Self-consumption solutions

Similar documents
Solutions for Self-consumption

Electric Switchboards

CIRCUTOR s Energy Management System

New range of reclosing systems

Smart equipment and Systems for electric vehicle charging

PowerRouter Solar Battery Self-use

Solutions for Electrical energy efficiency

Operation of a CDP in SPLIT-PHASE installations

Automatic capacitor banks

ABB central inverters ULTRA-750/1100/ kW to 1560kW

Schneider Electric Conext SW

/ The personal storage solution for 24H sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

Solar inverter AX-series

THREE-PHASE. FRONIUS ENERGY PACKAGE / The personal storage solution for 24 hours of sun. EFFICIENT FLEXIBLE REVOLUTIONARY

IMEON 9.12 USER MANUAL

Your home and business energy independance. Energy Bundle CA5000TPV-3D

Sunny Tripower CORE1.

THE SELF USE SMART GRID INVERTER NEW GENERATION

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

* Protected from tools and particles greater than 2.5 millimeters * Protected form low pressure water jets from any direction

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS 1.2 to 5.0 kw

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS-Q 1.2 to 5.0 kw

Residential Energy Storage System SH5K PV ESS

Residential Energy Storage System SH 5K

Photovoltaics. MPI Hybrid Series

1 EASY COMMISSIONING GUIDE FRONIUS PV-SYSTEM CONTROLLER

StorEdge Solar and Energy Storage System Review

FRONIUS ENERGY PACKAGE

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

Guidelines for the Design of Residential and Community Level Storage Systems Combined with Photovoltaics (PV)

Off-Grid solutions. solutions for rural electrification. swiss made power

off-grid Solutions Security of supply Basics: Off-grid energy supply

Distribution division. Solar Photovoltaic Catalogue. Premier Plaan. Smart solutions for the solar energy sector around the world

Green approach to fuel savings

FRONIUS SNAPINVERTERS SMARTER, LIGHTER, MORE FLEXIBLE. / Perfect Welding / Solar Energy / Perfect Charging

Store your own energy

OFF GRID PV POWER SYSTEMS SYSTEM DESIGN GUIDELINES FOR THE PACIFIC ISLANDS

THREE-PHASE FRONIUS ENERGY PACKAGE. EFFICIENT / High-performance lithium iron phosphate

Using Inverter Input Modes for Smart Grid Management

FRONIUS SNAPINVERTERS SMARTER, LIGHTER, MORE FLEXIBLE. / Perfect Welding / Solar Energy / Perfect Charging

SOLAR ENERGY KIT MODEL: SEM-CS3000

Smart Energy Control With the use of new technologies

DEGERtracker 3000HD / 3000NT / 5000NT Long-term power supplier. DEGERtracker - Dual-axis tracking system

Technical and Economic Assessment of Solar Photovoltaic and Energy Storage Options for Zero Energy Residential Buildings

Pika Energy Island Made in America

Using Inverter Input Modes for Smart Grid Management

SolarMax MT series. The power pack for maximum yields.

Smart earth leakage protection

SMART 1000 / 2000 SERIES

Demonstration PV rural microgrids project in Chad (Central Africa)

Microgrids Outback Power Technologies

Safe, reliable, long lasting Lithium Iron Phosphate battery. Next generation capture and release technology. Increased efficiency for greater savings

ABB central inverters PVS to 1000 kw

Power Conversion System The Best Technology for your photovoltaic and storage system

24 HOURS OF SUN IS POSSIBLE. NOW THAT RENEWABLE ENERGY IS ACCESSIBLE ALL AROUND THE CLOCK. / Solar Energy Services and product programme 2014/15

Designing Stand Alone Systems. Overview, components and function, Elements in Design

SolarMax MT series The all-rounder for trade and industry

RPS TL-UL System. Solutions for the North American Solar Market

ABB string inverters PVI-3.0/3.6/4.2-TL-OUTD 3 to 4.2 kw

Safe, reliable, long lasting Lithium Iron Phosphate battery. Next generation capture and release technology. Increased efficiency for greater savings

SOLON SOLiberty Energy Storage Solution. Greater Independence Through On-site Consumption.

