Personal ph, ph/orp, Conductivity Meters

Similar documents
User s Manual. Model PH72 Personal ph/orp Meter IM 12B03D02-01E. IM 12B03D02-01E 3rd Edition

User s Manual. Model PH71 Personal ph Meter IM 12B03D01-01E. IM 12B03D01-01E 3rd Edition

General Specifications

General Specifications

General Specifications

Conductivity Measurement CLM 280

General Specifications

CPM280. Technical Information. ph/orp measurement Battery-driven pocket meter for ph and ORP measurement

General Specifications

General Specifications

General Specifications

ortable ph, Conductivity & DO2 Meters

General Specifications

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Instruction Manual. Model SC4A 19mm Conductivity Sensors. IM 12D7J4-E-E 6th edition YOKOGAWA

General Specifications

Signet ph/orp Electrodes

Signet 2760 DryLoc ph/orp Preamplifiers & Connectors

Vortex Flowmeter. digitalyewflo. Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Instruction Manual. Models FD30 / PB30. Fittings for the DO30G. IM 12J06K04-E-E 6th edition

General Specifications

General Specifications

Main material GFRPP IWAKI MAGNETIC DRIVE PUMPS

ECscan30 Pocket Conductivity/TDS Tester Instruction Manual

Model OR8ERG KCl Refillable type ORP Sensor

User s Manual Model PH10RP KCl Replenish-free ph Sensor

Manifolds for DPHarp EJA and EJX Pressure and Differential Pressure Transmitters. Pressure psi (bar) (860) (552) (413) 4.

Model OR8ERG KCl Refillable type ORP Sensor

General Specifications

Model PH87 Retraction Sensor Assembly

General Specifications

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006

Magnetic drive pumps A worldwide best-seller, our high-quality compact magnetic drive pumps

Signet ph/orp Electrodes

Dräger X-am 5100 Single-Gas Detection Device

General Purpose ph/orp Sensors

Magnetic drive pumps. A worldwide best-seller, our high-quality compact magnetic drive pumps GFRPP. Magnetic drive pumps. series.

ECscan40 Pocket Conductivity/TDS/Salinity Tester Instruction Manual

Signet 3719 ph/orp Wet-Tap

Signet ph/orp Electrodes

Digital ph transmitter

Instruction Manual. ph Meter D-51

testo 338 Portable Soot and Particulate Meter Versatile, digital display of particulates

General Specifications

Instruction Manual Portamess 911 Cond

Signet DryLoc ph/orp Electrodes

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Insertion/Submersion Flow Through Sensor

Instrumentation Manifolds Traditional C13WT series. For DPharp EJX & EJA-E Differential Pressure and Pressure Transmitters

Signet DryLoc ph/orp Electrodes

ph/orp Sensor Model 399 ph/orp

Operation Manual MODEL EC331. Microcomputer Based Conductivity /Resistivity & Temperature Pocket Meter EC331

Signet 2760 DryLoc ph/orp Preamplifier

General Specifications

Bante220 Portable ph Meter Instruction Manual

* * Rev. 9 01/18 Product Manual

General Specifications

Digital ph transmitter

NEW QUICK CABLE-TO-SENSOR RELEASE,

Model PH8EHP ph Sensor for High Purity Water

General Purpose ph/orp Sensors

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Signet Conductivity/Resistivity Electrodes

A6 type. General universal type. Submerged type Connector box type. Installation method Titanium PPS FKM

User s Manual. PH4/OR4 Sensor Series ph and ORP Sensors IM 12B10B00-01EN IM 12B10B00-01EN. 7th Edition

TDSscan10M Pocket TDS Tester Instruction Manual

Variable V Area Flowmeter Rotameter The Original

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008

ECscan20 Pocket Conductivity Tester Instruction Manual

CRES. RoD Actuator. Low-cost and handy actuator Dustproof and waterproof design compliant with IP55 standard Compliant with the RoHS Directives

Model PH8ERP KCl Refillable type ph Sensor

Ceraliquid CPS42/CPS42D/CPS43

Signet 3719 ph/orp Wet-Tap Assembly

Bourns SinglFuse. Thin Film Chip Fuse. Short Form Brochure

VersaFlow Mag 3000 Electromagnetic Flow Sensor Technical Datasheet. Specification

