Photovoltaic Solar Energy Modular Trainers

Similar documents
Photovoltaic Solar Energy Modular Trainers

Photovoltaic Solar Energy Unit EESFB

Wind Energy Unit EEE. Engineering and Technical Teaching Equipment PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Electronic console

DC Brushless Motor Application AEL-DCBRA

MGI. Gyroscope PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Engineering and Technical Teaching Equipment

Screenshot of the computer data acquisition and calculations software INTRODUCTION

Application of AC Three-Phase Induction Motor of Squirrel Cage AEL-ACINA

INTRODUCTION. AC motor operations, most widely used motor is three phase induction motor. This type of motor does not require any starting device

Fluid Friction in Pipes, with Hydraulics Bench (FME00) AFT

Application of AC Dahlander Three-Phase Induction Motor AEL-ACDHA

Application of AC Three-Phase Induction Motor of Wound Rotor AEL-ACWRA

Biodiesel Process Unit EBDB

Transparent and Functional Motors Application AEL-FTM

Basic Unit of Mechanical Drive Systems MDSU. Engineering and Technical Teaching Equipment INTRODUCTION GENERAL DESCRIPTION

Motor-Generator and Transformer Construction Application AEL-MGTC

TECNEL. Computer Controlled Teaching Unit for the Study of Power Electronics. (Converters:DC/AC+AC/DC+DC/DC+AC/AC)

Final User Smart Grid Trainer AEL-FUSG

Assembly and Maintenance of Pumps AMP

Solar power training packages From basic to industrial concepts

Energy Power Plants Trainer AEL-EPP

RENEWABLE ENERGY TRAINER

Off-grid Power for Wireless Networks. Training materials for wireless trainers

renewable energy and energy efficiency

New & Renewable Energy

FIELD TEST GUIDE PLEASE READ THIS GUIDE COMPLETELY BEFORE TAKING ANY ACTION

renewable energy and energy efficiency

UNC-Charlotte's Power Engineering Teaching lab

Computer Controlled Heat Exchangers Training System, with SCADA and PID Control TICC

Hybrid and Electric Vehicles

Solar Energy Trainer. Experiments:

Autonomous Power Supply Uninterruptible Power Supply (UPS)

PROVA 1011 Solar System Analyzer

AEL-4. Advanced Electrical Laboratories (AEL-LABS): Electromechanical Constructions Lab. Engineering and Technical Teaching Equipment

Electrical Power Systems 2014/15

Distribution division. Solar Photovoltaic Catalogue. Premier Plaan. Smart solutions for the solar energy sector around the world

Steca Elektronik INVERTER / CHARGER WITH MPPT: SOLARIX PLI

SOLAR ENERGY KIT MODEL: SISMA-CT20000

KIT SOLAR MONTE PERDIDO

Energy & Cost Savings The Friends Meeting of Austin 3701 Martin Luther King Blvd. Austin, TX (46) Sharp 208 W Modules = 9.

SPECIAL SPECIFICATION 6576 Solar Panel Power Supply System

Section 7: Price Schedule Form 1

Station Identification. Results. PV System Specifications. Energy Specifications. Solar Radiation (kwh/m 2 /day) Energy Value ($) AC Energy (kwh)

Conergy PH 185M 200M. Special Edition Australia. Specifications Photovoltaic modules

HIGH VOLTAGE MODULE TEST SYSTEM

40 Módulos FV TRINA SOLAR 265Wp Policristalino (Estructura Incluida) 1 Inversor KACO Blueplanet 10,0 TL3

Available online at ScienceDirect. Energy Procedia 36 (2013 )

EDIBON SCADA System and PID Control included. 2 Control Interface Box. 1 TIUS. Base Service Unit. Cables and Accessories Manuals. TIPL.