INDEPENDENCE IS POSSIBLE. BECAUSE WE MAKE SOLAR POWER AVAILABLE DAY AND NIGHT. / Solar Energy Services and product programme 2015/16

Price list - Inverter

Implementing a Microgrid Using Standard Utility Control Equipment

SOLAR CHARGE CONTROLLERS

SOLAR ENERGY KIT MODEL: SISMA-CS3500

Current Automation Catalogue

SOLAR ENERGY KIT MODEL: SISMA-CT20000

SOL-ARK 8K. More Affordable: 5-15% less solar panels & 5-20% less batteries than others! World s Most Efficient Battery Inverter

Datasheets. Residential On-Grid Photovoltaic System Kits

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

Energy Storage System for Home

THREE-PHASE STORAGE SOLUTION EFFICIENT MODULAR REVOLUTIONARY

Delta All-In-One Storage solutions

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Energy Storage System for Home. High Efficiency - Peak efficiency 97.3% Bi-directional DC-DC converter

ABB central inverters PVS to 2000 kva

SOL-ARK 8K We guarantee it s the most effcient & affordable Multi-Mode Inverter in its class

THREE-PHASE FRONIUS ENERGY PACKAGE. EFFICIENT / High-performance lithium iron phosphate

SOLAR BATTERY SYSTEMS IMEON 3.6 3kWp SCALABLE HYBRID / OFF GRID SOLAR PV - AESTHETIC PERFORMANCE PG

STRING INVERTERS IN ROOFTOP SOLAR. Anish Wastrad Fronius India Pvt Ltd.

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

- Solar PV systems and integration - GIZ - All rights reserved

ABB central inverters PVS to 1000 kw

COMPLETE SOLUTIONS FOR POWER PROTECTION

3 Phase Power Systems - Designed for Canada

Schneider Electric PV Skid. Optimized solar power conversion system tailored to enhance any North American PV power plant

COMPANY INTRODUCTION COMPANY MISSION COMPANY VISION

A flexible and efficient residential solar solution. Conext RL single-phase grid-tie inverter

Retrofit to Single phase / Three phase PV system Micro-grid, UPS, Peak shift, Pure off-grid retrofitting etc multi-working

ABB string inverters PVI-3.8/4.6-I-OUTD 3.8 to 4.6 kw

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Mini-Grid PV Installations

AUTOMATIC CAPACITOR BANK WITH CONTACTOR OPERATIONS

SOLAR2PS 500 / 630 / 750 kw Three Phase Solar PV Inverter

Catch Eco Range : Technical Specification Sheet

Delta All in One Storage Solutions

Transcription:

TIME-DELAYED SELF-CONSUMPTION Self-consumption solutions Energy efficiency technology

Self-consumption solutions The drop in the cost of solar photovoltaic installations, coupled with the increased cost of electrical energy borne by end consumers in recent years, has accelerated the arrival of the so-called grid parity in many regions throughout the world. CIRCUTOR, by establishing synergies between knowledge of the measurement, management and improvement of the quality of electrical energy and exploiting the renewable resources that produce it, has designed solutions that integrate energy distributed in the electrical grid with instantaneous and time-delayed self-consumption applications for industrial applications, service facilities and even residential buildings A solution adapted to each need Each consumer has a different demand curve, as well as specific situation in terms of access to the grid. To this end, CIRCUTOR has designed different solutions that adapt to each situation, offering optimum management of solar resources, optimising efficiency, simplifying management processes and achieving the highest possible cost savings. The solutions offered fall into two categories, based on the time relationship established between solar production and the consumption of electricity in each case: yinstantaneous or direct selfconsumption, without storage ytime-delayed self-consumption with storage yinstallations isolated from the grid yinstallations with DC coupling to the grid yinstallations with AC coupling to the grid