MCF3 25CT Inrush-withstand

PH60 Series Premium ph Testers

Portable Clamp Force Indicator

Switch Mode Power Supply S8JC-Z / S8JC-ZS / S8JX-G / S8JX-P / S8VK-G / S8VK-C. Power Supply Selection Guide

Portable Digital Clamp Force Indicator

Inductive conductivity meter

8000 Series Liquid Flow Meter

Signet Conductivity/Resistivity Electrodes

Orbipore CPS91 and CPS91D

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013

General Specifications

Metso Conductivity for sensor series 9400 and 9500

MCF3 DC86V11CT Inrush-withstand

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

8000 Series Liquid Flow Meters

Tube: End-cap: Core: Solder: Lead-free glass Nickel plated brass Ceramic Sn-1.5Cu. Pb87.5-Sn10-Ag2.5* ma less than 1 A.

Models 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor

3. Operating instructions: Minor 200

Conductivity Measuring Cells ConduMax W CLS 19

Lead-free glass Nickel plated brass 62 ma 1.25 A Over 1.25 A 3 A Epoxy resin 62 ma less than 1 A. Tube: End-cap: Solder: Adhesive: Marking: 1 A 3 A

ELPRO Lepenik & Co. d.o.o., Ob gozdu 7c, Rogoza, 2204 Miklavž na Dravskem polju, Slovenija tel:

Fork through-beam sensors

COM-100 EC / TDS / TEMPERATURE METER

AGUABEL. Index. Aguapure Aguapure Lara APS 3. P-Pump 4. Aspendose 5. Tank for chemical 6. Tank with mixer 6. Glass Sensor 7.

Transcription:

Personal ph, ph/orp, Meters // Personal ph, ph/orp, Meters Bulletin 12B03D01-01E www.yokogawa.com/an/

Compact and lightweight 220g IP67 Waterproof CE,RCM,KC Various Convenient Data memory Alarm Clock Date/time display switchable Self-diagnostics Auto power off Personal Series SN YOKOGAWA is a pioneer in the design and development of portable water quality meters. Bodies of the Personal Series are tough, waterproof (IP67) and stylish design with bright new colors. Advanced yet easy-to-use membrane keypad for various and convenient function such as data memory.

Personal Series are ideal for testing waters outside, laboratory studies, and various other applications. Dimension, Personal ph, ph/orp Meter connector for Personal Meter connector for 11 11 PH/ORP Meter Aut Power Off POWER 0 POWER 0 MEAS MEAS CA HOD HOD F/ENT F/ENT Tough and waterproof construction Conforms to IP67 arge and easy-to-read CD display arge characters Compact and lightweight Fits comfortably your hand and stands firm on the table Features ineup of various sensors EMI(Emission) - EN 61326-1 Class B EMS(Immunity) - EN 61326-1 Table 2 (For use in industrial locations) DATA 61 ph for Personal ph, ph/orp Meter KCl replenish-free type ph sensor KCl refillable type ph sensor Needle type ph sensor 3000 3000 DATA 61 for Personal Meter for high purity water measurement General-purpose type sensor 3000 1 66 (67) 66 (67) 66 47 110 66 172 66 (67) 2 79 73 3 Test tube size ph sensor ORP for Personal ph/orp Meter 24 Chemical-resistant type sensor for high conductivity measurement 4 KCl refillable type ORP sensor 5 6 3000 Simple to Use 1 Remaining battery life at a glance ong battery life: 3 Power on/off key Auto power off function 6 Entry keys 200 hours of continuous 4 Easy calibration use () calibration 600 hours of continuous use (/72) 5 HOD key 7 DATA key 2 arge and easy-to-read CD Holds the displayed measured display value temporarily arge characters 7 For data setting, range setting, temperature compensation setting, standard solution calibration, cell constant setting (), etc. Gives access to 300 data points (measured values, temperature, date and time) 66 ø8 47 185 66 (67) 66 50 72 66 62 72

