GEF-4647A. GE Drive Systems. Renewal Parts. HEAVY DUTY DC CONTACTORS DS303Al (600V STYLE) DS303Bl (looov STYLE) www. ElectricalPartManuals.

Similar documents
RENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK

CD5--- CA4--- CD6---- CB2---- CB4---- PARTS RECOMMENDED FOR NORMAL STOCK

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS CR7006-C100, -C101 AND -C102 MAGNETIC STARTERS

www. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS

GENERAL. ELECTRIC RENEWAL PARTS IC302E HIGH VOLTAGE CONTACTORS. EA A-2300V IEl A-4800V l:c a-sooov

www. ElectricalPartManuals. com Type AM ,-6 Magne-Biast Circuit Breakers RENEWAL PARTS GENERAL. ELECTRIC GEF-4438A Supersedes GEF-4438

RENEWAL PARTS AK-2-15 AK-2-25 AK-3-25 AKF-2-25 AK-2A-15 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25

www. ElectricalPartManuals. com MAGNETIC TIME RELAYS GENERAL. ELECTRIC INSTRUCTIONS *IC *Also identified with prefix CR instead of IC.

SERVICE AND REPAIR PARTS NEMA SIZE 5, SINGLE POLE, NORMALLY CLOSED, P/N SERIES NEMA SIZE 5A, SINGLE POLE, NORMALLY CLOSED, P/N SERIES

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

SERVICE AND REPAIR PARTS NEMA SIZE 3, SINGLE POLE, NORMALLY OPEN, P/N SERIES NEMA SIZE 4, SINGLE POLE, NORMALLY OPEN, P/N SERIES

SERVICE AND REPAIR PARTS NEMA SIZE 5, SINGLE POLE, NORMALLY OPEN, P/N SERIES NEMA SIZE 5A, SINGLE POLE, NORMALLY OPEN, P/N SERIES

www. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC

Page 1 of 9 Knowledgebase Technote ID # Q /24/2006

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com

www. ElectricalPartManuals. com Cutler-Hammer Power Breaker Center Renewal Parts for Low Voltage Power Circuit Breakers Types DB, DBL and DBF

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS METAL-CLAD SWITCHGEAR TYPES M-26 AND M-36 GEF-4351C Supersedes GEF-4351B

Crane Control. Crane Control 1. Contents. Description Heavy-Duty Brakes Shoe Brakes Magnetically Operated Master and Limit Switch Family

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers

CR193 B,C,D and E Vacuum Limitamp * Contactors

Magnetic Overload Relays

OHIO MODELCDS AUTO/MANUAL DROP MAGNET CONTROLLER DESCRIPTION INSTALLATION PROCEDURES INSTALLATION, MAINTENANCE, AND PARTS BULLETIN

PAMPBLIT NUMBER U- 8474

DEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Series A Construction

US Brochure. R contactor Engineered to perform

www. ElectricalPartManuals. com It'll Cutler-Hammer WLI Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 1

Motor Controllers + Circuit Breakers

505 Size 5 Series A Construction

Euclid Full Voltage Magnet Controller

Crane Control Class 6131

TYPE KF UNDER-FREQUENCY RELAY A. Figure 1: Type KF Relay for 60 Hertz without Case. (Front & Rear View.) Front View Rear View

1370 DC Loop Contactors and Lug Kits

Enclosed Molded Case Circuit Breakers

Instructions for Replacing

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E

QUICK LOCATOR GUIDE. Button Components Key Switches and Keys

Product Information Packet SUM HP,1725RPM,3PH,60HZ,180TY,TENV,FOOTLES

FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION

SUL50306SM 3HP,1200RPM,1PH,60HZ,210TY,TENV,FOOTLES

Installation Sheet January, 2016 Supersedes February, 2013

OHIO MODEL RD-2A AUTO/MANUAL DROP MAGNET CONTROLLER INSTALLATION, MAINTENANCE, AND PARTS BULLETIN

DC Loop Contactors, Contactor Lugs and Dynamic Brakes Technical Data

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

P. Sub 4 184A404. Sub 3 876A220

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

Table 1d - FSA for All Returns, Females Tax Year

NEMA Vacuum Break Contactors and Starters

J lh. NEMA AC Contactors for Motor Loads (Bulletin 500) and Non-motor Loads (Bulletin 500L) Sizes 0 through 4 (all series), Size 5 (series L)