Test Catalogue. Solar Photovoltaic & Energy Efficiency

Installation Manual. Opal Solar QSA Series

Power Conversion System The Best Technology for your photovoltaic and storage system

Development of Novel Connection Control Method for Small Scale Solar - Wind Hybrid Power Plant

Photovoltaics. MPI Hybrid Series

Product Catalogue. Europe

Solar module user manual Conergy PM 225P-250P

Solar off-grid Inverter. SP Junior Series. User Manual

Steca Elektronik SOLARIX PLI

Sun Sensor setting in PumpScanner Daily output in average month 52 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Design of Active and Reactive Power Control of Grid Tied Photovoltaics

3 Phase Power Systems - Designed for Canada

ESCI 61- PV Cells Modules and Arrays April 21- Week 3 Agenda

Wind Energy System.

Produce your. current. by yourself. There is no easier way!

Development of the Single Phase PV Inverter SANUPS P61A

ACSEP - Applications and Control of Power Electronic Systems

Design of a Low Voltage DC Microgrid Based on Renewable Energy to be Applied in Communities where Grid Connection is not Available

400W / 600W / 1000W / 1500W DIY Wind Turbine

SOLAR PHOTOVOLTAIC V-SYS ULTRA - FLEXI - ON FLOOR - ON TOP. MADE IN FRANCE

P H O T O V O LTA I C

Solar inverter AX-series

Solar Kit Lesson #13 Solarize a Toy

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Conclusions. Fall 2010

Datasheets. Residential On-Grid Photovoltaic System Kits

Photovoltaic System Overcurrent Protection

Glossary. * Credit for glossary starter: Florida Solar Energy Center. August 2015 PV Installer's Course: Glossary 1

Wind-Solar Hybrid Power Generation Systems. Energy Pvt. Ltd.

Exercise 3. Battery Charging Fundamentals EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Charging fundamentals

IRXPE - Renewable Integration in Electrical Grids

AMERICAN MADE X SERIES LED SOLAR LIGHTING SYSTEM: X-3640-LED-185-T

SOLAR ENERGY KIT MODEL: SISMA-CS3500

Where. Where there s sun. there s SUNGEN.

Magellan Utility Scale Energy Storage

A Electric Power / Controls ELECTRIC POWER TECHNOLOGY 0.2 kw

SAMPLE PERMIT APPLICATION PACKAGE

LOT Kwp Solar PV Power Solution with Battery Backup

Armature Reaction and Saturation Effect

RNG Mono. Monocrystalline Type 10/20/30/50/60/100/150/250W. Key Features High module conversion efficiency. Application. Linear Warranty.

Photovoltaic System Overcurrent Protection

A Electric Power / Controls SMART GRID TECHNOLOGIES 0.2 kw

KIT-STCS60D KIT-STCS100D Solar Suitcase 60W and 100W Owner s Manual

14th Edition MECHANICAL SECTIONS TRAINING EQUIPMENT

Total array surface conformity with European. (average) parameters are measured:

INDEX. 3 BOREHOLE DC SOLAR PUMPS 3LLS...4 PERIPHERAL VANE DC SOLAR PUMP 3LSQB2...6

CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable

3400W Solar Battery Charger Maximum Power Point Tracker

SOLAR ENERGY KIT MODEL: SEM-CS3000

Iowa State University Electrical and Computer Engineering. E E 452. Electric Machines and Power Electronic Drives

Integrated Laboratory for Electrical Machines LIMEL

Experiment 4 Topic: Solar Panel Week B Procedure

SUN Series Grid Tie Power Inverter

Transcription:

Photovoltaic Solar Energy Modular Trainers Technical Teaching Equipment Products Products range Units 5.-Energy MINI-EESF. Photovoltaic Solar Energy Modular Trainer (Complete) MINI-EESF/M. Photovoltaic Solar Energy Modular Trainer (Intermediate) MINI-EESF/B. Photovoltaic Solar Energy Modular Trainer (Basic) GENERAL DESCRIPTION Photovoltaic Solar Energy Modular Trainer "MINI-EESF" is a laboratory scaled unit designed to study all the parameters involved in the solar radiation direct conversion into electricity. The trainer is based on some application modules and photovoltaic solar panels assembled in mobile structures. It is specially designed for the theoretical and practical study of the electrical installations with photovoltaic solar energy, the typical configurations used in photovoltaic installations and the operation of the different elements involved in the conversion. The power obtained from the solar energy can be: Regulated to obtain a DC power to charge a battery, studying parameters such as solar module s current output charge level, battery voltage, etc. Delivered to DC loads, studying parameters such as solar module s current output and current consumption by the loads. Converted to AC power to be delivered to AC loads, studying parameters such as current consumption by the loads. Injected to the grid, studying parameters such as simulated solar module s current and voltage outputs, power injected to the grid, mains voltage and frequency, etc. Three different versions are available with different practical possibilities and levels of difficulty: MINI-EESF, MINI-EESF/M and MINI-EESF/B. ISO 9000: Quality Management (for Design, Manufacturing, Commercialization and After-sales service) European Union Certificate (total safety) Page 1 Certificates ISO 14000 and ECO-Management and Audit Scheme (environmental management) Worlddidac Member Worlddidac Quality Charter Certificate (Worlddidac Member)

