AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

Similar documents
MICROMANOMETER ALNOR MODEL AXD610 AIRFLOW INSTRUMENTS MODEL PVM610

VELOCICALC Air Velocity Meter

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

Ventilation Testing. Micromanometer. Alnor Model AXD610 AIRFLOW TM Model PVM610. Operation and Service Manual

Indoor Air Quality Meter

DP-CALC TM Micromanometer

IAQ-CALC TM Indoor Air Quality Meter

IAQ-CALC TM Indoor Air Quality Meter

Rotating Vane Anemometer

OWNER S MANUAL. Model 9880 Intrinsically Safe Air Velocity Meter

Model 8340 Intrinsically Safe VELOCICHECK Air Velocity Meter

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Rotating Vane Anemometer

PRIMARY CALIBRATORS MODEL 4046/4146

Model 8345/8346/8347/8347A VELOCICALC Air Velocity Meters

Model 8026 Particle Generator

Model 8026 Particle Generator

Thermo-Anenometer Model Owner s Manual

ANALOG BALANCING TOOL MODELS ABT701, ABT703, ABT711, ABT713

AXD 530 MicroManometer

Exhaust Fan Flow Meter. Operation Manual. The ENERGY CONSERVATORY DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE

EXHAUST FAN FLOW METER

Table of Contents Up and Running... 1 Measurements... 2 Keypad Operation... 4 Displayed Items... 4 Placement for Monitoring/Testing...

WIRING DIAGRAMS FOR BRIDGE CONTROL PANELS

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

EAGL 1-Touch Laser Level

Infrared Thermocouple Probe

HIGH VOLTAGE DIGITAL AMMETER

AXD 510 MicroManometer

PVI 60KW, PVI 82KW, PVI 95KW

HR-20P Pneumatically Controlled Pressure Regulator

COMMAND SERIES 410-L T L T T T L06R RS PRODUCT MANUAL

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

This manual covers the following model:

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

"WHERE TUBING AND FITTINGS COME TOGETHER"

OPERATING INSTRUCTIONS AND PARTS LIST BRIDGE DRIVE GEAR CASE

Installation / Operation Instructions Sunnex ORION Series Exam Lights

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

SOLUTION DISTRIBUTORS BOOK NO. IM AA UA

SUNTURA SOLAR TRACKER

INSTALL GUIDE Dodge/RAM 5.7L HEMI

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

Hydronic Manometers. Hydronic Manometer. Model HM680. Owner s Manual

INSTRUCTIONS SMOKE BLOWER WITH HONDA ENGINE PART NUMBER

User's Manual. Model Hot Wire Thermo-Anemometer. Introduction

INSTALL GUIDE Silverado/Sierra L/6.2L

SUNTURA HD SOLAR TRACKER

INSTRUCTION MANUAL. Rotary Unidirectional Piezoelectric Motor Evaluation Kit. (Model: UPM-28) Made in USA

INSTALL GUIDE Jeep Wrangler JK 3.6L V6

i400s Calibration Information Introduction

Tachometer. English. Users Manual

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

NEUTRALIZATION SYSTEM FOR OPA & GLUTARALDEHYDE MEDI-NEWT. User Manual. Endoscope reprocessing the the way way it it should be be

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

OPERATING INSTRUCTIONS AND PARTS LIST

362 Clamp Meter. Users Manual

Broadband PowerShield. CP27U Models. User Manual

FREQUENTLY ASKED QUESTION SERIES. BANJO BOLTS WHY THE BAD RAP? 6.0L Powerstroke Diesel. Last Updated: 7/2/2018 Page 1 of 3 S Diesel, LLC

CRD400 Fitting Inserter OPERATIONS MANUAL

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

SINGLE STICK DIGITAL VOLTMETER

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type


INSTALL GUIDE Ford F L

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

323/324/325 Clamp Meter

Respirator Fit Testers

Slimline Duals Installation Instructions Harley-Davidson Touring Models 2009-Current

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

CRD600 Automatic Fitting Inserter

Harley Davidson FL Touring Current Xtreme

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

SIDESLIDE SERIES C-CLAMP 940K-010FI BOLT 940K-010RSC PICATINNY 940K-010PIC PRODUCT MANUAL

Mechanical Spiral Sensor

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

Loctite Spray Valve Controller Part Number EQUIPMENT Operation Manual

CRD610 Automatic Fitting Inserter

BEFORE YOU BEGIN LIST OF COMPONENTS. Isopropyl SWITCH SCOTCH-BRITE PAD ALCOHOL PREP PAD SWITCH HARNESS REVOLVER PCM COVER STICKER

