SAFR LED SERIES Hazardous Location LED Luminaire Class I, Division 2, Groups A, B, C & D Class II, Division & 2, Groups E, F & G Class III Class I, Zone 2, Groups IIA, IIB & IIC UL 8750 LED Safety UL 844 Hazardous Locations UL 598 Wet Locations UL 598A Marine Outside Type NEMA 3R & 4X IP66 CUL ABS Type Approved Tested to LM 79 & LM 80 Enclosed & Gasketed US Patent # D637,339S S A F R L E D 77
SAFR LED SERIES Large hinge permits fixture to open for hands free wiring. Also allows better heat dissipation of internal components. Hazardous Location LED Luminaire Housing and outlet boxes are high strength, corrosion resistant copper-free cast aluminum alloy. Superior heat resistant silicone o-ring gasket makes fixture suitable for installation indooors or outdoors. Other materials available. All external hardware is stainless steel. Stainless steel inserts are available as an option. All exterior surfaces are covered with corrosion and chemical resistant baked epoxy. Available with deep prismatic glass, clear low-profile or frosted low-profile glass globes. Suitable for installation on marine environments where equipment is subject to salt water spray, either indoor or outdoor. UL 844 Hazardous Locations UL 8750 LED Safety UL 598A Marine Outdoor Enclosed and Gasketed Suitable for wet locations Suitable for hose down applications 78 RIG-A-LITE
Catalog Number Logic BASIC SERIES SAFR Hazardous Location LED Class I, Division 2, Groups A, B, C & D Class II, Division & 2, Groups E, F & G Class III Simultaneous Presence Class I, Zone 2, Groups IIA, IIB & IIC Enclosed and Gasketed Wet Locations NEMA 3R, 4X; IP66 UL 598, UL598A, UL844 & UL8750 CUL ABS Type Approved 2 3 4 LAMP CURRENT/LAMP WATTAGE 09 = 70 Watts = 96 Watts LAMP TYPE L2 = LED LED Hazardous Locations Class I, Division 2 Class II Class III UL 598, 598A, 844 & 8750 Wet Locations CUL DRIVER VOLTAGE U = 20 to 277V 50/60 HZ N = 347/480V 60 HZ Certification Guide Model Watts Type SAFR-09-L2-U-LFG-C- XX 2 3 4 5 6 7 Ambient Temperature C 5 GLOBE & GUARD LC = Low Profile Clear Glass Globe Only LCG = Low Profile Clear Glass Globe & Guard LF = Low Profile Frosted Glass Globe Only LFG = Low Profile Frosted Glass Globe & Guard T5 = Type V (Symmetric) Closed Bottom Glass Refractor T5G = Type V (Symmetric) Closed Bottom Glass Refractor & Guard 6 MOUNTING STYLE P = " Pendant Mount P = " Pendant Mount C = " Ceiling Mount C = " Ceiling Mount W = " Wall Mount W = " Wall Mount S = -/4" 25 Stanchion Mount S = -/2" 25 Stanchion Mount L = -/4 90 Stanchion Mount L = -/2 90 Stanchion Mount K = " Cone Top K = " Cone Top 7 Class I, Div.2 Groups A,B,C & D OPTIONS SS = Stainless Steel Inserts (304) FB = Single Fuse Block 2,3 FB2 = Double Fuse Block 2,3 SC = Safety Cable SP = Surge Protector CLASS Il, Div. Groups E, F & G Class III Simultaneous Presence Consult factory for pricing 2 Not available unless incoming voltage is specified. When installed, one fuse block is provided for 20, 277V and two fuse blocks are provided for 208, 220, 240V. Fuse not included. Not available on 347V or 480V 3 Fuse option not available for marine listed fixtures. Supply Wire Suitable Temp C UL 598A Outdoor SAFR09 70 LED 40 T4 T6 T3B 75 YES YES SAFR09 70 LED 55 T4 T6 T3B 75 YES YES SAFR 96 LED 40 T4A T6 T3C 90 YES YES SAFR 96 LED 55 T4A T6 T3C 90 YES YES CUL Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts. www.rigalite.com 79
