Types P551 and P551A External Closing Spring Retrofit Kits for the Type N550/N551 ESV

Similar documents
Type N550 Snappy Joe Emergency Shutoff Valves

Type N550 Emergency Shutoff Valves. Instruction Manual. Type N550 Emergency Shutoff Valves. Introduction. Specifications. Scope of Manual.

Types C401, C402, C407, C421, C427, C403, and C831 Jet Bleed Internal Valve Retrofit Kits

type 122a three-way Switching Valve

289 Series Relief Valves

WARNING. Mounting Instructions D103996X012 May DVC6200/DVC2000 Digital Valve Controller on Linear Actuator

Y690A Series Pressure Reducing Regulators

Type 289RC Exhaust Booster

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Y690A Series Pressure Reducing Regulators

type 630r relief Valve

OBSOLETE DOCUMENT. 167D Series Switching Valves. Bulletin 71.7:167D. Introduction. Features

WARNING. Mounting Instructions D103998X012 June DVC6200/DVC2000 Digital Valve Controller Linear Actuator Side Mount

Y610A, Y611A, and Y612A Series Vacuum Service Equipment and Relief Valves

167D Series Switching Valves

T205VB Series Tank Blanketing Vacuum Breakers

Type 310A-32A Pressure Reducing Regulator

Type 644 and 645 Differential Pressure Pump Governors

Type D2 FloPro Control Valve

M Series Manual Handwheel Gear Actuator

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

Errata Sheet. for. SS-260 Valve

Type 289P Pilot-Operated Relief Valve

Baumann Mikroseal Control Valve

Bettis M11 Manual Hydraulic Override System Operating Instructions for HD, T, and G Series Pneumatic and Hydraulic Actuators

67C Series Instrument Supply Regulators

M Series Manual Handwheel Gear Actuator

161 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Type MR108 Direct-Operated Backpressure Regulators

119 Series Fuel Gas Valve

Baumann Pneumatic Pressure Controller (for Industrial and Sanitary Applications)

Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions

Fisher VBL Volume Booster

Fisher 1077 Manual Handwheel Rotary Actuator

Fisher 2052 Diaphragm Rotary Actuator

Fisher 644 and 645 Differential Pressure Pump Governors

OBSOLETE DOCUMENT. PRX Series Pilots for Pilot-Operated Pressure Reducing Regulators. PRX Series. Introduction. Product Description

Fisher A31A Cryogenic High Performance Butterfly Valve

Fisher CCV-N Fuel Gas Control Valve

ES-660 Series Spring-Loaded Hatch

Baumann Sanitary Angle Control Valve

Design D4 Control Valve

Type 63EG-98HM Pilot-Operated Relief Valve or Backpressure Regulator

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

ES-665 Series Spring-Loaded Thief Hatch

Fisher TBX Hydro Plug Fixture

Type 289P Pilot-Operated Relief Valve

Type 8560 Eccentric Disk Butterfly Control Valve

Fisher FIELDVUE DVC6000 Digital Valve Controller Dimensions

Fisher POSI-SEAL A31A Cryogenic High Performance Butterfly Valve

Fisher FIELDVUE DVC6200 Digital Valve Controller / Magnet Assembly Dimensions

Baumann Series Flexsleev Control Valve Instructions

Baumann Sanitary Diaphragm Angle and Inline Control Valve

Fisher D2T FloPro Control Valve

Fisher 3024C Diaphragm Actuator

GUIDE OF CHANGE MANAGEMENT. Replacement of Fisher POSI-SEAL A81 High-Performance Butterfly Valve with Fisher 8580 High-Performance Butterfly Valve

Fisher V250 Rotary Control Valve

Fisher 8590 High-Performance Butterfly Valve

Baumann Sanitary Control Valve

Fisher 1B and 1BR Constant Pressure Pump Governor Actuators

Features. Product Bulletin 51.6:8590 August Valve D104017X012

Design D and DA Control Valves

ME217PIB / ME503PIB SMART INTERLOCK TECHNOLOGY ACME ADAPTER INTERLOCK BRACKET INSTALLATION AND OPERATING INSTRUCTIONS

Fisher 9500 Butterfly Control Valve

Fisher EZ-Overtravel (EZ-OVT) Valve Trim

Fisher SS-263 Volume Booster

Fisher Z500 Severe Service Ball Valves

Fisher CL600 Control-Disk Valve

Type T205B Balanced Tank Blanketing Regulator

WARNING. Mounting Instructions D103778X012 June 2013

Baumann Way Control Valve

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Bolt Torque Information Supplement to Fisher 249 Sensor Instruction Manuals