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

HIGH PERFORMANCE FUEL DELIVERY KIT DUAL STOCK PUMP VERSION L & L

302+/303 Clamp Meter. Users Manual

A Member of the. Integrated Metering Technologies

AIR CHAMP PRODUCTS. User Manual. BW Clutch or Brake Sheave, Pilot and Coupling Mount FORM NO. L U-1209 FORM NO.

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

HighLuxV2-Zenigata Series

Care and use guide. Contents. page

SPC Series. Digital Scale. Operation Manual

USER MANUAL. Revision 1.0.1

Humidity Monitor model 00619

II DISTRIBUTION & SUBSTATION TYPE C

Installation Power Management Unit Battery Cables and Battery Harness


Transcription:

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410 OPERATION AND SERVICE MANUAL P/N 1980575, REV F FEBRUARY 2016

Copyright TSI Incorporated / 2007-2016 / All rights reserved. Address TSI Incorporated / 500 Cardigan Road / Shoreview, MN 55126 / USA Fax No. (651) 490-3824 Limitation Of Warranty And Liability (effective February 2015) (For country-specific terms and conditions outside of the USA, please visit www.tsi.com.) Seller warrants the goods, excluding software, sold hereunder, under normal use and service as described in the operator's manual, to be free from defects in workmanship and material for 24 months, or if less, the length of time specified in the operator's manual, from the date of shipment to the customer. This warranty period is inclusive of any statutory warranty. This limited warranty is subject to the following exclusions and exceptions: a. Hot-wire or hot-film sensors used with research anemometers, and certain other components when indicated in specifications, are warranted for 90 days from the date of shipment; b. Pumps are warranted for hours of operation as set forth in product or operator s manuals; c. Parts repaired or replaced as a result of repair services are warranted to be free from defects in workmanship and material, under normal use, for 90 days from the date of shipment; d. Seller does not provide any warranty on finished goods manufactured by others or on any fuses, batteries or other consumable materials. Only the original manufacturer's warranty applies; e. This warranty does not cover calibration requirements, and seller warrants only that the instrument or product is properly calibrated at the time of its manufacture. Instruments returned for calibration are not covered by this warranty; f. This warranty is VOID if the instrument is opened by anyone other than a factory authorized service center with the one exception where requirements set forth in the manual allow an operator to replace consumables or perform recommended cleaning; g. This warranty is VOID if the product has been misused, neglected, subjected to accidental or intentional damage, or is not properly installed, maintained, or cleaned according to the requirements of the manual.unless specifically authorized in a separate writing by Seller, Seller makes no warranty with respect to, and shall have no liability in connection with, goods which are incorporated into other products or equipment, or which are modified by any person other than Seller. The foregoing is IN LIEU OF all other warranties and is subject to the LIMITATIONS stated herein. NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE. WITH RESPECT TO SELLER S BREACH OF THE IMPLIED WARRANTY AGAINST INFRINGEMENT, SAID WARRANTY IS LIMITED TO CLAIMS OF DIRECT INFRINGEMENT AND EXCLUDES CLAIMS OF CONTRIBUTORY OR INDUCED INFRINGEMENTS. BUYER S EXCLUSIVE REMEDY SHALL BE THE RETURN OF THE PURCHASE PRICE DISCOUNTED FOR REASONABLE WEAR AND TEAR OR AT SELLER S OPTION REPLACEMENT OF THE GOODS WITH NON-INFRINGING GOODS. TO THE EXTENT PERMITTED BY LAW, THE EXCLUSIVE REMEDY OF THE USER OR BUYER, AND THE LIMIT OF SELLER'S LIABILITY FOR ANY AND ALL LOSSES, INJURIES, OR DAMAGES CONCERNING THE GOODS (INCLUDING CLAIMS BASED ON CONTRACT, NEGLIGENCE, TORT, STRICT LIABILITY OR OTHERWISE) SHALL BE THE RETURN OF GOODS TO SELLER AND THE REFUND OF THE PURCHASE PRICE, OR, AT THE OPTION OF SELLER, THE REPAIR OR i

