Sand Trap Louvers OSTL 300 SERIES. Sand Trap Louvers

Similar documents
WE GUIDE AIR LOUVERS

Air Louvers OFAL 300 SERIES

BC 08. Sand Trap Louvers STL-AB-11A LISTED

EXHAUST AND AIR LOUVERS CHAPTER 5

Dampers. Louvers. Caring for Human Life & Property (FIRE, SMOKE & HVAC) NAFFCOFlow.com

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

AL-Maraj Central A/C Systems Accessories Mfg Co.

ARROW INDUSTRIAL PRODUCTS

STATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS

BC 09. Pressure Relief Dampers PRD-GAB-12B LISTED

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

MOTORIZED VOLUME DAMPER

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

SECTION DUCTWORK ACCESSORIES

External grilles USAV, USVN, USSV and SVN TECHNICAL DATA

Product Nomenclature G-X-AB-Z 0 = Zero Degree, 1 = 15 Degree, 2 = 15 Degree (2-way)

Automatic Roof Door Vents

Outside Louvers. Series OHCL, OHL, OHL-CD, OHL-D, OHL-KD, OHL-LAOGS, OHL-LOUVER DOOR, OHL-ST2/ST4, OVL & PHL

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan GRAVITY VENTILATORS MGI & MGR GRV TEL & TIL LUG CATALOG 4720 MAY 2014

Centrifugal Filtered Supply Roof Blowers

series Linear grilles

FOR AIR CONDITIONING AND VENTILATING APPLCATIONS

Weather-Resistant Louvres

Splash-proof Terminal HEPA Filter

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

L O U V E R S & D A M P E R S

Incorporating V2.1. Product spec >>> > Series WL - Standard weather louvres

PC-125x Counter-Balanced Backdraft Damper

Trox-o-mat Automatic Roll Filters F1/1/EN/5

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

Louvre systems. Series WLD Weather louvre doors. Incorporating. Fully active louvre panel integrated into a door

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

CRYSTAL-AIRE. concealed commercial air cleaners

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

HIGH CAPACITY LINEAR SLOT DUFFUSERS

KLIMA Active Chilled Beams

ISSUE B, OCT Architectural Square Ceiling Diffusers. UNI & AUNI Diffusers. Advanced Air

Bifurcated Case Axial Fans (BIFA)

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise

Air distribution product

PT. COMFORT AIRE ANEKA TEKNIK

C O L M A N. Air Distribution TRANSFER GRILLES G SERIES SERIES

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP

Series HCD Airfoil Control Damper

Twin City Fan & Blower

Variable Air Volume Dampers

LINEAR DIFFUSERS AND BAR GRILLES

Ceiling swirl diffusers

Ceiling swirl diffusers

PLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES

Engineering Brochure. T-Model Cooling Towers A Manufacturer for 42 Years MEMBER

LINEAR SLOT DIFFUSERS

Engineering Brochure. T-Model Cooling Towers A Manufacturer for 40 Years! The MEMBER

AFL-501. Aluminum FEMA 361 Louver Chevron Blade Application and Design

SINGLE DUCT TERMINAL UNITS

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

BL Series Louvres. Factory Assembled Louvre Panels

McKenzie Martin Louvres & Ventilation Systems Louvres Maximair Louvre Systems Turret Louvres

(click on page links below) XAL-2C Technical Data 1. XAL-4C Technical Data 3

AIR HANDLING UNIT. MODEL: PM0809 to PM CFM to CFM

Roof Upblast and Sidewall Exhaust

Floor Swirls Models BZD and SZD

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

LINEAR DIFFUSERS AND BAR GRILLES

AIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements

For installation into ductwork

INDEX. Chapter1 1. A. Jet diffusers 1. Jet diffuser...: AJD-P

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide.

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

(click on page links below) General & Performance Data 1. Suggested Spec 3. Accessories 4

Filtered Kitchen Supply Packaged Ventilator

Ventilation grilles for installation into walls, sills or rectangular

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty

Application Guidelines

DIrect drive exhaust & supply panel fans

MODEL OAL. Water Penetration. Water Penetration. Free Area OAL PERFORMANCE REGISTERS GRILLES &

Rotary Heat Wheel (Rotary Enthalpy Wheel)

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

AMOUNT IN Rs After adding percentage above or at par or below In In words figures. ESTIMATED COST (IN Rupees) In figures. In words

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

Clean Air Products Straight Thru Standard Profile Single Door Air Shower Purchase Specification

EGG CRATE RETURN GRILLE

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación

SECTION HVAC AIR CLEANING DEVICES

Complete HVAC Capability

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

VENTILATION GRILLES OVERVIEW AND TECHNICAL DATA

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Inline and Roof Mounted Fans

Transcription:

