FSP Fan Speed Power Module Technical Data

Similar documents
FDB Filter Drier. FDB Filter Drier. Technical Data

ADK Filter Drier. Alco Controls. Filter Drier. Features

FDB Filter Drier. Alco Controls. FDB Filter Drier. Features. Introduction. Moisture removal capability. Construction

BFK Bi-flow Filter Drier

PS1 / PS2 Series Pressure Controls Technical Data

Series P215ST Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Electrical Control Valves

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Electrical Control Valves Series EX4, EX5, EX6, EX7 & EX8

Alco Controls. Components for the Refrigeration Industry. Product Selection Catalogue

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Series P255MM/ML Single/Dual Pressure Input Condenser Fan Speed Controllers For Three Phase Motors (incl. built-in RFI suppression filter)

Emerson Climate Technologies

EMERSON CLIMATE TECHNOLOGIES-EX

Electronic suction modulating valves type KVS

Pressure Transmitters

No.1. Side approach mechanism Precise lateral contacting. Catalogue 1.1. Test Probes Test Fixtures

Pulse Width Modulation Valves. Models SPW-0 thru -7

EX4 / EX5 / EX6 / EX7 / EX8 Electrical Control Valves

Packing Data Installation Instructions

EX3: stepper motor valve with safety embedded solenoid ON/OFF valve

P70, P72, and P170 Series Controls for High Pressure Applications

Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 1 and CTM 2 Liquid Ejector

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

CLIMATE CONTROL SOLUTION

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

8EA SERIES PTC MOTOR STARTERS

PRODUCT CATALOGUE CHILLER ECOMAX

Thermo -Expansion Valves Series TX7

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

EMUJC Series. Electronic actuator. Technical Data Sheet. WattsIndustries.com

Thermostatic Expansion Valve

Thermostats Series 142

Explosion-Protected Pressure Switches

Energy-saving motors (ESM)

Power conversion systems for energy storage. Engineering that stores

MT/MTZ 50 Hz R22 R407C R134a R404A / R507

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

INDUSTRIAL POWER SUPPLIES SFL-SERIES

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 1 and CTM 2 Liquid Ejector

P77 Series. Single Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications. Product Bulletin

Technical brochure Electrically operated expansion valves, type ETS 6

XMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12

VTZ variable speed Reciprocating compressors

LED T8 glass tube 4ft 18W

Pressure Switches 30 A/F

Product Data Sheet HKK70VSD Revision 1 (Variant Code E)

Torque Motors 3 W, 6 W, 10 W, 20 W

Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory)

Magnetic drive pumps A worldwide best-seller, our high-quality compact magnetic drive pumps

HANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1

P r e s s u r e i S w i t c h e s V a c u u m i S w i t c h e s PressureiTransmitters

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12


Introduction. Series P100. Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty. Feature and Benefits

Product Catalogue. Electromechanical controllers REL

P r e s s u r e i S w i t c h e s V a c u u m i S w i t c h e s PressureiTransmitters

FG Series, 230V ac Toroidal Single Primary Transformers

Electric expansion valve Type ETS ETS 400

Fork through-beam sensors

STRATO LED Drivers 70W, Single output

Crankcase pressure regulator Type KVL

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

JUMO MIDAS Pressure transmitter

ACEA Report. Vehicles in use Europe 2017

T Series. The most reliable HVAC system for transit is now better than ever.

PRODUCTS: POWER SUPPLY

VA-7150 Electric Valve Actuator. Features and Benefits. G 500N force output in a compact unit G Magnetic clutch. G Unique Yoke Design

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Crankcase Pressure Regulating Valves

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

Test Probes Test Fixtures INGUN. Test Fixtures for low PCB volumes. Change made easy

Differential Pressure Sensors

Capacity regulators (hot gas bypass) PMC and CVC

Rectangular photoelectric proximity switches

P66 Series Electronic Fan Speed Controls

SOLSTART Instruction Manual

Solenoid valves type EVR 2 40 NC / NO

50Hz ZBD45KCE-TFD R404A Dew Point

Lexium integrated drives

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Electrically Operated Expansion Valve Types AKV 10, AKV 15 and AKV 20

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Data Sheet P4055 Pressure Transducer

Differential pressure sensor

Series P74 Differential Pressure Controls, without time delay

Pressure sensor for liquid and gaseous media QBE620-P...

