Control System Instrumentation

Similar documents
Control System Instrumentation

Module 6. Actuators. Version 2 EE IIT, Kharagpur 1

Control Valves Positioner

Control Valves Positioner

Chapter01 - Control system types - Examples

CHBE320 LECTURE III ACTUATOR AND CONTROL VALVE SELECTION. Professor Dae Ryook Yang

Components of Hydronic Systems

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Electro-Proportional Terms and Definitions

Understanding the benefits of using a digital valve controller. Mark Buzzell Business Manager, Metso Flow Control

Figure 1 Linear Output Hall Effect Transducer (LOHET TM )

Python Series Control Valves

Data Sheet. I/P and E/P converters. RS stock numbers ,

Python 1500 Series Control Valves. Pneumatic and Electric Actuators PYTHON

Familiarize yourself with the pressure loss phenomenon. The Discussion of this exercise covers the following point:

20th. SOLUTIONS for FLUID MOVEMENT, MEASUREMENT & CONTAINMENT. Do You Need a Booster Pump? Is Repeatability or Accuracy More Important?

Distributed By: M&M Control Service, Inc

Features Globe Valve 2-Way & 3-Way Assembly Features:

Series 430 Type 3430 Pneumatic Indicating Controller for Temperature with Capillary Sensor Type 3432 Controller Station Type 3436 Transmitter Module

Series W&T Pneumatic Control Valve Type RVG Globe valve and angle valve

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

Globe type control valve

CHAPTER 4 MR DAMPER DESIGN. In this chapter, details of MR damper geometry and magnetic circuit design are provided.

Series 60. New Smart Positioner. Compact design Convenient & powerful function Enhanced reliability

PYTHON 1500 SERIES CONTROL VALVES. Pneumatic and Electric Actuated

Valve Positioners Offer Improved Control Valve Performance White Paper

THE INSIDE STORY OF THE QPV OR MPV:

Becker Precision Equipment

Spring Cylinder Rotary Actuator

Flowrite Globe. Pneumatic 4-inch Valve Actuator. Valves. Description. Applications. Features D-141.

Valve Positioners Series 760P/E Valve Positioners

Exercise 4-1. Flowmeters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Rotameters. How do rotameter tubes work?

SS3 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

E-training. Positioners (Pneumatic, Electro pneumatic, I to P converters) Pneumatically actuated valves can be positioned in a number of ways.

Section Va: Valve Actuators

Direct or Reverse-Acting?

Features. Flexibility

The Discussion of this exercise covers the following points:

FEASIBILITY STYDY OF CHAIN DRIVE IN WATER HYDRAULIC ROTARY JOINT

MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY

Operability and Performance Analysis of Various Control Valves

Chapter 13: Application of Proportional Flow Control

Config file is loaded in controller; parameters are shown in tuning tab of SMAC control center

Type Type 1001 Transducers. I/P & E/P Transducers

CENTAC Inlet and Bypass Valve Positioners

INSTRUCTION MANUAL 276-5XX SERIES 4-20MA TRANSMITTERS

CONTROL VALVE SELECTION AND SIZING (ENGINEERING DESIGN GUIDELINE)

METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

Valve Positioners Series 760P/E Valve Positioners

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

Valtek Beta Positioner. Valtek Beta Positioners. for Control Valves

Characterization of a Pneumatic Control Valve

Thermal Unit Operation (ChEg3113)

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

PYTHON 1500 SERIES CONTROL VALVES. Pneumatic and Electric Actuated

Corrosion Resistant Pneumatic Positioners Model 4700P and 4700E

Config file is loaded in controller; parameters are shown in tuning tab of SMAC control center

Contents. Pressure measurement technology Pressure calibrators 18 Exercises 19-20

FlowCon Energy FIT System

Directional servo-valve of 4-way design

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

Fisher 546 Electro Pneumatic Transducer

Hydraulics in building systems. siemens.com/buildingtechnologies

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Powers Controls TT 184 Temperature Transmitters

VB-9323 Series. Application. Features. Applicable Literature. 2-1/2" to 6" 125 Lb. Flanged Three-Way Diverting Valves General Instructions

Chapter 11. Control System Instrumentation

VB-9213 Series. Application. Features. Applicable Literature

Self-operated Temperature Regulators Type 1u Temperature Regulator

3-port valves. pneumatically actuated

INSTRUCTION MANUAL 272-5X5 ANALOG TRANSMITTER (210 SERIES FLOW METERS) 272-5X7 ANALOG TRANSMITTER (220/240 SERIES FLOW METERS)

STEALTH INTERNATIONAL INC. DESIGN REPORT #1001 IBC ENERGY DISSIPATING VALVE FLOW TESTING OF 12 VALVE

SP-20 Input. Installation and Operating Instructions Electro-Pneumatic Linear Positioner. Description of Device. Part Number System


Standard Drives A & D SD Application Note

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Electro-Pneumatic Linear Positioner Installation and Operation Instructions B GB

Hydraulic Proportional and Closed Loop System Design

MM1/MM2 INSTALLATION & MAINTENANCE INSTRUCTIONS

T-1001 TYPE 1001 I/P & E/P TRANSDUCERS

PHYS 1444 Section 004. Lecture #19. DC Generator Transformer. Generalized Faraday s Law Mutual Inductance Self Inductance. Wednesday, Apr.

