operation cycle A-RMS Creepage distance Min. mm 32 Utilization category 600 AC-21B Infrequent operation with current 220* Infrequent operation without current 1400* Degree of protection IP00 Approximate overall weight kg. 2.8 Model *Number of operation cycle at 60 operations cycle hour OFS-4A5 Factsheet No.: PGP-PGP102-FS-0004 Factsheet: State 3 Issued On : 01/04/2007 Authorized Dealer: Revision No. 0 Date : 01/04/2007