CANADIAN BROCHURE Enclosed Circuit Breakers Tmax Range

Similar documents
Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

S4 N 250 B W - 2 xxx. Isomax. Isomax Molded case circuit breakers S3 S8. MCCBs

Miniature Circuit Breakers

Application guide. Tmax Link OEM UL 891 Switchboard Program

Engine Generator Circuit Breakers

US Brochure. Tmax XT Molded case circuit breakers Simply XTraordinary

Tmax Molded Case Circuit Breakers

Tmax Molded Case Circuit Breakers

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Lighting and Power Distribution Panelboards

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

S4 N 250 B W - 2 xxx. Isomax MCCBs. Isomax Molded case circuit breakers S1 S8

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Bussmann series Quik-Spec Power Module Switch elevator disconnect

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

5.2. Power Pedestals. Contents Description

Bulletin 190-M Compact Starters. Selection Guide

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches. Ex9 Series - M. na.noark-electric.

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

C E R T I F I C A T E O F C O M P L I A N C E

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Detail Bill of Material Page 1 of 2 Project Name: Arc Eng Exposition Negotiation No: LAEC0706X6K1 General Order

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Design Standard. Purpose: Design Standard:

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

Breakers and Switches. Tmax XT Moulded-case circuit-breakers Simply extraordinary

Series L9 UL-489 Miniature Circuit Breakers

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Quik-Spec Electrical Gear

Laser Service Factory-assembled Panelboards

6.2. Power Pedestals. Contents

Extract of the technical catalogue SACE Tmax XT New low voltage molded-case circuit breakers up to 250A

SECTION PANELBOARDS

Ordering information for XT1, XT2, XT3, XT4 UL/CSA Accessories

Quick Connection Panel (QCP) Installation Guide

VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M

SACE Tmax XT. New low voltage moulded-case circuit-breakers up to 250A.

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Bussmann series Quik-Spec Coordination Panelboard

Disconnect switches Non-fusible Fusible Enclosed

Preliminary - 1SDC210003B0201. New Tmax T4-T5. T Generation.

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers

Enclosures. See Section Typical Description

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Product Specification Sheet #3LD2.1

Bulletin 140U R-Frame Molded Case Circuit Breakers

Thermal-Magnetic For Mining Applications Class 600

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

PRODUCT BROCHURE Microlectric Highly corrosion-resistant meter sockets for harsh environments

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Selection Guide Motor Control Device Solutions

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

2.3. Molded Case Circuit Breakers. Contents. Internal Accessories. Series C. Product Overview. Description

Molded Case Circuit Breakers

Uninterruptible Power Supplies

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

Generator Quick Connection Tap Box WM Series

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C

C E R T I F I C A T E O F C O M P L I A N C E

Selection Guide. Control Circuit and Load Protection

Preliminary AC1615S. ABB Molded Case Circuit Breakers

Molded Case Circuit Breakers

S200-C, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2

Product Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers

D509E. Manual Motor - Starters

BULLETIN 140U. Molded Case Circuit Breakers SELECTION GUIDE

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

Control Circuit Protection

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

2.3. Molded Case Circuit Breakers. Series C. Accessories Selection Guide and Ordering Information

Understanding National Electric Code (NEC) tap rules How do they apply to circuit breaker terminals?

Motor Circuit Breakers C4

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

MS General Information Extended Product Type: MS

Contents. 4 Loadcentres

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

L-Frame. With Standard Line and. Standard Terminals Only. Catalog Number. Price U.S. $ LDB2300 LDB2350 LDB2400 LDB2450 LDB2500 LDB2600

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Selection & Application Guide. BFT Main Feed Thru Modules. Power Mod. usa.siemens.com/powermod

VL Circuit Breaker DG 150A frame

Transcription:

CANADIAN BROCHURE 2017 Tmax Range

5 ENCLOSED CIRCUIT BREAKERS - CANADIAN BROCHURE Reliable solution ABB solution for enclosed circuit breaker ABB s enclosed circuit breakers offer all the advantages and accessories of a circuit breaker packaged in an enclosure for nearly any application requiring a means of disconnect. Ideal for a variety of locations including general purpose, rainproof surface mounting, water and dustproof. 100% rated products are available in configurations ranging from 15 to 1200 A to meet the needs of many applications. With the possibility of having a service entrance rating, the offering is complete for all industrial, commercial and heavy residential applications. Moreover, the new range of Tmax XT is now included with the enclosed solution. Offering the most up-to-date technology on the market related to circuit protection. The new Ekip protection unit can be added to the breaker for increased reliability, safety and durability. Factory assembled units are proudly assembled in Canada.