Practical No: Aim: List out the tools required for Instrumentation Workshop and draw the diagram of any two tools

Conditioning electronics for resistive sensors. It s not convenient to adopt a voltage divider in case of resistive sensors!

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

LEAD SCREWS 101 A BASIC GUIDE TO IMPLEMENTING A LEAD SCREW ASSEMBLY FOR ANY DESIGN

Mohit Law. Keywords: Machine tools, Active vibration isolation, Electro-hydraulic actuator, Design guidelines, Sensitivity analysis

Features...1. Modular Trim Designs... Cv Table...4. Custom Characterized and Packing...5. How to Specify Control Valve...6. Unbalanced Design...

The Mechanics of Tractor - Implement Performance

Hydraulics in building systems

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Mechatronics Chapter 10 Actuators 10-3

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

Baumann Pneumatic Pressure Controller (for Industrial and Sanitary Applications)

ABB MEASUREMENT & ANALYTICS DATA SHEET. AV1 and AV2 Characterizable pneumatic and electro-pneumatic positioners

SOME FACTORS THAT INFLUENCE THE PERFORMANCE OF

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

Improvement of Vehicle Dynamics by Right-and-Left Torque Vectoring System in Various Drivetrains x

Transcription:

Control System Instrumentation Feedback control of composition for a stirred-tank blending system. Four components: sensors, controllers, actuators, transmission lines 1

Figure 9.3 A typical process transducer. Transducers and Transmitters Figure 9.3 illustrates the general configuration of a measurement transducer; it typically consists of a sensing element combined with a driving element (transmitter). 2

Transducers for process measurements convert the magnitude of a process variable (e.g., flow rate, pressure, temperature, level, or concentration) into a signal that can be sent directly to the controller. Chapter 9 The sensing element is required to convert the measured quantity, that is, the process variable, into some quantity more appropriate for mechanical or electrical processing within the transducer. Standard Instrumentation Signal Levels Before 1960, instrumentation in the process industries utilized pneumatic (air pressure) signals to transmit measurement and control information almost exclusively. These devices make use of mechanical force-balance elements to generate signals in the range of 3 to 15 psig, an industry standard. 3

Since about 1960, electronic instrumentation has come into widespread use. Chapter 9 Sensors The book briefly discusses commonly used sensors for the most important process variables. (See text.) Transmitters A transmitter usually converts the sensor output to a signal level appropriate for input to a controller, such as 4 to 20 ma. Transmitters are generally designed to be direct acting. In addition, most commercial transmitters have an adjustable input range (or span). For example, a temperature transmitter might be adjusted so that the input range of a platinum resistance element (the sensor) is 50 to 150 C. 4

In this case, the following correspondence is obtained: Input Output 50 C 4 ma 150 C 20 ma Chapter 9 This instrument (transducer) has a lower limit or zero of 50 C and a range or span of 100 C. For the temperature transmitter discussed above, the relation between transducer output and input is Tm 20 ma 4 ma ma = 50 C + 4 ma o o 150 C 50 C ( ) ( o T ) ma 0.16 ( o = T C) 4 ma o C 5

The gain of the measurement element K m is 0.16 ma/ C. For any linear instrument: K m = range of instrument output range of instrument input (9-1) Figure 9.4 A linear instrument calibration showing its zero and span. 6

Final Control Elements Every process control loop contains a final control element (actuator), the device that enables a process variable to be manipulated. Chapter 9 For most chemical and petroleum processes, the final control elements (usually control valves) adjust the flow rates of materials, and indirectly, the rates of energy transfer to and from the process. There are many different ways to manipulate the flows of material and energy into and out of a process; for example, the speed of a pump drive, screw conveyer, or blower can be adjusted. However, a simple and widely used method of accomplishing this result with fluids is to use a control valve, also called an automatic control valve. The control valve components include the valve body, trim, seat, and actuator. 7

Figure 9.7 A pneumatic control valve (air-to-open). Air-to-Open vs. Air-to-Close Control Valves Normally, the choice of A-O or A-C valve is based on safety considerations. 8

We choose the way the valve should operate (full flow or no flow) in case of a transmitter failure. Hence, A-C and A-O valves often are referred to as fail-open and fail-closed, respectively. Chapter 9 Example 9.1 Pneumatic control valves are to be specified for the applications listed below. State whether an A-O or A-C valve should be used for the following manipulated variables and give reason(s). a) Steam pressure in a reactor heating coil. b) Flow rate of reactants into a polymerization reactor. c) Flow of effluent from a wastewater treatment holding tank into a river. d) Flow of cooling water to a distillation condenser. 9

