Nickel Cadmium Batteries. KPH Models

Similar documents
Nickel Cadmium Batteries. KPM Models

KPM type Intended for medium discharge currents from 0.5 to 2 C

NCPP. Nickel Cadmium Pocket Plate Batteries. Single Cell Catalogue

NCPP. Nickel Cadmium Pocket Plate Batteries. Single Cell Dimensional and Electrical Data

ISO 9001:2000. Zavod AIT Nickel-Cadmium cells and batteries

ZAVOD AIT Nickel-Cadmium Cells and Batteries

Single Cell Range including LCE P LBE P

ZAVOD AIT Nickel-Cadmium Cells and Batteries

Range. Alcad Single Cell Range. Powerful assurance for maximum operating reliability

POWERPLUS NICKEL CADMIUM BATTERIES SINTERED PLATE / POCKET PLATE 5AH to 1000AH / 20+ years long life

RELIABILITY Power Systems Ni-Cd Batteries Div. DS Ver.3.11/ Jan 2011 Page 1/20

Ni-Cd Batteries. Solutions for the toughest requirements

NCPP. Nickel Cadmium Pocket Plate Batteries. Block Cell Dimensional and Electrical Data

VentPro Reduced Maintenance Nickel Cadmium Batteries for Stationary Applications

Why Ni-Cd batteries are superior to VRLA batteries. Statements and facts

MHR VRLA batteries are manufactured in compliance with TL, NEBS, GR, SR, IEC, BS, UL, ISO, OSHAS and CE quality and performance standards.

PIBAS Ni-Cd cells can be assembled into many different configuration forms, for example:

FAT. FAT Battery Range FIAMM.COM

Care and Feeding of Rechargeable Batteries. Chris Capener March 1, 2012

Industrial Batteries Network Power Powerfit S500 High energy density for maximum security. Specifications

AlphaCell RE Batteries. Copyright 2010 The Alpha Group. All Rights Reserved.

SCL P - SCM Ni-Cd single cells Capacity: 10 Ah to 70 Ah

Switchgear Utility specific gravity nominal sulfuric acid. 10 years, full float service at 77 F (25 C)

Battery Storage Systems

Vented fibre structure Nickel Cadmium batteries for stationary systems

Vantage ultra-low maintenance batteries

POWER-plus. Ni-Cd XHP. Capacity: 10 Ah to 250 Ah

SPECIFICATIONS. Top Terminal Batteries. SECTION A Division of Exide Technologies

V R L A HI-PERFORMANCE BATTERIES

bosfa spiral lead acid battery

Vantage Ultra-low maintenance batteries

2 Volt AGM Range. Haze Battery Company Ltd

Industrial Batteries / Network Power. Sonnenschein A400 FT.»The dryfit range for modular performance adaption«

Central Battery Systems Loadstar AC/DC Systems

Nickel Cadmium Batteries BLOCK TYPE

Uptimax New Generation Ni-Cd battery. Maintenance-free solution for backup power applications

Li-ion Battery System

Uptimax New Generation Ni-Cd battery. Maintenance-free solution for backup power applications

PURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

SUBSTATION EQUIPMENT - Page 1 of 8

Uptimax New Generation Ni-Cd battery. Maintenance-free solution for backup power applications

ULTIMA Ni-Cd BATTERY: PEAK PERFORMANCE WITH ULTRA LOW MAINTENANCE

LDP MP. Ni-Cd single cells. LD P - M P ranges Capacity: 10 Ah to 70 Ah L2.4. Benefits

RANGE SUMMARY OPzS Optima

Features and Benefits

Low maintenance TAB OPzS vented stationary batteries

SPA AGM VRLA batteries

OPzV Batteries. Technical Data

Tubular Flooded (OPzS) Batteries

PERFORMANCE SPECIFICATIONS

PowerStor Standby Battery Systems

Modular Max Range BATTERY SOLUTIONS. NEBS qualified. Reliable capacities. EverExceed power your applications

SD / SDH. Applicable Standards. Applications and Key Benefits. FIAMM Manufacturing. - Technical Features

DataSafe HX Top Terminated Batteries 6 and 12 Volt HX

CELLYTE 12 PLF & 12PLT Range

PURE LEAD PLUS UPS APPLICATIONS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

6 & 12 Volt Monobloc. Haze Battery Company Ltd

THE FORGOTTEN BATTERY, LEAD ACID.

ENERGY STORAGE SOLUTIONS

Tubular Gel (OPzV) Batteries. Stationary & Renewable Energy Applications

Stationary Batteries OPzS Cells

Reliability. Safety. Efficiency.