Photovoltaic Solar Energy Modular Trainer (Complete) MINI-EESF N-ES20. Module N-ES90. Module N-ES30. Module N-ES10. Module N-ES50. Module N-ES40. Module N-ES80. Module Photovoltaic module EE-KIT2. Grid Connection Inverter Kit SPECIFICATIONS Main features: Supply and Consumption at 12 V (DC). Supply and Consumption in alternating current (AC). Supply to the network (grid). Solar Panel (polycrystalline) mounted on an anodized aluminum structure with wheels for mobility, and with calibrated cell to measure solar irradiation. It consists of 36 high performance photovoltaic cells (35 x 55 mm), with a typical power of 50Wp for a 17Vdc voltage. Both the protections and the used materials give it water proof properties, abrasion protection, hail impact protection and several other adverse environmental factors protection. Technical data: Maximum nominal power: 66W. Voltage at maximum power point (Vmpp): 17.8 V. Current at maximum power point (Impp): 3.70 A. Short-circuit current (Isc): 4.05 A. Open circuit voltage (Voc): 22.25 V. Dimensions: 660 x 35.5 x 780 mm. Weight: 3 Kg. approx. Battery offering optimal performance with low power applications. Set of interconnection cables. Rack for modules allocation: Modules: N-ES10. Solar charge controller with an automatic recognition for operating voltage 12 V or 24 V. It monitors several parameters such as voltage, current and charge level of the battery, load current, status, etc. Additional functions can be activated such as the settings, night light function and auto-test. The regulator is equipped with various devices to protect its electronics, battery and load. N-ES20. Loads module that incorporates two 12 V, 20W lamps, with independent switches. N-ES30. DC/AC inverter that outputs a sinewave shaped output of 230V/50Hz ± 2% and the nominal input voltage is 12Vdc. Two different operating modes: continuous mode and ASB mode (Auto Standby) to reduce the power consumption. It is provided with a diagnosis system to indicate the user the status by different flash sequences. continue... Page 2