, Codes and Specifications Personal ph Meter ph sensors abel language *1: Needle type ph sensor and Test tube size ph sensor; Non-RoHS compliant products *2: In South Korea and Malaysia, primary battery is limited by regulations. Prepare batteries with the authorized certification mark for each country. Personal ph/orp Meter s abel language ORP s for ph/orp Meter Suffix Code OR72SN * 1-43 -48 * 2-49 * 2 *1: Cannot be connected to PH81 and meters *2: Combination of ORP sensors for PH81/82 meter with meter will not be IP67 waterproof. Specifications of Personal ph/orp Meters Measurement Measurement range Resolution Repeatability (w/o sensor) Display Indication Temperature compensation Calibration Ambient temperature Construction Weight Power source Battery life -32 * 1-33 * 1-32 * 1-33 * 1-43 -51 ph s for Personal ph/orp Meter Suffix Code Option Code -18 * 1-19 * 1 - * 1-32 * 2-33 * 2-38 * 1 * 2-39 * 1 * 2 Always *1: Combination of ph sensors for PH81/82 meter with /72 meter will not be IP67 waterproof. *2: Needle type ph sensor and Test tube size ph sensor; Non-RoHS compliant products Option Code Hydrogen ion concentration (ph) of solution, 0 to 80 C (or 0 to 100 C* 1 ) 0.01 ph, 0.1 C ±0.01 ph ±1 digit Digital CD ph and solution temperature (simultaneously), sensor check, various messages* 3 Automatic (1 or 2 point), manual 220 g (without sensor) 2 AA size dry cell batteries 600 hours* 2, Auto Power Off function Data memory (300 points), alarm clock, etc. *1: When needle type or test tube size ph sensor is connected. *2: When alkaline dry cell batteries are used. *3: When needle type or test tube size ph sensor is connected, liquid temperature can not be measured. Note: of sample solution must be at least 50 µs/cm. Personal ph meter With KCl replenish-free type combination ph sensor (cable length: 0.75 m) With KCl replenish-free type combination ph sensor (cable length: 3 m) With KCl refillable type combination ph sensor (cable length: 3 m) With needle type ph sensor (cable length: 0.75 m) With test tube size ph sensor (cable length: 0.75 m) South Korea and Malaysia (without batteries) * 2 Personal ph/orp meter With KCl replenish-free type combination ph sensor (cable length: 0.75 m) With KCl replenish-free type combination ph sensor (cable length: 3 m) With KCl refillable type combination ph sensor (cable length: 3 m) With needle type ph sensor (cable length: 0.75 m) With test tube size ph sensor (cable length: 0.75 m) With KCl refillable type ORP sensor (cable length: 0.75 m) With KCl refillable type ORP sensor (cable length: 3 m) + KCl refillable type ORP sensor (cable length: 0.75 m) South Korea and Malaysia (without batteries) * 2 *1: Needle type ph sensor and Test tube size ph sensor; Non-RoHS compliant products *2: In South Korea and Malaysia, primary battery is limited by regulations. Prepare batteries with the authorized certification mark for each country. Description ph sensor for personal ph/orp meter For /72: KCl replenish-free type combination ph sensor (cable length: 0.75 m) For /72: KCl replenish-free type combination ph sensor (cable length: 3 m) For PH81/82: KCl replenish-free type combination ph sensor (cable length: 0.75 m) For PH81/82: KCl replenish-free type combination ph sensor (cable length: 3 m) For /72: KCl refillable type combination ph sensor (cable length: 0.75 m) For /72: KCl refillable type combination ph sensor (cable length: 3 m) For PH81/82: KCl refillable type combination ph sensor (cable length: 0.75 m) For /72: Needle type ph sensor (cable length: 0.75 m) For /72: Test tube size ph sensor (cable length: 0.75 m) For PH82: Needle type ph sensor (cable length: 0.75 m) For PH82: Test tube size ph sensor (cable length: 0.75 m) Description ORP sensor for personal ph/orp meter For : KCl refillable ORP sensor (cable length: 0.75 m) For : KCl refillable ORP sensor (cable length: 3 m) For PH82: KCl refillable ORP sensor (cable length: 0.75 m) For PH82: KCl refillable ORP sensor (cable length: 3 m) Always Hydrogen ion concentration (ph) or oxidation-reduction potential (ORP) of solution, ±2000 mv, 0 to 