Tubular Flooded (OPzS) Batteries

Valve Regulated Lead Acid (VRLA) Battery Series Designed for UPS Standby Power Applications FEATURES & BENEFITS

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

Battery Selection Guide

Stationary Battery Systems Test & Monitoring Equipment

Golf / Utility Vehicles

VRPP. Nickel Cadmium Valve regulated Pocket Plate Batteries. Dimensional and Electrical Data

TYPE TEST REPORT. OPzS CELLS AND BLOCK BATTERIES. According to IEC

Industrial Batteries / Network Power. Sonnenschein A400 FT.»The dryfit range for modular performance adaption«

Renewable Energy Storage Solutions

EV Traction Dry Cell Battery Technology

EV Traction Dry Cell Battery Technology

Industrial Batteries Standby Power Marathon L Reliable and safe energy in long-term storage. Specifications

OPzV Batteries for Stationary Applications

Energy Storage. Lithium Batteries

BAE SECURA Product Programme Stationary Batteries ENERGY FROM BATTERIES BAE

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

FNC Battery Systems for Rail Vehicles

Industrial Standby batteries. A wide offer of reliable, long-life solutions

SECTION A Division of Exide Technologies

RES OPzV Premium Quality Batteries. for Renewable Energy Storage

RES OPzV Premium Quality Batteries. for Renewable Energy Storage

Industrial Batteries Standby Power Classic Solar Powerful energy storage for photovoltaic systems. Specifications

Industrial Batteries / Network Power. Sonnenschein A400 FT.»The dryfit range for modular performance adaption«

XHP. Low maintenance high performance batteries

Industrial Batteries Marathon T AGM long-term power on modular basis. Specifications

Sealed Lead Acid Battery STANDBY APPLICATIONS. Premium Brand of Flying Power Group. Certified by

Single Cell Range Technical manual

Symptom Corrective Action. Wrong polarity of cell, block, row of battery. Interruption at connector. Interruption due to empty cell.

SECTION A Division of Exide Technologies

Haze Battery Company Ltd. Sealed Lead Acid 2 Volt Bloc. Gelled Electrolyte Range

SPECIFICATIONS OF Ni-Cd BATTERY BANK

Pure Lead-Tin Technology

ANNEXURE XI. (Ni Cd Battery Bank) TECHNICAL SPECIFICATIONS OF 125V STATION BATTERY BANK OF GTG I.

Golf / Utility Vehicles

LIBERTY SERIES 1000 VALVE REGULATED LEAD-CALCIUM BATTERY For standby applications Capacities from 25 to 600 Ampere-hours

6 & 12 Volt Monobloc GEL Range

Alpha Lomain Ni-Cd Pocket Plate Battery Technical Manual. Effective: July Alpha Technologies

Transcription:

KPH Models

Translucent Nickel Cadmium Pocket Plate Batteries Alpha Industrial Power s Translucent Nickel Cadmium Pocket Plate Type Batteries are designed and manufactured in three categories long, medium, and high to the highest standards to provide unparalleled reliability and performance. Alpha Industrial Power s Nickel Cadmium Batteries are typically deployed for process control, utilities, railway operation, and petrochemical. Maintenance intervals are greatly extended and well suited to provide effective power back up with the properly sized equipment at competitive pricing. According to the discharge rate: - KPL Type: To a discharge rate of 0.5 C5 (A);Optimum use for discharge periods of 5 or more hours - KPM Type: To a discharge rate of 0.5 to 3.5 C5 (A); Optimum use for discharge periods of 30 minutes to 3 hours - KPH Type: To a discharge rate of 3.5 to 7 C5 (A); Optimum use for discharge periods of 30 minutes or less Characteristics and Advantages - Designed for mobile and stationary applications, fitted in mobile crates or placed on racks - Robust construction with high energy density - Superior performance in harsh operating conditions ( -40 C to 50 C / -40 F to 122 F) - Minimum self discharge - Long life and high cycling capabilities - Recyclable, easy assembly, handling and minimal maintenance - Low internal resistance - Compliant with IEC 60623 Charging - Constant current charging - Charging at constant voltage in the range of 1.40 V to 1.60 V per cell - Charging according to current limiting - Boost charging Boost (accelerated) charging is applied before putting batteries into operation or after longer storage periods, as well as after long operation in difficult or deep discharge conditions. - Float charging After extended storage periods and/or for the purpose of sustaining charge conditions, the battery is continuously float charged at a voltage range of 1.40 to 1.42

