XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

Similar documents
IMMERSION FIRED HOT WATER BOILER

Power Flame Incorporated

S1 SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET

PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

M SERIES TECHNICAL DATA INFORMATION PACKET

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

Electric Resistance Boilers Steam or Hot Water

Model CBEX Elite HP

Replacement Parts List. Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & _ _Rev B

Universal is a family of commercial gas water heaters that are designed to fit into tight retrofit applications

Design and Application Details

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

Model CBLE Boilers HP

XIII. Repair Parts 106

PROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET

Power Direct Vent PDV T Model

Hamilton 3VO Submittal

CIRCULATION HEATERS SPECIFICATIONS DESCRIPTION FEATURES CH & CHP SERIES HEAT EXCHANGE AND TRANSFER, INC. 6 to 480 kw and higher. Flanged construction

Replacement parts. Table 6. Item Description Part no. A Regular front section

Date: Project #: Engineer: Prepared By: Bid Date:

D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR

Crest Heating Boilers FBN(L)

BOILER RATINGS. Net Ratings Oil Gas

Specifications of STICKTITE and PILOTPAK Nozzles

CBLE HP. Boiler Book 05/2017

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

TECHNICAL SERVICE BULLETIN

PROFIRE. 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements.

420-19,100 MBH GPH MODEL ACO/ACGO GAS AIR OR STEAM LIGHT OIL ATOMIZING FORCED DRAFT BURNERS

RAYPAK REPLACEMENT PARTS

LANDFILL GAS ELEVATED (CANDLESTICK) FLARE SYSTEM

PROFIRE TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications.

Specifications of STICKTITE and PILOTPAK Nozzles

TECHNICAL INSTRUCTIONS

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting

CGa - Series 1 & 2 Section Assembly Parts

Features Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design

Model 4WI HP 4 Pass Wet-Back with Integral Burner

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve

PREMIX TUNNEL BURNERS

A.O. SMITH WATER PRODUCTS CO., INC W. 115TH STREET ALSIP, ILLINOIS Phone: Fax: Website:

AF90. AF90 Gas Furnace High Efficiency. Features

97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel

2.0 Burner Operating Parameters and Requirements

Figure 1-1(d) Tft Installation Kit

COMBUSTION. Model HDR - RF. Manual Addendum. (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners

Low Temperature Burners - STICKTITE and PILOTPAK Nozzles

Models. Save This Manual For Future Reference. International Comfort Products Corporation (USA) Lewisburg, TN USA LP1 5/16/

Ultra High Efficiency Models With Direct Spark Ignition

Power Flame Incorporated

COMMERCIAL MODELS: XTHERM 1005A THROUGH 2005A

Eclipse Vortometric Burners Series HI

ULTRA LOW NOx ATMOSPHERIC VENT WATER HEATER

RAYPAK ILLUSTRATED PARTS LIST

ULTRA HIGH EFFICIENCY MODELS WITH DIRECT SPARK IGNITION

Crest Heating Boilers FBN(L)

Direct Gas-Fired Heating

Biogas safety control equipment

SAMPLE SPECIFICATIONS

Heater Parts. LXi Low NOx. See Detail on next page Zodiac Pool Systems, Inc. Product Catalog. Heater Parts. After. July Before.

SECTION H3 TRAYMASTER SERIES DEAERATORS

G23 Bulletin # September 1998 Supersedes June 1995

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev D

ACL HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING

A.O. Smith Water Heater Parts Fulfillment 125 Southeast Parkway, Franklin, TN

TGIF-3. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

Design and Application Details

PRESSURIZED STEEL BOILER WITH REVERSED FLAME

TROUBLESHOOTING. 1. What is the model and serial number? If you don t know, how old is it? Give description.

