Portable Binocular Microscope Microscope binoculaire portatif Microscopio binocular portátil

Similar documents
Preface. Scope of Application. General Requirements for Safety THE SAFETY MARKS USED IN THIS INSTRUMENT

MANUAL EXC-120 MICROSCOPE SERIES. 73 Mall Drive, Commack, NY (P) (F)

OPERATING INSTRUCTIONS

Stereo Microscopes Instruction Manual

Keeler Spectra Plus. Instructions. Next

XPERT SL 45 Slit Lamp. Instruction Manual

LED-HL2-CMP LED Headlight System Operation Manual

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

PLATE LOUPE PL-2 INSTRUCTION MANUAL. NEITZ INSTRUMENTS CO., LTD. International Division

INSTRUMENTS FOR ENT OPHTHALMOLOGICAL INSTRUMENTS. uni /econom. The reliable classic for everyday use.

ALU-29CF Portable Light NSN:

Microscope light manual

PRIMA DNT User Manual

SO-801 HAND-HELD SLIT LAMP SO-801

LED HANDHELD SLIT LAMP

USER MANUAL SLIT LAMP MICROSCOPE

Rechargeable laryngoscope handles Directions for use

RemRest. Service Manual. CAUTION: USA Federal law restricts this device to sale by or on the order of a physician. P/N Rev A

LED DayLite WireLess Mini

SZ2-ILA INSTRUCTIONS TRANSMITTED ILLUMINATION ATTACHMENT SZ-ADD SZ-POL-2 SZH-CLJ. Optional Modules

LED DayLite Micro. User Guide Ver

SCAN OPTICS SO-161-R MICROSCOPE USER MANUAL

PRECISION MICROSCOPES

Spotlight 1,000,000 Power Series Cordless Rechargeable

User s Manual Dental Microscope LED

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

XCEL 250 XCEL 400/700. Xcel Slit Lamp USER'S GUIDE Rev. F Page1

HLC CEILING MOUNTED DENTAL LIGHT. INSTALLATION and OPERATING INSTRUCTIONS. Rev.3

Introduction. The words WARNING, CAUTION and NOTE carry special meanings and should be carefully reviewed.

AP250 Automated Projector

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

Swing Arm Magnifying Lamp

USER MANUAL. SLIT LAMP MICROSCOPE Model: GR-7. Version: 1.0. Gilras LLC

AMCON AUTOMATIC CHART PROJECTOR USER S MANUAL EQ-6002

Rectal Light Handle REF V Power Supply REF 73305, 73322, 73324, 73326

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité

12 Volt dc supply Connecting the power supply to a 12 Volt dc supply (battery)... 12

Fiber Optic Illuminator. Model 21AC Model 21DC

USER S MANUAL & WARRANTY INFORMATION

CENTERING DEVICE. Model CE-1 OPERATOR S MANUAL

OCTA FLUORESCENT 7 SOCKET FIXTURE

OPERATION MANUAL MODEL MODEL MODEL MODEL MODEL NON-CONDUCTIVE ARTICULATING FIBERSCOPE INSTRUMENT TECHNOLOGY, INC.

UNPACKING THE UNIT. Alcohol cleaning pad

Automatic Emergency Light

16V Cordless drill / driver PAGe 6 eng 16 Voltios taladro inalambrico PAGe 11 esp PerCeuse / tournevis à 16V PAGe 17 Fre rk2600k2

Visit us on the web at

OWNER'S MANUAL POWER BOOSTER. Rechargeable 12 Volt DC power supply. Item # Enclose copy of original sales receipt

Register your product within 30 days of purchase to activate your one-year limited manufacturer s warranty at ovente.com/register

uni / econom The reliable classic for everyday use. Instruments for ENT Ophthalmological instruments

Installation Instructions Central Battery Units

XENON 300 LIGHT SOURCE

Electrometer NiCad Battery Replacement

LIGHT AND POWER SOURCES POWER SOURCES

Operation and care of the Visual Optics Fiber Scopes

Model 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

IMPORTANT: SAFETY INSTRUCTIONS

INTRODUCTION...5 PARTS LIST...6 PACKAGING...9

TECHNICAL MANUAL. FOR BLAST 2 (Bright Light Aiming System Tactical 2) For Rifles and Pistols Equipped with MIL-SPEC-1913 and Picatinny Rails

Quickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

HEINE mini NT charger set for mini 3000

FOURNISSEUR : CE MANUEL DOIT ÊTRE REMIS À L UTILISATEUR DE CE PRODUIT.