Valve Positioners Pneumatic control valves can be equipped with a valve positioner, a type of mechanical or digital feedback controller that senses the actual stem position, compares it to the desired position, and adjusts the air pressure to the valve accordingly. Chapter 9 Specifying and Sizing Control Valves A design equation used for sizing control valves relates valve lift l to the actual flow rate q by means of the valve coefficient C v, the proportionality factor that depends predominantly on valve size or capacity: q = C f l v ΔP v ( ) (9-2) g s 10

( ) Here q is the flow rate, f l is the flow characteristic, ΔPv is the pressure drop across the valve, and g s is the specific gravity of the fluid. This relation is valid for nonflashing fluids. Specification of the valve size is dependent on the so-called valve characteristic f. Three control valve characteristics are mainly used. For a fixed pressure drop across the valve, the flow characteristic f ( 0 f 1) is related to the lift l( 0 l 1), that is, the extent of valve opening, by one of the following relations: Linear: f = l Quick opening: f = l (9-3) 1 = R l Equal percentage: f where R is a valve design parameter that is usually in the range of 20 to 50. 11

Figure 9.8 Control valve characteristics. 12

Rangeability The rangeability of a control valve is defined as the ratio of maximum to minimum input signal level. For control valves, rangeability translates to the need to operate the valve within the range 0.05 f 0.95 or a rangeability of 0.95/0.05 = 19. To Select an Equal Percentage Valve: a) Plot the pump characteristic curve and ΔP s, the system pressure drop curve without the valve, as shown in Fig. 9.10. The difference between these two curves is ΔP v. The pump should be sized to obtain the desired value of ΔPv/ ΔPs, for example, 25 to 33%, at the design flow rate q d. 13

( ) Figure 9.10 Calculation of the valve pressure drop ΔP v from the pump characteristic curve and the system pressure drop without the valve ( ΔP s ). 14

b) Calculate the valve s rated C v, the value that yields at least 100% of q d with the available pressure drop at that higher flow rate. c) Compute q as a function of l using Eq. 9-2, the rated C v, and ΔP v from (a). A plot of the valve characteristic (q vs. l ) should be reasonably linear in the operating region of interest (at least around the design flow rate). If it is not suitably linear, adjust the rated C v and repeat. Example 9.2 A pump furnishes a constant head of 40 psi over the entire flow rate range of interest. The heat exchanger pressure drop is 30 psig at 200 gal/min (q d ) and can be assumed to be proportional to q 2. Select the rated C v of the valve and plot the installed characteristic for the following case: a) A linear valve that is half open at the design flow rate. 15

Figure 9.9 A control valve placed in series with a pump and a heat exchanger. Pump discharge pressure is constant. 16

Solution Chapter 9 First we write an expression for the pressure drop across the heat exchanger ΔPhe q = 30 200 2 2 (9-5) q Δ Ps =Δ Phe = 30 (9-6) 200 Because the pump head is constant at 40 psi, the pressure drop available for the valve is q Δ Pv = 40 Δ Phe = 40 30 (9-7) 200 Figure 9.11 illustrates these relations. Note that in all four design cases ΔP / Δ P = 10/ 30 = 33% at q d. v s 2 17

Figure 9.11 Pump characteristic and system pressure drop for Example 9.2. 18

a) First calculate the rated C v. 200 C v = = 126.5 (9-8) 0.5 10 Chapter 9 We will use C v = 125. For a linear characteristic valve, use the relation between and q from Eq. 9-2: l l = C v q ΔP v (9-9) Using Eq. 9-9 and values of ΔP v from Eq. 9-7, the installed valve characteristic curve can be plotted. 19

Figure 9.12 Installed valve characteristics for Example 9.2. 20

Figure 9.16 Schematic diagram of a thermowell/thermocouple. 21

Dynamic Measurement Errors An energy balance on the thermowell gives Chapter 9 dtm mc = UA T T dt ( ) (9-13) where U is the heat transfer coefficient and A is the heat transfer area. Rearranging gives mc dtm + T T m = UA dt m (9-14) Converting to deviation variables and taking the Laplace transform gives ( s) ( ) Tm 1 = T s τs+ 1 (9-15) with τ mc / UA. 22

Figure 9.13 Analysis of types of error for a flow instrument whose range is 0 to 4 flow units. 23

Accuracy in Instrumentation Error = true value measured value Chapter 9 Precision = the smallest possible incremental value which can be measured Resolution = the smallest change in input that will result in a significant change in transducer output Repeatability = max/min of the measured values average of the measured values. 24

Figure 9.14 Analysis of instrument error showing the increased error at low readings (from Lipták (1971)). 25

Figure 9.15 Nonideal instrument behavior: (a) hysteresis, (b) deadband. 26