Installation Operation Parts

Similar documents
MODEL H INSTALLATION INSTRUCTIONS

SEARS CRRFTSMRN" BATTERY OPERATED BACKUP SUMP PUMP OWNER'S MANUAL. Model No Operation Installation Troubleshooting

STEP-BY-STEP INSTALLATION GUIDE

INSTALLATION & OPERATION MANUAL

Pro Series C11. Combination Primary and Backup Sump Pump System. Instruction Manual & Safety Warnings. Table of Contents

OWNER S MANUAL. INSTALLATION AND OPERATION INSTRUCTIONS FOR 12 VOLT BATTERY BACK-UP SYSTEM Models: 92900, 92910

Battery Backup Sump Pump System Instruction Manual

Pro Series C22. Combination Primary and Backup Sump Pump System. Instruction Manual & Safety Warnings. Table of Contents

Battery Backup Sump Pump System

Battery Backup Sump Pump System

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

A/C-D/C Battery Backup Sump Pump System

Battery Backup Sump Pump System

SUBMERSIBLE SUMP PUMPS

Battery Backup Sump Pump System

ESE Series Cast Iron Sewage Pumps

SUBMERSIBLE SUMP PUMPS

Pro Series C33. Combination Primary and Backup Sump Pump System. Instruction Manual & Safety Warnings. Table of Contents

A/C-D/C Battery Backup Sump Pump System

10 AMP ON BOARD BATTERY CHARGER

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

Battery Backup Sump Pump System

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

User s Manual. Automatic Switch-Mode Battery Charger

Combination Primary and Backup Sump Pump System

Combination Primary and Backup Sump Pump System

Combination Primary and Backup Sump Pump System

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS

A/C-D/C Battery Backup Sump Pump System

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

Instruction Manual. Computer Controlled A/C - D/C Sump Pump System

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS Ext. 322

Submersible Effluent Pump

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

2603 Battery Pal 3 AMP, 1 2 VOLT BATTERY CHARGER

A/C-D/C Battery Backup Sump Pump System

LESTRONIC II BATTERY CHARGER MODEL 07210

PUMP SPY INSTALLATION AND OPERATING INSTRUCTIONS

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Model: SE-4020-CA Automatic Battery Charger

PRE-PLUMBED SEWAGE SYSTEM

Cruising Charger Series OWNER S MANUAL

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

M-3025CB-AV Fuel Pump

Battery. Charger Model: Save Important Safety Instructions

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

Model: PI-140 Power Inverter Converts 12V DC battery power to 120V AC household power

Safety, Installation And Operating Instructions For The Following Battery Charger Models: i2412, i3612, i4809, i2425, i3625, and i4818

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

GeyserMax-Flow Series

LAWN SPRINKLER, IRRIGATION PUMP

36 VOLT AUTOMATIC BATTERY CHARGER PART NO

OWNER S MANUAL PORTABLE POWER COMPACT & ROBUST

PSJ-2212, PSJ-3612, PSJ-4424

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

SAVE THESE INSTRUCTIONS

SuperFlo 9,000 High Volume Pump Product Manual

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

StormPro BA Series Sump Pump

Matala. VersiFlow Series. Instruction and Maintenance Manual

POWER TO GET THE JOB DONE

Owner s Manual Drill and Light Weight Portable Utility Pumps

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

QuickBoost Instruction Manual

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

12 amp RMS Battery Charger

OPERATOR S MANUAL JUMP STARTER. and DC Power Source. Model No CAUTION: Sears, Roebuck and Co., Hoffman Estates, IL U.S.A.

CRAFTSMAN+ PEDESTAL SUMP PUMP OWNER'S MANUAL. Model No Operation Installation Service

StormPro BCV400 Sewage Ejector Pump

IMPORTANT SAFETY INSTRUCTIONS

OBE, OBEXU, ON BOARD Battery Chargers

HALLMARK INDUSTRIES INC

Matson Jump Starter Operator s Manual

LESTRONIC II BATTERY CHARGER MODEL 19740

Turbo M Series onboard charger

JUMP STARTER OPERATOR S MANUAL RA1900

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

Car Battery Charger Instructions for Use

FULLY AUTOMATIC SCR BATTERY CHARGER

QSSE, QSSEX INDUSTRIAL Battery Chargers

600 Amp Battery Jumper with Air Compressor

OBAE, OBAEXU, ON BOARD Battery Chargers

Intelligent Charging System Series

MODEL 585 BATTERY BACKUP PEDESTAL SUMP PUMP PREINSTALLATION CHECKLIST SEE BELOW FOR LIST OF WARNINGS CAUTION SEE BELOW FOR LIST OF CAUTIONS