Contactors. Contactors ensure positive safety between their auxiliary contact blocks. Easy coil change Captive terminal screws

Type CRN-1 Reverse Power Relay 50 and 60 Hertz

Programmable Logic Controller. Mat Nor Mohamad

Ampgard medium voltage motor control renewal parts

ARMOR QUICK LOCATOR GUIDE. Belts , 380 Brake Components Brushes Capacitors Car Signal Components...

Product Selection 3-Pole Contactors

3 Pole, 27 Amp, Non-Reversing Across The Line Contactor With V Ac Coil and 1 No Auxiliary Contact

Bulletin 509 Three Phase Full Voltage NEMA Starters Size 00 (all series) Renewal Parts

Evolution * Series E9000 Motor Control Center

5H KA, RMS C/L Recommendations for Stock POLE UNIT PARTS ARC CHUTE DETAILS. Core, Fig. 17, It.

www. ElectricalPartManuals. com RENEWAL PARTS DATA Westinghouse Electric Corporation WESTINGHOUSE EQUIPMENT FOR FURNISHED TO

B CW POWER RELAY

TABLE I 60 CYCLE BURDEN OF THE CVD RELAY AT CONTINUOUS RATING

INSTRUMENT PANEL CLUSTERS

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

Installation Sheet January, 2016 Supersedes June 2013

Tamil Nadu Public Service Commission

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay


F1-1 ACCESSORIES AND SPARE PARTS FOR DRIWISA EQUIPMENTS INDOOR SERVICE OVERVIEW DRIESCHER Y WITTJOHANN, S.A.

PoweMr' With 18 Mechanism '. 1 . / ,, ( c :11t

Illustrated Parts List for GPU-400

AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)

Switches Unlimited Phone: * Fax:

T O C Car Signal Components Coils Door Equipment Key Switches Safety Edge Equipment Door Operator Equipment GAL Relay Parts Wheels

www. ElectricalPartManuals. com

CR193 Vacuum Limitamp* Contactors

Crane Control Class 5010

EDS / EFS Series Control Stations

Model 10 Crossing Signal

Micro Contactor MA Series

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E

920 Remote Control Switches

~

Bussmann series Quik-Spec Power Module Switch elevator disconnect

System pro M compact Miniature Circuit Br eakers Description Features

CM52 Network protector

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

HGA. Hinged Armature Auxiliary. Hinged armature auxiliary relay to perform auxiliary functions in AC and DC circuits.

Control Transformers

EDS / EFS Series Control Stations

WLI Medium Voltage Switchgear Renewal Parts

COM Overcurrent Relay

Transcription:

GEF4647A GE Drive Systems Renewal Parts HEAVY DUTY DC CONTACTORS DS303Al (600V STYLE) DS303Bl (looov STYLE)

DS303 A 1 A 01 A B c AF 11A TABLE 1 NAMEPLATE DENTFCATON OF CONTACT A 1 Normally open POLE CONFGURATON B 1 Normally closed D 1 Normally open and 1 normally closed G 1 Normally closed with holding coil J 1 Normally open and 1 normally closed with holding coil Quantity Required for L Special setting and stamping Electric interlock (See Table 4) Operating coil and voltage rating (See Table 3) Normally closed blowout coil rating 1 or 2 poles bottom (See Table 2) Normally open blowout coil rating 1 or 2 poles top (See Table 2) Electromechanical configuration Contact pole configuration (See Table 1) NEMA size rating (25 amps) Design (A = 600V, B = looov) B.1Sic catalog number TABLE 2 BLOWOUT COLS See nameplate reading above Blowout Current Co1l Coil Rating Ref. No. 1 Letter PARTS RECOMMENDED FOR STOCK A Less B.O. B 2amp 259A8153G3 c 5 amp 259A8153G2 D 10 amp 259A8153G1 E* 25 amp 259A5686P2 X Pole Eliminated Order 1nsulat1on tube cat. no. 259A5643P2 and qty. 2 insulation spacers 259A5688P1. Ref. 1 N.O. 1 N.C. 1 N.O. Catalog Description No. 1 N.C. Number 2 Operating co1l (see table 3) 3 Holding coil (see table 3) 4 # # # Electncal interlock (see table 4) 10 1 2417924P1 Tens1on spring for armature 10 1 1 2418822P1 Tension spring for armature 19 1 1 2 259A5615G1 StatiOnary tip assembly 30 1 1 2 195B6285G3 Arc chute assembly 31 1 1 2 259A5614G1 Movable tip assembly 33 1 2 304A6611P1 Compress1on spnng for movable contact finger (used With holding COil) 33 1 1 304A6611P1 Compress1on spnng for movable contact finger (used without holding co1l) 33 1 1 2418819P1 Compress1on spring for movable contact finger (used 37 without holding co1l) 1 259A5683G1 Shunt assembly 37 1 2 259A8160G1 Shunt assembly # f mterlock 1s used. a quantity of one set S requ1red for each nterlock. 1