Model : OSTL GI 341 Description: OPTIMA make Sand Trap Louver is used as pre-filter for the protection of air conditioning plants in area exposed to extreme levels of industrial pollution. It has a high degree of separation capability of sand and large dust particles, even in case of high dust concentrations. The vertically arranged sections and holes for sand drainage ensure the sand trap louver is self-cleaning and maintenance-free. The STL is designed to separate large particles at low air velocities, thus avoiding excessive dust loading of conventional filters. It s not intended as a substitute for conventional supply air filtration plant. For bigger sizes, several sections can be combined to provide any combinations of overall width W or height H. STL with H 1950 mm to 3900 mm are split on height and supplied with additional sand chute, loose for fitting on site by others. The additional support for reinforcement and assembly of the sand trap louvers with W 1950 mm to 3900 mm are also split and supplied with a loose channel section to cap the vertical joint, channel to be fitted on site by others. Single Section Sizes Performance Data - The filtration performance is dependent on the dust type and the velocity of the air. APPLICATION: The sand trap louver is used at the fresh air inlet duct of the air handling unit. It can lower the dust loading of conventional filtration as it is designed to separate large size sand particles at low to medium speeds. It is also fitted with a bird screen mesh protect against the unwanted objects. The sand trap louver is a self emptying system. It has a set of holes at the bottom face of the casing to discharge separated sand particles. OUT STANDING FEATURES: Designed for intake applications to separate sand from intake air. A typical efficiency / Performance data is shown in Fig. enclosed. Provided with self emptying sand drain holes from the base. Choice of either galvanized steel or aluminum construction. Variety of Bird and Insect Screen.

Model OSTL GI 341 STANDARD MATERIALS AND CONSTRUCTION: Frame : 1.2 mm thick GI steel sheets G-90, Zinc coating Z-275 as per ASTM653 Standard Blades : 0.9 mm to 1.2 mm thick GI steel sheets G-90, Zinc coating Z-275 as per ASTM653 Standard Assembly : Mechanically fastened with GI rivets of size 4.8 mm x 12 mm. Bird Mesh : ½ x ½ x 0.051 diameter wire OR 12 mm x 12 mm x 1 mm diameter wire GI mesh PVC coated Finish : Mill Finish or Powder Coated. OPTIONS: Powder Coated or Spray paint Finish Variety of Bird and Insect Mesh. Options in thickness of GI material up to 2 mm Can be factory supplied with as a special assembly of Wire Mesh, VCD, Sliding AL Filter (detachable). DIMENSIONS: Width W and Height H are opening dimensions. STL is provided with approximately ½ undercut. Shipping weight is approximately 4 lbs/sq.ft. STL sizes : Standard sizes are as below. Other sizes are optional. Min. size panel = 12 W x 10 H Max. Single Panel = 96 W x 48 H OSTL - GI 341 Sections : Standard sections for STL are shown. Other sections supplied as optional Model: OSTL GI 341 30 25 76 101 105 20 80 80 140

Model OSTL AL 341 STANDARD MATERIALS AND CONSTRUCTION: Frame : 1 mm thick nominal; 6063-T6 extruded aluminum alloy. Conform to BS1474 Blades : 1 mm thick nominal; 6063-T6 extruded aluminum alloy. Conform to BS1474 Assembly : Mechanically fastened with AL Rivets 4.8 mm x 12 mm. Screen : ½ x ½ x 0.051 inch diameter wire OR 12 X 12 X 1 mm AL coated wire Finish : Mill Finish or Powder coated OPTIONS: Powder Coated or Anodized Finish Variety of Bird and Insect Screen. Options in thickness of extruded Aluminium section up to 2 mm Can be factory supplied with as a special assembly of Wire Mesh, VCD, Sliding AL Filter (detachable). DIMENSIONS: Width W and Height H are opening dimensions. STL is provided with approximately ½ undercut. Shipping weight approximately 4 lbs/sq.ft. STL sizes: Standard sizes are as below. Other sizes are optional. Min. size panel = 12 W x 12 H Max. Single Panel = 60 W x 60 H OSTL- AL 341 Extruded Sections : Dimensional Tolerance as per EN: 12020-2-2001, EN 755-9-2001 Heat Treatment : Webster Hardness # 11-13, Solution heat treated and age hardened. Model: OSTL AL 341C (With Sand Chute) 30 25 76 101 20

Assembly Sketches: VERTICAL SECTION HORIZONTAL SECTION SINGLE SECTION WITH SAND CHUTE MULTIPLE SECTION WITH SAND CHUTE

PRESSURE DROP: Data for inlet application with rear duct or plenum connection SAND REMOVAL EFFICIENCY:

PERFORMANCE DATA: The filtration performance is dependant on the dust type and the velocity of the air. Particles Size Filtration Efficiency in % Range at 1.0 m/s at 2.0 m/s 350-700 90 70 75-700 60 approx. 30 Selection: SELECTION EXAMPLE: For normal operation conditions the sand trap louvers should be rated for a face velocity of approximate 1.0 m/s Volume Flow with a face velocity of 1.0 m/s : 2430 l/s (8750) Cu.m. /h Area of louver required : approx. 2.4 M. Sq. Dimensions selected: Width Height Pressure drop : W = 1800 mm : H = 1350mm : approx. 30 Pa

FRESH AIR INTAKE SYSTEM WITH SAND TRAP LOUVER