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

SECTION H4 BOILERMATE DEAERATORS

(For serial numbers before w/ analog control)

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

RESIDENTIAL BOILER 95% HIGH EFFICIENCY COMMERCIAL BOILER 93% HIGH EFFICIENCY

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

15B SERIES II. Models 15B045FE 15B070FE 15B096FE 15B120FE 15B145FE 15B170FE 15B195FE 15B245FE 15B295FE

RAYPAK ILLUSTRATED PARTS LIST

HEG HIGH VOLUME SERIES HOT WATER PRESSURE WASHERS

Model HDS and HDSX Burner

HF60. Service Parts Part number list on following page. Hydroflex 60 Central Heat Last Serial # /17

RAYPAK ILLUSTRATED PARTS LIST

Packaged Gas Burner. Low CO and NOx emissions. Direct spark ignition. Factory pre-set for ease of start-up and operation

Series CC Condensate Units

XP80 / XV80 Highboy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA

RAYPAK ILLUSTRATED PARTS LIST

GAS. PFG Section & Base Assembly

SECTION LOW-PRESSURE STEAM BOILERS SPEC WRITER NOTES:

VENTING & COMBUSTION AIR GUIDE

COVER EQUIPMENT. VAREC BIOGAS 400W Series EMERGENCY RELIEF MANHOLE COVERS

Manual C888 Rev.709 Copyright Power Flame Incorporated 2004 Printed U.S.A.

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

WAC Air Curtains Technical Guide

Replacement Parts List. Armor Condensing Water Heater. AW 151 thru 801. AWII-RP_ _ _Rev V

ETP-5G & ETP-10G ECO-TECH PLUS GAS CONVECTION STEAMER PARTS AND SERVICE MANUAL

Transcription:

IMMERSION FIRED HOT WATER BOILER April 1, 2003 GENERAL DESCRIPTION The Sellers immersion fired hot water boiler is a horizontal, single pass, firetube boiler designed to burn natural gas. The unique burner assembly delivers premixed air and gas through multiple nozzles. The air-gas mixture is ignited as it exits each flame retaining nozzle at high velocity. The resulting flames are long and small in diameter. The flame from each of these nozzles is directed into a 2 O.D. tube that is completely immersed in liquid. There is a separate tube for each flame with the same amount of heat going into each tube. These small diameter flames burn in the first half of the tube lengths. Therefore, the fire shines on half of the heating surface in the single pass boiler 50% of the total heating surface is radiant heating surface. The high percentage of radiant heating surface, the low heat input into each tube, and the even distribution of heat throughout the multiple tubes virtually eliminate thermal stress problems that are common in multiple pass boilers. XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE Twenty Year Non Pro-rated Thermal Shock Warranty Lower Emissions. Less Than 50 PPM NOx Standard (30 PPM NOx Available) High Efficiency Performance (See Chart Below) Lower Maintenance Costs Single Source Burner - Boiler Package Absolutely No Refractory Five Year Non Pro-rated Burner Warranty U.L. Labeled Packaged Boiler BOILER NET STACK TEMPERATURE AND EFFICIENCY RATING OPERATING TEMPERATURE 180 F 200 F 220 F 240 F 10 200 231 (84.9%) 251 (84.4%) 270 (84.0%) 289 (83.5%) 250 800 211 (85.4%) 230 (84.9%) 249 (84.5%) 267 (84.0%) When unit is in proper adjustment. Stack temperature based on 70 degree ambient air temperature. Addition of 30 PPM NOx option will lower efficiencies slightly.