Fisher RSS Lined Globe Valve

Fisher D4 Control Valve Assembly

Fisher CVX Hydro Plug Fixture

Fisher RSS Lined Globe Valve

HIGH PRESSURE CONTROL VALVE R2L ACTUATOR

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Connectors for Diagnostic Testing with the FlowScanner Valve Diagnostic System

SLAM-SHUT VALVE. Type OSE

PRESSURE/TEMPERATURE RATINGS ASME B16.34 VALVES

Fisher 685 Piston Actuator

Fisher ENVIRO SEAL Packing System for Rotary Valves

FLA Series Pressure Reducing Regulator

Fisher D and DA Control Valves

Design V250 Rotary Control Valve

167D Series Switching Valves

Fisher V260 Ball Control Valve

Fisher A31D Double-Flange High-Performance Butterfly Valve

Fisher VBL Volume Booster

Fisher A31D Double-Flange High-Performance Butterfly Valve

Fisher WhisperFlo Aerodynamic Noise Attenuation Trim

Fisher Whisper Trim III Cages

Model ES-660-HF High Flow Spring-Loaded Hatch

Fisherr V150S Slurry Vee-Ball Control Valve NPS 3 through 12

Baumann Sanitary Angle Control Valve

Bulletin: Floating Ball Valve. Tartarini Floating Ball Valve. Introduction. Features and Benefits

Fisher 656 Diaphragm Actuator

Baumann Series Sanitary Regulators

Transcription:

Instruction Manual MCK-1189 Types P551 and P551A October 2015 Types P551 and P551A External Closing Spring Retrofit Kits for the Type N550/N551 ESV! WARNING Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion and/or fire causing property damage and personal injury or death. Fisher equipment must be installed, operated and maintained in accordance with federal, state and local codes and Fisher instructions. The installation in most states must also comply with NFPA No. 58 or ANSI K61.1 standards. Only personnel trained in the proper procedures, codes, standards and regulations of the applicable industries should install and service this equipment. Possible hand and finger pinch points between closing Type N550/N551 handle and latch block. Adding a Retrofit Kit causes the handle to close quickly and with extreme force. Keep hands and fingers away from handle as it closes. Introduction Scope of the Manual This Instruction Manual covers installation of the Types P551 and P551A External Closing Spring Retrofit for the Type N550/N551 Emergency Shutoff Valve (ESV). Figure 1. Type P551 Parts Kit See pages 2-4 for installation steps. Description The P551 KIT, FIGURE 1, is designed to aid the closure of the Type N550/N551 ESV. The Type P551A KIT, FIGURE 2, is designed to aid the closure of the Type N550/N551 equipped with a Type P327A Remote Pneumatic Release Air Cylinder. Figure 2. Type P551A Parts Kit See pages 5-7 for installation steps. D450094T012 www.fisherregulators.com

Note If the Retrofit Kit installation is the only repair then it is not necessary to close off an upstream valve and remove pressure from both the inlet and outlet of the Type N550/N551 Emergency Shutoff Valve (ESV). If additional repairs are to be made on the Type N550/N551, then the valve must be isolated and all pressure removed before making those repairs. The Type N550/N551 valve handle must be in the closed position (handle parallel to pipe) before removing the cap screw. TYPE P551 INSTALLATION INSTRUCTIONS HOW TO INSTALL A TYPE P551 RETROFIT KIT ON A TYPE N550/N551 MANUAL ACTUATOR WITH REMOTE CABLE RELEASE. Step 1 Close the Type N550/N551 valve. Step 2 Disconnect remote cable. Step 3 Remove handle bolt and handle. Save these two parts. Step 4 Discard the fuse link. 2