80 C (or 0 to 100 C* 1 ) 0.01 ph, 1 mv (0.1 mv for -199.9 mv to 199.9 mv), 0.1 C ±0.01 ph ±1 digit, ±1 mv ±1 digit Digital CD ph or ORP (mv) and solution temperature (simultaneously), sensor check, various messages* 3 Automatic (1 or 2 point), manual 220 g (without sensor) 2 AA size dry cell batteries 600 hours* 2, Auto Power Off function Data memory (300 points), alarm clock, etc. Standard Accessories for Personal ph/orp Meter (for a set of converter and sensor) AA size dry batteries (2pcs) (for South Korea and Malaysia, batteries are not attached), User's Manual, Quick Manual, non-slip pads (2 pcs), hand strap * Standard solutions (ph 4, ph 7), calibration ation sub bottles (2 pcs), 3.3 mol/l KCl solution, 5-ml syringe, and cotton swabs are supplied depending on specifications. Specifications of s for Personal ph/orp Meter KCl replenish-free type combination ph sensor KCl refillable type combination ph sensor KCl refillable type ORP sensor Needle type ph sensor Test tube size ph sensor Personal Meter Measurement Range Wetted Material (0.75 m) (3 m) (0.75 m) (3 m) OR72SN (0.75 m) OR72SN-43 (3 m) -32 (0.75 m) -33 (0.75 m) ±2000 mv ±2000 mv Polypropylene resin (sensor body, protective cover) Glass (glass electrode, temperature sensor protection tube) Ceramics (liquid junction) Silicon rubber (sensor seal) ORP sensor: Platinum (electrode) KCl replenish-free type: PVC (cable), rigid polyethylene (grip), ethylene propylene rubber (grip and cable connection) Glass (sensor body) Glass (sensor body) sensors -31 Personal conductivity meter With sensor for high purity water measurement (cable length: 0.75 m) With general-purpose type sensor (cable length: 0.75 m) With general-purpose type sensor (cable length: 3 m) With chemical-resistant type sensor (cable length: 0.75 m) With sensor for high conductivity measurement (cable length: 0.75 m) abel language South Korea and Malaysia (without batteries) * 1 *1: In South Korea and Malaysia, primary battery is limited by regulations. Prepare batteries with the authorized certification mark for each country. for Personal Meter SN -19 * -29 * -31-39 * -49 * *Combination of conductivity sensor for SC82 with meter will not be IP67 waterproof. sensor for personal conductivity meter For : for high purity water measurement (cable length: 0.75 m) For SC82: for high purity water measurement (cable length: 0.75 m) For : General-purpose type sensor (cable length: 0.75 m) For : General-purpose type sensor (cable length: 3 m) For SC82: General-purpose type sensor (cable length: 0.75 m) For : Chemical-resistant type sensor (cable length: 0.75 m) For SC82: Chemical-resistant type sensor (cable length: 0.75 m) For : for high conductivity measurement (cable length: 0.75 m) For SC82: for high conductivity measurement (cable length: 0.75 m) Always Specifications of Personal Meter Measurement Unit Measurement range Resolution Repeatability Display Resistivity Temperature Resistivity Temperature of solution S/cm or S/m 0 to 2 µs/cm through 0 to 2 S/cm(depends on sensor to be used) 0 to 40.0 MΩ cm (for sensor for high purity water measurement) * 1 0 to 80 C 0.05% of full scale * 2 0.1 MΩ cm 0.1 C ±2% (±5% when general-purpose type sensor is used in the range of 0 to 200 ms/cm) Digital CD Indication Range switching Temperature compensation Ambient temperature Construction Weight Power source Battery life or resistivity, solution temperature and temperature coefficient (simultaneously), various messages Temperature coefficient (0 to 9.99%/ C) or NaCl coefficient, reference temperature at 25 C 220 g (without sensor) 2 size AA dry cell batteries 200 hours* 3, Auto Power Off function Data memory (300 points), alarm clock *1: Resistivity can be measured for reference. In that case repeatability is determined by conductivity. *2: When measuring range is set to full scale. *3: When alkaline dry cell batteries are used. Standard Accessories for Personal Meter AA size dry batteries (2pcs) (for South Korea and Malaysia, batteries are not attached), User's Manual, Quick Manual, non-slip pads (2 pcs), hand strap, cotton swabs