Cell Type KPH Cell Dimension Terminals Cell Weight (kg / lb) Cell Designation C5(Ah) WxLxH (mm / in) No. M (mm) With Electrolyte Electrolyte KPH-20P 20 85x45x256 / 3.35x1.77x10.1 2 10 1.65 / 3.63 0.4 / 0.88 KPH-24P 24 85x45x256 / 3.35x1.77x10.1 2 10 1.75 / 3.85 0.35 / 0.77 KPH-30P 30 85x85x256 / 3.35x3.35x10.1 2 10 2.75 / 6.05 0.9 / 1.98 KPH-40P 40 85x85x256 / 3.35x3.35x10.1 2 10 2.95 / 6.49 0.8 / 1.76 KPH-60P 60 130x70x330 / 5.12x2.76x12.99 2 16 5.3 / 11.66 1.1 / 2.42 KPH-70P 70 130x70x330 / 5.12x2.76x12.99 2 16 5.1 / 11.22 1.0 / 2.2 KPH-80P 80 130x70x330 / 5.12x2.76x12.99 2 16 5.7 / 12.54 1.1 / 2.42 KPH-100P 100 135x110x320 / 5.31x4.33x12.60 2 20 7.5 / 16.5 2.2 / 4.84 KPH-120P 120 165x105x355 / 6.50x4.13x13.98 4 20 8.2 / 18.04 1.8 / 3.96 KPH-140P 140 196x86x403 / 7.72x3.35x15.87 2 20 10.7 / 23.54 3.0 / 6.6 KPH-155P 155 165x105x355 / 6.50x4.13x13.98 2 20 11.5 / 25.3 2.5 / 5.5 KPH-170P 170 196x110x403 / 7.72x4.33x15.87 4 20 14.0 / 30.8 3.5 / 7.7 KPH-190P 190 165x105x400 / 6.50x4.13x15.75 4 20 14.8 / 32.56 3.3 / 7.26 KPH-200P 200 196x110x403 / 7.72x4.33x15.87 4 20 14.8 / 32.56 3.0 / 6.6 KPH-250P 250 196x147x403 / 7.72x5.79x15.87 4 20 19.3 / 42.46 5.5 / 12.1 KPH-275P 275 196x147x403 / 7.72x5.79x15.87 4 20 19.6 / 43.12 5.3 / 11.66 KPH-300P 300 196x147x403 / 7.72x5.79x15.87 4 20 20.5 / 45.1 4.2 / 9.24 Marking: P Plastic casing Other cell capacities can be provided according to specific customer requirements. H W L

Discharge Performance KPH Current (Amps) to 1.00V/Cell @ 20 C (68 F) Current (Amps) to 0.85V/Cell @ 20 C (68 F) Current (Amps) to 0.65V/Cell @ 20 C (68 F) Discharge Time in Seconds 90 60 30 10 1 90 60 30 10 1 90 60 30 10 1 Cell Type C5 (Ah) Discharge Current (A) KPH-20P 20 103 112 119 130 146 149 161 174 188 209 213 232 257 270 310 KPH-24P 24 123 134 142 155 174 178 192 207 223 247 252 275 305 320 368 KPH-30P 30 153 168 178 194 217 221 238 257 277 307 282 307 341 358 411 KPH-40P 40 204 224 238 259 290 296 320 345 372 413 379 413 458 481 553 KPH-60P 60 295 324 344 375 420 428 462 499 538 597 609 664 737 774 890 KPH-70P 70 344 378 400 436 488 497 536 579 625 693 707 770 855 897 1031 KPH-80P 80 393 432 459 500 560 571 616 665 718 797 813 886 983 1032 1187 KPH-100P 100 473 520 552 601 673 686 741 800 684 959 978 1066 1183 1242 1428 KPH-120P 120 568 624 663 723 810 826 892 963 1040 1154 1177 1283 1424 1495 1719 KPH-140P 140 599 658 699 762 853 870 939 1014 1095 1215 1239 1350 1498 1572 1808 KPH-155P 155 677 744 790 861 964 983 1061 1145 1236 1372 1399 1524 1692 1776 2049 KPH-170P 170 742 816 866 944 1057 1078 1164 1257 1357 1506 1536 1674 1858 1950 2242 KPH-190P 190 830 912 968 1055 1181 1205 1301 1405 1517 1684 1717 1871 2077 2180 2507 KPH-200P 200 874 960 1019 1110 1243 1268 1369 1478 1596 1771 1806 1968 2184 2293 2637 KPH-250P 250 1092 1200 1274 1388 1554 1585 1711 1847 1994 2213 2257 2460 2730 2866 3296 KPH-275P 275 1201 1320 1402 1528 1711 1745 1884 2034 2196 2437 2485 2708 3005 3155 3628 KPH-300P 300 1310 1440 1529 1666 1866 1903 2055 2219 2396 2659 2712 2956 3281 3445 3961