HOT WATER BOILER RATINGS, CAPACITIES, WEIGHTS SEA LEVEL TO 3000 FEET ALTITUDE BOILER HORSE POWER HOURLY GAS INPUT (1000BTU) GROSS HOURLY OUTPUT (1) WATER CAPACITY (U.S. GAL) WATER CAPACITY (POUNDS) SHIPPING WEIGHT (POUNDS) 100 PSI 150 PSI 10 418 335 156 1,299 2,370 2,420 15 628 502 153 1,273 2,440 2,470 20 837 670 150 1,255 2,490 2,530 30 1,255 1,004 145 1,208 2,590 2,590 40 1,674 1,339 139 1,161 2,680 2,680 50 2,092 1,674 224 1,872 3,260 3,260 60 2,511 2,009 219 1,826 3,360 3,360 70 2,929 2,343 213 1,779 3,450 3,450 80 3,348 2,678 319 2,659 4,250 4,330 100 4,184 3,348 307 2,565 4,470 4,470 125 5,231 4,184 424 3,539 5,590 5,860 150 6,277 5,021 411 3,427 5,820 6,090 175 7,323 5,858 397 3,314 6,050 6,320 200 8,369 6,695 534 4,456 7,450 7,580 250 10,461 8,369 654 5,460 9,520 9,520 300 12,553 10,043 839 7,000 11,520 12,110 350 14,645 11,716 806 6,728 12,060 12,490 400 16,738 13,390 1,015 8,471 12,840 13,780 500 20,922 16,738 1,218 10,162 15,080 15,600 600 25,107 20,085 1,446 12,067 17,390 18,520 700 29,291 23,433 1,698 14,168 19,920 21,310 800 33,475 26,780 1,981 16,535 23,330 24,190 GAS REQUIREMENTS Main and pilot gas pressure regulators are supplied with each boiler. Refer to the chart below for gas pressure requirements. Pressures shown are with the unit running. For pressure above 10 PSI, install a second regulator to reduce the pressure to the standard range ELECTRICAL REQUIREMENTS A single incoming power connection is required to the junction box provided at the hinge of all boilers. Boilers are pre-wired (105 C color coded wire) to numbered terminal strips. Panels include a control transformer to provide 5 Amp., 120 Volt service. Boilers are wired for jobsite supply power characteristics. Boiler Horsepower Pressure required at gas train inlet Min. (3) Std Range Max. 10-20 7 8 to 1 PSI 10 PSI 30-80 8 12 to 1 PSI 10 PSI 100-150 10 16 to 1 PSI 10 PSI 175-200 14 20 to 1 PSI 10 PSI 250 14 2 to 10 PSI 10 PSI 300-350 14 1.5 TO 10 PSI 10 PSI 400-800 1 PSI 2 TO 10 PSI 10 PSI STACK REQUIREMENTS Design stack to provide.02 to.04 water column draft at flue outlet. Smooth transitions and bends are required. Maximum stack weight on boiler should be 1000 pounds on 10 to 80 HP and 2000 pounds for 100 to 800 HP units. AIR REQUIREMENTS Provide 1/2 square foot of free air inlet area per 1,000,000 BTU input to the burner. Cross ventilation is preferred in lieu of a single opening. (3) Special gas trains required at additional cost. For low NOx application with low gas pressure, consult the factory.

HOT WATER BOILER DIMENSIONS C-100- C-10-W C-15-W C-20-W C-30-W C-40-W C-50-W C-60-W C-70-WC-80-W W OVERALL DIMENSIONS: LENGTH A 141 141 141 141 143 143 145 150 151 159 WIDTH B 36 36 36 36 36 42 42 42 48 48 BURNER WIDTH C 30 30 30 32 32 35 35 35 41 41 BURNER HEIGHT D 56 56 56 56 59 65 65 65 70 70 SECONDARY AIR CAP HEIGHT DD 6 6 6 6 6 6 6 6 6 6 BASE: WIDTH E 24 24 24 24 24 24 24 24 30 30 LOCATION F 20 20 20 20 20 20 20 20 20 26 LENGTH FF 60 60 60 60 60 60 60 60 60 60 SHELL: LENGTH H 108 108 108 108 108 108 108 108 108 114 DIAMETER INSIDE J 24 24 24 24 24 30 30 30 36 36 SHELL CONNECTIONS: DRAIN SIZE K 1 1 1 1 1.25 1.25 1.25 1.25 1.5 1.5 DRAIN LOCATION KK 16 16 16 16 16 16 16 16 16 22 MANUAL FILL SIZE L 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 MANUAL FILL LOCATION LL 23 23 23 23 23 23 23 23 23 23 HOT WATER OUTLET SIZE (NOTE 3) M 2 2 2.5 3 3 4f 4f 4f 4f 4f HOT WATER OUTLET LOCATION MM 26 26 26 26 26 26 26 26 26 33 HOT WATER RETURN SIZE (NOTE 3) N 2 2 2.5 3 3 4f 4f 4f 4f 4f HOT WATER RETURN LOCATION NN 64 64 64 64 64 64 64 64 64 71 GAS CONNECTIONS: MAIN BURNER VALVE IPS (NOTE 5) QQ 1.25 1.25 1.5 1.5 1.5 1.5 2 2 2 2.5 VERTICAL LOCATION (NOTE 11) Q 33 33 33 33 33 36 36 36 39 39 HORIZONTAL LOCATION (NOTE 4) R 20 20 20 20 20 20 22 26 26 28 PILOT BURNER VALVE IPS S 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 FLUE CONNECTIONS: FLUE SIZE (NOTES 6 & 10) O 6 6 8 8 10 10 10 12 12 14 FLUE LOCATION T 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 4.75 FLUE HEIGHT TT 43 43 43 43 43 49 49 49 55 55 INSTALLATION CLEARANCES: COMBUSTION ASSEMBLY SWING U 35 35 35 36 36 38 40 41 46 48 RELIEF DOOR SWING (NOTE 7) V 18 18 18 18 18 21.5 21.5 21.5 25.5 25.5 TUBE REMOVAL, FRONT (NOTE 8) XX 73 73 73 73 73 73 73 73 73 66 TUBE REMOVAL, REAR (NOTE 8) X 71 71 71 71 71 71 71 71 71 72 RELIEF DOOR ASSEMBLY VV 10 10 10 10 10 11 11 11 12 12 FLUE OUTLET PROJECTION Y 2.25 BLOWER : 1 1.5 1.5 2 2 3 5 5 5 7.5 See Notes on Last Page. S-125- W 160 54 47 75 36 26 60 114 42 1.5 22 1.5 23 6f 33 6f 71 2.5 42 28 0.75 14 4.75 61 53 29.5 66 72 13 2.25 7.5