Instantaneous self-consumption with control over the energy injected into the grid Ideal for buildings with significant daytime electricity consumption. CDP (Dynamic Power Control) controllers adjust the maximum production power of photovoltaic inverters to that being consumed in the building at all times. Therefore, we can guarantee that, for example, surplus energy is not injected into the grid or that the power fraction allowed by the specific laws of each country is injected into the grid. In many countries, this type of installation allows the use of the photovoltaic system as an inherent element of the building's internal electrical network, becoming an energy saving element and not an energy generation system that requires the capacity to discharge energy into the grid to which it is connected. Time-delayed self-consumption with energy storage It is necessary in buildings where the main consumption of electricity is during night-time or low solar radiation hours. Installations isolated from the electrical network It can supply energy to places that do not have good access to the electrical distribution lines, catering for the energy needs of different consumption types (residential, agriculture, tourism, etc.) The solutions isolated from the grid offer high quality electric supply for any common use of energy, such as lighting, household appliances, power units, etc., both in single and three-phase applications. Hybrid solar-diesel generation can improve the performance of the installation and minimise the use of the support generating set, depending on the consumption features and intelligent management of storage and demand. Installations with DC coupling to the grid Buildings connected to the grid can improve their degree of solar self-supply by installing a battery between the building and grid that stores surplus energy during periods of high insolation for its future consumption. In these systems, controlling the battery charge plays a crucial role, since it manages the flows of energy between all elements in an installation. Therefore, the system can self-consume energy directly during the day, storing daytime surplus energy in the battery and, finally, reduce the consumption of grid energy during periods of low insolation by discharging the battery. Instantaneous self-consumption with control over the energy injected into the grid Installations with AC coupling to the grid Buildings connected to the grid that already have a photovoltaic generation system installed can transfer part of the solar energy production for its consumption during periods of low insolation. In these systems, controlling the battery charge can reduce or even eliminate surplus daytime energy transferred to the grid and reduce the power peaks required by the grid by injecting the power stored in the storage system. Instantaneous self-consumption with control over the energy injected into the grid

INSTANTANEOUS SELF-CONSUMPTION Instantaneous self-consumption with zero injection Kits for installations connected to the grid CDP-0 CVM MINI MC3 RS-485 Inverter Reverse current relay MC3 CVM MINI Description CIRCUTOR's photovoltaic kits for grid connection systems contain all the elements necessary for the instantaneous self-consumption of solar energy when it is generated, ensuring at all times that the surplueses are not injected into the grid. These kits are supplied with the following: yphotovoltaic modules yanodised aluminium structure and ties ypower Inverter for grid connection ycdp - Dynamic power control yprotection against DC and AC overvoltages Benefits of using the kits yeasy to process the order through a single code and supplier ycompatibility with all components is guaranteed yremote monitoring (via web server embedded in CDP) and historical data storage. ymeasurement of the installation's flows of energy ytop quality components ycompatibility with pre-configured cabinets (Combiner Box) that facilitate assembly. ypossibility of dimensioning the versions with the kit references for other power levels and configurations (subject to order) yoptional adaptation of the references listed to different grid typologies (international configuration, UL certification) with different frequency and voltage levels (subject to order).