Step 5 Remove latch bolt(s). Older valves will have 2 bolts. Discard the bolt(s) and latch block. Step 6 Use a 5/32 Allen head wrench to screw 1/4 in. / 6.35 mm long bolt into bottom hole. Step 7 Tighten until bolt head seats firmly on body. Step 8 Place latch block on body with lower blind hole over bolt in body. Step 9 Install 3/4 in. / 19.1 mm long bolt through second hole and firmly tighten with 5/32 Allen head wrench. Step 10 Place square end of new fuse link into handle. 3

Step 11 Place handle and fuse link over valve shaft. HANDLE MUST POINT TOWARDS LATCH BLOCK, NOT UP. Step 12 Install spring mandrel and torque spring so that the square end of the spring mandrel fits in the square hole in the fuse link. Step 13 IMPORTANT: The side hole holding the short spring end MUST BE POINTED DOWN. Step 14 Reinstall handle bolt and firmly tighten. Step 15 Fasten long end of spring under latch block by ROTATING 180 DEGREES CLOCKWISE. Step 16 Reattach and adjust remote release cable for correct operation. 4

Possible hand and finger pinch point between closing Type N550/N551 handle and latch block. Handle closes quickly and with extreme force. Keep hands and fingers away from handle as it closes. Note If the Retrofit Kit installation is the only repair then it is not necessary to close off an upstream valve and remove pressure from both the inlet and outlet of the Type N550/N551 Emergency Shutoff Valve (ESV). If additional repairs are to be made on the Type N550/N551, then the valve must be isolated and all pressure removed before making those repairs. The Type N550/N551 valve handle must be in the closed position (handle parallel to pipe) before removing the cap screw. Step 17 Rotate handle counter clockwise to open valve. Valve must stay open. HANDLE AND VALVE MUST QUICKLY SNAP CLOSED when (a) the remote release cable is pulled and (b) the handle is pushed closed from the open position. TYPE P551A INSTALLATION INSTRUCTIONS HOW TO INSTALL A TYPE P551A KIT ON A TYPE N550/N551 WITH REMOTE PNEUMATIC RELEASE TYPE P327A. Step 1 Close the Type N550/N551 valve. Step 2 Turn off and disconnect the air source from the Type P327A cylinder. 5

Step 3 Remove handle bolt and handle. Save these two parts. Step 4 Discard the fuse link. Step 5 Remove latch bolt(s). Older valves will have 2 bolts. Discard the bolt(s) and latch block. Step 6 Use a 5/32 Allen head wrench to screw 1/4 in. / 6.35 mm long bolt into bottom hole. Step 7 Tighten until bolt head seats firmly on body. Step 8 Place latch block on body with lower blind hole over bolt in body. 6

Step 9 Install 3/4 in. / 19.1 mm long bolt through second hole and firmly tighten with 5/32 Allen head wrench. Step 10 Place square end of new fuse link into handle. Step 11 Place handle and fuse link over valve shaft. HANDLE MUST POINT TOWARDS LATCH BLOCK, NOT UP. Step 12 Install spring mandrel and torque spring so that the square end of the spring mandrel fits in the square hole in the fuse link. Step 13 IMPORTANT: The side hole holding the short spring end MUST BE POINTED DOWN. Step 14 Reinstall handle bolt and firmly tighten. 7

Step 15 Fasten long end of spring under latch block by ROTATING 180 DEGREES CLOCKWISE. Step 16 Reattach the remote air source. There should be a MINIMUM OF 30 psi / 2.07 bar to the cylinder. Possible hand and finger pinch point between closing Type N550/N551 handle and latch block. Handle closes quickly and with extreme force. Keep hands and fingers away from handle as it closes. LPG Equipment Emerson Process Management Regulator Technologies, Inc. USA - Headquarters McKinney, Texas 75070 USA Tel: +1 800 558 5853 Outside U.S. +1 972 548 3574 Step 17 Rotate handle counter clockwise to open valve. Valve must stay open. HANDLE AND VALVE MUST QUICKLY SNAP CLOSED when (a) air pressure is exhausted from Type P327A remote release and (b) the handle is pushed closed from the open position. For further information visit www.fisherregulators.com The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls International LLC, a business of Emerson Process Management. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Process Management Regulator Technologies, Inc. does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Process Management Regulator Technologies, Inc. product remains solely with the purchaser. Emerson Process Management Regulator Technologies, Inc., 2002, 2015; All Rights Reserved