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

Welch Allyn Insight Wireless LED Binocular Indirect Ophthalmoscope. Directions for use

MOONRING 1.5 MOONRING 3

Prima OPH User Manual

Bulbs are not included. FF-OF4 Octa 4 Socket Fluorescent Fixture INSTRUCTIONS

OWNER S MANUAL & WARRANTY INFORMATION IMPORTANT SAFETY INFORMATION, SAVE THESE INSTRUCTIONS

Mania EF1 user manual

Operation Manual. Fiber Optic Illuminator FOI-150-UL FOI-150-REM-UL

Fluorescent Ring Light with Dimmer INSTRUCTIONS

354 Mobile Lighting System

Have a Bright Day! Nicholas Harmon President, Verilux, Inc.

Table of Contents. Classifications.. 5. Installation.,12. Focusing..14. Operating Instructions..15. Charts Description Maintenance...

PET UNIT DOSE TABLE INSTALLATION MANUAL FN: Rev A 1/18

Installation Guide for EcoBrite EndLite LED Light Fixtures

INTRODUCTION...5 PARTS LIST...6 PACKAGING...9 ASSEMBLY INSTRUCTIONS... 10

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

Instruction Guide 325/326/327

shadow focus floodlight SFS-300 INSTRUCTIONS

ASSEMBLY AND INSTALLATION INSTRUCTIONS

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

IR-500 Infrared Thermometer / Voltage Detector / Flashlight

Motion System Components Diagram. Note: #2 Mirror Cover and X-Axis Motor Cover have been removed for visibility. Maintenance.

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

XCEL 255 Slit Lamp USER'S GUIDE

OWNER S MANUAL / MANUAL DEL USUARIO / MANUEL D UTILISATION

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

SPOTLIGHT 30 MILLION CANDLEPOWER

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

Operation Manual. 354 / 355 Combination Lighting System MA475900

steady cool fluorescent IUF-55 INSTRUCTIONS

QA4 Surgery Trolley System Manual Function Operating Instructions

Flashlights Unlimited Xenopus Electronix Deep Purple 405 Premium Inspection Lantern Operations Guide

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems

Adjustable Radical Face Protector Owners Guide

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

LiteBox /FireBox / Operating Instructions. (Rechargeable) 99 Washington Street Melrose, MA Phone Toll Free

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

Transcription:

Portable Binocular Microscope Microscope binoculaire portatif Microscopio binocular portátil Operating Instructions...4 Instructions de fonctionnement...20 Instrucciones de operación...34

Content Symbols................................ 3 Standards Compliance...................... 3 Operating Instructions.....................4 Instrument Function........................ 4 Flat Surface Magnifier...................... 4 Description of Controls..................... 5 Adjustments............................. 6 Connecting to the Power Source.............. 9 Accessories............................ 10 Lamp Replacement....................... 10 Cleaning................................. 11 Maintenance............................. 11 Specifications............................. 11 Approvals................................ 11 Product and Accessory Ordering Information... 12 Power Sources (Portable and Direct Plug-In)... 13 Service and Warranty Information............ 16 Troubleshooting Guide..................... 17 Symboles............................... 19 Conformité aux normes.................... 19 Instructions de fonctionnement............20 Fonction de l instrument.................... 20 Loupe à surface plate..................... 20 Description des commandes................ 21 Réglages............................... 22 Branchement à la source d alimentation....... 25 Accessoires............................. 26 Nettoyage............................... 27 Entretien................................ 27 Caractéristiques techniques................. 27 Homologations........................... 27 Commande des produits et accessoires....... 28 Sources d alimentation (portative et directe enfichable)....................................... 29 Service et garantie........................ 32 iii

iv Símbolos................................ 33 Cumplimiento de normas................... 33 Instrucciones de operación...............34 Función del instrumento.................... 34 Lupa de superficie plana.................... 34 Descripción de los controles................. 35 Ajustes................................. 36 Conexión a la fuente de energía.............. 39 Limpieza................................ 41 Mantenimiento............................ 41 Especificaciones.......................... 41 Aprobaciones............................ 41 Información de pedido de productos y accesorios 42 Fuentes de energía (Portátil y de enchufado directo)........................................ 43 Servicio y garantía........................ 46