INSTANTANEOUS SELF-CONSUMPTION Instantaneous self-consumption with zero injection Kits for installations connected to the grid Code Type*** Consumer Profile** PV power* Grid coupling E5K011 E5K012 E5K021 E5K022 E5K031 E5K032 E5K131 E5K132 E5K033 E5K034 E5K035 E5K036 E5K041 E5K042 E5K051 E5K052 E5K061 E5K062 E5K071 E5K072 EK5081 E5K082 CDP-1.1 CDP-1.2 CDP-2.1 CDP-2.2 CDP-3.1 CDP-3.2 CDP-3.1-3F CDP-3.2-3F CDP-3.3 CDP-3.4 CDP-3.5 CDP-3.6 CDP-4.1 CDP-4.2 CDP-5.1 CDP-5.2 CDP-6.1 CDP-6.2 CDP-7.1 CDP-7.2 CDP-8.1 CDP-8.2 Home - Basic Power Daytime stand-by power 1.5 kw Home - Basic Power Daytime stand-by power 1.5 kw Home - Basic Power Daytime stand-by power 2.5 kw Home - Basic Power Daytime stand-by power 2.5 kw Home - High Power Small-Scale Daytime stand-by power 5 kw Home - High Power Small-Scale Daytime stand-by power 5 kw Home - High Power Small-Scale Daytime stand-by power 5 kw Home - High Power Small-Scale Daytime stand-by power 5 kw Home - High Power Small-Scale Daytime stand-by power 6 kw Home - High Power Small-Scale Daytime stand-by power 6 kw Small-Scale industry Daytime stand-by power 8 kw Small-Scale industry Daytime stand-by power 8 kw Small-Scale industry Daytime stand-by power 10 kw Small-Scale industry Daytime stand-by power 10 kw Small-Scale industry Daytime stand-by power 15 kw Small-Scale industry Daytime stand-by power 15 kw Industrial Sector Daytime stand-by power 20 kw Industrial Sector Daytime stand-by power 20 kw Industrial Sector Daytime stand-by power 24 kw Industrial Sector Daytime stand-by power 24 kw Industrial Sector Daytime stand-by power 30 kw Industrial Sector Daytime stand-by power 30 kw 1,200 Wp 230 V single-phase * 1,680 Wp 230 V single-phase * 2,640 Wp 230 V single-phase * 2,880 Wp 230 V single-phase * 4,800 Wp 230 V single-phase * 5,280 Wp 230 V single-phase * Compatible with Combiner Box S-1-1-1-16-30 ; S-1-1-1-16-300 S-1-1-1-16-30 ; S-1-1-1-16-300 S-1-1-1-16-30 ; S-1-1-1-16-300 S-1-1-1-16-30 ; S-1-1-1-16-300 S-2-1-1-16-30; S-2-1-1-16-300 S-2-1-1-16-30; S-2-1-1-16-300 4,800 Wp 400 V three-phase * T-1-1-1-25-300 5,280 Wp 400 V three-phase * T-1-1-1-25-300 6,240 Wp 400 V three-phase * T-1-1-1-25-300 6,720 Wp 400 V three-phase * T-1-1-1-25-300 7,920 Wp 400 V three-phase * T-1-1-1-25-300 8,640 Wp 400 V three-phase * T-1-1-1-25-300 10,080 Wp 400 V three-phase * T-1-1-1-25-300 10,560 Wp 400 V three-phase * T-1-1-1-25-300 14,400 Wp 400 V three-phase * T-3-3-3-25-300 15,840 Wp 400 V three-phase * T-3-3-3-25-300 20,160 Wp 400 V three-phase * T-2-2-2-25-300 21,120 Wp 400 V three-phase * T-2-2-2-25-300 24,960 Wp 400 V three-phase * T-2-2-2-25-300 26,880 Wp 400 V three-phase * T-2-2-2-25-300 30,240 Wp 400 V three-phase * T-3-3-3-25-300 31,680 Wp 400 V three-phase * T-3-3-3-25-300 * The units that make up the kits are sized according to the following conditions: Available radiation of 4.75 kwh/m² (centre of the Iberian peninsula). Solar generator with optimum orientation (0 south) and tilt (35 ). ** The performance of the units and expected annual energy production is subject to adapting each kit to the established consumer profile. *** The listing and description of the individual devices that make up the photovoltaic kits, their features and manufacturer will only be indicated upon confirming their order.