HOT WATER BOILER DIMENSIONS S-150-W S-175-W S-200-W S-250-W S-300-W S-350-W S-400-W S-500-W S-600-W S-700-W S-800-W OVERALL DIMENSIONS: LENGTH A 166 166 167 193 196 210 213 214 218 220 228 WIDTH B 57 57 61 64 67 72 76 83 89 95 101 BURNER WIDTH C 53 53 56 62 62 72 74 82 88 94 100 BURNER HEIGHT D 73 73 82 80 87 97 102 107 112 120 125 SECONDARY AIR CAP HEIGHT DD BASE: WIDTH E 36 36 42 42 48 48 54 57 63 66 72 LOCATION F 26 26 26 3 3 3 3 3 3 3 3 LENGTH FF 60 60 60 104 104 104 104 104 104 104 104 SHELL: LENGTH H 114 114 114 140 140 140 140 140 140 140 140 DIAMETER INSIDE J 42 42 48 48 54 54 60 66 72 78 84 SHELL CONNECTIONS: DRAIN SIZE K 1.5 1.5 2 2 2 2 2 2 2 2 2 DRAIN LOCATION KK 22 22 22 34 34 34 34 34 34 34 34 MANUAL FILL SIZE L 2 2 2 2 2 2 2 2 2 2 2 MANUAL FILL LOCATION LL 23 23 23 28 28 28 28 28 28 28 28 HOT WATER OUTLET SIZE (NOTE 3) M 6f 6f 6f 8f 8f 8f 8f 10f 10f 10f 12f HOT WATER OUTLET LOCATION MM 33 33 33 36 36 36 36 36 36 36 36 HOT WATER RETURN SIZE (NOTE 3) N 6f 6f 6f 8f 8f 8f 8f 10f 10f 10f 12f HOT WATER RETURN LOCATION NN 71 71 71 88 88 88 88 88 88 88 88 GAS CONNECTIONS: MAIN BURNER VALVE IPS (NOTE 5) QQ 3 3 3 2.5 2.5 2.5 3 3 3 3 3 VERTICAL LOCATION (NOTE 11) Q 38 38 41 44 48 48 48 48 48 48 48 HORIZONTAL LOCATION (NOTE 4) R 32 32 32 34 34 48 50 50 50 50 56 PILOT BURNER VALVE IPS S 0.75 0.75 0.75 0.75 1 1 1 1 1.25 1.25 1.25 FLUE CONNECTIONS: FLUE SIZE (NOTES 6 & 10) O 16 18 18 20 22 24 26 28 32 34 36 FLUE LOCATION T 3.75 2.75 2.75 5.75 4.5 3.5 2.5 1.5-0.5-1.5-2.5 FLUE HEIGHT TT 61 61 67 67 73 73 79 85 97 103 109 INSTALLATION CLEARANCES: COMBUSTION ASSEMBLY SWING U 58 58 62 65 68 80 84 90 95 100 108 RELIEF DOOR SWING (NOTE 7) V 29.5 29.5 35.5 35.5 40 40 43 46 50 48 50 TUBE REMOVAL, FRONT (NOTE 8) XX 66 66 66 88 88 88 88 88 88 88 88 TUBE REMOVAL, REAR (NOTE 8) X 72 72 72 90 90 90 90 90 90 90 90 RELIEF DOOR ASSEMBLY VV 13 13 14 14 15 15 16 17 18 17 18 FLUE OUTLET PROJECTION Y 4.25 6.25 6.25 4.25 8.5 10.5 12.5 14.5 18.5 20.5 22.5 BLOWER : 7.5 7.5 10 15 15 15 15 20 20 25 25 See Notes on Last Page.