Thank you for purchasing the Welch Allyn LumiView Portable Binocular Microscope or Flat Surface Magnifier. To ensure accurate and reliable performance of your new instrument, please follow the operating and maintenance instructions found in this manual. IMPORTANT: The material outlined in this manual should be reviewed and understood prior to operation of the equipment. Nous vous remercions d avoir fait l acquisition du microscope binoculaire portatif ou la loupe à surface plate LumiView de Welch Allyn. Suivez les directives contenues dans ce manuel pour assurer le fonctionnement précis et fiable de votre nouvel instrument pendant de nombreuses années. IMPORTANT : Avant d utiliser l équipement, bien lire les instructions données dans ce manuel. Agradecemos su compra del Microscopio binocular portátil o Lupa de superficie plana LumiView de Welch Allyn. Para asegurar un rendimiento preciso y confiable de su nuevo instrumento, siga las instrucciones de operación y mantenimiento que se encuentran en este manual. IMPORTANTE: El material descrito en este manual debe ser revisado y entendido antes de operar el equipo. 1

2

Symbols CAUTION: Consult accompanying documents. Internally Powered Recycle NOTE: Provides supplemental information to the text and indicates a potentially hazardous situation, which, if not avoided, may result in property damage. Additionally, it highlights important information on the use of this equipment. Standards Compliance Listed Product ETL Laboratories Listed Standards UL 60601-1, CAN/CSA C22.2 No. 601.1-M90, IEC 601-1 3

Instrument Function This device offers binocular (both eyes) viewing, providing a three-dimensional stereoscopic view. This stereoscopic view is then magnified and illuminated to provide excellent tissue rendition. Portable Binocular Microscope When the binoculars are engaged, the visual pathways are displaced medially to allow for binocular vision in narrow cavities. Two diopters (1.5x) magnification improves vision. When the binoculars are rotated upwards, the scope becomes a convenient basic headlight. Flat Surface Magnifier The three diopter (2.5x) flat surface magnifier is available in either the headband model or the spectacle model. The magnifier can be flipped up for convenient headlight use. CAUTION: This device is not to be used in the presence of flammable anesthetics. CAUTION: DO NOT look directly into the light. This device contains a High Intensity Lamp. It is not to be used for illumination or examination of any portion of the eye, Posterior or Anterior. 4

Description of Controls Front View Back View 1. Interpupillary distance (IPD) controls 2. Lamp 3. Instrument vertical height adjustment 4. Binocular flip-up axis 5. Pivot mechanism 6. Height adjustment screw 7. Headband circumference adjustment knob 8. Comfort pads 9. Cable clips 10. Optical assembly Flat Surface Magnifier 11. Magnifier lens 12. Lens holder 13. Vertical adjustment screw 5

Adjustments Ratchet Style Headband Instructions Position the main body of the headband on the head so that the band fits comfortably on the forehead and low on the back of the head. Use the circumference adjustment knob to adjust the size. Optics Assembly The optics assembly can be adjusted to the desired position by manipulating the links in the pivot mechanism. The Optics Assembly should be positioned as close to the eyes as possible so that the eyes can gaze directly through the Optics Assembly. (Set optics per instructions provided with your LumiView.) With the lamp illuminated, check the adjustment by confirming that the light beam is centered in the visual field.if the light is high or low, refer to the detailed adjustment instructions provided with your LumiView. 6

Spectacle Model Optical Section Vertical Adjustment Loosen screw that attaches optical section spec tacles. Reposition optical section to insure proper alignment with user s eyes. Tighten screw to maintain optical section location. Adjusting for User Refractive Error (Spectacle Models Only) The optimal working distance from the object is 15" (38.1cm) - 17" (43.2cm). If this model is used without corrective lenses and user is myopic or hyperopic, then the user will need to work closer or farther from object, depending on refractive error. To compensate for this, the spectacle models can be fitted with corrective lenses by an e yecare practitioner of your choice. Please bring the following information to assist your ey ecare practitioner in fitting your prescription lenses. Lens Template Spectacle Model Front Sizes Eye A B ED D.B.L 51 51 43 57.4 18 7

Setting the Interpupillary Distance The Interpupillary Distance (IPD) Controls move the oculars and are located on the bottom of the optical section. These oculars move independently of one another. To set IPD properly, observe an object at approximately 15 inches (38cm). Close the left eye and adjust the IPD control under the right eye until the viewed image i s centered. Now close the right eye, keeping the left eye open, and adjust the IPD control for the left eye until that image is centered. Open both eyes and the object should be clear and centered. Flat Surface Magnifier Model Interpupillary Distance Controls Loosen screw that attaches the lamp section to the adjustment arm. Reposition the lamp section up or down to desired location and tighten screw. Place instrument on head. Adjust the flat surface magnifier by moving the lens holder up or down and the magnifier in or out. 8