REPLACEMENT OF THE GOODS. IN THE CASE OF SOFTWARE, SELLER WILL REPAIR OR REPLACE DEFECTIVE SOFTWARE OR IF UNABLE TO DO SO, WILL REFUND THE PURCHASE PRICE OF THE SOFTWARE. IN NO EVENT SHALL SELLER BE LIABLE FOR LOST PROFITS, BUSINESS INTERRUPTION, OR ANY SPECIAL, INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES. SELLER SHALL NOT BE RESPONSIBLE FOR INSTALLATION, DISMANTLING OR REINSTALLATION COSTS OR CHARGES. No Action, regardless of form, may be brought against Seller more than 12 months after a cause of action has accrued. The goods returned under warranty to Seller's factory shall be at Buyer's risk of loss, and will be returned, if at all, at Seller's risk of loss. Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY AND LIABILITY, which contains the complete and exclusive limited warranty of Seller. This LIMITATION OF WARRANTY AND LIABILITY may not be amended, modified or its terms waived, except by writing signed by an Officer of Seller. Service Policy Knowing that inoperative or defective instruments are as detrimental to TSI as they are to our customers, our service policy is designed to give prompt attention to any problems. If any malfunction is discovered, please contact your nearest sales office or representative, or call Customer Service department at +44 (0) 149 4 459200 (UK), (800) 874-2811 (USA), or (1) 651-490-2811 (International). ii

CONTENTS CHAPTER 1 UNPACKING AND PARTS IDENTIFICATION... 1 CHAPTER 2 SETTING-UP... 3 Supplying Power to the Alnor AVM410/Airflow Instruments TA410... 3 Installing the Batteries... 3 Using The Telescoping Probe... 3 Extending The Probe... 3 Retracting The Probe... 3 CHAPTER 3 OPERATION... 5 Keypad Functions... 5 CHAPTER 4 MAINTENANCE... 7 Recalibration... 7 Cases... 7 Storage... 7 CHAPTER 5 TROUBLESHOOTING... 9 APPENDIX A SPECIFICATIONS... 11 iii

iv (This page intentionally left blank)

Chapter 1 Unpacking and Parts Identification Carefully unpack the instrument and accessories from the shipping container. Check the individual parts against the list of components below. If anything is missing or damaged, notify TSI immediately. 1. Carrying case 2. Instrument 1

(This page intentionally left blank) 2 Chapter 1

Chapter 2 Setting-up Supplying Power to the Alnor AVM410/Airflow Instruments TA410 The Alnor AVM410/Airflow Instruments TA410 is powered with four size AA batteries. Installing the Batteries Insert four AA batteries as indicated by the diagram located on the inside of the battery compartment. The Alnor AVM410/Airflow Instruments TA410 is designed to operate with either alkaline or NiMH rechargeable batteries, although it will not recharge NiMH batteries. Battery life will be shorter if NiMH batteries are used. Carbon-zinc batteries are not recommended because of the danger of battery acid leakage. Using the Telescoping Probe The telescoping probe contains the velocity, temperature, and humidity sensors. When using the probe, make sure the sensor window is fully exposed and the orientation dimple is facing upstream. N o t e For temperature measurements, make sure that at least 3 inches (7.5 cm) of the probe is in the flow to allow the temperature sensor to be in the air stream. Extending the Probe To extend the probe, hold the handle in one hand while pulling on the probe tip with the other hand. Do not hold the cable while extending the probe as this prevents the probe from extending. Retracting the Probe To retract the probe, hold the handle in one hand while pulling gently on the probe cable with the other hand. 3

(This page intentionally left blank) 4 Chapter 2

Chapter 3 Operation Keypad Functions ON/OFF Key ft/min / m/s Key Press to turn the Alnor AVM410/Airflow Instruments TA410 on and off. During the power up sequence the display will show the following: Model Number, Serial Number, Software Revision, and Last Date Calibrated. Pressing this key changes the display to read air velocity. C / F Key Pressing this key changes the display to read temperature. Changing Units To change units, first put the desired measurement (air velocity or temperature) on the display. Then press and hold the left, unlabelled key for five seconds. Finally, use the and ENTER key to select the units. 5