Specifications (continuation) N-ES40. AC Voltage measurements module until 250V. and DC until 250 V. (digital multimeter). N-ES50. Loads module that incorporates two lamps of 220V., 50 W., with independent switches. 2 N-ES80. Module for measurements of solar irradiation (W/m ) and measurements of current until 10 A., with digital multimeter. N-ES90. Module for 12Vdc battery charger. EE-KIT2. Grid Connection Inverter Kit. Inverter used for the conversion and injection to the grid of the power generated by a simulated source of renewable energy. The simulated source is a simulator used to obtain a variable power to be injected to the grid. The operation mode is displayed by means of an indicating LED at the front side of the housing. It is equipped with extensive safety measures to ensure that it is immediately switched off as soon as the AC plug is removed from the wall socket or the operation of the public grid fails. The inverter can be connected to a computer (PC) through a RS232/USB communication to display some parameters, such as voltage and current inputs, mains voltage and frequency, maximum AC power, Kwh, etc. - Grid Connection Inverter: Input (DC): Nominal power @ 25ºC: 150 W. Maximum power @ 25ºC: 220 W. MPP voltage: 45-125V DC. Maximum voltage: 155V DC. Nominal current: 3A. Output (AC): Voltage: 230V (207-253 V). Maximum power, fuse: 2A. Frequency: 50 Hz (49.8 ~ 50.2 Hz). This unit is supplied with the Grid Simulator (ESR), which simulates a low power grid to inject the power generated by the inverter. - Grid Simulator (ESR): ESR is designed to create an isolated low power grid. The unit uses a battery as voltage source and generates a sine signal of 220V/50Hz. The main features of the ESR are: Inlet voltage source: battery of 12Vdc. Output: 220V/50Hz. Isolation transformer. Battery charger included. Protection fuses. The user can work with this module safely. The devices included in the EE-KIT2 can be used worldwide. Cables and Accessories, for normal operation. Manuals: This unit is supplied with the following manuals: Required Services, Assembly and Installation, Starting-up, Safety, Maintenance & Practices Manuals. EXERCISES AND PRACTICAL POSSIBILITIES Some Practical Possibilities of the Unit: 1.- Determination of the constituent material of the solar cell. 7.- Solar energy measurement. 2.- Determination of the I-V first quadrant curve without illuminating 8.- Measurement of the solar panel voltage with no load. the solar cell. 9.- Determination of the disposition of cells in a solar panel. 3.- Determination of the inverse (or saturation) current of the cell 10.- Familiarisation with the regulator parameters. 11.- Loads connection to 12 Volts DC. 4.- Determination of parallel and series resistance of a solar cell 12.- Loads connection to 220 Volts AC. 5.- Dependency of the open circuit voltage (V oc) with lumens 13.- Study of the grid utility inverter. (luminous flux). 14.- Battery charging. 6.- Determination of the parameters that describe the quality of a solar cell. DIMENSIONS & WEIGHTS MINI-EESF: Rack with modules: Dimensions: 645 x 325 x 925 mm. approx. (25.39 x 12.79 x 36.41 inches approx.) Dimensions: 730 x 510 x 1150 mm. approx. (28.74 x 20.07 x 45.27 inches approx.) Grid Connection Inverter Kit: Dimensions: 550 x 410 x 820 mm. approx. (21.65 x 16.14 x 32.28 inches approx.) Weight: 30 Kg. approx. (66.13 pounds approx.) Specifications subject to change without previous notice, due to the convenience of improvements of the product. * Page 3

Photovoltaic Solar Energy Modular Trainer (Intermediate) MINI-EESF/M N-ES90. Module N-ES30. Module N-ES10. Module N-ES20. Module N-ES40. Module N-ES50. Module N-ES80. Module Photovoltaic module SPECIFICATIONS Main features: Supply and Consumption at 12 V (DC). Supply and Consumption in alternating current (AC). Solar Panel (polycrystalline) mounted on an anodized aluminum structure with wheels for mobility, and with calibrated cell to measure solar irradiation. It consists of 36 high performance photovoltaic cells (35 x 55 mm), with a typical power of 50Wp for a 17Vdc voltage. Both the protections and the used materials give it water proof properties, abrasion protection, hail impact protection and several other adverse environmental factors protection. Technical data: Maximum nominal power: 66W. Voltage at maximum power point (Vmpp): 17.8 V. Current at maximum power point (Impp): 3.70 A. Short-circuit current (Isc): 4.05 A. Open circuit voltage (Voc): 22.25 V. Dimensions: 660 x 35.5 x 780 mm. Weight: 3 Kg. approx. Battery offering optimal performance with low power applications. Set of interconnection cables. Rack for modules allocation: Modules: N-ES10. Solar charge controller with an automatic recognition for operating voltage 12 V or 24 V. It monitors several parameters such as voltage, current and charge level of the battery, load current, status, etc. Additional functions can be activated such as the settings, night light function and auto-test. The regulator is equipped with various devices to protect its electronics, battery and load. N-ES20. Loads module that incorporates two 12 V, 20W lamps, with independent switches. N-ES30. DC/AC inverter that outputs a sinewave shaped output of 230V/50Hz ± 2% and the nominal input voltage is 12Vdc. Two different operating modes: continuous mode and ASB mode (Auto Standby) to reduce the power consumption. It is provided with a diagnosis system to indicate the user the status by different flash sequences. N-ES40. AC Voltage measurements module until 250V. and DC until 250 V. (digital multimeter). N-ES50. Loads module that incorporates two lamps of 220V., 50 W., with independent switches. 2 N-ES80. Module for measurements of solar irradiation (W/m ) and measurements of current until 10 A., with digital multimeter. N-ES90. Module for 12Vdc battery charger. Cables and Accessories, for normal operation. Manuals: This unit is supplied with the following manuals: Required Services, Assembly and Installation, Starting-up, Safety, Maintenance & Practices Manuals. Page 4