Connecting to the Power Source NOTE: The instrument power cord must be plugged into either a Welch Allyn Portable Power Source No. 75260 or a Welch Allyn Direct Plug-In Power Source No. 75210. Portable Power Source CAUTION: The lamp housing becomes hot when the lamp is on for more than 5 minutes and can cause a burn if it contacts the skin. Allow at least 10 minutes for cooling between the uses of the illuminator. Plug instrument power cord into the power cord connector port on top of the power source. Push in until firmly in place. Gently screw the external connector sleeve clockwise to secure (optional). Attach the Portable Power Source by using the belt clip. The instrument is now ready for use. Direct Plug-in Power Source Plug Power cord from the Binocular microscope into the Direct Plug-in Power cord. Push in until firmly in place. Gently screw the external connector sleeve clockwise to sec ure (optional). Plug direct power source into a nearby receptacle. The instrument is now ready for use. 9

Accessories Pneumatic Speculum Holder A pneumatic speculum holder with a 4x s magnification lens can be used to aid in examination of the ear. Lamp Replacement CAUTION: Lamps may become very HOT. Be sure to allow lamps to cool before changing. To change the lamp, flip the binocular assembly into its up position. Remove the reflector assembly by placing the thumb on the notch located on the bottom of the reflector housing and pushing the reflector assembly. (Step 1) Remove lamp and insert a new Welch Allyn lamp No. 08500 into the back of the reflector. (Step 2) Replace reflector housing into instrument and push until it snaps into place. NOTE: Reflector assembly air vents should be positioned top and bottom. 10 Step 1 Step 2

Cleaning All glass surfaces, portable binocular microscope lenses, ocular or eyepiece covers and lamp reflective covers can be cleaned with a soft cloth moistened with alcohol. The exterior surfaces of the portable binocular microscope and power sources can be wiped clean with a soft cloth moistened with alcohol. NOTE: Avoid using harsh cleansing fluids or excessively moistened cloths on any portion of the instrument. To clean the Reusable Specula: 1. Rinse the Reusable Specula with warm tap water for one minute. 2. Soak the Reusable Specula in 70% isopropyl alcohol for 20 minutes. 3. Rinse Reusable Specula with tap water and air dry. Maintenance Lamp replacement and cleaning may be performed by the user on an as needed basis. Additional servicing should be performed by returning the instrument to an authorized Welch Allyn Technical Service Department or distributor. See Service and Warranty Information section. Specifications Interpupillary Distance Light Source Headband Adjustment Range Weight (No. 20500S) Transport and Storage 49mm to 74mm 3.60V, Halogen Small, Medium and Large 80g -20 C to 40 C, 95% RH maximum Approvals UL 60601-1, CAN/CSA NO. 601.1-M90 IEC 601-1 11

Product and Accessory Ordering Information Product No. Instrument Description No. 20500S Spectacle LumiView REF 20501 with Portable Power Source REF 75200 and Charger REF 74810 No. 20510S Spectacle LumiView REF 20501 with Direct Plug-In Power Source REF 75210 No. 20500H Headband LumiView REF 20501 with Portable Power Source REF 75200 and Charger REF 74810 No. 20510H Headband LumiView REF 20501 with Direct Plug-In Power Source REF 75210 No. 20530S No. 20530H Spectacle LumiView REF 20501 w/o Power Source Headband LumiView REF 20501 w/o Power Source No. 20520S Spectacle Flat Surface Magnifier REF 20521 w/ Portable Power Source REF 75200 and Charger 74180 No. 20520H Headband Flat Surface Magnifier REF 20521 w/portable Power Source REF 75200 and Charger REF 74180 No. 20540S No. 20540H Spectacle Flat Surface Magnifier REF 20521 w/o Power Source Headband Flat Surface Magnifier REF 20521 w/o Power Source Power Sources No. 75260 Portable Power Source REF 75200 w/charger REF 74180 No. 75265 Portable Power Source REF 75200 w/international Charger (specify country and voltage) No. 74180 Charger REF 74180 only for Portable Power Source REF 75200 No. 74185 International Charger only for Portable Power Source REF 75200 (specify country and voltage) No. 75210 Direct Plug-In Power Source REF 75210 No. 75215 International Direct Plug-In Power Source (specify country and voltage) NOTE: The power source options listed above operate with all instrument configurations. No. 08500-U No. 205007-501 Accessories Replacement Lamp for Device (all models) Replacement Reflector Assembly No. 72250 Replacement Battery for Portable Power Source REF 75200 No. 21505 No. 21502 No. 22002 No. 22003 No. 22004 No. 22005 Insufflation Bulb System for LumiView Models Pneumatic Speculum Holder with Specula for LumiView models Poly Speculum 2mm Poly Speculum 3mm Poly Speculum 4mm Poly Speculum 5mm No. 22009 Poly Speculum 9mm No. 05374-U Hard case NOTE: Only accessories and power sources indicated in this manual are to be used with the Portable Binocular Microscope and Flat Surface Magnifier. 12