Discharge Performance KPH Current (Amps) to 1.10V/Cell @ 20 C (68 F) Discharge Time in Minutes 60 45 30 20 15 10 5 1 Cell Type C5 (Ah) Discharge Current (A) KPH-20P 20 16.8 20.9 28.4 35.0 40.0 45.0 53.0 74.0 KPH-24P 24 20.2 24.8 33.3 42.0 47.0 52.0 61.0 85.0 KPH-30P 30 25.2 31.0 42.6 53.0 60.0 67.0 76.0 106.0 KPH-40P 40 33.6 42.0 56.8 70.0 82.0 91.0 105.0 147.0 KPH-60P 60 50.4 63.0 85.2 106.0 126.0 141.0 156.0 218.0 KPH-70P 70 58.8 70.6 99.4 124.0 148.0 164.0 184.0 258.0 KPH-80P 80 67.2 81.4 113.6 141.0 170.0 188.0 212.0 296.0 KPH-100P 100 84.0 101.7 142.0 177.0 195.0 216.0 263.0 368.0 KPH-120P 120 100.8 122.2 170.4 212.0 234.0 259.0 317.0 443.0 KPH-140P 140 117.6 142.2 198.8 247.0 273.0 303.0 369.0 517.0 KPH-155P 155 130.2 158.0 220.1 274.0 302.0 335.0 407.0 570.0 KPH-170P 170 142.8 173.2 241.4 301.0 331.0 368.0 450.0 629.0 KPH-190P 190 159.6 194.0 269.8 336.0 370.0 411.0 502.0 703.0 KPH-200P 200 168.0 204.3 284.0 354.0 390.0 433.0 526.0 737.0 KPH-250P 250 210.0 256.0 355.0 442.0 487.0 541.0 658.0 921.0 KPH-275P 275 231.0 281.8 390.5 486.0 536.0 595.0 727.0 1018.0 KPH-300P 300 252.0 308.0 426.0 531.0 585.0 649.0 791.0 1108.0 Current (Amps) to 1.05V/Cell @ 20 C (68 F) Discharge Time in Minutes 60 45 30 20 15 10 5 1 Cell Type C5 (Ah) Discharge Current (A) KPH-20P 20 18.2 25.9 32.2 41.0 47.0 53.0 64.0 90.0 KPH-24P 24 21.9 31.2 38.7 49.0 56.0 64.0 76.8 108.0 KPH-30P 30 27.3 38.8 48.3 61.0 70.0 79.5 96.0 135.0 KPH-40P 40 36.4 51.7 64.4 82.0 94.0 106.0 128.0 180.0 KPH-60P 60 54.6 85.2 96.6 123.0 141.0 159.0 192.0 258.0 KPH-70P 70 63.7 99.4 112.7 143.0 164.0 185.0 224.0 301.0 KPH-80P 80 72.8 103.4 128.8 164.0 188.0 212.0 256.0 344.0 KPH-100P 100 91.0 129.2 161.0 205.0 235.0 265.0 320.0 414.0 KPH-120P 120 109.2 155.1 193.2 246.0 282.0 318.0 384.0 498.0 KPH-140P 140 127.4 180.1 225.4 287.0 329.0 371.0 448.0 525.0 KPH-155P 155 141.1 200.4 249.6 317.0 364.0 410.8 496.0 593.0 KPH-170P 170 154.7 219.7 273.7 348.0 400.0 450.0 544.0 650.0 KPH-190P 190 172.9 245.5 305.9 389.0 446.0 503.0 608.0 728.0 KPH-200P 200 182.0 258.4 322.0 410.0 470.0 530.0 640.0 766.0 KPH-250P 250 227.5 323.0 402.5 512.0 587.0 662.0 800.0 958.0 KPH-275P 275 250.3 355.4 442.8 563.0 646.0 728.0 880.0 1055.0 KPH-300P 300 273.0 387.7 483.0 615.0 705.0 795.0 960.0 1149.0

Battery Racks Features Flexibility Modular Design allows for system versatility and ease of set-up and movement. Plastic acid-resistant adjustable isolators are provided to permit leveling up to 0.6". Strength All main rack components are made of powder-coated steel. Protection All Steel parts are completely powder-coated with black or gray polyethylene for electrolyte protection and electrical insulation. Optional Seismic-rated Configuration Available With optional components, AlphaRac TM battery racks become seismic-rated system suitable for use in earthquake-prone areas. Seismic-rated AlphaRac battery racks are designed to meet the requirements for IEEE 693-2005, IBC 2006 and CBC 2007. Iso view, two-step battery rack Custom Designed Racks Special applications and unusual installation locations often require an adaptable, unique battery rack. Custom configured AlphaRac battery racks are modular and can be designed to meet almost any requirement. Front view, two-step battery rack Iso view, two-tier, two-step battery rack For more information visit www.alpha.com Alpha Industrial Power United States Suwanee, Georgia Tel: 800 996 6104 Fax: 678 584 9259 Alpha Industrial Power reserves the right to make changes to the products and information contained in this document without notice. 2011 Alpha Industrial Power. All Rights Reserved. Alpha is a registered trademark of Alpha Technologies. member of The Alpha Group is a trademark of Alpha Technologies. AlphaCell is a trademark of Alpha Technologies. 049-381-10-001 (11/11)