INSTANTANEOUS OR TIME-DELAYED SELF-CONSUMPTION Instantaneous or time-delayed self-consumption with zero injection Kits for solar canopies CDP-0 Electric Vehicle Recharge CVM MINI MC3 RS-485 Inverter Reverse current relay MC3 CVM MINI Screenshot: real application of a solar canopy. + information in real time https://efm-pvcar.circutorenergy.com Description Solar canopies are built with a solid machined, welded and galvanised steel structure that can integrate the photovoltaic generation field by optimising the use of the terrain, guaranteeing the safety of the installation and achieving an appealing design. The energy supplied by the solar photovoltaic generator installed on the canopy can be combined for different energy uses: Instantaneous self-consumption connected to the network inside the building. Self-consumption isolated from the grid with the power supply provided by a battery charging system. Power supply for any of the electric vehicle charging systems with the use of one of CIRCUTOR's smart charging stations. Benefits of using the kits Generation of solar energy in places where there is no roof or free surface to install solar modules Mitigation of peak consumption effects in vehicle charging systems Remote monitoring (via web server embedded in CDP) and historical data storage Measurement of the installation's energy flows and optional integration with the building's energy management systems with the Power Studio Scada application Top quality components Easy to install Modular solution, easy to adapt to available parking spaces. Kits for solar canopies Code Type Type of Solar Installation Dimensions Spaces PV power Coupling E6K140 E6K220 E6K230 E6K240 E6K260 EFM-MARQ-M-4P EFM-MARQ-C-2P EFM-MARQ-C-3P EFM-MARQ-C-4P EFM-MARQ-C-6P Instantaneous selfconsumption Instantaneous selfconsumption Instantaneous selfconsumption Instantaneous selfconsumption Instantaneous selfconsumption 4 x 5 m 4 for motorcycles 1,920 Wp 230 V - Single-phase 5 x 5 m 2 3,600 Wp 230 V - Single-phase 7.5 x 5 m 3 5,040 Wp 400 V - Three-phase 10 x 5 m 4 7,200 Wp 400 V - Three-phase 15 x 5 m 6 10,800 Wp 400 V - Three-phase

Electric Vehicle charging with Wallbox INSTANTANEOUS OR TIME-DELAYED SELF-CONSUMPTION

TIME-DELAYED SELF-CONSUMPTION Time-delayed self-consumption isolated from the grid Kits for autonomous installations Demand management Inverter Main Controller RS-485 Load regulator DC/DC

TIME-DELAYED SELF-CONSUMPTION Time-delayed self-consumption isolated from the grid Kits for autonomous installations Description CIRCUTOR's photovoltaic kits for grid-isolated systems contain a set of devices necessary for the autonomous self-consumption of energy, in systems isolated from distribution lines. The kit contains the following devices: yphotovoltaic modules yanodised aluminium structure and ties ymppt load regulator (depending on the reference chosen) yinverter or dual Inverter-Loader (depending on the reference chosen) ymaintenance-free gel lead-acid battery bank ybattery temperature sensor ybii Dispenser - available daily energy dispenser yac and DC overvoltage protection Benefits of using the kits ythe photovoltaic kits and their components are included in a single order reference, generating savings in procurement logistics. yminimum maintenance of the solar installation, reliability and ease of assembly. ypossibility of remote web monitoring and historical data storage (subject to order). ypossibility of dimensioning the kit references for threephase configuration (subject to order). Kits for installations isolated from the grid with single-phase consumption Code Type*** E4K001 EFM-IS-01 Basic E4K002 EFM-IS-02 Basic E4K003 EFM-IS-03 High E4K004 EFM-IS-04 High E4K005 EFM-IS-05 Higher E4K006 EFM-IS-06 Higher Degree of electrification E4K007 EFM-IS-07 Maximum E4K008 EFM-IS-08 Maximum User profile Dwelling Occup. Weekend Dwelling Occup. Seasonal Dwelling Occup. Seasonal Dwelling Occup. Permanent Dwelling Occup. Permanent Dwelling Occup. Permanent Industrial Sector Industrial Sector Expected daily consumption** AC Inverter Power PV power* Battery* 12 V 200 Ah 12 V 475 Ah 24 V 475 Ah 24 V 575 Ah 500 Wh/day 400 W 130 Wp 1,000 Wh/day 800 W 260 Wp 2,000 Wh/day 2,000 W 520 Wp 3,500 Wh/day 3,000W 1,440 Wp 4,500 Wh/day 3,500 W 2,160 Wp 6,000 Wh/day 5,000 W 2,880 Wp 9,000 Wh/day 7,000 W 4,320 Wp 12,000 Wh/day 10,000 W 5,760 Wp 48 V 360 Ah 48 V 575 Ah 48 V 850 Ah 48 V 1130 Ah * The units that make up the kits are dimensioned according to the following conditions: Available radiation of 4.75 kwh/m² (centre of the Iberian peninsula) Units dimensioned to supply energy during months of lower solar radiation availability ** The proper functioning of the units is subject to fulfilling the stated daily consumption for each kit. *** The listing and description of the individual devices that make up the photovoltaic kits, their features and manufacturer will only be indicated upon confirming their order.