Some Practical Possibilities of the Unit: EXERCISES AND PRACTICAL POSSIBILITIES 1.- Determination of the constituent material of the solar cell. 2.- Determination of the I-V first quadrant curve without illuminating the solar cell. 3.- Determination of the inverse (or saturation) current of the cell 4.- Determination of parallel and series resistance of a solar cell 5.- Dependency of the open circuit voltage (V oc) with lumens (luminous flux). 6.- Determination of the parameters that describe the quality of a solar cell. 7.- Solar energy measurement. 8.- Measurement of the solar panel voltage with no load. 9.- Determination of the disposition of cells in a solar panel. 10.- Familiarisation with the regulator parameters. 11.- Loads connection to 12 Volts DC. 12.- Loads connection to 220 Volts AC. 13.- Battery charging. MINI-EESF/M: Rack with modules: DIMENSIONS & WEIGHTS Dimensions: 645 x 325 x 925 mm. approx. (25.39 x 12.79 x 36.41 inches approx.) Dimensions: 730 x 510 x 1150 mm. approx. (28.74 x 20.07 x 45.27 inches approx.) Specifications subject to change without previous notice, due to the convenience of improvements of the product. * Page 5

Photovoltaic Solar Energy Modular Trainer (Basic) MINI-EESF/B N-ES10. Module N-ES20. Module N-ES90. Module N-ES80. Module Photovoltaic module SPECIFICATIONS Main features: Supply and Consumption at 12 V (DC). Solar Panel (polycrystalline) mounted on an anodized aluminum structure with wheels for mobility, and with calibrated cell to measure solar irradiation. It consists of 36 high performance photovoltaic cells (35 x 55 mm), with a typical power of 50Wp for a 17Vdc voltage. Both the protections and the used materials give it water proof properties, abrasion protection, hail impact protection and several other adverse environmental factors protection. Technical data: Maximum nominal power: 66W. Voltage at maximum power point (Vmpp): 17.8 V. Current at maximum power point (Impp): 3.70 A. Short-circuit current (Isc): 4.05 A. Open circuit voltage (Voc): 22.25 V. Dimensions: 660 x 35.5 x 780 mm. Weight: 3 Kg. approx. Battery offering optimal performance with low power applications. Set of interconnection cables. Rack for modules allocation: Modules: N-ES10. Solar charge controller with an automatic recognition for operating voltage 12 V or 24 V. It monitors several parameters such as voltage, current and charge level of the battery, load current, status, etc. Additional functions can be activated such as the settings, night light function and auto-test. The regulator is equipped with various devices to protect its electronics, battery and load. N-ES20. Loads module that incorporates two 12 V, 20W lamps, with independent switches. 2 N-ES80. Module for measurements of solar irradiation (W/m ) and measurements of current until 10 A., with digital multimeter. N-ES90. Module for 12Vdc battery charger. Cables and Accessories, for normal operation. Manuals: This unit is supplied with the following manuals: Required Services, Assembly and Installation, Starting-up, Safety, Maintenance & Practices Manuals. Page 6