Pressure switch hex 27

INSTALLATION GUIDE NI WSN-3291 Outdoor IP Enclosure For NI WSN-32xx Series Devices

Crankcase pressure regulator Type KVL

Spain s exports by oil product group and country of destination

10 S e r i e s PRESSURE SWITCH. features

CTE7000 / CTU7000 Series Miniature pressure transmitters

Non-Spring Return EconoDrive Floating Actuator

A-L O C COOLING SYSTEM OLAER COOLERS. Olaer A-LOC with integrated circulation pump for industrial hydraulic systems

Transcription:

PCN: 800 373 Q0337 Signal 0... 10V 230VAC 8A 230VAC 8A FSP Technical Data Electronic Power Modules FSP control the speed of condenser fan motors in commercial refrigeration and airconditioning systems. The necessary input signal of 0 10 V depending on condensing pressure can be generated by the optional Control Module FSE, or other electronic controllers. Features Can be used in combination with ALCO FSE, EC2, EC3 and other electronic controllers which provide a 0 10 V output signal for condensing pressure control Energy saving due to improved cooling efficency Reduced fan noise level during low ambient temp. conditions Improved overall performance of cooling system Versions for 1- and 3-phase Motors Short start impulse to overcome friction and windmilling Easy installation with cables for power supply and motor connection factory wired IP 67 protection for outdoor mounting CE marking (EMC, LVD) Options FSE Control Module for pressure input DIN-rail mouting kit Cable assemblies FSP Power Module Introduction The FSP Power Modules together with FSE Control Modules are designed to control the speed of fan motors depending on condenser pressure. Optional FSP can be driven by other controllers which supply the 0 10V signal, e.g. EC3-75x from ALCO. The FSP can be used in air-cooled condensers, aircooled condensing units and air-conditioning units. FSE-0xx 0-10 VDC FSE-Nxx Condenser FSP-180 M Fan Motor FSP-xxx Using variable fan speed control offers the following benefits for your application (see figure below): Head pressure can be kept high enough to ensure proper operation of the expansion valve, and hence, sufficient mass flow through the expansion valve to feed the evaporator. This maintains the required cooling capacity. Compared to on-off cycling of fan motors during low ambient conditions the continuous fan control maintains lowest possible head pressure, see figure below. This improves COP of compressors along with the according energy savings, more stable suction pressure and a positive impact on the overall performance of the cooling system. The noise level of fan motors can be reduced to a minimum by avoiding permanent on/off cycling. Receiver Main power Condensing pressure pressostat control Evaporator FSP have EMC-filters installed and comply with EC-Directive 89/336/EC (electromagnetic compatibility requirements of the European Community). continous control off on off on Time FSPE_35050_EN_R06.doc 1 / 8 25.07.2007

5A 5A FSP Operation The behaviour of FSP together with FSE can be described by the control diagram figure right. The top curve describes the fan speed at decreasing, the lower curve at rising pressure. At high condensing pressure fan is running with maximum speed (top right). In the proportional range of the curve fan speed is decreased with pressure. If the pressure falls below the specified limit the fan is switched off (cut-off point in the curve). A large hysteresis is built-in to prevent fan cycling at this point. Pressure must increase by approximately 1 bar before fan restarts. A short start pulse helps fan to overcome friction or windmilling before it supplies the proportional value. Along the proportional range the fan speed varies between 20% and 100%, 3-phase motors respectively 30% and 100% for single phase motors. Output Voltage Fan Speed Cut-off Control Diagram Hysteresis Proportional range Maximum Speed Condensing Pressure (bar) or Input Voltage: 0... 10 V Electromagnetic Compatibility FSP series is CE-marked and conforms to the requirements of EC-Directive 89/336/EEC as long as it is correct installed according to the operation instructions. It should be considered that when two or more EMC compliant components are combined in the same system the resulting system may not be compliant. The FSP was tested for emissions according EN 55014-1:2000, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6 and EN50082-1. Motor The performance of fan motors used with the FSP Power Module can vary. An important factor is the ratio between starting- and nominal current. The start-up current of motors is much higher than the nominal current at full speed. Single phase motors with Steinmetz capacitor typically consume 20% more current during partial speed than the specified nominal current. The cooling of fan motors is less efficient at low speed. Both effects together can warm-up motors more than under full load conditions. It is therefore imperative to ensure that motor protection is wired correct. Important note: FSP should only be used with fans released by manufacturer for speed control by means of phase-cut (see the respective fan motor datasheet). Single- and 3-phase Motors Single phase Motors very often have the same mechanical construction than 3-phase motors. The main power is connected to 2 of the 3 terminals. A capacitor is used to generate the phase-shift on the 3 rd terminal (Steinmetz wiring). Due to this unsymmetrical construction principle single phase motors have a much lower start-up torque compared to 3-phase motors. Paralleling of Fan Motors FSP Power Modules allow paralleling of several fan motors, as long as the sum of the motor currents does not exceed the maximum operating current of the module. Paralleling of Fan Motors FSE-02S FSP- M 230VAC FSP-150 P CN: 800 370 Q0337 230VAC Signal 0... 10V Power Supply FSE 0... 10VDC FSPE_35050_EN_R06.doc 2 / 8 25.07.2007