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

Instruction Manual & Safety Warnings

installation and operating instructions for the following xtreme Battery chargers:

user s manual Model number

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

INSTANT JUMPSTARTING POWER USER MANUAL. Copyright PowerStation, LLC All rights reserved MODEL: PS1100

SP6. Automatic Battery Charger. Model

15Amp Intelligent Battery Charger Suitable for SLA, Gel, Maintenance Free, AGM, Deep Cycle batteries

SBC / 2140 / Stage Battery Charger User Manual

BusPro Series Instruction Manual

BoostPak2 Instruction Manual

QPET, QPETXU Battery Chargers

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Transcription:

OWNER S MANUAL BATTERY BACKUP SUMP Installation Operation Parts For further operating, installation or maintenance assistance, Call 98-8-05 PRINTED IN U.S.A. M-8 (/9)

RULES FOR SAFE INSTALLATION AND OPERATION Carefully read and follow all safety instructions in this manual or on system. This is the safety alert symbol. When you see this symbol on your or in this manual, look for one of the following signal words and be alert to the potential for personal injury! DANGER warns about hazards that WILL cause serious personal injury, death or major property damage if ignored. WARNING warns about hazards that CAN cause serious personal injury, death or major property damage if ignored. CAUTION warns about hazards that WILL or CAN cause minor personal injury or property damage if ignored. The word NOTICE indicates special instructions which are important but not related to hazards.. To avoid risk of serious bodily injury and property damage, read safety instruction carefully before installing.. Follow local and/or national plumbing and electrical codes when installing. A ground fault circuit interrupter (GFCI) is recommended for use on any electrical appliance submerged in water.. Use this only for backup sump duty in a residential application. It is not designed as a primary sump.. Hazardous Voltage. Can cause severe or fatal electrical shock. Do not plug in or unplug battery charger while standing on a wet floor or in water. Be sure one hand is free when plugging in or unplugging charger. If basement floor is wet, disconnect power to basement before walking on floor. 5. Do not lift by electrical cord. 6. Pump water only with this.. Pump is permanently lubricated at the factory. Do not try to lubricate it! 8. Keep battery charger and battery box in a dry, cool, well ventilated area. 9. To avoid danger of fire or explosion, keep sparks and flame away from battery. 0. Battery acid is corrosive. Do not spill on skin, clothing, or battery charger. Wear eye protection when working on battery.. Maximum vertical ing distance is 5 feet (.6M).. Make sure sump is clear of debris. BASIC TOOLS AND MATERIALS NEEDED Pipe Wrenches, Screwdriver, Hacksaw, Adjustable Wrench, Teflon Tape, Knife, -volt Battery, PVC Cement, Primary Pump Check Valve (If not installed) GENERAL INFORMATION The battery back-up sump system is not a substitute for your primary sump. It is designed as a backup to pinch-hit for your primary sump during a power outage or other problem which prevents normal operation. Do not use it to flammable liquids or chemicals. Keep battery charger dry and protected from damage, In an emergency (such as an extended power outage) which depletes the system battery, your automobile battery may be temporarily substituted. Be sure to replace the system battery as soon as possible. CHARGER OPERATION Backup will start automatically when sump water level rises far enough to trip float switch. After a delay of about seconds, alarm will sound. Silence alarm by pushing ALARM TEST/RESET button. In normal (switch actuated) operation, alarm is locked out until about seconds after float switch has dropped to OFF position, cycle can then begin again. Test alarm by pushing ALARM TEST/RESET button when alarm is not sounding. Alarm will then sound as long as button is held down. Pushing ALARM TEST/RESET button to test alarm overrides lockout, so alarm can be tested at any time. If alarm sounds, check operation of primary, which may need service. If battery backup operation is due to a power outage, alarm will sound, but no service is likely to be required to primary. Battery charger has capacity to run and charge battery at the same time as long as power to the charger is not interrupted. If power to charger circuit is interrupted, the length of time that the backup will run depends on the ampere-hour capacity of the battery used. Extended periods of operation (for example, during an extended power outage) may exhaust the battery. However, once the load is removed, usually it will self-regenerate far enough to allow the charger to start. The battery charger will begin charging the battery as long as the battery has a charge of at least / volt. After power is restored, charger will automatically recharge battery fully in about six hours. NOTICE: If battery has not reached a satisfactory voltage after hours of charging, alarm will sound. In this case alarm cannot be reset. Possible causes are: PROBLEM ACTION Back-up has run Push Reset. Check main Power out more than Disconnect charger from battery. hours Call power company. Continuous charging Disconnect charger from battery more than hours Check for defective battery. Loose connection or Disconnect charger from battery. no power to charger Check plug, receptacle, power at main breaker After restoring power or replacing battery, alarm can be reset. TABLE - CAPACITY RATINGS Gallons Per Hour Battery Life (05 Amp Hour Battery) Total Gallons Pumped VERTICAL ING DISTANCE 5 FEET 0 FEET FEET 00 900 500 9 9 0,00 600 800

