MINI MCR-SL-UI-UI(-SP)(-NC)

Similar documents
MINI MCR-SL-UI-UI(-SP)

PHOENIX CONTACT - 01/2008

QUINT-PS/24DC/24DC/ 5/CO

QUINT-PS/24DC/24DC/20

QUINT-PS/24DC/48DC/ 5

onlinecomponents.com

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

QUINT-PS/24DC/24DC/10

QUINT-PS/48DC/24DC/5. DC/DC converter with SFB technology, primaryswitched, input: 48 V DC, output: 24 V DC, output current: 5 A.

QUINT-PS/24DC/24DC/10/CO

DC/DC converters - MINI-PS DC/ 5-15DC/

DIN EN UL 508 / CSA 3RF A A 0 2

Solid State Relays, 3-phase

Safety Standards. Model Number:

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

PHOENIX CONTACT

ST-COMBI 4 mm 2 Pluggable Spring-Cage Terminal Blocks

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

PIT 2,5-TG. Extract from the online catalog. Order No.:

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC

STS 2,5. Extract from the online catalog. Order No.:

Industrial Power Supplies

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

DEVICE STATE/BYPASSED FAILURE OVERLOAD

JUMO MIDAS S05 Pressure transmitter Type

SIRIUS 3RU2 Thermal Overload Relays

PT 2,5-QUATTRO-PE. Extract from the online catalog. Order No.:

PT 2,5-TWIN/1P BU. Extract from the online catalog. Order No.:

PT 2,5-TWIN/1P BU. Extract from the online catalog. Order No.:

Solenoid Operator 0516 / 1216

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Safety technique. Emergency Stop Module BH 5928, BI 5928

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

Series 3730 Electropneumatic Positioner Type

Model Number Structure

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Solenoid Operator 0513 / 1213

Installation Instructions Electronic pressure sensor. PX3111 PX322x PX323x PX3244 PX3422 PX911x PX913x

Technical specifications

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Pressure transmitter JUMO dtrans p02

PT 2,5-QUATTRO/2P BU. Extract from the online catalog. Order No.:

ST 4-HESI (5X20) Extract from the online catalog. Order No.: Fuse terminal block for assembly on NS 35, for 5 x 20 cartridge fuse inserts

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Safety Switches Series 8537

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

DC POWER SUPPLY ALIMENTATION C.C.

Switching DC Power Supply

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

General technical data: CONTACTOR, AC-3, 18.5KW/400V, 1NO+1NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL. product brand name

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

SPT- I / U PRESSURE TRANSMITTER for general applications

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Declaration of Conformity

OPERATING INSTRUCTIONS

! CAUTION! Damages on the machine possible.

INDUSTRIAL POWER SUPPLIES SFL-SERIES

Operating instructions Flow monitors SI / / 2010

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name

CONTROL MICROSYSTEMS Power Supply. Hardware Manual

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

MV Series. We put you first. And keep you ahead. SMITH METER TURBINE METERS FEATURES OPERATING SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 1.

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

MODEL IRMA - INTELLIGENT RTD MODULE WITH ANALOG OUTPUT

H3DS-X - Solid State Two-Wire Timer

2-channel analog input module; Pt100 / RTD; for resistance sensors

Spring Cage Miniature Terminal Blocks FK-MPT 0,5/ -3,5

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name

GETTING STARTED GUIDE NI AO, ±10 V, 16 Bit, 25 ks/s/ch Simultaneous

Technical Datasheet P-30/P-31. Standard transmitter.

LED Driver Linear / area fixed output

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Pressure Transmitter JUMO dtrans p30 Type

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

199.9 µa to A *, mv (AC or DC) * Accessory Shunts Available For Higher Current Ranges.