Product Combinations Selection 1. Select a Power Module FSP by the total maximum operating current and phases of condenser fan motors. Signal Section Connector Section Power Section 2. Select a Control Module FSE based on the pressure requirements of the refrigerant used: FSE-01S for R 134a, FSE-02S for R 22 / R 407C / R 507 FSE-03S for R 410A 3. Select a Cable Assembly a) for connection of FSE to FSP: 3 lenghts: (1.5-3.0-6.0 m) and 2 temperatures: FSE-N: -25 +80 C FSE-L: -50 +80 C b) for use with an Electronic Controller with 0 10V signal output (EC3-75x, EC3-92x or other): 3 lenghts (1.5-3.0-6.0 m) and 1 temperature: FSP-L: -50 +80 C Selection Chart Power Modules FSP Type Part No. Supply Voltage Current Range (A) Electronic Controller Max. Start Current, max 1 sec (A) Power Supply Cable Length (mtr) Motor Cable Length (mtr) Wire Diameter FSP-150 800 370 0,3-5 15 A 1 050 FSP-180 800 373 230V / 50Hz 0,3-8 24 A 1,5 0,75 3 x 1 mm 2 1 050 FSP-340 800 376 400V / 3 / 50Hz 0,3-4 12 A 5 x 1 mm 2 1 650 Selection Chart Control Modules FSE Type Part No. Refrigerants Adjustment Range P Cut (bar)* Cut-off Pressure factory set (bar) Test Pressure Pressure Connection Weight (g) FSE-01S 804 701 R134a 4 12.5 7.8 30 bar 7/16-20 UNF female 125 FSE-02S 804 706 R 22, R 407C, 10 21 15.5 36 bar 7/16-20 UNF female 125 R 404A, R 507 FSE-03S 804 711 R410A 12 28 20.4 48 bar 7/16-20 UNF female 150 * P Cut = Cut-off pressure at which fan is switched off / lower end of proportional range; see control diagram on page 2 Selection Chart Cable Assemblies for connection to FSE Control Module Temperature Range -25 to 80 C / no UL Temperature Range -50 to 80 C / UL appr. Type Part No. Type Part No. Length (mtr.) Weight (g) FSE-N15 804 680 FSE-L15 804 683 1,5 80 FSE-N30 804 681 FSE-L30 804 684 3,0 130 FSE-N60 804 682 FSE-L60 804 685 6,0 220 for connection to EC2, EC3 and other controllers FSP-L15 804 693 1,5 FSP-L30 804 694 3,0 FSP-L60 804 695 6,0 Weight (g) FSPE_35050_EN_R06.doc 3 / 8 25.07.2007

Accessories FSP-K00 Part No. 800 379 If DIN rail mounting of FSP Power Module is required DIN Rail Mounting Kit FSP-K00 can be used. Order instructions For use with EC2-5xx, EC3-75x, EC3-92x and other Controllers Power Module FSP and cable assembly FSP-Lxx should be used: Example: FSP-180 Part No. 800 373 + cable assembly FSP-L15 Part No. 804 693 For use with FSE-0xx Control Modules always select Control Module FSE-0xx, Power Module FSP-xxx Cable Assembly FSE-Nxx for standard temperature or FSE-Lxx for low temperature range and UL approval. The table below shows typical examples for refrigeration or air-conditioning applications. FSE-N15 FSP-L15 FSE-02S Selection Chart for Standard Product Sets with FSE Control Modules Maximum Motor Rating Single-phase 230VAC 5 Amps Single-phase 230VAC 8 Amps 3-phase 400V/3/50 4 Amps Refrigerant Type Part No. Type Part No. Type Part No. FSE-01S 804 701 FSE-01S 804 701 FSE-01S 804 701 R 134 a FSP-150 800 370 FSP-180 800 373 FSP-340 800 376 FSE-N15 804 680 FSE-N15 804 680 FSE-N15 804 680 FSE-02S 804 706 FSE-02S 804 706 FSE-02S 804 706 R 22 / R 407C / R 507 FSP-150 800 370 FSP-180 800 373 FSP-340 800 376 FSE-N15 804 680 FSE-N15 804 680 FSE-N15 804 680 FSE-03S 804 711 FSE-03S 804 711 FSE-03S 804 711 R 410 A FSP-150 800 370 FSP-180 800 373 FSP-340 800 376 FSE-N15 804 680 FSE-N15 804 680 FSE-N15 804 680 FSPE_35050_EN_R06.doc 4 / 8 25.07.2007