TIME-DELAYED SELF-CONSUMPTION Time-delayed self-consumption with storage. DC Coupling In general, photovoltaic systems are composed of various independent DC generation circuits, depending on the number of MPPT trackers of the inverters of the photovoltaic assembly. These circuits must be protected against overcurrents and/or overvoltages. Likewise, the connections to the AC grid for discharging each inverter must be protected against earthing faults and shortcircuits. CIRCUTOR's combiner boxes group the necessary AC and DC connection and electrical protection elements in a single cabinet, which is pre-assembled and wired at the factory. In addition to the protection elements, the range includes CDP grid injection control units, as well as the CVM-Mini auxiliary measurement and redundant protection units that disconnect the units from the power supply in the event of detecting reverse current in the grid. The range of combiner boxes has been designed to complement the range of self-consumption kits with zero injection into the grid. Self-consumption WITH storage Main controller 1 Dual Inverter 3 RS-485 4 2 CVM MINI Load regulator DC/DC EFM DC = 1 + 2 + 3 + 4 Internal elements ybidirectional inverter ycontrol and monitoring of batteries ygrid connection through transfer relay yanti-islanding control yinternet data monitoring and logging Applications yself-consumption with grid-assisted storage ypower supply of guaranteed loads ycontrol of energy cost ysupport for weak grids yinstallations isolated from the grid ISTG. Dual inverter for self consumption with storage

TIME-DELAYED SELF-CONSUMPTION Time-delayed self-consumption with storage. AC Coupling This solution is especially suitable for those buildings that already have a grid-connected photovoltaic installation for energy sales for which you wish to divert part of the production to be consumed when solar radiation decreases. In these systems, the supervisor modulates the invertercharger with the aim of minimising energy exchange with the grid. It charges the battery based on the surplus in daytime hours and discharges the battery based on consumption in hours of low or zero insolation. Self-consumption WITH storage 1 Main controller RS-485 2 3 CVM MINI Dual inverter Inverter EFM AC = 1 + 2 + 3 Internal elements ybidirectional inverter ycontrol and monitoring of batteries ygrid connection through transfer relay yanti-islanding control yinternet data monitoring and logging Applications yself-consumption with grid-assisted storage ypower supply of guaranteed loads ycontrol of energy cost ysupport for weak grids yinstallations isolated from the grid

COMBINER BOX Combiner Box for protecting and managing solar installations Description Photovoltaic systems are composed of various separate DC circuits that must be combined in a single circuit before DC is transformed into AC, in order to use this AC power and inject it into the electrical network or use it for internal consumption of a dwelling or building. The Combiner boxes are used for such purposes. These connection cabinets group the different strings connected to the photovoltaic panels. CIRCUTOR's combiner boxes group all DC and AC electrical protection elements required, so that the user can have everything in a single cabinet. In addition to the protection elements, the products of the range come with a CDP-0, which guarantees that the user can manage zero injection into the electrical network, as well as a CVM-MINI power analyzer for measuring the electrical consumption. The combiner boxes feature a web server, through which the user can connect to monitor both the installation's consumption and generation of electricity. The range of combiner boxes has been designed to complement the range of self-consumption kits with zero injection to the grid.