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Uninterruptible power supplies (UPS)

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Control Circuit Protection

Load and Motor Switches, Load-Break Switches Series 8544

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

Power Plugs for Proportional Valves (12 volt supply)

Type A-10 General Purpose Pressure Transmitters

Electromagnetic Flow Monitor magphant

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

Switching Power Supplies

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

Solid State Relays contactor with Integrated Fuse Type RGC1F

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

2 pole, 10 A AC/DC supply non polarized Plug-in for use with 94 series sockets

Load and Motor Switches, Load-Break Switches Series 8549

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

Transcription:

Configurable 3-Way Isolating Amplifier Data Sheet 04/2005 Functions Features The configurable 3-way isolating amplifier MINI MCR-SL-UI-UI(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog signals. On the input and output side, the standard signals 0...20 ma, 4...20 ma, 0...10 V, 2...10 V, 0...5 V or 1...5 V are available, electrically isolated. The DIP switch accessible on the side of the housing allows the configuration of the input and output signal ranges. The voltage supply (19.2...30 V DC) can either be provided via connecting terminal blocks "3"/"4" or "7"/"8" of the modules, or together, via the DIN rail connector (see Figure 5 on page 7). Please also observe "Power Supply" on page 8. Figure 1 Features 1 Input: Standard signals 2 Transparent cover 3 Potentiometer for adjustment 4 Groove for ZBF 6 Zack marker strip 5 Output: Standard signals 6 Supply voltage 7 Connection option for DIN rail connector 8 DIP switch S1 9 DIP switch S2 10 Universal snap-on foot for EN mounting rails 101945_02_en 1

Technical Data General Data Supply voltage Current consumption at 24 V DC Power consumption Transmission error With alignment Without alignment Temperature coefficient max. typ. Cut-off frequency Step response (10...90 %) Test voltage (input / output / supply) Ambient temperature range 19.2...30 V DC < 19 ma, incl. 20 ma load current < 450 mw < 0.1% < 0.4% < 0.01%/K < 0.002%/K 100 Hz 3.5 ms 1.5 kv, 50 Hz, 1 min. Operation Storage Dimensions (W x H x D) -20 C +65 C -40 C +85 C 6.2 mm x 93.1 mm x 102.5 mm Conductor cross section 0.2...2.5 mm 2 (AWG 24...12) Stripping length Screw connection Spring-cage connection Housing design Tests / Approvals 12 mm 8 mm Polybutylenterephthalate PBT, green c u F U PROCESS CONTROL EQUIPMENT FOR HAZARDOUS LOCATIONS LISTED 31ZN Class I Div 2 Groups A, B, C, D T5 A) This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non-hazardous locations only. B) Warning - explosion hazard - substitution of components may impair suitability for Class 1, Division 2. Statement of conformity in acc. with EN 60079-15 C) Warning - explosion hazard - do not disconnect equipment unless power has been switched off or the area is known to be non-hazardous. X II 3 G Ex na II T4 X 2 101945_02_en

Input (see Figure 1, detail 1) I IN U IN Input signal range (configurable) 0...20 ma, 4...20 ma 0...10 V, 2...10 V, 0...5 V, 1...5 V Max. input signal 50 ma 30 V Input resistance 50 Ω, approx. 100 kω, approx. Output (see Figure 1, detail 5) I OUT U OUT Output signal range (configurable) 0...20 ma, 4...20 ma 0...10 V, 2...10 V, 0...5 V, 1...5 V Load < 500 Ω (20 ma) 10 kω Ripple < 20 mv ss (500 Ω) < 20 mv ss Max. output signal 28 ma / 12.5 V 12.5 V / 22 ma Conformance With EMC Guideline 89/336/EEC And Low Voltage Directive 73/23/EEC Immunity to Interference According to EN 61000-6-2 1 Discharge of static electricity (ESD) EN 61000-4-2 Criterion B 2 Electromagnetic HF field EN 61000-4-3 Criterion A 3 Fast transients (Burst) EN 61000-4-4 Criterion B 4 Surge voltage capacities (Surge) EN 61000-4-5 Criterion B 4 Conducted disturbance EN 61000-4-6 Criterion A 3 Noise Emission According to EN 61000-6-4 Noise emission of housing EN 55011 5 Class A 6 1 EN 61000 corresponds to IEC 1000 2 Criterion B: Take protective measures against electrostatic discharge. 3 Criterion A: Normal operating behavior within the defined limits. 4 Criterion B: Temporary impairment to operational behavior that is corrected by the device itself. 5 EN 55011 corresponds to CISPR11 6 Class A: Area of application industry. 101945_02_en 3