Some Practical Possibilities of the Unit: EXERCISES AND PRACTICAL POSSIBILITIES 1.- Determination of the constituent material of the solar cell. 2.- Determination of the I-V first quadrant curve without illuminating the solar cell. 3.- Determination of the inverse (or saturation) current of the cell 4.- Determination of parallel and series resistance of a solar cell 8.- Measurement of the solar panel voltage with no load. 9.- Determination of the disposition of cells in a solar panel. 10.- Familiarisation with the regulator parameters. 11.- Loads connection to 12 Volts DC. 12.- Battery charging. 5.- Dependency of the open circuit voltage (V ) with lumens oc (luminous flux). 6.- Determination of the parameters that describe the quality of a solar cell. 7.- Solar energy measurement. MINI-EESF/B: Rack with modules: DIMENSIONS & WEIGHTS Dimensions: 645 x 325 x 670mm. approx. (25.39 x 12.79 x 26.37 inches approx.) Weight:6 Kg. approx. ( 13.22 pounds approx.) Dimensions: 730 x 510 x 1150 mm. approx. (28.74 x 20.07 x 45.27 inches approx.) Specifications subject to change without previous notice, due to the convenience of improvements of the product. * - PSA/PC. Polycrystalline photovoltaic solar panel. OPTIONAL ELEMENTS - PSA/MC. Monocrystalline photovoltaic solar panel. - PSA/AM. Amorphous photovoltaic solar panel. Page 7

Optional MINI-EESF/CAI. Computer Aided Instruction Software System: Trainer Instructor Software + Student Software With no physical connection between trainer and computer (PC), this complete software package consists of an Instructor Software (INS/SOF) totally integrated with the Student Software (MINI- EESF/SOF). Both are interconnected so that the teacher knows at any moment what is the theoretical and practical knowledge of the students. INS/SOF. Classroom Management Software (Instructor Software): Example of software screens Instructor Software The instructor can: Organize Students by Classes and Groups. Create easily new entries or delete them. Create data bases with student information. Analyze results and make statistical comparisons. Generate and print reports. Detect student s progress and difficulties....and many other facilities. This software working in network configuration allows controlling all the students in the classroom. MINI-EESF/SOF. Computer Aided Instruction Software (Student Software): Student Software It explains how to use the trainer, run the experiments and what to do at any moment. This Software contains: Theory: gives the student the theoretical background for a total understanding of the studied subject. Exercises: divided by thematic areas and chapters to check out that the theory has been understood. Guided Practices: presents several practices to be done with the trainer, showing how to complete exercises and practices. Exams: set of questions to test the obtained knowledge. For more information see CAI catalogue. Click on the following link: /products/catalogues/en/cai.pdf Page 8

Optional MINI-EESF/CAL. Computer Aided Learning Software (Results Calculation and Analysis): This Computer Aided Learning Software (Results Calculation and Analysis) CAL is a Windows based software, simple and very easy to use, specifically developed by EDIBON. CAL is a class assistant that helps in doing the necessary calculations to extract the right conclusions from data obtained during the experimental practices. With a single click, CAL computes the value of all the variables involved and performs the calculations. Also, CAL allows to plot and print the results. Within the plotting options, any variable can be represented against any other. Available different plotting displays. It has a wide range of information, such as constant values, unit conversion factors and integral and derivative tables. On a table, we introduce data obtained during the development of the exercise. Above this table, it is shown Constants theoretically involved with the field of study. The values of these Constants may be modified to our convenience, assigning the appropriate values. Simply, by clicking on "COMPUTE", CAL performs the calculations of the desired variables. We can save and print the data of the experiment or calculations. Also we can load any data file saved previously. With the calculated variables, CAL gives the option of plotting the results. It is possible to represent any variable against any other. It has the option of representing the graph with different layouts. Screens below give an example of the multiple choices. CAL has a wide range of help information. By clicking the button "ADDITIONAL HELP" opens a window where we have information about typical Constants, International System Units, Conversion Factors, and Table of Main Integrals and Derivatives (General), and there is other specific help for the particular unit. For more information see CAL catalogue. Click on the following link: /products/catalogues/en/cal.pdf Specifications subject to change without previous notice, due to the convenience of improvements of the product. * REPRESENTATIVE: C/ Del Agua, 14. Polígono Industrial San José de Valderas. 28918 LEGANÉS. (Madrid). SPAIN. Phone: 34-91-6199363 FAX: 34-91-6198647 E-mail: edibon@edibon.com WEB site: Issue: ED02/14 Date: May/2014 Page 9