NOTES 1. Dimensions are accurate for layout but are subject to change. Certified prints are available upon request. 2. Lifting lugs and insulation are not shown on drawing. The manhole, when furnished, is not shown. 3. Openings are threaded unless indicated: f = Class 150 ASA flange. F = Class 300 ASA flange. Threaded couplings project 2 or less. 4. Provide R + 12 clearance from the right side of burner box to the right side wall to open hinged burner. 5. Gas train may change with gas type and pressure. 6. Outside diameter and dimensions are shown. (see note 10) 7. Provide J + 7 clearance from the rear end of the shell to swing the hinged back plate on 300 HP and larger boilers. 8. Tubes may be removed from the front or rear. 9. Dip tube (2 min.) provided on hot water outlet. 10. Flue outlet dimension on 300 HP and larger boilers are inside diameter with angle iron flanged connection. 11. Horizontal gas train dimension will vary based on required gas train components and addition of Low NOx option. Gas train may extend beyond burner manifold dimension C. STANDARD EQUIPMENT FURNISHED Pressure Vessel: 100 or 150 PSI, ASME stamped with H cloverleaf. Manholes: Standard on 500 HP or larger boilers. Handholes: Five (5) furnished, 3-1/2 x 4-1/2. Lifting lugs: One or more provided on each boiler. Energy X-tractors:. High temperature stainless steel to provide high efficiency. Installed in each tube. Insulation: 2 fiberglass with double painted steel jacket with precast hardtop walkway. Relief Door: Gravity operated for rear access and safety. Burner Assembly: Hinged to shell including: Blower assembly with drip proof motor. Air gas mixer. Individual burner nozzles. Air proving switch. Ignition transformer, spark and flame rods. Gas control trains with dual main shutoff cocks, pilot and main gas pressure regulators, gas volume adjustment and other components as follows:. Operating Temperature Control: Controls temperature. High Limit Temperature Control: Manual reset limit control. UL Labeled: Packaged boiler. Low Water Cutoffs: MM150-M float type with manual reset. Pressure Gauge: 4-1/2 dial type mounted on pigtail. Temperature Gauge: 5 dial type. Base: Heavy duty structural steel skid. Relief Valve(s): ASME rated for full boiler nozzle output at design pressure rating. Flame observation ports: Two or more provided in combustion chamber to view burners. Control Panel: With motor starter, control transformer with primary and secondary fuses, flame safeguard control (Honeywell RM7840), six (6) indicating lights. Optional flame safeguard controls available are Honeywell RM7800 and Fireye E110. 10-40HP 50HP 60-100HP 125HP 150-250HP 300-800HP Solenoid gas valve 2 - - - - - Motorized gas valve - 1 1 2 2 2 Proof of closure switch - 1 1 1 1 1 Pilot solenoid valves 1 1 1 2 2 2 Gas pressure switches - - 2 2 2 2 Vent valve - - - - - 1