Ordering Data Description Order Designation Order No. Configurable 3-way isolating amplifier MINI MCR-SL-UI-UI 28 64 38 3 Screw terminal block, preconfigured (see "Ordering Key for MINI MCR-SL-UI-UI and MINI MCR-SL-UI-UI-SP" on page 5) Configurable 3-way isolating amplifier MINI MCR-SL-UI-UI-NC 28 64 15 0 Screw terminal block, standard configuration (see "Standard Configuration" on page 8) Configurable 3-way isolating amplifier MINI MCR-SL-UI-UI-SP 28 64 71 0 Spring-cage terminal block, preconfigured (see "Ordering Key for MINI MCR-SL-UI-UI and MINI MCR-SL-UI-UI-SP" on page 5) Configurable 3-way isolating amplifier Spring-cage terminal block, standard configuration (see "Standard Configuration" on page 8) MINI MCR-SL-UI-UI-SP-NC 28 64 16 3 Accessories Description Order Designation Order No. DIN rail connector ME 6,2 TBUS-2 1,5/5-ST-3,81 GN 28 69 72 8 Power terminal block with screw connection MINI MCR-SL-PTB 28 64 13 4 Power terminal block with spring-cage connection MINI MCR-SL-PTB-SP 28 64 14 7 System power supply (not for Zone 2!) MINI-SYS-PS-100-240AC/24DC/1,5 28 66 98 3 4 101945_02_en

Ordering Key for MINI MCR-SL-UI-UI and MINI MCR-SL-UI-UI-SP If the customer order information is incorrect or missing, the standard configuration is delivered (shown as an example in the ordering key). Order No. Input Range Output Range Manufacturer s Calibration Certificate WKZ 28 64 38 3 / 28 64 71 0 / IN03 / OUT01 / NONE (see "Ordering Data") IN01 = 0...20 ma OUT01 = 0...20 ma NONE = without WKZ IN02 = 4...20 ma OUT02 = 4...20 ma YES = with WKZ (a charge IN03 = 0...10 V OUT03 = 0...10 V will be made) IN04 = 2...10 V OUT04 = 2...10 V YESPLUS = WKZ with IN05 = 0...5 V OUT05 = 0...5 V IN06 = 1...5 V OUT06 = 1...5 V 5 measuring points (a charge will be made) Installation Screw Connection Spring-Cage Connection Figure 2 MINI MCR-SL-UI-UI MINI MCR-SL-UI-UI-NC Figure 3 MINI MCR-SL-UI-UI-SP MINI MCR-SL-UI-UI-SP-NC 101945_02_en 5

The device may only be installed and put into operation by qualified personnel. The corresponding national regulations (e.g. VDE, DIN) must be observed. Notes for Ex: The device is category 3 electrical apparatus. Please observe the instructions given here for installation. The device must be installed in a housing with IP54 protection in acc. with EN 60529. The limits for mechanical or thermal loads described for the device must not be exceeded. Only devices designed for operation in the hazardous areas of Zone 2 may be connected. Under no circumstances may repairs be carried out by the user. Only engage or connect conductors in the hazardous area when the device is deenergized! The assignment of the connecting terminal blocks is shown in Figure 4. Block Diagram Figure 4 Block diagram The MINI Analog module can be snapped onto all 35 mm DIN rails corresponding to EN 60715. 6 101945_02_en

Using DIN rail connector ME 6,2 TBUS-2 1,5/5-ST-3,81 GN (Order No.: 28 69 72 8) Please also pay particular attention to the direction of the MINI Analog module and DIN rail connector when snapping into position: Snap-on foot (Figure 5, detail D 10) below and plug (Figure 5, detail C 11) left! First position the DIN rail connector in the DIN rail to bridge the voltage supply (see Figure 5). Figure 5 Mounting/Removing 101945_02_en 7