COMBINER BOX Combiner Box for protecting and managing solar installations About the kits 1 2 3 4 5 6 Fuses with removable DC fuse carrier. CVM power analyzers. AC Electrical protection for inverters. CDP - Dynamic power control. AC and DC overvoltage protection. Reverse current protection relay. Combiner Box Models Type S-1-1-1-16-30 S-1-1-1-16-300 S-2-1-1-25-30 S-2-1-1-25-300 T-1-1-1-25-300 T-2-2-2-25-300 T-3-3-3-25-300 Code E53112 E53117 E53214 E53219 E53419 E53529 E53639 E53339 Compatible Kits CDP 1.1, 1.2, 2.1, 2.2 CDP 1.1, 1.2, 2.1, 2.2 CDP 3.1, 3.2 CDP 3.1, 3.2 CDP 3.1-3F, 3.2-3F, 3.3, 3.4, 3.5, 3.6, 4.1, 4.2 CDP 6.1, 6.2, 7.1, 7.2 C-3-3-3-25-300 CDP 8.1, 8.2 CDP 5.1, 5.2 Inverter Type Single-phase Single-phase Single-phase Single-phase Three-phase Three-phase Three-phase Three-phase No. of DC Inputs 1 1 2 2 1 2 3 3 DC Input U max 420 V 420 V 600 V 600 V 600 V 600 V 600 V 600 V DC Input I max 1 x 10 A 1 x 10 A 2 x 20 A 2 x 20 A 1 x 40 A 2 x 40 A 3 x 40 A 3 x 40 A DC Output to inverter 1 1 1 1 1 2 3 3 DC Overvoltage protection AC Overvoltage protection U oc máx = 1000 Vdc Imáx = 40 ka U oc máx = 1000 Vdc Imáx = 40 ka U oc máx = 1000 Vdc Imáx = 40 ka U oc máx = 1000 Vdc Imáx = 40 ka U oc máx = 1000 Vdc Imáx = 40 ka 2 Protections U oc máx = 1000 Vdc Imáx = 40 ka 3 Protections U oc máx = 1000 Vdc Imáx = 40 ka Inverter AC inputs 1 1 1 1 1 2 3 3 3 Protections U oc máx = 1000 V dc I max = 40k A Umax AC 1 x 230 V 1 x 230 V 1 x 230 V 1 x 230 V 3 x 230 / 400 V 3 x 230 / 400 V 3 x 230 / 400 V 3 x 230 / 400 V I máx AC for inverter 1p 16 A 1p 16 A 1p 25 A 1p 25 A 4p 25 A 4p 25 A 4p 25 A 1p 25 A Earth leakage protection I n / I 40 A / 30 ma 40 A / 300 ma 40 A / 30 ma 40 A / 300 ma 40 A / 300 ma 40 A / 300 ma 40 A / 300 ma 40 A / 300 ma Power analyzer - - - - Sí Sí Sí Si Reverse current relay protection 32 A 32 A 32 A 32 A 32 A 65 A 65 A 65 A