Hazardous Locations Class I, Division 2 Class II Class III UL 598, 598A, 844 & 8750 Wet Locations CUL 70 Watt Threaded Refractor and Guard Mounting Style Conduit Size (in.) Catalog Number 20V thru 277V 50/60HZ (lbs.) Ballast Housing CONSISTS OF Outlet Box Refractor Guard RIGID PENDANT SAFR09-L2-U-T5-G-P SAFR09-L2-U-T5-G-P 2.2 2.2 SMP SMP CEILING MOUNT SAFR09-L2-U-T5-G-C SAFR09-L2-U-T5-G-C 22.0 22.0 SMC SMC WALL MOUNT SAFR09-L2-U-T5-G-W SAFR09-L2-U-T5-G-W 2.2 2.2 SMW SMW 25 STANCHION MOUNT -/4 -/2 SAFR09-L2-U-T5-G-S SAFR09-L2-U-T5-G-S 2.2 2.2 SMS SMS 90 STANCHION MOUNT -/4 -/2 SAFR09-L2-U-T5-G-L SAFR09-L2-U-T5-G-L 22.0 22.0 SML SML 80 RIG-A-LITE
Hazardous Locations Class I, Division 2 Class II Class III UL 598, 598A, 844 & 8750 Wet Locations CUL 70 Watt Low Profile Clear Globe and Guard Mounting Style Conduit Size (in.) Catalog Number 20V thru 277V 50/60HZ (lbs.) Ballast Housing CONSISTS OF Outlet Box Globe Guard RIGID PENDANT SAFR09-L2-U-LCG-P SAFR09-L2-U-LCG-P SMP SMP CEILING MOUNT SAFR09-L2-U-LCG-C SAFR09-L2-U-LCG-C 8.0 8.0 SMC SMC WALL MOUNT SAFR09-L2-U-LCG-W SAFR09-L2-U-LCG-W SMW SMW 25 STANCHION MOUNT -/4 -/2 SAFR09-L2-U-LCG-S SAFR09-L2-U-LCG-S SMS SMS 90 STANCHION MOUNT -/4 -/2 SAFR09-L2-U-LCG-L SAFR09-L2-U-LCG-L 8.0 8.0 SML SML www.rigalite.com 8
Hazardous Locations Class I, Division 2 Class II Class III UL 598, 598A, 844 & 8750 Wet Locations CUL 70 Watt Low Profile Frosted Globe and Guard Mounting Style Conduit Size (in.) Catalog Number 20V thru 277V 50/60HZ (lbs.) Ballast Housing CONSISTS OF Outlet Box Globe Guard RIGID PENDANT SAFR09-L2-U-LFG-P SAFR09-L2-U-LFG-P SMP SMP CEILING MOUNT SAFR09-L2-U-LFG-C SAFR09-L2-U-LFG-C 8.0 8.0 SMC SMC WALL MOUNT SAFR09-L2-U-LFG-W SAFR09-L2-U-LFG-W SMW SMW 25 STANCHION MOUNT -/4 -/2 SAFR09-L2-U-LFG-S SAFR09-L2-U-LFG-S SMS SMS 90 STANCHION MOUNT -/4 -/2 SAFR09-L2-U-LFG-L SAFR09-L2-U-LFG-L 8.0 8.0 SML SML 82 RIG-A-LITE
Hazardous Locations Class I, Division 2 Class II Class III UL 598, 598A, 844 & 8750 Wet Locations CUL LCXX Candlepower Distribution Deg. Parl. 0 3094 5 2784 0 2324 5 270 20 2223 25 260 30 959 35 2076 40 295 45 754 50 439 55 209 60 96 65 644 70 436 75 350 80 44 85 06 90 57 Total Lumens 6796.0 Input Power 65.96 (watts) Efficacy 03.03 (Lumens/Watt) CRI 74 CCT 4755 LFXX Candlepower Distribution Deg. Parl. 0 925 5 99 0 897 5 859 20 802 25 723 30 627 35 52 40 39 45 258 50 24 55 986 60 850 65 720 Total Lumens 6087.70 Input Power 65.89 (watts) www.rigalite.com 70 589 75 464 80 346 85 254 90 79 Efficacy 92.39 (Lumens/Watt) CRI 74 CCT 4760 83
Hazardous Locations Class I, Division 2 Class II Class III UL 598, 598A, 844 & 8750 Wet Locations CUL 96 Watt Threaded Refractor and Guard Mounting Style Conduit Size (in.) Catalog Number 20V thru 277V 50/60HZ (lbs.) Ballast Housing CONSISTS OF Outlet Box Globe Guard RIGID PENDANT SAFR-L2-U-T5-G-P SAFR-L2-U-T5-G-P 2.7 2.7 SMP SMP CEILING MOUNT SAFR-L2-U-T5-G-C SAFR-L2-U-T5-G-C 22.5 22.5 SMC SMC WALL MOUNT SAFR-L2-U-T5-G-W SAFR-L2-U-T5-G-W 2.2 2.2 SMW SMW 25 STANCHION MOUNT -/4 -/2 SAFR-L2-U-T5-G-S SAFR-L2-U-T5-G-S 2.2 2.2 SMS SMS 90 STANCHION MOUNT -/4 -/2 SAFR-L2-U-T5-G-L SAFR-L2-U-T5-G-L 22.0 22.0 SML SML 84 RIG-A-LITE