Specifications of for Personal Meter Measurement Range* 1 Cell Constant For high purity water measurement* 2 SN(0.75m) 0 to 2µS/cm, 0 to 20µS/cm, 0 to 200µS/cm, 0 to 40MΩ cm 0.05cm -1 General-purpose type SN(0.75m) SN (3m) 0 to 20µS/cm, 0 to 200µS/cm, 0 to 2mS/cm, 0 to 20mS/cm, 0 to 200mS/cm 5cm -1 Chemical-resistant type For high conductivity measurement SN-31(0.75m) SN(0.75m) 0 to 2mS/cm, 0 to 20mS/cm, 0 to 200mS/cm, 0 to 2S/cm *1: Fixed range. For automatic range, range is automatically variable. *2: Resistivity can be measured for reference. In that case repeatability is determined by conductivity. 50cm -1 Wetted Material SUS316 (electrode element), fluoro rubber (O-ring), polypropylene resin (insulated area), PVC (cable) Titanium (sensor), fluoro rubber (O-ring), PVC (cable), polyphenylene sulfite resin, polypropylene resin (insulated area, clear cover) Glass, platinum black (electrode element), PVC (cable) Glass, platinum black (electrode element), PVC (cable) Options (Available Separately) For conductivity meter Standard solution (0.1 mol /l NaCl, 250 ml) K9221ZA Spare Parts For ph/orp meter For ph and conductivity meters in common ph 4 standard solution ph 7 standard solution ph 9 standard solution KCl solution (3.3 mol/l) Quinhydrone reagent Calibration sub bottle set O-ring and gasket set K9084KF K9084KG K9084KH K9220XH K9024EC K9220WW K9220ZY K9654AY 3.3 mol/l KCl solution, 50 ml x 2 bottles 3 packs, 1 pack for 250 ml solution 2 bottles protective cover and cap Gaskets for battery box (2 pcs) and O-rings for connector (2 pcs) Personal meter IP67 CE * 1 RCM KC ph meter without sensor, ph/orp meter without sensor ph sensor - * 2 ORP sensor - meter without sensor sensor - *1: ph, ph/orp and meters and sensors; RoHS compliant products from Style code 2 *2: Needle type ph sensor and Test tube size ph sensor; Non-RoHS compliant products YOKOGAWA EECTRIC CORPORATION World Headquarters 9-32 Nakacho 2-chome, Musashino-shi, Tokyo 180-8750, JAPAN Tel: +81-2-52-6316 Fax: +81-2-52-6619 http://www.yokogawa.com/an/ North America YOKOGAWA CORPORATION OF AMERICA Georgia, U.S.A http://www.yokogawa.com/us/ South America YOKOGAWA AMERICA DO SU TDA. BRAZI http://www.yokogawa.com.br/ Europe YOKOGAWA EUROPE B.V. European Headquarters THE NETHERANDS http://www.yokogawa.com/eu/ YOKOGAWA EECTRIC CIS TD. RUSSIAN FEDERATION http://www.yokogawa.ru/ Middle East YOKOGAWA MIDDE EAST B.S.C.(C) http://www.yokogawa.com/bh/ Singapore YOKOGAWA ENGINEERING ASIA PTE.TD. http://www.yokogawa.com/sg/ Korea YOKOGAWA EECTRIC KOREA CO., TD. http://www.yokogawa.com/kr/ China YOKOGAWA CHINA CO., TD. http://www.yokogawa.com/cn/ YOKOGAWA SHANGHAI INSTRUMENTATION CO., TD. http://www.ysi.com.cn/ YOKOGAWA SICHUAN INSTRUMENT CO., TD. http://www.cys.com.cn/ Taiwan YOKOGAWA TAIWAN CORPORATION http://www.yokogawa.com.tw/ India YOKOGAWA INDIA TD. http://www.yokogawa.com/in/ Australia YOKOGAWA AUSTRAIA PTY. TD. http://www.yokogawa.com/au/ Represented by: Vig-PMK-G N-10E Printed in Japan, 603(KP) [Ed : 05/b] Subject to change without notice. All Rights Reserved, Copyright 2004, Yokogawa Electric Corporation.