GEF4647A 6 ill 5 +iiih 2+* DS303A1 HEAVY DUTY DC CONTACTORS 34 '' 33 4032 9 HH 37 17 13 5 3 35 20 24 19 23 1 21 11 10 i!, ' i! :1..! ' i '. 'J C""l 1/l u ' 22 18 25 DS303A 1 N.O. Contact DS303A 1 N.C. Contact 41 i30 0 ) 2 41 39 32. ; 19 20 31 14 18 30 15 18

DS303A1 HEAVY DUTY DC CONTACTORS Ref. No. LST OF PARTS Quantity Required for Catalog 1 N.O. 1 N.C. 1 N.O. Number Description 1 N.C. 1 Blowout coil (see table 2) 2 Operating coil (see table 3) 3 Holding coil (see table 3) 4* Electrical interlock (see table 4) 5 1 1 1 N931 P50C6 Coil retainer 6 1 1 1 151 A3966P1 Washer for operating or holding coil 7 1 202B3632G1 Magnet frame with core for operating coil 7 1 1 237B7702G1 Magnet frame with core for operating coil and holding coil 9 1 259A5681G1 Armature assembly 9 1 1 259A8164G1 Armature assembly 10 1 241 7924P1 Tension spring for armature 10 1 1 241 8822P1 Tension spring for armature 11 1 161 A7368G7 Spring support 12 1 1 181 A4841P2 Armature stop 13 2 2 N144P15006C6 Screw with lock washer fastening support to armature 14 1 1 202B3636G1 Terminal block 15 1 1 9023691P1 Adjusting screw for tension spring 16 1 1 8650775P5 Supporting bracket for terminal block 17 GEF4647A 2 2 N144P1 3006C6 Screw with lock washer fastening upper magnet to lower magnet frame 18 2 3 4 N144P1601 0C6 Screw with lock washer fastening terminal block to supporting bracket 19 1 1 2 259A5615G1 Stationary tip assembly 20 1 1 2 9384190P1 Screw with lock washer fastening stationary tip to support 21 1 1 2 259A5690P1 Terminal 22 1 1 2 N144P21 008C6 Terminal screwwith lock washer 23 1 1 2 259A5685G1 Blowout coil and terminal support 24 1 1 2 N144P1 6008C6 Screw with lock washer fastening terminal to support 25 1 259A6597G1 Terminal support 26 1 1 2 259A5687P1 Arc horn for stationary tip 27 1 1 2 259A5689G1 Pole piece with core 28 1 1 2 305A1210G1 Pole piece 29 1 1 2 N51P1 6008B6 Screw fastening pole pieces together 30 1 1 2 195B6285G3 Arc chute assembly 31 1 1 2 259A5614G1 movable t1p assembly 32 1 202B2627G2 Movable t1p assembly (complete) N.O. 32 1 202B3638G2 Movable tip assembly (complete) N.O. 32 1 1 202B3638G6 Movable tip assembly (complete) N.C. 33 1 2 304A661 1P1 Compression spnng for movable contact finger (used w1th holding COil) 33 1 1 1 304A661 1P1 Compress1on spnng for movable contact finger (used w1thout holding co1l) 33 1 2418819P1 Compress1on spnng for movable contact finger (used without holding co1l) 34 1 1 2 259A5684P1 Spnng support 35 1 1 2 259A5682G1 Movable lip support 36* 2 2 4 N144P1 3004C6 Screw w1th lock washer fastening spnng support to molded support 37 1 259A5683G1 Shunt ass mbly 37 1 1 259A81 60G1 Shunt assembly 38* 1 1 2 259A8165P1 Arc Barner 39 1 259A5695P1 Arc support 39 1 2 259A8161P1 Arc support 40 1 259A8156P2 Spacer 41 1 1 2 273A4945P1 nsulation (1 000 volt form only) Not shown 3