BATTERY REQUIREMENTS Hazardous electrical current. Can cause severe burns and start a fire if battery terminals are short circuited. Install battery in box. To prevent accidental shorting across battery terminals, strap cover securely on battery box. Do not leave battery uncovered. Do not allow children to play around sump installation. Your backup sump depends on the battery used with it for power. The better the battery, the better the performance of the. We recommend the use of a 05 Amp Deep Cycle Marine Battery. This battery will perform well for many hours and stands up well to long periods of little or no use. Use of a standard automobile battery with this charger is not recommended. An automobile battery may require charging after only - hours of continuous use, and the repeated charging cycles may cause early plate failure in the battery. Use only a new, fully charged battery that will fit in the battery box (maximum size -5/8" long, " wide and 9-/8" high (0.mm x.8mm x 8mm) including terminals). INSTALLATION AND OPERATION NOTICE: We recommend a trial fitting of all components before gluing anything. This will allow you to check mounting height float switch clearance, etc., while adjustments can still be easily made. 5 ELBOW HOSE CLAMP BRACKET. Fill sump until primary turns on. Mark this level as Normal High Water.. When installing the, mount the centerline of the tee inlet at least inches above the normal high water level.. Check that the location of the tee is at least inches below the top of the sump.. Make sure the installation will not interfere with the primary sump operation as follows: (A) Back up must not interfere with primary float switch swing. (B) Normal high water level must not be high enough to start the back-up. (C) Install a check valve (Rule #M-8) in the main sump discharge pipe below the back-up tee. Flow in this pipe must be away from the primary. DO NOT INSTALL IT BACKWARDS! This valve will prevent flow from the back-up back to the sump during battery powered operation. 5. Cut rigid discharge pipe from primary sump to length, use PVC piping. Tee supplied is / inch slip fit; if necessary use /" bushings supplied. Do not glue the tee until all parts have been trial fitted and aligned. HOSE CLAMP ELBOW SWITCH " (000) MAX SW TOP OF SUMP " MIN " REDUCING BUSHINGS () If required 6. Thread check valve tightly into the elbow provided and plug the discharge into the other end of the elbow. Secure with hose clamp. Slip the plain end of the check valve into the side socket of the tee.. Install the float switch on the stainless steel bracket provided and attach the bracket as shown below:.6 REF. SUMP FLOAT SW PRIMARY MAX FIGURE Standard Installation " MIN ON POSITION (Primary Pump Normal High Water Level) Must be installed to prevent recirculation into sump. SWITCH BRACKET IF REQ D CLAMP Adjust bracket to support /switch assembly to approximately level position. (opening on other side) 5 IF REQ D

8. Check for clearance to all working parts of the primary and backup systems. 9. Remove assembly from tee. Remove tee from. 0. Using PVC Cement, permanently install the tee on the discharge pipe, according to the PVC Cement instructions. Hazardous Fumes. Follow cement manufacturer s instructions. Use PVC Cement only in a well ventilated area away from fire or flame.. Reinstall switch/bracket assembly.. Using PVC Cement, permanently install the assembly by cementing the check valve into the tee side socket, with the base approximately level.. Adjust the switch/bracket assembly to support the. Tighten the clamp.. Make sure battery is fully charged: then check operation by disconnecting power to the primary sump and filling sump until the battery operated starts. Run through one complete cycle. 5. Operation may be checked at any time by rotating the extended float switch () pivots to turn on the. PRIMARY DISCHARGE PIPE ELBOW The liquid sound you hear in the float portion of the switch is mercury, not water, and should be disposed of properly. If you cannot arrange for proper disposal, the product may be returned for disposal to: RULE INDUSTRIES, INC Cape Ann Industrial Park Gloucester, MA 090 FIGURE Assembly Details