Power Supply Never connect the supply voltage directly to the DIN rail connector! It is not permitted to draw power from the DIN rail connector or from individual MINI Analog modules! Feeding in power via the MINI Analog module Where the total current consumption of the aligned MINI Analog modules does not exceed 400 ma, the power can be fed in directly at the connecting terminal blocks of a MINI Analog module. We recommend connecting a 400 ma fuse upstream. Feeding in power with a power terminal block Power terminal block MINI MCR-SL-PTB (Order No.: 28 64 13 4) or MINI MCR-SL-PTB-SP (Order No.: 28 64 14 7), of the same shape, is used to feed in the supply voltage to the DIN rail connector. We recommend connecting a 2 A fuse upstream. Feeding in the power with a system power supply unit System power supply unit MINI-SYS-PS-... (Order No.: 28 66 98 3) with 1.5 A output current contacts the DIN rail connector with the supply voltage, allowing several MINI Analog modules to be supplied from the network. Configuration Electrostatic Discharge! The module contains components that can be damaged or destroyed by electrostatic discharge. When handling the module, observe the necessary safety precautions against electrostatic discharge (ESD), in accordance with EN 61340-5-1 and EN 61340-5-2, as well as IEC 61340-5-1 and IEC 61340-5-2. DIP switches S1 and S2 (see Figure 1, details 8 and 9) are used to define the combination of input and output standard signal ranges (see "Configuration Table" on page 9). Standard Configuration If it is an "NC version" (MINI MCR-SL-UI-UI-NC or MINI MCR-SL-UI-UI-SP-NC), the device has the following standard configuration: Input 0...10 V, Output 0...20 ma (All DIP switches in the "off" position, transmission error < 0.1%). 8 101945_02_en

Configuration Table DIP S2 DIP S1 IN OUT 1 2 3 4 5 6 1 2 0...10 V 0...20 ma off off off off off off off off 4...20 ma off off off off off ON off off 0...10 V ON off ON off off off off off 2...10 V ON off ON off off ON off off 0...5 V ON ON off off off off off off 1...5 V ON ON off off off ON off off 2...10 V 0...20 ma off off off ON ON off off off 4...20 ma off off off off off off off off 0...10 V ON off ON ON ON off off off 2...10 V ON off ON off off off off off 0...5 V ON ON off ON ON off off off 1...5 V ON ON off off off off off off 0...5 V 0...20 ma off off off off off off ON off 4...20 ma off off off off off ON ON off 0...10 V ON off ON off off off ON off 2...10 V ON off ON off off ON ON off 0...5 V ON ON off off off off ON off 1...5 V ON ON off off off ON ON off 1...5 V 0...20 ma off off off ON ON off ON off 4...20 ma off off off off off off ON off 0...10 V ON off ON ON ON off ON off 2...10 V ON off ON off off off ON off 0...5 V ON ON off ON ON off ON off 1...5 V ON ON off off off off ON off 0...20 ma 0...20 ma off off off off off off off ON 4... 20 ma off off off off off ON off ON 0...10 V ON off ON off off off off ON 2...10 V ON off ON off off ON off ON 0...5 V ON ON off off off off off ON 1...5 V ON ON off off off ON off ON 4...20 ma 0...20 ma off off off ON ON off off ON 4...20 ma off off off off off off off ON 0...10 V ON off ON ON ON off off ON 2...10 V ON off ON off off off off ON 0...5 V ON ON off ON ON off off ON 1...5 V ON ON off off off off off ON 101945_02_en 9

Alignment Below the transparent cover is a potentiometer (see Figure 1, detail 3), with which a fine adjustment of the analog signals can be carried out after the configuration of the DIP switches has been altered. The transmission error without adjustment is < 0.4%. Using the potentiometer, the error can be adjusted to < 0.1%. Make sure you always use the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf. PHOENIX CONTACT GmbH & Co. KG Flachsmarktstr. 8 32825 Blomberg Germany + 49 - (0) 52 35-3-00 + 49 - (0) 52 35-3-4 12 00 www.phoenixcontact.com Worldwide Locations: www.phoenixcontact.com/salesnetwork PHOENIX CONTACT 04/2005 Technical modifications reserved 10 101945_02_en