GEF4647A Coil No. Volts A002 230/250 A003 115/120 A004 475/500 A005 550 A006 600 A008 12 A009. 5/20 A010 24 A012 32 A013 38 A014 48/50 A015 55/60 A016 62/68 A017 74 A018 78 A019 80 A020 90 A021 100 A023 150 A025 180/190 A027 275 A028 300 A029 350 A031 440 A032 13.6 A502* 230/250 A503* 115/120 A650 A651 A652 A653 115AC 230AC 460AC 575AC 8002 230/250 8013 38 C013 38 C019 80 J202 230/250 J203 115/120 J204 90 J205 62 J206 90 J207 115/120 J208 230/250 J209 150 J210 125 i Operating Coil TABLE 3 OPERATNG AND HOLDNG COLS See nameplate reading on page 1 Volts Holding Coil 1D106G3A 1D106G12A 10106G30A 1D106G18A 1D106G10A 1D106G93A 1D106G14A 1D106G43A 1D106G9A 1D.106G7A 1D106G7A 1D106G7A 1D106G7A 1D106G94A 1D106G8A 1D106G42A 10106G2A 1D106G54A 1D106G3A 1D106G7A 1D106G42A 1D106G44 1D106G38A 1D106G51A 1D106G50A 10106G2A 230/250 10106G2A 1D106G3A 115/120 10106G3A 10106G13A 10106G9A 62 10106G9A 10106G13A 90 10106G13A 10106G3A 90 10106G13A 10106G2A 115/120 10106G3A 10106G8A 150 10106G8A 10106G41A 250 10106G40A *Order no1se suppressor cat. no. 128C4095G21 for DS303A1A Order no1se suppressor cat. no. 128C4095G22 for DS303A18 Order no1se suppressor cat. no. 128C4095G22 for DS303A10 1 N.O. contact 1 N.C. contact 1 N.O. 1 N.C. contact 4 DS303A1 H.'.:'Y DUTY DC CONTACTORS Pickup Resistor A50E4000DATH A50E4000DATH A50E6000DATH A50E 1 OOODATH A50E 1500DATH A50E2000DATH A50E3000DATH A50E200DATH A50E500DATH A50E4000DATH A50E6500DATH Rec it er C3500A403C2 C3500A403C6 C3500A403C5 C3500A403C8

DS303A 1 HEAVY DUTY DC CONTACTORS nterlock Letter XF XG XH XJ XK XL AF AG AH AJ AK AL OF OG OH OJ OK OL EF EG EH EJ EK EL nterlock Switch Unit TABLE 4 ELECTRCAL NTERLOCK See nameplate reading on page 1 Lefthand Righthand # Set of Contacts C2956A200A C2956A200A C2956A200C C2956A200C C2956A200B C2956A200B C2956A200A C2956A200A C2956A200C C2956A200C C2956A200B C2956A200B C2956A205A C2956A205A C2956A205C C2956A205C C2956A205B C2956A205B C2956A205A C2956A205A C2956A205C C2956A205C C2956A205B C2956A205B # ncludes movable and stat1onary contacts. spnngs. and contacthold1ng screws. 5 Mounfir'lg Kit nterlock Cover GEF4647A

f

11\U,,S.A. Drive Systems Operations Salem, Vrrgmia 24153 1501 Roanoke Boulevard (703) 3877000 11187