BLACK BROWN 5 GRAY FUSE HOLDER 6 FUSE CONNECTORS NEGATIVE BATTERY 05 AMP MIN 8 BLUE + POSITIVE 8 GRAY BLACK/WHITE + + SWITCH BLACK SENSOR FIGURE Wiring Diagram CHARGER ELECTRICAL CONNECTIONS Hazardous voltage. Can cause serious or fatal electrical shock. Review safety instructions before operating charger. Do not modify cord or plug. CHARGER/BATTERY INSTALLATION NOTICE: Alarm will sound when charger is first connected to battery. Press ALARM TEST/RESET button on charger. If alarm continues to sound, disconnect one charger lead from the battery and reconnect it. Press ALARM TEST/RESET again; alarm will stop sounding.. Connect charger as shown in Figure. A. Connect Positive (+) lead from charger to positive battery terminal. B. Connect Negative ( ) lead from charger to negative battery terminal. C. Connect the third (Blue) lead from the charger to the Blue tap on the Brown wire just before the fuse holder. D. Put the 5 Amp fuse into / of the fuse holder and connect the second half of the fuse holder. E. Connect the Black wire to the Negative battery terminal. F. Connect the Gray switch wire marked + to the Positive battery terminal.. Plug in power cord to a 5-5 Volt AC outlet delivering at least amps. Do not use a switch controlled outlet. Mark circuit in main power panel Backup sump power supply; do not turn off.. With charger properly connected and plugged in, the panel on the front of the charger will appear as in one of the following: A. If battery is dead, charger will supply about 0 amps power (see Figure A). 5 B. If battery is near full charge, charger will deliver about 5 amps power (see Figure B). C. If battery is fully charged, charging current will be 0 amps and green LED lamp will be lighted (see Figure C).. The charger is equipped with a self-resetting circuit breaker which protects it from temporary overloads. In case of an overload, the circuit breaker will open. It automatically resets after a short cooldown period. In some conditions where the overload is extended the breaker will cycle, repeating the open/reset process indefinitely. When this happens, normally the charger will emit a clicking sound as the breaker opens and resets. NOTICE: If the clicking sound continues for more than 0 minutes or so, check for reversed charger connections to the battery and for shorted cells in the battery. A. B. C. DC AMPS CHARGED CHARGING 6 8 0 CHARGE COMPLETE DC AMPS CHARGED CHARGING 6 8 0 CHARGE COMPLETE DC AMPS CHARGED CHARGING 6 8 0 CHARGE COMPLETE FIGURE - Battery Backup Control Panel A. Battery depleted - charging current 0 amps. B. Battery nearly charged - current about 5 amps. C. Charge complete - current 0 amps, LED Lights up.

BATTERY MAINTENANCE NOTICE: To protect battery case from chipping and gouging, do not let battery sit on concrete floor. Install battery on a shelf or protective pad (plywood, xs, etc.). Always install battery in a dry location that is protected from flooding. Every three months, check battery as follows to maintain battery in best condition:. Unplug battery charger.. On batteries with removable top caps, measure specific gravity of the electrolyte. Use a hydrometer (available at auto parts stores). If the specific gravity of any cell is less than.5 or if there is more than.050 variation between cells, replace the battery.. Check electrolyte level and refill as needed.. Check battery terminals and clamps for tightness and corrosion. Clean and tighten as needed. 5. Plug in battery charger. TROUBLESHOOTING Pump won t run.. Check all connections.. Check for low or defective battery.. Check that automatic switch is free to swing up and down.. Blown fuse in switch circuit. Unplug and remove the strainer. Check to see if impeller is free to turn. If impeller is locked remove the obstruction. Replace strainer and fuse. Motor hums but won t run:. Check for low or defective battery. Pump runs but s very little or no water:. Make sure a check valve is installed and functioning between primary discharge and Backup Sump Pump tee.. Check for obstruction in discharge pipe.. Discharge pipe length and/or height exceeds capacity of. See Table, Page, for capacity.. Check for low or defective battery. 5. Drill a /6 to /8 inch diameter vent hole between discharge and check valve. Pump cycles too frequently:. Main check valve located between discharge of primary and the Backup Sump Pump tee or check valve not installed or working properly. Install or repair as required. REPAIR PARTS LIST KEY NO. QTY PART NO PART (See Figures) MODEL 0BB - M-60 Tee, / socket - M-6 Reducing bushing / x / - MODEL 0-6BB Pump, 000 GPH - MODEL 0-6BB Float Switch Assembly 5 - M-6 Fuse Holder 6 - M-6(5) Fuse, 5 Amp - Kit ()M65, ()M66, ()M6, ()M68 Wire Terminals 8 - M- Top post battery terminals 9 - M5 Battery Case, Strap & hold down 0 - M- Charger assembly - M-80 Check valve, " MPT - M-6 Elbow, " FPT - M-6 Hose clamp - M-59 Pump/switch bracket 5 - M- Hose clamp 6 - M-8 Owner s manual 6

LIMITED WARRANTY Rule Industries, Inc. warrants to the original retail purchaser that its Battery Backup Sump Pump System is free from defective materials and workmanship for a period of one year from the date of purchase. If any component of the system fails to operate due to a manufacturing defect within the one year period, Rule will repair or replace the item free of charge. Proof of date of sale must accompany all returns. Please contact Rule Customer Service for complete information about warranty service: telephone number 98/8-05. Rule Industries Cape Ann Industrial Park Gloucester, MA 090 Tel.: (98) 8-00