ENCLOSED CIRCUIT BREAKERS - CANADIAN BROCHURE 2 Features & Benefits Confidence and flexibility The enclosed Tmax circuit breaker solution from ABB offers a wide variety of solutions for all your needs. Rest assured that all products are certified according to local regulations. Available with the new Tmax XT up to 250A and with standard Tmax solution from 400A up to 1200A 01 New Tmax XT range 02 CSA certified Latest circuit breaker technology are now offered with the new Tmax XT range which offers more flexibility and precision (thanks to the new Ekip trip unit offering). Certification ABB enclosed Tmax circuit breaker solution is CSA and UL certified as standard on Type 1 enclosures and factory certified on special assemblies using other s of enclosures such as 3, 3R, 4, 4X and 12. Standard Type 1 enclosure All standard are assembled with certified NEMA 1 enclosures with padlocking possibility. Other NEMA rated enclosures are available on request. Service entrance Certified Service entrance assembly is available and performed at our factory conformed to the Canadian Electrical code by the CSA group. Options flexibility ABB offers the choice of factory assembled units or DYI solution. DYI solution is the possibility to purchase loose components to build your own assembly. Service Entrance solution is not available with DYI. Factory assembled standard is the assembly of a non Service Entrance unit according to customer s requirement Factory assembled Service Entrance is the assembly of Service Entrance rated units. Only available through our factory with proper certification. Assembled according to customer s requirement.. 01 02

ENCLOSED CIRCUIT BREAKERS - CANADIAN BROCHURE 3 DYI configuration & selection DIY configuration (loose parts) The DYI configuration does not include the circuit breaker. It must be selected according to our technical catalog 1SXP210003C0201. All electrical work shall be performed by qualified personel and conform to all applicable saftey codes. Service Entrance rating not available on DYI configuration. Standard Type 1 s on DYI configuration. DYI solution for Type 1 enclosures Amperage max. part number approx. dimensions H x W x D (in) part number amperage max. wire range XT1 125 A EB1-XT1-125 16 x 12 x 5 XT2 125 A EB1-XT2-125 16 x 12 x 5 XT3 125 A EB1-XT3-125 16 x 12 x 5 225 A EB1-XT3-225 26 x 12 x 5 100 A EB1-XT4-100 16 x 12 x 5 225...250 A (1) EB1-XT4-225 26 x 12 x 5 XT4 SNT4-250 250 A 6 AWG... 350 kcmil 250 A EB1-XT4-250 36 x 20 x 5 SNT4-250 250 A 6 AWG... 350 kcmil T5 300...400 A EB1-T5-400 36 x 20 x 5 SNT5-300 300 A 250 kcmil... 500 kcmil SNT5-400 400 A 2x 3/0... 2x 250 kcmil T6 600...800 A EB1-T6-800 48 x 22 x 6.15 SNT6-600 600 A 2x 250 kcmil... 2x 500 kcmil SNT6-800 800 A 4x 250 kcmil... 4x 500 kcmil T7 1200 A EB1-T7-1200 48 x 22 x 6.15 SNT7-1200 1200 A 4x 250 kcmil... 4x 500 kcmil (1) 250 A with Cu cable (300 kcmil max)

ENCLOSED CIRCUIT BREAKERS - CANADIAN BROCHURE 4 Factory assembled configuration Catalog number explanation EB1 - XT3 HQ 225 T L N - 01 IC class Current rating Trip unit Lugs requirement Options (1) Factory assembled solution Interrupting rating class (2) Current rating (2) Trip unit Lugs requirement Neutral bar (2) kit (3) EB1 Type 1 XT1 125 A max B Basic 015 15 A T Thermal-magnetic Blank No lugs supplied Blank No neutral EB2 Type 12 XT2 125 A max. BQ Basic 100% 020 20 A B Elect. LS/I L Lugs supplied N With neutral EB3 Type 3R XT3 225 A max. N Normal 025 25 A C Elect. LSI EB4 Type 4 XT4 250 A max. NQ Normal 100% 030 30 A E Elect. LSIG EBX Type 4X T5 400 A max. S Standard 035 35 A P Adv. Elect. LI EBP Type 4X T6 800 A max. SQ Standard 100% 040 40 A R Adv. Elect. LSI Plastic T7 1200 A max. H High 050 50 A S Adv. Elect. LSIG HQ High 100% 060 60 A L Extra High 070 70 A LQ Extra High 100 % 080 80 A V Very High 090 90 A VQ Very High 100% 100 100 A 125 125 A 150 150 A 175 175 A 200 200 A 225 225 A 250 250 A 300 300 A 400 400 A 600 600 A 800 800 A 1000 1000 A 1200 1200 A (1) Please consult ABB for additional options such as auxiliary contacts, shunt trips, bell alarm. Sequential number provided by ABB (2) Always consult our technical catalog 1SXP210003C0207 to determine the correct IC class and amperage values assigned to each circuit breaker (3) Neutral bar kit required for service entrance rated enclosed circuit breaker. Consult ABB if service entrance is required.