RELATED PRODUCTS Instantaneous self-consumption CDP, Dynamic Power Controller Type Code Description CDP-0 E51001 Dynamic power controller, zero injection CDP-G E52001 Dynamic power controller with demand management Requires current transformers of the MC series (.../250 ma) Time-delayed self-consumption RDB, Programmable battery charge regulator Type Code Nominal charging current from PV RDB-10 E43001 10 A 10 A RDB-20 E44001 20 A 20 A RDB-30 E45001 30 A 30 A Maximum consumption output current ISTG, Dual inverter for self consumption with storage Type Code System Power Battery Voltage ISTG - 04/80 E60480 Singlephase 4 kw 48 V 80 A Load/Download current Dispenser, single-phase meter with EDA (Energy Daily Allowance) function Type Code Description BII Dispenser E20004 Single-phase meter with EDA function, with RFID card and RS-485 communications DAM II E20000 RFID card writer DCARD E20001 RFID Card for BII Dispenser Monitoring and supervision for PV TR Series, monitoring unit for PV with 230 V ac power supply / 24 V dc power supply RS-485 / Modbus RTU Type Code Current Outputs Description TR8-RS485-25 * M54600 25 A 8 1000 V dc voltage measurement TR16-RS485-25 * M55300 25 A 16 1000 V dc voltage measurement M/TR-25 x2 M54606 Measuring module for 2 current circuits with max 25 A dc M/TR-25 x4 M54602 Measuring module for 4 current circuits with max 25 A dc TR8-RS485-100/200 M54601 Depending on transformer 8 1000 V dc voltage measurement M/TR-100 M54603 Measuring module for 1 current circuit with max 100 A dc M/TR-200 M54605 Measuring module for 1 current circuit with max 200 A dc *On demand, with UL Certification

RELATED PRODUCTS Other related products CVM MINI, Three-phase power analyzer with display, DIN rail (3 modules), 86...276 V ac power supply Type Code Isolated input Digital output Protocol Protocol CVM MINI-MC- ITF-HAR-RS485-C2 M52081 Yes 2 Modbus / RTU RS-485 CVM NET, Three-phase power analyzer w/o display, DIN rail (3 modules), 230 V ac power supply Type Code Isolated input Digital output Communic. Protocol CVM NET- MC-ITF-RS485-C2 M54B31 Yes 2 Modbus / RTU RS-485 CVM NET4 -MC, 4 Three-phase power analyzers, DIN rail (6 modules), 85...265 V ac power supply 95...300 V dc Type Code Isolated input Digital output Communic. Protocol CVM-NET4- MC-ITF-RS485-C4 M55732 Yes 4 Modbus / RTU RS-485 CVM 1D, Single-phase power analyzer with display, DIN rail (1 module), 85...276 V ac power supply Type Code Nominal current Class Power Digital Output Communic. (Protocol) CVM 1D-RS485-C M55511 250 ma...32 A 1 1 RS-485 (Modbus/RTU) MC1 / MC3, Efficient single-phase MC1 and three-phase MC3 transformers Type Code Amp. Max Class 0.5 Power Measurement Ø int. MC3-63 M73121 63 0.1 VA 3 phases 7.1 MC3-125 M73122 125 0.1 VA 3 phases 14.6 MC3-250 M73123 250 0.1 VA 3 phases 26 MC1-20-150/200/250 M73113 250 0.25 VA 1 phase 20 MC1-30-250/400/500 M73114 500 0.25 VA 1 phase 30 MC1-35-50/100/150 M73116 150 0.25 VA 1 phase 35 MC1-55-500/1000/1500 M73115 1500 0.25 VA 1 phase 55 MC1-80-1000/1500/2000 M73117 2000 0.25 VA 1 phase 80

TIME-DELAYED SELF-CONSUMPTION Solutions for Self-consumption + information: info@circutorenergy.com www.circutor.com Designed by: Image and Communications Department - CIRCUTOR, SA CIRCUTOR, SA - Vial Sant Jordi, s/n 08232 Viladecavalls (Barcelona) Spain Tel. (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14 central@circutor.es Code: C2S093-06 CIRCUTOR, SA reserves the right to change any information contained in this catalogue.