Hazardous Locations Class I, Division 2 Class II Class III UL 598, 598A, 844 & 8750 Wet Locations CUL 96 Watt Low Profile Clear Globe and Guard Mounting Style RIGID PENDANT Conduit Size (in.) Catalog Number 20V thru 277V 50/60HZ (lbs.) Ballast Housing CONSISTS OF Outlet Box Globe Guard SAFR-L2-U-LCG-P SAFR-L2-U-LCG-P SMP SMP CEILING MOUNT SAFR-L2-U-LCG-C SAFR-L2-U-LCG-C 8.0 8.0 SMC SMC WALL MOUNT SAFR-L2-U-LCG-W SAFR-L2-U-LCG-W SMW SMW 25 STANCHION MOUNT -/4 -/2 SAFR-L2-U-LCG-S SAFR-L2-U-LCG-S SMS SMS 90 STANCHION MOUNT -/4 -/2 SAFR-L2-U-LCG-L SAFR-L2-U-LCG-L 8.0 8.0 SML SML www.rigalite.com 85
Hazardous Locations Class I, Division 2 Class II Class III UL 598, 598A, 844 & 8750 Wet Locations CUL 96 Watt Low Profile Frosted Globe and Guard Mounting Style RIGID PENDANT Conduit Size (in.) Catalog Number 20V thru 277V 50/60HZ (lbs.) Ballast Housing CONSISTS OF Outlet Box Globe Guard SAFR-L2-U-LFG-P SAFR-L2-U-LFG-P SMP SMP CEILING MOUNT SAFR-L2-U-LFG-C SAFR-L2-U-LFG-C 8.0 8.0 SMC SMC WALL MOUNT SAFR-L2-U-LFG-W SAFR-L2-U-LFG-W SMW SMW 25 STANCHION MOUNT -/4 -/2 SAFR-L2-U-LFG-S SAFR-L2-U-LFG-S SMS SMS 90 STANCHION MOUNT -/4 -/2 SAFR-L2-U-LFG-L SAFR-L2-U-LFG-L 8.0 8.0 SML SML 86 RIG-A-LITE
Hazardous Locations Class I, Division 2 Class II Class III UL 598, 598A, 844 & 8750 Wet Locations CUL LCXX Candlepower Distribution Deg. Parl. 0 3228 5 3276 0 3272 5 3344 20 327 25 2966 30 2953 35 2920 40 2560 45 2327 50 2283 55 89 60 323 65 922 70 630 75 486 80 95 85 49 90 80 Total Lumens 9570.48 Input Power 92.0 (watts) Efficacy 04.03 (Lumens/Watt) CRI 75 CCT 4798 LFXX Candlepower Distribution Deg. Parl. 0 2682 5 2669 0 2634 5 2577 20 2496 25 239 30 2268 35 222 40 965 45 79 50 62 55 423 60 233 65 040 Total Lumens 860.05 Input Power 9.74 (watts) www.rigalite.com 70 842 75 655 80 483 85 35 90 254 Efficacy 93.85 (Lumens/Watt) CRI 75 CCT 4807 87
Hazardous Locations Class I, Division 2 Class II Class III UL 598, 598A, 844 & 8750 Wet Locations CUL 88 RIG-A-LITE
Hazardous Locations Class I, Division 2 Class II Class III UL 598, 598A, 844 & 8750 Wet Locations CUL www.rigalite.com 89
Hazardous Locations Class I, Division 2 Class II Class III UL 598, 598A, 844 & 8750 Wet Locations CUL Accessories Conduit Outlet Boxes Catalog No. Hub Size (In.) (Lbs.) Rigid Pendant Ceiling Mount SMP 3.3 SMP 3.3 SMC 4. Catalog Photo Cell Kit* No. Description (Lbs.) * Not Suitable for hazardous locations. SPH25-20 Automatic on-off switch at predetermined light levels. 20 volt only. REQUIRES FIELD INSTALLATION..9 SMC 4. Cone Mount Wall Mount SMK 4.5 SMK 4.5 SMW 7.8 SMW 7.8 Hazardous Location Catalog Photo Cell Kit* No. Description (Lbs.) HLP-20 HLP-208-277 Automatic on-off switch at predetermined light levels. (20 volt only) REQUIRES FIELD INSTALLATION..25.25 Stanchion Mount (25 ) SMS -/4 5.9 SMS -/2 5.9 Stanchion Mount (90 ) SML -/4 5.9 SML -/2 5.9 90 RIG-A-LITE
Hazardous Locations Class I, Division 2 Class II Class III UL 598, 598A, 844 & 8750 Wet Locations CUL Accessories Catalog Guards/Fuse Kit No. Description (Lbs.) Stainless Steel Wire Guard for Type, 3 & 5 refractors.5 Catalog Glass Globe No. Description (Lbs.) IES Type V light distribution (asymmetrical) 6.6 Stainless Steel Wire Guard for Low Profile Clear and Frosted Globes.0 Low Profile Clear Globe 4.2 SBF600 Open fuse block kit- 600 volt AC maximum..5 Low Profile Frosted Globe 4.2 Fixtures ordered with refractors are not suitable to be ordered with reflectors. www.rigalite.com 9