Name Scheme FSP Power Modules F S P - 1 5 0 Series Power Supply 1 = 230V 1-phase/50Hz 3 = 400V 3-phase/50Hz Cable Length Power Supply 0 = 1,5 mtr. 9 = Customer specific Length Max. Current 4 = 4 Amps 5 = 5 Amps 8 = 8 Amps Name Scheme FSE Control Modules F S E - 0 1 S Series 0 = Standard Series C = Customer specific Type Adjustment range* 1 = 4 12.5 bar (factory setting 7.8 bar) 2 = 10... 21 bar (factory setting 15.5 bar) 3 = 12 28 bar (factory setting 20.4 bar) * Cut-off pressure at which fan is switched off / lower end of proportional range Pressure Connectors S = 7/16-20 UNF female with schrader opener A = 7/16-20 UNF male K = 7/16-20 UNF flare nut with 1 mtr. capillary tube and schrader valve opener U = 6 mm ODF X = 1/4 ODF Name Scheme Cable Assemblies F S E - N 1 5 Cable for fan speed control E = connection FSE with FSP P = connection FSP with other controller Temperature range* N = -25 +80 C L = -50 +80 C Cable length 15 = 1.5 m 30 = 3.0 m 60 = 6.0 m FSPE_35050_EN_R06.doc 5 / 8 25.07.2007

Technical Data FSP Temperature range Signal Input Voltage 0 10 VDC Storage and -40 C 70 C Supply Voltage see selection chart transportation Operation -20 C 65 C Material housing Aluminum with plastic ends, completely molded with a 2 component Polyurethane casting compound. Resistant against common refrigerant oils. EMC Compatibility EN 55014-1:2000 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 50082-1 Mounting Direct with screws or DIN-rail with mounting clips (see accessories) Protection class (IEC529/EN 60529) IP 67 Dimensions (mm) FSP-150 / FSP-180 FSP-340 10 750 10 750 M 230VAC 5A max Ø 5 M 400V 3 Ph / 4A max 70 128 18 Signal 0... 10V FSP-150 PCN: 800 370 Emerson Electric GmbH & Co OHG 71332 Waiblingen / Germany Made in Switzerland 230VAC Ø 3 18 50 70 205 18 FSP-340 PCN: 800 376 Emerson Electric GmbH & Co OHG 71332 Waiblingen / Germany Made in Switzerland Ø 5 Ø 3 18 50 1500 110 Signal 0... 10V 400V 3 Ph / 50Hz 1500 60 110 60 47 47 3 3 15 15 120 15 15 120 FSPE_35050_EN_R06.doc 6 / 8 25.07.2007

Technical Data FSE Supply Voltage 10V; supplied by FSP Power Module Materials Housing cover Operating current Pressure connection 0 10 VDC output max. 1 ma FSE-01S and FSE-02S FSE-03S Medium compatibility HFC, HCFC, POE-, synthetic and Temperature Range mineral oils Operation Protection class (IEC529/EN 60529) PA Brass Stainless Steel -20 +65 C IP 65 Dimensions (mm) FSE-01S / FSE-02S FSE-03S 51 28 FSE-N15 15 54 70 54 99 55 55 36 48 20 39 43 20 48 39 FSPE_35050_EN_R06.doc 7 / 8 25.07.2007

ALCO CONTROLS is not to be held responsible for erroneous literature regarding capacities, dimensions, applications, etc. stated herein. Products, specifications and data in this literature are subject to change without notice. The information given herein is based on technical data and tests which ALCO CONTROLS believes to be reliable and which are in compliance with technical knowledge of today. It is intended only for use by persons having the appropriate technical knowledge and skills, at their own discretion and risk. Since conditions of use are outside of ALCO'S control we can not assume any liability for results obtained or damages occurred due to improper application. This document replaces all earlier versions. Emerson Electric GmbH & Co. OHG ALCO CONTROLS Heerstraße 111 D-71332 Waiblingen Germany Phone...49-(0)7151-509-0 Fax...49-(0)7151-509-200 www.ecopeland.com/alcoliterature.cfm Benelux Denmark & Finland Eastern Europe, Turkey & Iran France, Greece, Maghreb Deutschland, Österreich, Schweiz Italia Middle East & Africa Poland Russia & Cis España & Portugal Sweden & Norway UK & Ireland Phone.: +31 (0)773 240 234 +32 (0)87 305 565 +32 (0)87 305 061 +33 (0)478 668 570 +49 (0)6109 6059 0 +39 02 961 78 1 +97 148 832 828 +48 (0)22 458 9205 +7 495 981 9811 +34 93 4 123 752 +32 (0)87 305 565 +44 (0)1 189 838 000 Fax: +31 (0)773 240 235 +49 24 08 929 568 +32 (0)87 305 506 +33 (0)478 668 571 +49 (0)6109 6059 40 +39 02 961 78 888 +97 148 832 848 +48 (0)22 458 9255 +7 495 981 9816 +34 93 4 124 215 +49 24 08 929 568 +44 (0)1 189 838 001 FSPE_35050_EN_R06.doc 8 / 8 25.07.2007