(This page intentionally left blank) 6 Chapter 3

Chapter 4 Maintenance The Alnor AVM410/Airflow Instruments TA410 requires very little maintenance to keep it performing well. Recalibration To maintain a high degree of accuracy in your measurements, we recommend that you return your Alnor AVM410/Airflow Instruments TA410 to TSI for annual recalibration. Please contact one of TSI s offices or your local distributor to make service arrangements and to receive a Return Material Authorization (RMA) number. To fill out an online RMA form, visit TSI s website at http://service.tsi.com. U.S. & International UK TSI Incorporated TSI Instruments Ltd. Alnor Products Stirling Road 500 Cardigan Road Cressex Business Park Shoreview MN 55126-3996 High Wycombe Tel: (800) 874-2811 Bucks (651) 490-2811 HP12 3ST United Kingdom Fax: (651) 490-3824 Tel: +44 (0) 149 4 459200 Fax: +44 (0) 149 4 459700 Cases If the instrument case or storage case needs cleaning, wipe it off with a soft cloth and isopropyl alcohol or a mild detergent. Never immerse the Alnor AVM410/Airflow Instruments TA410. If the enclosure of the Alnor AVM410/Airflow Instruments TA410 becomes broken, it must be replaced immediately to prevent access to hazardous voltage. Storage Remove the batteries when storing the unit for more than one month to prevent damage due to battery leakage. 7

(This page intentionally left blank) 8 Chapter 4

Chapter 5 Troubleshooting Table 5-1 lists the symptoms, possible causes, and recommended solutions for common problems encountered with the Alnor AVM410/Airflow Instruments TA410. If your symptom is not listed, or if none of the solutions solves your problem, please contact TSI. Table 5-1: Troubleshooting the Alnor AVM410/Airflow Instruments TA410 Symptom Possible Causes Corrective Action No Display Unit not turned on Switch unit on. Low or dead batteries Replace batteries or plug in AC adapter. Dirty battery contacts Clean the battery contacts. Velocity reading fluctuates unstable Fluctuating flow Reposition probe in less-turbulent flow Instrument Error message appears Fault in instrument Factory service required on instrument. W A R N I N G! Remove the probe from excessive temperature immediately: excessive heat can damage the sensor. Operating temperature limits can be found in Appendix A, Specifications. 9

(This page intentionally left blank) 10 Chapter 5

Appendix A Specifications Specifications are subject to change without notice. Velocity: Range: Accuracy 1&2 : Resolution: Temperature: Range: Accuracy 3 : Resolution: 0 to 4000 ft/min (0 to 20 m/s) ±5% of reading or ±5 ft/min (±0.025 m/s), whichever is greater 1 ft/min (0.01 m/s) 0 to 200 F (-18 to 93 C) ±0.5 F (±0.3 C) 0.1 F (0.1 C) Instrument Temperature Range: Operating (Electronics): 40 to 113 F (5 to 45 C) Operating (Probe): 0 to 200 F (-18 to 93 C) Storage: -4 to 140 F (-20 to 60 C) Instrument Operating Conditions: Altitude up to 4000 meters Relative humidity up to 80% RH, non-condensing Pollution degree 1 in accordance with IEC 664 Transient over voltage category II External Meter Dimensions: 3.3 in. 7.0 in. 1.8 in. (8.4 cm 17.8 cm 4.4 cm) Meter Weight: Weight with batteries: 0.6 lbs (0.27 kg) Power Requirements: Four AA-size batteries (included) 1 2 3 Temperature compensated over an air temperature range of 40 to 150 F (5 to 65 C). The accuracy statement of ±5.0% of reading or ±5 ft/min (±0.025 m/s), whichever is greater, begins at 30 ft/min through 4000 ft/min (0.15 m/s through 20 m/s). Accuracy with instrument case at 77 F (25 C), add uncertainty of 0.05 F/ F (0.03 C/ C) for change in instrument temperature. 11

Alnor Products, TSI Incorporated Visit our website www.alnor.com for more information. USA Tel: +1 800 874 2811 India Tel: +91 80 67877200 China Tel: +86 10 8219 7688 Singapore Tel: +65 6595 6388 Airflow Instruments, TSI Instruments Ltd. Visit our website at www.airflowinstruments.co.uk for more information. UK Tel: +44 149 4 459200 France Tel: +33 1 41 19 21 99 Germany Tel: +49 241 523030 P/N 1980575 Rev.F 2016 TSI Incorporated Printed in U.S.A. *1980575*