Power Sources (Portable and Direct Plug-In) Portable Power Source (Welch Allyn Model No. 75200) This power source is designed for use in both the office and the hospital and is ideal for carrying to satellite offices. Power On time is 90 minutes after a full charge of 16 hours. Features: 1. On/Off Switch 2. Instrument Connector 3. Charging Transformer Port 4. Charging Indicator 5. Belt Clip 6. Spare Lamp Receptacle Specifications: Battery Type Welch Allyn #72250 (nickel-cadmium) Voltage/Capacity 3.6 VDC/1.8 Ahr Charger Welch Allyn #74180 (for international orders, specify country) 13

Connecting Instrument to Portable Power Source: Plug instrument power cord into the power cord connector port on top of the power source. Push in until firmly in place. Gently screw the external connector sleeve clockwise to secure (optional). Recharging the Portable Power Source: Turn portable power source off. Disconnect instrument from power source. Plug charging transformer into portable power source. Plug charging transformer into wall socket. LED light indicates unit is charging. Disconnect charging transformer from power source when fully charged, after 14-16 hours. Accessing Spare Lamp Lift the spare lamp out of its receptacle and use. 14

Battery Replacement Be sure power is off. Remove both screws from back of power source with Phillips head screwdriver. Grasp the belt clip, gently pull back and down on the housing. (Steps 2 and 3) Lift battery out and unplug from unit. Replace with new battery and reverse above steps. NOTE: Power source housing screws must be securely tightened in order to properly hold electrical components in place. Battery Disposal Nickel-cadmium battery. Battery must be recycled or disposed of properly. Direct Plug-In Transformer Plug Power cord from the binocular otoscope into the Direct Plug-In Power cord. Push in until firmly in place. Gently screw the external connector sleeve clockwise to secure (optional). The instrument is now ready for use. Plug direct power source into a nearby receptacle. 15

Service and Warranty Information Service For customers in North America, please return instruments requiring service to a Welch Allyn Technical Service Department listed below or to an authorized Welch Allyn distributor. Technical Service Department Welch Allyn, Inc. 4341 State Street Road Skaneateles Falls, NY 13153-0220 U.S.A. Telephone: 800-535-6663 (in U.S.A. only) or (315) 685-4560 Fax: 315-685-4653 For customers outside of North America, return your unit to a local, authorized Welch Allyn distributor or to your nearest Welch Allyn service center. Warranty Welch Allyn, Inc. warrants the Portable Binocular Microscope and Flat Surface Magnifier to be free of original defects in material and workmanship and to perform in accordance with manufacturer s specifications for a period of one year from the date of purchase. If this instrument or any component thereof is found to be defective or at variance with the manufacturer s specifications during the warranty period, Welch Allyn will repair or replace the instrument or component(s) at no cost to the purchaser. This warranty only applies to instruments purchased new from Welch Allyn or its authorized distributors or representatives. The purchaser must return the instrument directly to Welch Allyn or an authorized distributor or representative and bear the costs of shipping. This warranty does not cover breakage or failure due to tampering, misuse, neglect, accidents, modification or shipping, and is void if the instrument is not used in accordance with manufacturer s recommendations or if repaired or serviced by other than Welch Allyn or a Welch Allyn authorized representative. No other express or implied warranty is given. 16

Troubleshooting Guide Problem Illumination spot is too high and is out of field of view. Solution Make sure you are 14" to 16" from patient or object under inspection. If you are too close, the illumination spot will be too high. Make sure optical section is aligned with user s eyes. Suggest looking into the instrument when on user. The user s eyes should be centered vertically on the center mirrors. User encounters glare off of the pneumatic insufflation system. To correct A and B, simply loosen screw on back of optical section and adjust optical section up or down until image is centered. Clean the glass section with alcohol swab or clean cotton cloth. Rotate pneumatic assembly until glare dissipates. 17

Problem Instrument does not illuminate. Image is distorted or double image is seen. How do I utilize bifocals? Solution Replace 08500 lamp. See page 11 for instructions. Battery is expired or discharged. See page 15 and 16. Instrument must be set correctly for interpupillary distance adjustment. See page 9 for instructions. Depth perception is slightly altered with 3D optical design. Continued usage will improve comfort level. Install bifocal lenses so that only the upper third is for distance and lower two-thirds is for reading. Adjust the nose bridge so that frame sits higher on nose. Then lower the height adjustment. This will ensure that the binocular viewing system will be positioned in front of the reading part of the lenses. 18